From Bessel beam to complex-source-point cylindrical wave-function

This investigation shows that a scalar Bessel beam can be transformed into the non-paraxial complex-source-point cylindrical wave (CSPCW). High-order CSPCW solutions, termed here high-order quasi-Gaussian cylindrical beams, which exactly satisfy the Helmholtz equation, are derived analytically. Moreover, partial-derivatives of the high-order CSPCW solutions satisfy the Helmholtz equation. In addition, the CSPCW solutions satisfy the nonrelativistic Schrödinger equation within standard quantum mechanics, thus, the results can be used in the description of elementary particle/matter motion and related applications in quantum scattering theory. Furthermore, the analysis is extended to the case of vector beams in which the components of the electromagnetic (EM) field are obtained based on different polarizations of the magnetic and electric vector potentials, which exactly satisfy Maxwell’s vectorial equations and Lorenz’ gauge condition. An attractive feature of the high-order solutions is the rigorous description of strongly focused (or strongly divergent) cylindrical wave-fields without any approximations, nor the need for numerical methods. Possible applications are in beam-forming design using high-aperture or collimated cylindrical laser/electron quasi-Gaussian beams in imaging microscopy, particle manipulation, optical tweezers, and the study of the scattering, and radiation forces on objects. - Highlights: • Bessel beam is transformed into the non-paraxial cylindrical complex-source-point. • Exact high-order tightly focused solutions are derived without any approximations. • The exact solutions also satisfy the nonrelativistic Schrödinger equation. • Electromagnetic beams are obtained as solutions of Maxwell’s vectorial equations. • Applications are in laser/electron beam imaging, tweezers, and radiation force.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development and operation of a high-throughput accurate-wavelength lens-based spectrometer

A high-throughput spectrometer for the 400–820 nm wavelength range has been developed for charge exchange recombination spectroscopy or general spectroscopy. A large 2160 mm{sup −1} grating is matched with fast f/1.8 200 mm lenses, which provide stigmatic imaging. A precision optical encoder measures the grating angle with an accuracy ≤0.075 arc sec. A high quantum efficiency low-etaloning CCD detector allows operation at longer wavelengths. A patch panel allows input fibers to interface with interchangeable fiber holders that attach to a kinematic mount at the entrance slit. Computer-controlled hardware allows automated control of wavelength, timing, f-number, automated data collection, and wavelength calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum Loop Topography for Machine Learning

Despite rapidly growing interest in harnessing machine learning in the study of quantum many-body systems, training neural networks to identify quantum phases is a nontrivial challenge. The key challenge is in efficiently extracting essential information from the many-body Hamiltonian or wave function and turning the information into an image that can be fed into a neural network. When targeting topological phases, this task becomes particularly challenging as topological phases are defined in terms of nonlocal properties. Here, we introduce quantum loop topography (QLT): a procedure of constructing a multidimensional image from the “sample” Hamiltonian or wave function by evaluating two-point operators that form loops at independent Monte Carlo steps. The loop configuration is guided by the characteristic response for defining the phase, which is Hall conductivity for the cases at hand. Feeding QLT to a fully connected neural network with a single hidden layer, we demonstrate that the architecture can be effectively trained to distinguish the Chern insulator and the fractional Chern insulator from trivial insulators with high fidelity. In addition to establishing the first case of obtaining a phase diagram with a topological quantum phase transition with machine learning, the perspective of bridging traditional condensed matter theory with machine learning will be broadly valuable.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On contrast of biological X-ray nanomicroscopy

We analyse the absorption contrast of histological and cytological preparations, which can be achieved in nanomicroscopic studies using monochromatic radiation in the spectral range of 90 – 600 eV (14 – 2 nm). Two types of unstained biological objects are considered: untreated and fixed in paraffin, and optimum wavelengths are determined for the study of samples with a thickness of 0.5 – 10 μm with a spatial resolution of 100 – 20 nm. Taking into account the efficiency of X-ray optics, the number of source photons required to produce a single image is estimated. It is shown that the greatest interest for the study of fixed objects represents the spectral region of 7 – 14 nm, for which, on the basis of rapidly developing compact sources of incoherent and coherent radiation and effective optics, microscopes for scientific and clinical research can be designed. (paper)

60 APPLIED LIFE SCIENCES↗

An efficient reconstruction algorithm for differential phase-contrast tomographic images from a limited number of views

