High-Performance CO 2 Capture from Air by Harnessing the Power of CaO- and Superbase-Ionic-Liquid-Engineered Sorbents

Direct air capture (DAC) of CO 2 by solid porous materials represents an attractive “negative emission” technology. However, state-of-the-art sorbents based on supported amines still suffer from unsolved high energy consumption and stability issues. For this work, taking clues from the CO 2 interaction with superbase-derived ionic liquids (SILs), high-performance and tunable sorbents in DAC of CO 2 was developed by harnessing the power of CaO- and SIL-engineered sorbents. Deploying mesoporous silica as the substrate, a thin CaO layer was first introduced to consume the surface-OH groups, and then active sites with different basicities (e. g., triazolate and imidazolate) were introduced as a uniformly distributed thin layer. The as-obtained sorbents displayed high CO 2 uptake capacity via volumetric (at 0.4 mbar) and breakthrough test (400 ppm CO 2 source), rapid interaction kinetics, facile CO 2 releasing, and stable sorption/desorption cycles. Operando diffuse reflectance infrared Fourier transformation spectroscopy (DRIFTS) analysis under simulated air atmosphere and solid-state NMR under 13 CO 2 atmosphere demonstrated the critical roles of the SIL species in low-concentration CO 2 capture. The fundamental insights obtained in this work provide guidance on the development of high-performance sorbents in DAC of CO 2 by leveraging the combined advantages of porous solid scaffolds and the unique features of CO 2 -philic ionic liquids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cost-optimal evaluation of centralized and distributed microgrid topologies considering voltage constraints

Optimal design of hybrid renewable mini-grids requires both economic and power quality considerations. Existing modeling approaches address these considerations via separate or loosely coupled models. Here, we extend REopt—a techno-economic optimization model developed at the National Renewable Energy Laboratory—to consider both within a single model. REopt formulates the design problem as a mixed-integer linear program that solves for a site's optimal technology mix, sizing, and operation to minimize life cycle cost. REopt has traditionally assumed a single node system. In the work presented here, we expand the REopt platform to consider multiple connected nodes with associated voltage constraints. In order to do this, we model power flow using a fixed-point linear approximation method. Additionally, we then use the model to explore design considerations of mini-grids in Sub-Saharan Africa. Specifically, we evaluate under what combinations of transmission line distance and capacity it is technically viable and economically preferable to build multiple isolated mini-grids versus an interconnected, centralized system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Power Supply Options for the Marpi Landfill, Saipan: Feasibility Study

The Marpi Landfill, located on the northern end of the island of Saipan in the Commonwealth of the Northern Mariana Islands (CNMI), is powered by an on-site diesel generator that only operates when the landfill is open and staffed. The CNMI Office of Planning and Development (OPD) aspires to provide the Marpi Landfill with 24-hour power availability despite its remote location and to increase the use of sustainable energy within the CNMI. CNMI has a 20% target for renewable energy consumption, as documented in Sustainable Development Goal #7 in the Comprehensive Sustainable Development Plan (OPD 2021) and the renewable portfolio standard (GPO 2014). To accomplish these goals, the U.S. Department of Energy, through its Interagency Reimbursable Work Agreement with the Federal Emergency Management Agency, funded this feasibility study to assess and prioritize power supply options for the landfill. The availability of solar and wind resources varies seasonally, as does the load. A BESS can help to balance mismatches between generation and load on short (hourly or daily) timescales, but not across seasons. The microgrid scenarios evaluated for Marpi consider options for technology combinations that will both meet the load and utilize available resources, despite the challenge presented by higher loads and lower solar and wind availability during the rainy season, depicted in Figure ES-2. The seven scenarios evaluated are summarized in Table ES-1. Each scenario’s configuration was optimized to include component capacities that reduce capital and operating costs, meet the load, and minimize carbon emissions, as feasible. The costs and levelized cost of energy (LCOE) shown do not assume the use of any grant funding or incentives, although these options were also evaluated. To assist with decision-making, a prioritization matrix (Table ES-3) was created to compare the microgrid scenarios evaluated in this feasibility study according to various stakeholder priorities. The prioritization metrics were chosen based on discussions with OPD and will be finalized through stakeholder feedback. The scenarios were given a score between 1 and 7 for each prioritization metric (the lower the score, the higher the priority), and total scores were calculated using assigned weights based on the relative priority of each metric. The total scores were then ranked to produce a prioritized list of microgrid scenarios based on the metrics most important to the project stakeholders. As shown, scenario 4 (100 kW of solar PV, a 75 kW/300 kWh BESS, and 160 kW of diesel generation) ranks highest.

