Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pulse shaping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

TPSAS-NF1676L-34013-DND

Currently, many experiments pursuing comprehensive characterization of the atmosphere include coordinated observations by both lidar and polarimeters in order to obtain important complimentary information about aerosol properties. The most advanced passive observations by space-based multi-angle polarimeters are sensitive to the properties of aerosol in total atmospheric column, but have very limited sensitivity to vertical structure of the atmosphere. Polarimeter observations can be used not only for retrieval of aerosol optical thickness, but also for deriving microphysical information about aerosol particle shape, size distribution, complex refractive index, and the properties of underlying surface (Dubovik et al., 2019). In a contrast, the lidar observations of atmospheric responses from different altitudes to laser pulses are designed to provide vertical profiles of atmospheric characteristics. Here we present the recent advancement in GRASP algorithm (Generalized Aerosol Retrieval of Atmospheric and Surface Properties) (Dubovik et al., 2011, 2014) that allows simultaneous inversion of co-incident lidar and polarimeter spaceborne observations and derives a united set of vertically resolved aerosol and surface parameters. Such synergetic retrieval is an extension to satellite data of the approach for synergetic processing of active and passive measurements developed earlier by (Lopatin et al., 2013) for ground-based observations. Another addition to these developments is the inclusion of Raman-shifted and volume depolarization backscattering observations that improve sensitivity to the vertical properties of aerosol, while polarimetric observations provide sufficient constraints on aerosol type and loading that generally are missing in lidar signals. The potential and limitations of such synergetic processing is illustrated by application to co-incident PARASOL and CALIPSO data.

Anton Lopatin↗

Synchrotron radiography of Richtmyer–Meshkov instability driven by exploding wire arrays

We present a new technique for the investigation of shock-driven hydrodynamic phenomena in gases, liquids, and solids in arbitrary geometries. The technique consists of a pulsed power-driven resistive wire array explosion in combination with multi-MHz synchrotron radiography. Compared to commonly used techniques, it offers multiple advantages: (1) the shockwave geometry can be shaped to the requirements of the experiment, (2) the pressure (P > 300 MPa) generated by the exploding wires enables the use of liquid and solid hydrodynamic targets with well-characterized initial conditions (ICs), (3) the multi-MHz radiography enables data acquisition to occur within a single experiment, eliminating uncertainties regarding repeatability of the ICs and subsequent dynamics, and (4) the radiographic measurements enable estimation of compression ratios from the x-ray attenuation. In addition, the use of a synchrotron x-ray source allows the hydrodynamic samples to be volumetrically characterized at a high spatial resolution with synchrotron-based microtomography. This experimental technique is demonstrated by performing a planar Richtmyer–Meshkov instability (RMI) experiment on an aerogel–water interface characterized by Atwood number A0∼−0.8 and Mach number M∼1.5. The qualitative and quantitative features of the experiment are discussed, including the energy deposition into the exploding wires, shockwave generation, compression of the interface, startup phase of the instability, and asymptotic growth consistent with Richtmyer's impulsive theory. Additional effects unique to liquids and solids—such as cavitation bubbles caused by rarefaction flows or initial jetting due to small perturbations—are observed. It is also demonstrated that the technique is not shape dependent by driving a cylindrically convergent RMI experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A study of resistive peeling–ballooning modes across spherical tokamaks

We investigate how non-ideal-magnetohydrodynamics (MHD) effects, in particular plasma resistivity, impact the peeling–ballooning stability thresholds in spherical tokamaks. This analysis follows the discovery of resistive kink-peeling modes in ELMing National Spherical Torus Experiment (NSTX) discharges. In the present study we extend this modeling to ELMing pulses in the Mega Ampere Spherical Tokamak (MAST) and MAST—Upgrade (MAST-U), where we find a clear resistive scaling for peeling–ballooning modes. While in NSTX ideal-MHD predicts stability for ELMing discharges, in MAST-U we find that the plasma is slightly unstable to peeling–ballooning modes, but is fully stabilized once diamagnetic effects are considered in terms of a growth rate normalization. A resistive power law scaling is calculated for these modes on MAST-U, which lies in between that of tearing modes and resistive interchange modes. A comparison between M3D-C1 and NIMROD shows reasonable agreement for this scaling. Resistivity destabilizes the modes and the peeling–ballooning unstable domain is considerably expanded in both, MAST and MAST-U. In addition to the MAST/-U pulses we also analyze resistive PB stability in a NSTX-similarity discharge on DIII-D. While having a different aspect ratio from NSTX, this discharge uses NSTX-like shaping parameters, toroidal field and plasma current. By considering these discharges alongside NSTX cases, we identify conditions influencing the onset of resistive peeling–ballooning modes. Furthermore, our findings indicate that magnetic shear in the pedestal region is closely linked to the emergence of resistive edge modes.