The main focus of this paper is reconstruction of tomographic phase-contrast image from a set of projections. We propose an efficient reconstruction algorithm for differential phase-contrast computed tomography that can considerably reduce the number of projections required for reconstruction. The key result underlying this research is a projection theorem that states that the second derivative of the projection set is linearly related to the Laplacian of the tomographic image. The proposed algorithm first reconstructs the Laplacian image of the phase-shift distribution from the second-derivative of the projections using total variation regularization. The second step is to obtain the phase-shift distribution by solving a Poisson equation whose source is the Laplacian image previously reconstructed under the Dirichlet condition. We demonstrate the efficacy of this algorithm using both synthetically generated simulation data and projection data acquired experimentally at a synchrotron. The experimental phase data were acquired from a human coronary artery specimen using dark-field-imaging optics pioneered by our group. Our results demonstrate that the proposed algorithm can reduce the number of projections to approximately 33% as compared with the conventional filtered backprojection method, without any detrimental effect on the image quality.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dimensionality and noise in energy selective x-ray imaging

Purpose: To develop and test a method to quantify the effect of dimensionality on the noise in energy selective x-ray imaging.Methods: The Cramèr-Rao lower bound (CRLB), a universal lower limit of the covariance of any unbiased estimator, is used to quantify the noise. It is shown that increasing dimensionality always increases, or at best leaves the same, the variance. An analytic formula for the increase in variance in an energy selective x-ray system is derived. The formula is used to gain insight into the dependence of the increase in variance on the properties of the additional basis functions, the measurement noise covariance, and the source spectrum. The formula is also used with computer simulations to quantify the dependence of the additional variance on these factors. Simulated images of an object with three materials are used to demonstrate the trade-off of increased information with dimensionality and noise. The images are computed from energy selective data with a maximum likelihood estimator.Results: The increase in variance depends most importantly on the dimension and on the properties of the additional basis functions. With the attenuation coefficients of cortical bone, soft tissue, and adipose tissue as the basis functions, the increase in variance of the bone component from two to three dimensions is 1.4 × 10{sup 3}. With the soft tissue component, it is 2.7 × 10{sup 4}. If the attenuation coefficient of a high atomic number contrast agent is used as the third basis function, there is only a slight increase in the variance from two to three basis functions, 1.03 and 7.4 for the bone and soft tissue components, respectively. The changes in spectrum shape with beam hardening also have a substantial effect. They increase the variance by a factor of approximately 200 for the bone component and 220 for the soft tissue component as the soft tissue object thickness increases from 1 to 30 cm. Decreasing the energy resolution of the detectors increases the variance of the bone component markedly with three dimension processing, approximately a factor of 25 as the resolution decreases from 100 to 3 bins. The increase with two dimension processing for adipose tissue is a factor of two and with the contrast agent as the third material for two or three dimensions is also a factor of two for both components. The simulated images show that a maximum likelihood estimator can be used to process energy selective x-ray data to produce images with noise close to the CRLB.Conclusions: The method presented can be used to compute the effects of the object attenuation coefficients and the x-ray system properties on the relationship of dimensionality and noise in energy selective x-ray imaging systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

AUTOMATED DEFECT CLASSIFICATION USING AN ARTIFICIAL NEURAL NETWORK

The automated defect classification algorithm based on artificial neural network with multilayer backpropagation structure was utilized. The selected features of flaws were used as input data. In order to train the neural network it is necessary to prepare learning data which is representative database of defects. Database preparation requires the following steps: image acquisition and pre-processing, image enhancement, defect detection and feature extraction. The real digital radiographs of welded parts of a ship were used for this purpose.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A simple approach to neutral atom microscopy

Scanning surfaces using a beam of noncharged atoms or molecules allows for especially nondestructive and low-energy surface imaging, with the potential to obtain new information about surfaces that cannot be easily obtained otherwise. We have developed a new approach, operating with the sample at a close working distance from an aperture, the need for optics to focus the beam is obviated. Compared to more complex approaches, the theoretical performance has no other disadvantage than the short working distance. Resolution of 1.5 {mu}m has been achieved, and submicron resolution appears to be practical. Construction of the microscope and results are presented, including first images done in reflection mode, theory for optimization of the design and avenues for future improvement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Long-range 3D imaging of highly dynamic objects using the intensity ratios of partial beams of reflected laser light

