Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reliability testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Extended life testing evaluation of complementary MOS integrated circuits

The purpose of the extended life testing evaluation of complementary MOS integrated circuits was twofold: (1) To ascertain the long life capability of complementary MOS devices. (2) To assess the objectivity and reliability of various accelerated life test methods as an indication or prediction tool. In addition, the determination of a suitable life test sequence for these devices was of importance. Conclusions reached based on the parts tested and the test results obtained was that the devices were not acceptable.

Brosnan, T. E.↗

Plastic Encapsulated Microcircuits (PEMs) Reliability Guide

It is reported by some users and has been demonstrated by others via testing and qualification that the quality and reliability of plastic-encapsulated microcircuits (PEMs) manufactured today are excellent in commercial applications and closely equivalent, and in some cases superior to their hemetic counterparts.

plastic encapsulated microcircuits reliability gui↗

Performance tests on the Kohmyr ECC ozone sonde

The reliability and accuracy of the Kohmyr ECC ozone sonde are determined. Emphasis is placed on establishing and testing for leak-free connections and stable pump flow rates as well as properly adjusting the pumping pressure. Calibration of the Kohmyr ECC ozone sondes and Dasibi monitors is described. Raw ordinate data and ozone connection data are presented in tabular form. The results of a linear regression treatment of the sonde-indicated ozone concentration vs. Dasibi readings for each switch position are included along with averages of the regression parameters over the six sequencing switch positions. It is suggested that sondes and Dasibi monitors be individually calibrated before flight.

Bandy, A. R.↗

A portable battery for objective, non-obstrusive measures of human performances

The need for a standardized battery of human performance tests to measure the effects of various treatments is pointed out. Progress in such a program is reported. Three batteries are available which differ in length and the number of tests in the battery. All tests are implemented on a portable, lap held, briefcase size microprocessor. Performances measured include: information processing, memory, visual perception, reasoning, and motor skills, programs to determine norms, reliabilities, stabilities, factor structure of tests, comparisons with marker tests, apparatus suitability. Rationale for the battery is provided.

Kennedy, R. S.↗

Langley Ground Facilities and Testing in the 21st Century

A strategic approach for retaining and more efficiently operating the essential Langley Ground Testing Facilities in the 21st Century is presented. This effort takes advantage of the previously completed and ongoing studies at the Agency and National levels. This integrated approach takes into consideration the overall decline in test business base within the nation and reduced utilization in each of the Langley facilities with capabilities to test in the subsonic, transonic, supersonic, and hypersonic speed regimes. The strategy accounts for capability needs to meet the Agency programmatic requirements and strategic goals and to execute test activities in the most efficient and flexible facility operating structure. The structure currently being implemented at Langley offers agility to right-size our capability and capacity from a national perspective, to accommodate the dynamic nature of the testing needs, and will address the influence of existing and emerging analytical tools for design. The paradigm for testing in the retained facilities is to efficiently and reliably provide more accurate and high-quality test results at an affordable cost to support design information needs for flight regimes where the computational capability is not adequate and to verify and validate the existing and emerging computational tools. Each of the above goals are planned to be achieved, keeping in mind the increasing small industry customer base engaged in developing unpiloted aerial vehicles and commercial space transportation systems.

Ambur, Damodar R.↗

Test Driven Development of Scientific Models

Test-Driven Development (TDD), a software development process that promises many advantages for developer productivity and software reliability, has become widely accepted among professional software engineers. As the name suggests, TDD practitioners alternate between writing short automated tests and producing code that passes those tests. Although this overly simplified description will undoubtedly sound prohibitively burdensome to many uninitiated developers, the advent of powerful unit-testing frameworks greatly reduces the effort required to produce and routinely execute suites of tests. By testimony, many developers find TDD to be addicting after only a few days of exposure, and find it unthinkable to return to previous practices.After a brief overview of the TDD process and my experience in applying the methodology for development activities at Goddard, I will delve more deeply into some of the challenges that are posed by numerical and scientific software as well as tools and implementation approaches that should address those challenges.