MAST-U↗

Analysis of requirements for GEOS-C laser cube-corner reflector panels

A mathematical analysis of the tradeoffs and requirements was performed to develop an improved array design which will give stronger returns at lower elevation angles and reduce pulse spread in the return. It was determined that a zenith angle of 75deg can be obtained with an array with an area of 0.28 sq m, if the array is shaped on the surface of a 45 deg cone whose axis is coincident to the satellite axis. The total weight of the truncated pyramid array with 270 cube corners is calculated to be not more than 50% greater than the GEOS 2 array, while the efficiency is increased 275%.

Minott, P. O.↗

Measurements in liquid fuel sprays

Techniques for studying the events directly preceding combustion in the liquid fuel sprays are being used to provide information as a function of space and time on droplet size, shape, number density, position, angle of flight and velocity. Spray chambers were designed and constructed for: (1) air-assist liquid fuel research sprays; (2) high pressure and temperature chamber for pulsed diesel fuel sprays; and (3) coal-water slurry sprays. Recent results utilizing photography, cinematography, and calibration of the Malvern particle sizer are reported. Systems for simultaneous measurement of velocity and particle size distributions using laser Doppler anemometry interferometry and the application of holography in liquid fuel sprays are being calibrated.

Chigier, N.↗

Charge per Micro-Pulse Calculation for Ideal Lujan and WNR beams

A complete redesign of the LANSCE front-end is currently under development for the Los Alamos Modernization Project (LAMP). This includes the replacement of the traditional Cockroft-Walton injection system to the newer radiofrequency quadrupole (RFQ) standard. LANSCE accelerates both H- and H+ beams and therefore requires an unconventional application for RFQ systems. A new facility could consider using an independent RFQ for each beam species. However, with the tight space of the LANSCE injector facility, it would prove difficult to instrument. Our initial studies have shown that a single RFQ could be used. The negatively- and positively-charged direct current (DC) beams are shaped, bunched, and accelerated out of phase to each other, with very little interaction. This would work for all possible H+ beam gates and most H- Beam gates. However, a challenge arises with the Weapons Neutron Research (WNR) beam structure that requires the acceleration of bunched beams at higher charge density per pulse. The Long Bunch Enable Gate (LBEG) used for the Lujan center is the best example of a standard injector beam gate. The beam gate, or Macro-Pulse (MP), is 625-us long, separated by at least 8.3 ms. A chopper is used to dice the MP into 1750 mini-Pulses (mP), which are 290-ns wide. After chopping, the MP contains 100,000 micro-Pulses (uP), which are generated by the linac acceleration structure modulated at 201.25 MHz; that is, the micro-Pulses are separated 5 ns apart from each other. The H+ beam structure will be very similar once a chopper is added to its transport. However, the Multi-Pulse Enable Gate (MPEG) used for WNR is significantly different in structure. In this case, the mP is chopped to be only 35-ns wide. This width is then rotated into a single 201.25 MHz RF bucket using the Low Frequency Buncher (LFB). This is proving difficult for the RFQ design in the LAMP upgrade. We began investigating the amount of current sent to WNR for two reasons. Firstly, we wanted to find a solution to avoid using the Low Frequency Buncher to simplify the LAMP RFQ design. It is simple to inject and accelerate a 35 mA DC beam in the LAMP RFQ (this is done in numerous accelerator facilities). However, injecting a short bunch with a larger current (once compressed to 5 ns to meet the RFQ frequency) may be difficult. Second, we have a technique called PSR2WNR in which we do not employ the Low Frequency Buncher, but rather accumulate 5 LBEG uP (5 ns) in the PSR and deliver the accumulated beam to WNR every 1.8 us. As a result, we could provide to WNR with five accumulated LBEG uPs every shot. The goal here is to create a rapid kicker with a frequency response of 555 kHz. DARHT-II and other accelerator facilities have constructed kickers of this type for other uses, and our engineers consider this technology as feasible.