The procedural aspects of obtaining long-range three-dimensional images of highly dynamic objects using the ratios of partial beam intensities of the reflected laser light are considered. Alongside with the object images, the proposed method simultaneously provides the data on the object relief with high resolution on a set of surface points during a single-pulse location cycle. The high resolving power and speed of the method ensure the efficiency of its application to detecting and recognition of remote highly dynamic objects, including low-dimensional ones, by their 3D characteristics. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Resolution enhancement in nonlinear photoacoustic imaging

Nonlinear processes can be exploited to gain access to more information than is possible in the linear regime. Nonlinearity modifies the spectra of the excitation signals through harmonic generation, frequency mixing, and spectral shifting, so that features originally outside the detector range can be detected. Here, we present an experimental study of resolution enhancement for photoacoustic imaging of thin metal layers immersed in water. In this case, there is a threshold in the excitation below which no acoustic signal is detected. Above threshold, the nonlinearity reduces the width of the active area of the excitation beam, resulting in a narrower absorption region and thus improved spatial resolution. This gain is limited only by noise, as the active area of the excitation can be arbitrarily reduced when the fluence becomes closer to the threshold. Here, we demonstrate a two-fold improvement in resolution and quantify the image quality as the excitation fluence goes through threshold.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sn-based Ge/Ge{sub 0.975}Sn{sub 0.025}/Ge p-i-n photodetector operated with back-side illumination

We report an investigation of a GeSn-based p-i-n photodetector grown on a Ge wafer that collects light signal from the back of the wafer. Temperature dependent absorption measurements performed over a wide temperature range (300 K down to 25 K) show that (a) absorption starts at the indirect bandgap of the active GeSn layer and continues up to the direct bandgap of the Ge wafer, and (b) the peak responsivity increases rapidly at first with decreasing temperature, then increases more slowly, followed by a decrease at the lower temperatures. The maximum responsivity happens at 125 K, which can easily be achieved with the use of liquid nitrogen. The temperature dependence of the photocurrent is analyzed by taking into consideration of the temperature dependence of the electron and hole mobility in the active layer, and the analysis result is in reasonable agreement with the data in the temperature regime where the rapid increase occurs. This investigation demonstrates the feasibility of a GeSn-based photodiode that can be operated with back-side illumination for applications in image sensing systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The use of optical coherence tomography for morphological study of scaffolds

Aimed at possible widening of the optical coherence tomography (OCT) field of application, an attempt is made to use OCT in tissue engineering and cell transplantology as a tool for morphological studies of substrate materials by the example of scaffolds. By means of the traditional fibreoptical OCT scheme the images of inner structure of scaffolds are obtained, and simultaneously the spatial distribution of the intralipid flow velocity is reconstructed using the Doppler OCT. It is shown that combined use of traditional OCT and Doppler OCT schemes allows revealing the regions of the scaffold demonstrating optimal effect of shear stress, which is a key factor of cell growth.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analyzer-based phase contrast imaging and phase retrieval using a rotating anode x-ray source

We have performed an analyzer crystal based phase contrast imaging (ABI) experiment using a rotating anode x-ray source. The use of such an incoherent source demonstrates the potential of ABI as a quantitative characterization tool for the laboratory environment. A phase contrast image of a plastic phantom was recorded on high resolution x-ray film and the projected thickness was retrieved from a single image. The projected thickness recovered from the phase contrast image was shown to quantitatively agree with a reference optical microscope measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

GPU-based relative fuzzy connectedness image segmentation

Purpose:Recently, clinical radiological research and practice are becoming increasingly quantitative. Further, images continue to increase in size and volume. For quantitative radiology to become practical, it is crucial that image segmentation algorithms and their implementations are rapid and yield practical run time on very large data sets. The purpose of this paper is to present a parallel version of an algorithm that belongs to the family of fuzzy connectedness (FC) algorithms, to achieve an interactive speed for segmenting large medical image data sets. Methods: The most common FC segmentations, optimizing an Script-Small-L {sub {infinity}}-based energy, are known as relative fuzzy connectedness (RFC) and iterative relative fuzzy connectedness (IRFC). Both RFC and IRFC objects (of which IRFC contains RFC) can be found via linear time algorithms, linear with respect to the image size. The new algorithm, P-ORFC (for parallel optimal RFC), which is implemented by using NVIDIA's Compute Unified Device Architecture (CUDA) platform, considerably improves the computational speed of the above mentioned CPU based IRFC algorithm. Results: Experiments based on four data sets of small, medium, large, and super data size, achieved speedup factors of 32.8 Multiplication-Sign , 22.9 Multiplication-Sign , 20.9 Multiplication-Sign , and 17.5 Multiplication-Sign , correspondingly, on the NVIDIA Tesla C1060 platform. Although the output of P-ORFC need not precisely match that of IRFC output, it is very close to it and, as the authors prove, always lies between the RFC and IRFC objects. Conclusions: A parallel version of a top-of-the-line algorithm in the family of FC has been developed on the NVIDIA GPUs. An interactive speed of segmentation has been achieved, even for the largest medical image data set. Such GPU implementations may play a crucial role in automatic anatomy recognition in clinical radiology.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scanning magnetic imaging of Sr2RuO4