14 SOLAR ENERGY↗

Biopower: Impact of Biofuels Deployment to Replace Petroleum Liquids in Stationary Power Applications

Petroleum-based liquids are used in a portion of power generation applications in the United States, predominantly in the New England, Middle Atlantic, South Atlantic, and Pacific-Noncontiguous regions. Power plants that burn petroleum liquids, such as distillate or residual fuel oils, are generally used for short periods to accommodate peak electricity demands. The Energy Information Administration (EIA) estimated the U.S. consumption of petroleum liquids for electricity generation at 27 million barrels in 2018, representing a cost of $2.4 billion annually. This study assesses the potential to displace all or part of the petroleum liquids in U.S. power generation with biofuels. The biofuels for this application are assumed to be derived from terrestrial feedstocks, with conversion routes of both fast pyrolysis (bio-oil) and hydrothermal liquefaction (bio-crude). Regional models were used to assess the availability and cost of three different base materials: clean wood, forest residues, and corn stover; each was evaluated in the laboratory at small or experimental scales for conversion to bio-oil or bio-crude. The estimated biofuel production quantities depend on equivalent heating versus the current heavy fuel. In this report, the availability of each type of biomass for each section of the U.S. Census division is estimated using a conservative broker price (in each case) of $ 80 per dry tonne. The results show that the petroleum-liquid power generation in each of the Census Divisions could be supplied by one or more of the feedstocks evaluated. For all regions, clean wood supplies (only) could provide ample supply. For all but two regions (Middle Atlantic and New England), forest residues alone are sufficient. Finally, for all regions but three (Middle Atlantic, New England, and South Atlantic), corn stover alone is adequate. The Minimum Fuel Selling Price (MFSP) of bio-oil and bio-crude were also estimated for each feedstock type and Census Division. This analysis showed that fast pyrolysis bio-oil projections to be lower (14% on average) than current wholesale petroleum-based heating oil prices in each of the regions, assuming 100 dry tonnes/day processing capacity. However, bio-crude predictions were significantly higher (2X) in all cases. The effect of biorefinery size was also quantified. Based on the preliminary results in this study, it is apparent the biofuels could be an economical alternative for current petroleum liquids in U.S. power generation. However, additional research is needed to determine the necessary biofuel characteristics to support existing generation equipment. It is recommended that both power generation and biofuel production stakeholders to be engaged to outline the research and testing needed to identify the technical hurdles to enable the opportunity.

02 PETROLEUM↗

A one-pot synthesis of high-density biofuels through bifunctional mesoporous zeolite-encapsulated Pd catalysts

Developing a powerful bifunctional catalyst for tandem reactions is essential to the future carbon neutrality by reducing the energy consumption in chemical industries. Herein, mesoporous zeolite-encapsulated palladium (Pd) nanoparticles (Pd@meso-ZSM-5) synthesized via emulsification-demulsification followed by a dry-gel transformation method were demonstrated to have a remarkable catalytic performance for a one-pot multiple tandem reaction of cyclic ketones (cyclopentanone, cyclohexanone) to bicyclic alkanes (bicyclopentane, bicyclohexane). Compared with supported catalysts (Pd/meso-ZSM-5) and microporous zeolite-encapsulated catalysts (Pd@ZSM-5) with a primary product of monocyclic alkane (cyclopentane, cyclohexane), Pd@meso-ZSM-5 shows much higher catalytic efficiency for the bicyclic alkanes synthesis, which was previously unattainable in the conventional two-step synthesis route. Controlled experiments and detailed characterizations show that mesoporosity provides sufficient space for the generation and diffusion of large molecular intermediates, and the intimate acid-Pd interface promotes the conversion of intermediates. As a result, this work proposes a design strategy for a mesoporous zeolite-encapsulated metal catalyst, which efficiently provides cooperative acid-hydrogenation catalysis.