43 PARTICLE ACCELERATORS↗

Spectroscopic performance of Low-Gain Avalanche Diodes for different types of radiation

LGADs (Low-Gain Avalanche Diodes or Detectors) are a type of silicon Avalanche Photo-Diodes originally developed for the fast detection of minimum ionizing particles in high-energy physics experiments. Thanks to their fast timing performance, the LGAD paradigm enables detectors to accurately measure minimum ionizing particles with a timing resolution of a few tens of picoseconds. Such a performance is due to a thin substrate and the presence of a moderate signal gain. This internal gain of a few tens is enough to compensate for the reduced charge deposition in the thinner substrate and the noise of fast read-out systems. While LGADs are optimized for the detection of minimum ionizing particles for high-energy particle detectors, it is critical to study their performance for the detection of different types of particle, such as X-rays, gamma-rays, or alphas. In this paper, we evaluate the gain of three types of LGADs: two devices with different geometries and doping profiles fabricated by Brookhaven National Laboratory, and one fabricated by Hamamatsu Photonics with a different process. Since the gain in LGADs depends on the bias voltage applied to the sensor, pulse-height spectra have been acquired for bias voltages spanning from the depletion voltage up to the breakdown voltage. Finally, the signal-to-noise ratio of the generated signals and the shape of their spectra allow us to probe the underlying physics of the multiplication process.

47 OTHER INSTRUMENTATION↗

One-electron redox kinetics of aqueous transition metal couples Zn 2+/+ , Co 2+/+ , and Ni 2+/+ using pulse radiolysis

The one-electron redox potentials for aqueous metal couples Co 2+/+ and Ni 2+/+ have been investigated by using pulse radiolysis using their reactions with a series of reference compounds to establish the most positive upper limits of E 0 . Experiments with Zn + were also carried out to confirm the characteristic shape of the expected reduction kinetics. Both formate ions and t-BuOH were employed to scavenge ˙OH radicals and ˙H atoms. Kinetics and fitted first and second order reaction rates have been reported for reactions with methyl viologen, fluorescein, Ru(NH 3 ) 6 3+ , Co(en) 3 2+ , Co(sepulcrate) 3+ , Ru(bpy) 3 2+ , Cr(bpy)33+, and Ni(Me 6 [14]4,11-dieneN4) 2+ . Previous work demonstrated that both Co 2+ and Ni 2+ can be reduced by CO 2 ˙- radicals, giving a negative E 0 limit of -1.9 V vs. SHE. A definite reaction of Ni + with fluorescein di-anions provides a new upper limit of the Ni 2+/+ couple as -0.906 V vs. SHE. The reaction of Co + with Ru(bpy) 3 2+ has been confirmed, giving E 0 = -1.3 V vs. SHE as a rigorous upper limit of the Co 2+/+ couple. In the case of Co 2+/+ , kinetics were complicated by a self-catalyzed metal clustering phenomenon. Initiation rate constants of this process have also been reported.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-accuracy absolute magnetometry with application to the Fermilab Muon g-2 experiment

We present details of a high-accuracy absolute scalar magnetometer based on pulsed proton NMR. The B-field magnitude is determined from the precession frequency of proton spins in a cylindrical sample of water after accounting for field perturbations from probe materials, sample shape, and other corrections. Features of the design, testing procedures, and corrections necessary for qualification as an absolute scalar magnetometer are described. The device was tested at B = 1.45 T but can be modified for a range exceeding 1–3 T. The magnetometer was used to calibrate other NMR magnetometers and measure absolute magnetic field magnitudes to an accuracy of 19 parts per billion as part of a measurement of the muon magnetic moment anomaly at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Press and Pulse of Climate Change: Extreme Events in the Colorado River Basin

Extremes in temperature and precipitation are associated with damaging floods, prolonged drought, destructive wildfires, agricultural challenges, compromised human health, vulnerable infrastructure, and threatened ecosystems and species. Often, the steady and progressive trends (or presses) of rising global temperature are the central focus in how climate impacts are described. However, observations of extreme weather events (or pulses) increasingly show that the intensity, duration and/or frequency of acute events are also changing, resulting in greater impacts on communities and the environment. Describing how the influence of extreme events may shape water management in the Colorado River Basin in clear terms is critical to sound future planning and efforts to manage risk. Three scenario planning workshops in 2019 and 2020 were held as part of a Colorado River Conversations series, identifying potential impacts from multiple intersecting extreme events. Water managers identified climate-related events of concern in the Colorado River Basin that necessitate greater attention and adaptive responses. To support efforts to include consideration of climate-change-driven extremes in water management and planning, we explore the current state of knowledge at the confluence of long-term climate shifts and extreme weather in the Colorado River Basin related to the events of concern that were identified by scenario planning participants.