We magnetically imaged the ab-plane surface of single crystals of the unconventional superconductor Sr{sub 2}RuO{sub 4}, including one sample with an array of microholes, using scanning superconducting quantum interference device and Hall probe microscopy in a dilution refrigerator at low applied magnetic fields. The images show dilute trapped vortices, as would be expected in conventional type-II superconductors, and no other magnetic features. We found no direct signs of the spontaneous magnetization that would be expected in a time-reversal symmetry-breaking (TRSB) superconductor. These measurements set upper limits on the presence of TRSB signatures in this material.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Detection method and observed data of high-energy gamma rays under the influence of quantum gravity

The interaction of high-energy particles affected by quantum gravity is argued from the experimental viewpoint of raising a question, 'our detection method for high-energy γ-rays supplies trustworthy observation data and we are now seeing the true image of the universe through high-energy γ-rays?' The modified dispersion relation (MDR) for particles' energy and momentum is applied to the equation of energy-momentum conservation in particle reactions, to study the restriction imposed on the kinematic state of high-energy particles by the Lorentz invariance violation (LIV) due to quantum gravity, as a function of the incident particle energy of the reaction. The result suggests that the interaction utilized for γ-ray detection is not free from the effect of quantum gravity when γ-ray energy is higher than 10{sup 13} ∼ 10{sup 17} eV depending on models of MDR. Discussion is presented on the prospect of finding clear evidence of the LIV effect from γ-ray observations, as well as on the radiation and propagation mechanism of γ-rays under the influence of the LIV effect.

79 ASTRONOMY AND ASTROPHYSICS↗

A method to acquire CT organ dose map using OSL dosimeters and ATOM anthropomorphic phantoms

Purpose: To present the design and procedure of an experimental method for acquiring densely sampled organ dose map for CT applications, based on optically stimulated luminescence (OSL) dosimeters “nanoDots” and standard ATOM anthropomorphic phantoms; and to provide the results of applying the method—a dose data set with good statistics for the comparison with Monte Carlo simulation result in the future.Methods: A standard ATOM phantom has densely located holes (in 3 × 3 cm or 1.5 × 1.5 cm grids), which are too small (5 mm in diameter) to host many types of dosimeters, including the nanoDots. The authors modified the conventional way in which nanoDots are used, by removing the OSL disks from the holders before inserting them inside a standard ATOM phantom for dose measurements. The authors solved three technical difficulties introduced by this modification: (1) energy dependent dose calibration for raw OSL readings; (2) influence of the brief background exposure of OSL disks to dimmed room light; (3) correct pairing between the dose readings and measurement locations. The authors acquired 100 dose measurements at various positions in the phantom, which was scanned using a clinical chest protocol with both angular and z-axis tube current modulations.Results: Dose calibration was performed according to the beam qualities inside the phantom as determined from an established Monte Carlo model of the scanner. The influence of the brief exposure to dimmed room light was evaluated and deemed negligible. Pairing between the OSL readings and measurement locations was ensured by the experimental design. The organ doses measured for a routine adult chest scan protocol ranged from 9.4 to 18.8 mGy, depending on the composition, location, and surrounding anatomy of the organs. The dose distribution across different slices of the phantom strongly depended on the z-axis mA modulation. In the same slice, doses to the soft tissues other than the spinal cord demonstrated relatively small variations, with the maximum COV around 11.4%. This might be attributed to the angular mA modulation, the placement of the dosimeters, the chest cavity of the scanned region, and the size of the phantom. Doses to the spinal cord were consistently lower than those to other soft tissues.Conclusions: The method is suited for acquiring densely sampled organ dose maps, and can be used for studying dose distributions relevant to subject size, organ location, and clinical CT protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