09 BIOMASS FUELS↗

Exploring the Influence of Linker Substitution and Ratios on Cooperative Framework Flexibility through the Mixed-Linker Approach

Cooperatively flexible metal–organic frameworks that exhibit step-shaped, or Type V-like, adsorption–desorption profiles can lower requisite pressure–temperature swings and thus energy input, necessary for an array of gas storage, delivery, and separations applications. However, such benefits are lost if the pressure threshold of the adsorption and desorption steps at a given temperature does not match the conditions dictated by the application, such as H 2 storage and delivery or olefin–paraffin separations. Unfortunately, the discovery of cooperatively flexible frameworks remains wholly serendipitous and de novo design remains impossible. Accordingly, there is a great need to further our understanding of flexibility such that we can intuitively derivatize known frameworks and, ultimately, design entirely new ones to meet the requisite conditions of energy-consumptive processes. In this work, we demonstrate that the mixed-linker, or multivariate, approach is a powerful tool for the derivation of a known flexible framework, with variances in linker substitution and ratio giving rise to a family wherein significant changes to the step-shaped adsorption–desorption profiles for multiple adsorbates are observed. Specifically, we report 12 isostructural mixed-linker derivatives of CdIF-13 (sod–Cd(benzimidazolate) 2 ) with six point-modified benzimidazole linkers spontaneously synthesized through prototypical solvothermal conditions. Furthermore, each is shown by PXRD to exhibit similar reversible flexibility to CdIF-13 and by TGA and DSC to be similarly thermally stable. Isothermal gas adsorption measurements with N 2 at 77 K, CO 2 at 195 K, and propane at 298 K demonstrate the wide-ranging, adsorbate-dependent effects of linker substitution and ratio, including dramatic reductions in the adsorption threshold pressure, evolution of multiple steps, and complete absence of observable adsorption. Aided by prior crystallographic characterization of CdIF-13, the observed trends were analyzed in an attempt to resolve the influence of linker substitution and ratios on structural behavior. In total, this work illustrates how the mixed-linker approach enables the synthesis and study of a large catalog of functionally modified frameworks, which can help identify the variables that influence flexibility and sorption behavior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real-Time Ecodriving Control in Electrified Connected and Autonomous Vehicles Using Approximate Dynamic Programing

Connected and automated vehicles (CAVs), particularly those with a hybrid electric powertrain, have the potential to significantly improve vehicle energy savings in real-world driving conditions. In particular, the ecodriving problem seeks to design optimal speed and power usage profiles based on available information from connectivity and advanced mapping features to minimize the fuel consumption over an itinerary. This paper presents a hierarchical multilayer model predictive control (MPC) approach for improving the fuel economy of a 48 V mild-hybrid powertrain in a connected vehicle environment. Approximate dynamic programing (DP) is used to solve the receding horizon optimal control problem, whose terminal cost is approximated with the base policy obtained from the long-term optimization. The controller was tested virtually (with deterministic and Monte Carlo simulation) across multiple real-world routes, demonstrating energy savings of more than 20%. The controller was then deployed on a test vehicle equipped with a rapid prototyping embedded controller. In-vehicle testing confirm the energy savings obtained in simulation and demonstrate the real-time ability of the controller.

Automation & Control Systems↗

Microelectronics at the Department of Energy: Capabilities and Opportunities for Driving U.S. Competitiveness

Microelectronics are everywhere—embedded in our consumer products; underlying our power, transportation, and information infrastructure; and fortifying our national security. These and other microelectronics applications are also intricately linked with America’s energy and decarbonization goals. For instance, advanced power electronics are critical to our transition to renewable power and electric transport, and more energy-efficient computing and consumer devices are needed as energy consumption grows rapidly. Meanwhile, global supply chain disruptions beginning in 2020 and the ensuing chip shortage caused by the COVID-19 pandemic highlight the vulnerability of microelectronics supply chains. The globally distributed manufacturing base can be disrupted in unexpected ways, and there is no single solution to these challenges given the range of applications and technologies within the microelectronics industry—from ever-smaller, nanoscale feature sizes to large-scale commodity use cases to specialized functionalities. Rather, solutions will require the private sector, federal agencies, and research and development (R&D) organizations such as labs and universities to act in concert beyond their individual missions.