54 ENVIRONMENTAL SCIENCES↗

Diagnostics of the technical condition of antifriction bearings

Shock pulse measurements that express the characteristic curves of rotational bearing resistance are used to diagnose possible deficiencies. Spectral analysis of frequency vibration tracings establishes probable causes for various anomalies in the geometric shape, surface frequency, contamination, etc.

Vitkute, A. E. Y.↗

Development of a high current density, high temperature superconducting cable for pulsed magnets

Abstract A low AC loss Rare Earth Barium Copper Oxide (REBCO) cable, based on the VIPER cable technology has been developed by Commonwealth Fusion Systems for use in high field, REBCO based tokamaks. The new cable is composed of partitioned and transposed copper ‘petals’ shaped to fit together in a circular pattern with each petal containing a REBCO tape stack and insulated from each other to reduce AC losses. A stainless steel jacket adds mechanical robustness—also serving as a vessel for solder impregnation—while a tube runs through the middle for cooling purposes. Additionally, fiber optic sensors are placed under the tape stacks for quench detection. To qualify this design, a series of experiments were conducted as part of the SPARC tokamak Central Solenoid Model Coil program—to retire the risks associated with full scale, fast ramping, high flux HTS Central Solenoid (CS) and Poloidal Field (PF) coils for tokamak fusion power plants and net energy demonstrators. These risk study and risk reduction experiments include (1) AC loss measurement and model validation in the range of ~5 T/s, (2) an IxB electromagnetic loading of over 850 kN/m at the cable level and up to 300 kN/m at the stack level, (3) a transverse compression resilience of over 350 MPa, (4) manufacturability at tokamak relevant speeds and scales, (5) cable to cable joint performance, (6) fiber optic based quench detection speed, accuracy, and feasibility, and (7) overall winding pack integration and magnet assembly. The result is a cable technology, now referred to as PIT VIPER, with AC losses that measure fifteen times lower (at ~5 T/s) than its predecessor technology; a 2% or lower degradation of critical current (Ic) at high IxB electromagnetic loads; no detectable Ic degradation up to 570 MPa of transverse compression on the cable unit cell; end to end magnet manufacturing, consistently producing Ic values within 7% of the model prediction; cable to cable joint resistances at 20 K on the order of ~15 nΩ; and fast, functional quench detection capabilities that do not involve voltage taps. This cable technology will be tested comprehensively in a Central Solenoid Model Coil to prove its readiness for compact, high field tokamak operation.

Sanabria, Charlie (ORCID:0000000150175309)↗

Studying Crystal Growth With the Peltier Effect

Peltier interface demarcation (PID) shown useful as aid in studying heat and mass transfer during growth of crystals from molten material. In PID, two dissimilar "metals" solid and liquid phases of same material. Current pulse passed through unidirectionally solidifying sample to create rapid Peltier thermal disturbance at liquid/solid interface. Disturbance, measured by thermocouple stationed along path of solidification at or near interface, provides information about position and shape of interface.

Larsen, David J., Jr.↗

Multifrequency laser beams for holographic contouring

Pulsed ruby laser emits two optical frequencies simultaneously so holographic recordings of test object give images showing desired range contours. Process enables generation of contour maps for practical applications such as gaging size and shape of mechanical parts and other structures.

Heflinger, L. O.↗

Measured and calculated fast neutron spectra in a depleted uranium and lithium hydride shielded reactor

Measurements of MeV neutron were made at the surface of a lithium hydride and depleted uranium shielded reactor. Four shield configurations were considered: these were assembled progressively with cylindrical shells of 5-centimeter-thick depleted uranium, 13-centimeter-thick lithium hydride, 5-centimeter-thick depleted uranium, 13-centimeter-thick lithium hydride, 5-centimeter-thick depleted uranium, and 3-centimeter-thick depleted uranium. Measurements were made with a NE-218 scintillation spectrometer; proton pulse height distributions were differentiated to obtain neutron spectra. Calculations were made using the two-dimensional discrete ordinates code DOT and ENDF/B (version 3) cross sections. Good agreement between measured and calculated spectral shape was observed. Absolute measured and calculated fluxes were within 50 percent of one another; observed discrepancies in absolute flux may be due to cross section errors.