Overview of TDD Process↗

Particle Filter Based Inference Testing

The primary intent of PAR-FIT (Particle Filter based Inference Testing) is to provide hard inductive evidence that a machine learning model is capable and proven for an individual test input. By examining training data used to form the underlying model functional correlation, an estimate of the reliability that a model will make the correct prediction can be made. The Sequential Probability Ratio Test is used to derive a qualitative evaluation for reliability based on hypothesis testing. The PAR-FIT framework achieves this by implementing a particle filter and the sequential probability ratio test algorithms on the machine learning model training data to determine relevancy of new individual test samples to the training dataset. The kernel function evaluates the local proximity and density of training data used to derive a prediction outcome. Particles are used to probabilistically determine which training data to evaluate for proximity. For test samples that are within a close proximity to and surrounded by multiple training data points, the evaluated reliability of the prediction is high. For test samples that are anomalies not represented by the training dataset, in low density data clusters, or are far from existing data points, the evaluated reliability is low as insufficient training evidence exists to suggest the model is capable of making the correct prediction. Sequential Probability Ratio Test is further used to determine when a hypothesis on whether a signal can be rejected or accepted for use. The ratio test collects sequence information from the particle filter to test whether the signal is anomalous or normal via hypothesis testing of the underlying distributions.

Chen, Edward [Idaho National Laboratory (INL), Ida↗

Advanced Failure Determination Measurement Techniques Used in Thermal Fatigue Life Testing of Electronic Packaging

Thermal fatigue life testing of various electronic packaging technologies is being performed by the Reliability Technology Group at the Jet Propulsion Laboratory. These testing efforts are in progress to improve uderstanding of the reliability issues associated with low volume packaging technologies for space applications and to develop qualification and acceptance approaches for these technologies. The work described here outlines the electrical failure detection techniques used during testing by documenting the circuits and components used to make these measurements, the sensitivity of the measurements, and the applicability of each specific measurement.

fatigue surface mount measurement testing thermal ↗

Determining Functional Reliability of Pyrotechnic Mechanical Devices

This paper describes a new approach for evaluating mechanical performance and predicting the mechanical functional reliability of pyrotechnic devices. Not included are other possible failure modes, such as the initiation of the pyrotechnic energy source. The requirement of hundreds or thousands of consecutive, successful tests on identical components for reliability predictions, using the generally accepted go/no-go statistical approach routinely ignores physics of failure. The approach described in this paper begins with measuring, understanding and controlling mechanical performance variables. Then, the energy required to accomplish the function is compared to that delivered by the pyrotechnic energy source to determine mechanical functional margin. Finally, the data collected in establishing functional margin is analyzed to predict mechanical functional reliability, using small-sample statistics. A careful application of this approach can provide considerable cost improvements and understanding over that of go/no-go statistics. Performance and the effects of variables can be defined, and reliability predictions can be made by evaluating 20 or fewer units. The application of this approach to a pin puller used on a successful NASA mission is provided as an example.

Bement, Laurence J.↗

Evaluation plan for space station network interface units

Outlined here is a procedure for evaluating network interface units (NIUs) produced for the Space Station program. The procedures should be equally applicable to the data management system (DMS) testbed NIUs produced by Honeywell and IBM. The evaluation procedures are divided into four areas. Performance measurement tools are hardware and software that must be developed in order to evaluate NIU performance. Performance tests are a series of tests, each of which documents some specific characteristic of NIU and/or network performance. In general, these performance tests quantify the speed, capacity, latency, and reliability of message transmission under a wide variety of conditions. Functionality tests are a series of tests and code inspections that demonstrate the functionality of the particular subset of ISO protocols which have been implemented in a given NIU. Conformance tests are a series of tests which would expose whether or not selected features within the ISO protocols are present and interoperable.

Weaver, Alfred C.↗

Robotic Assembly of Truss Structures for Space Systems and Future Research Plans

Many initiatives under study by both the space science and earth science communities require large space systems, i.e. with apertures greater than 15 m or dimensions greater than 20 m. This paper reviews the effort in NASA Langley Research Center's Automated Structural Assembly Laboratory which laid the foundations for robotic construction of these systems. In the Automated Structural Assembly Laboratory reliable autonomous assembly and disassembly of an 8 meter planar structure composed of 102 truss elements covered by 12 panels was demonstrated. The paper reviews the hardware and software design philosophy which led to reliable operation during weeks of near continuous testing. Special attention is given to highlight the features enhancing assembly reliability.