Lahti, G. P.↗

NASA Tech Briefs, December 2008

Topics covered include: Crew Activity Analyzer; Distributing Data to Hand-Held Devices in a Wireless Network; Reducing Surface Clutter in Cloud Profiling Radar Data; MODIS Atmospheric Data Handler; Multibeam Altimeter Navigation Update Using Faceted Shape Model; Spaceborne Hybrid-FPGA System for Processing FTIR Data; FPGA Coprocessor for Accelerated Classification of Images; SiC JFET Transistor Circuit Model for Extreme Temperature Range; TDR Using Autocorrelation and Varying-Duration Pulses; Update on Development of SiC Multi-Chip Power Modules; Radio Ranging System for Guidance of Approaching Spacecraft; Electromagnetically Clean Solar Arrays; Improved Short-Circuit Protection for Power Cells in Series; Electromagnetically Clean Solar Arrays; Logic Gates Made of N-Channel JFETs and Epitaxial Resistors; Improved Short-Circuit Protection for Power Cells in Series; Communication Limits Due to Photon-Detector Jitter; System for Removing Pollutants from Incinerator Exhaust; Sealing and External Sterilization of a Sample Container; Converting EOS Data from HDF-EOS to netCDF; HDF-EOS 2 and HDF-EOS 5 Compatibility Library; HDF-EOS Web Server; HDF-EOS 5 Validator; XML DTD and Schemas for HDF-EOS; Converting from XML to HDF-EOS; Simulating Attitudes and Trajectories of Multiple Spacecraft; Specialized Color Function for Display of Signed Data; Delivering Alert Messages to Members of a Work Force; Delivering Images for Mars Rover Science Planning; Oxide Fiber Cathode Materials for Rechargeable Lithium Cells; Electrocatalytic Reduction of Carbon Dioxide to Methane; Heterogeneous Superconducting Low-Noise Sensing Coils; Progress toward Making Epoxy/Carbon-Nanotube Composites; Predicting Properties of Unidirectional-Nanofiber Composites; Deployable Crew Quarters; Nonventing, Regenerable, Lightweight Heat Absorber; Miniature High-Force, Long-Stroke SMA Linear Actuators; "Bootstrap" Configuration for Multistage Pulse-Tube Coolers; Reducing Liquid Loss during Ullage Venting in Microgravity; Ka-Band Transponder for Deep-Space Radio Science; Replication of Space-Shuttle Computers in FPGAs and ASICs; Demisable Reaction-Wheel Assembly; Spatial and Temporal Low-Dimensional Models for Fluid Flow; Advanced Land Imager Assessment System; Range Imaging without Moving Parts.

Source record↗

Laser Ablation Electrodynamic Ion Funnel for In Situ Mass Spectrometry on Mars

A front-end instrument, the laser ablation ion funnel, was developed, which would ionize rock and soil samples in the ambient Martian atmosphere, and efficiently transport the product ions into a mass spectrometer for in situ analysis. Laser ablation creates elemental ions from a solid with a high-power pulse within ambient Mars atmospheric conditions. Ions are captured and focused with an ion funnel into a mass spectrometer for analysis. The electrodynamic ion funnel consists of a series of axially concentric ring-shaped electrodes whose inside diameters (IDs) decrease over the length of the funnel. DC potentials are applied to each electrode, producing a smooth potential slope along the axial direction. Two radio-frequency (RF) AC potentials, equal in amplitude and 180 out of phase, are applied alternately to the ring electrodes. This creates an effective potential barrier along the inner surface of the electrode stack. Ions entering the funnel drift axially under the influence of the DC potential while being restricted radially by the effective potential barrier created by the applied RF. The net result is to effectively focus the ions as they traverse the length of the funnel.

Johnson, Paul V.↗

In-Flight Performance of the Mercury Laser Altimeter Laser Transmitter

The Mercury Laser Altimeter (MLA) is one of the payload instruments on the MErcury Surface, Space ENvironment, GEochemistry, and Ranging (MESSENGER) spacecraft, which was launched on August 3, 2004. MLA maps Mercury's shape and topographic landforms and other surface characteristics using a diode-pumped solid-state laser transmitter and a silicon avalanche photodiode receiver that measures the round-trip time of individual laser pulses. The laser transmitter has been operating nominally during planetary flyby measurements and in orbit about Mercury since March 2011. In this paper, we review the MLA laser transmitter telemetry data and evaluate the performance of solid-state lasers under extended operation in a space environment.

altimeter↗