Doggett, William↗

ON THE EFFECTIVENESS OF LLMS IN UNIT TEST GENERATION FOR STRUCTURED TEXT PROGRAMS

The reliability of industrial automation systems heavily depends on the correctness of Programmable Logic Controller (PLC) programs, which are often written in Structured Text (ST). While Large Language Models (LLMs) have shown promise in automating test generation for mainstream programming languages, their effectiveness for the syntactically strict ST language remains underexplored. This thesis presents a systematic empirical evaluation of three state-of-the-art LLMs—GPT-4o, Gemini 2.5 Pro, and Claude Sonnet 4.5—for generating ST unit tests. We examine three prompting strategies: Natural Language (NL), Code Language (CL), and Chain-of-Thought (CoT), across a curated set of 11 ST function blocks. The quality of the generated tests is assessed using Compilation Success Rate (CSR), Statement Coverage (SC), and Branch Coverage (BC). In the zero-shot setting, Claude Sonnet 4.5 achieves the highest CSR, while Gemini 2.5 Pro consistently delivers the best statement and branch coverage, particularly under CL prompts. By incorporating a one-shot CL prompt, all models exhibit substantial improvements—most notably GPT-4o, whose CSR increases from 45.45% to 90.91%, with substantial gains in both SC and BC. To further contextualize these findings, we compare GPT-4o’s one-shot results with PLCAutoTester, a state-ofthe- art ST unit test generation tool, on an additional benchmark dataset. While LLMgenerated tests approach competitive coverage levels, PLCAutoTester maintains significantly higher and more stable coverage across programs. This study provides the first comprehensive benchmark of modern LLMs for ST unit testing, highlighting their strengths, limitations, and improvements through one-shot prompting, and positioning their performance relative to specialized automated testing tools in industrial automation.

42 ENGINEERING↗

Design and test of the 172K fluidic rudder

Progress in the development of concepts for control of aircraft without moving parts or a separate source of power is described. The design and wind tunnel tests of a full scale fluidic rudder for a Cessna 172K aircraft, intended for subsequent flight tests were documented. The 172K fluidic rudder was designed to provide a control force equivalent to 3.3 degrees of deflection of the conventional rudder. In spite of an extremely thin airfoil, cascaded fluidic amplifiers were built to fit, with the capacity for generating the required level of control force. Wind tunnel tests demonstrated that the principles of lift control using ram air power are sound and reliable under all flight conditions. The tests also demonstrated that the performance of the 172K fluidic rudder is not acceptable for flight tests until the design of the scoop is modified to prevent interference with the lift control phenomenon.

Belsterling, C. A.↗

Motor and cognitive testing of bone marrow transplant patients after chemoradiotherapy

Assessment of cognitive and motor performance of bone marrow transplant patients prior to, during, and following intensive toxic chemoradiotherapy may provide an important adjunct to measures of physiological and medical status. The present study is an attempt to assess whether, as side-effects, these aggressive treatments result in cognitive performance deficits, and if so, whether such changes recover posttreatment. Measurement of cognitive ability in this situation presents special problems not encountered with one-time tests intended for healthy adults. Such tests must be sensitive to changes within a single individual, which emphasizes the crucial importance of high reliability, stability across repeated-measures, and resistance to confounding factors such as motivation and fatigue. The present research makes use of a microbased portable test battery developed to have reliable and sensitive tests which were adapted to study the special requirements of transplant patients who may suffer cognitive deficits as a result of treatment. The results showed slight but significant changes in neuropsychological capacity when compared to baseline levels and controls, particularly near the beginning of treatment. The sensitivity of the battery in detecting such subtle temporary changes is discussed in terms of past research showing effects of other stressors, such as stimulated high altitude and ingestion of alcohol, on these measures.

Non-NASA Center↗