36 MATERIALS SCIENCE↗

Systems Analysis of Biomass and Coal Co-firing Power Plants with Deep Carbon Capture Toward Net-zero Emissions

Achieving a net-zero emission economy in the United States requires integrating diverse low-carbon and negative-emission technologies into the existing fossil fuel-dominant power fleet. Potential technologies from the low-carbon portfolio include renewable power, fossil power with carbon capture and storage (CCS), bioenergy with CCS (BECCS), and direct air capture (DAC). Renewable power is a clean energy source but has to pair with costly battery storage to provide dispatchable electricity. Fossil power with CCS offers dispatchable electricity yet still relies on DAC to offset residual emissions, even when deploying deep CCS with more than 90% CO2 capture. Coal-biomass co-firing with CCS, a subset of BECCS, is a reliable energy production technology that can be retrofitted from existing electricity generation units (EGUs). Power plant retrofit maximizes the use of the current U.S. coal power fleet without the need for large-scale deployment of new renewable power, battery storage, or DAC. Retrofitting coal-biomass co-firing with deep CCS in EGUs is a promising option, but not a universal solution. Biomass co-firing at a power plant introduces economic challenges and indirectly poses pressure on land and water resources. Meanwhile, retrofitting deep CCS affects plant efficiency and raises electricity generation costs. Overall, the technical feasibility and economic viability of plant retrofits vary across EGUs, as they are contingent upon the regional availability of biomass, unit-specific characteristics, site-specific fuel supply costs, and adjacent CO2 storage potential. Government incentives like 45Q can improve the retrofit viability, though the impact requires further quantification. A comprehensive analysis at the unit level is essential to address the question regarding the fate of the U.S. coal-fired electricity generation fleet toward the net-zero emission goal. This study conducts a systematic techno-economic-environmental assessment of EGUs to identify the viability of biomass co-firing and deep CCS retrofits in the U.S. coal-fired power fleet. Specifically, it characterizes the techno-economic performance of deep carbon capture, estimates life cycle greenhouse gas (GHG) emissions, and conducts a fleet-level assessment on retrofit viability. The key objectives are (1) to estimate the unit-specific performance and retrofitted cost under various biomass co-firing levels and CO2 capture rates; (2) to determine the possibility of reaching net-zero emission at the fleet level; (3) to quantify the cumulative capacities that are suitable for plant retrofits under current and future biomass supply scenarios; and (4) to improve the understanding of policy impacts on such retrofits to help the power sector’s transition to a net-zero economy. Techno-economic Model of Deep Carbon Capture. This study develops the performance and economic models for Monoethanolamine-based post-combustion CO2 capture at 95–99% capture rates. The process is simulated in Aspen Plus, analyzing the performance of carbon capture technology by varying the plant sizes, solvent lean loading, CO2 concentrations, and flue gas inlet temperature. Based on the key inputs and output parameters of CO2 capture, a reduced-order performance model of deep carbon capture is formulated. In addition, an engineering-economic model integrating the performance metrics is developed to estimate the capital as well as operation and maintenance (O&M) costs. Capital cost estimations follow the framework of the Integrated Environmental Control Model (IECM) and incorporate data regressions from three technical reports by IECM, the National Energy Technology Laboratory (NETL), and the National Renewable Energy Laboratory. The O&M cost estimation utilizes the actual inventory consumption rate and labor requirements. Both performance and cost models are embedded into IECM v13.0-beta, a fossil-fuel power plant modeling tool. Life Cycle Assessment of Power Plants. This study estimates the GHG emissions of power plants through life cycle assessment (LCA). The LCA scope includes fuel supply, combustion-based power generation, and CO2 transport and storage. The fuel-based life cycle module is designed following the framework of the NETL Unit Process Library and CO2U LCA Guidance Toolkit. The module is then incorporated into IECM v13.0-beta. The process-based LCA is applied to estimate the GHG emissions of coal and biomass supply, coal- and coal-biomass co-firing power plant operation, as well as CO2 pipeline transport and geographical sequestration. An uncertainty analysis is conducted to quantify the variability and uncertainty associated with the LCA using the Latin Hypercube Sampling (LHS) method. Fleet-level Assessment. This study evaluates the technical and economic feasibility of selected coal-fired EGUs, examines the role of tax credits in retrofit viability, and assesses the competitiveness of retrofitted units against other low-carbon options. Unit screening identifies EGUs for the study, focusing on new, efficient baseload units with air pollution controls. The power plant databases are then established to organize unit-specific information on performance and operating conditions from the relevant public databases. Biomass for co-firing retrofits is selected based on home and neighboring county availability, ensuring sustained operation with at least a 5% co-firing level. The CO2 storage site is determined by state-level storage potential, with ArcGIS Pro and NETL CO2 Saline Storage Cost Model used to identify the optimal balance between the nearest transport distances and affordable storage costs. The latest IECM v13.0-beta is then employed to configure and evaluate the eligible EGUs with or without the deployment of deep CCS and biomass co-firing. A supply curve is established to illustrate the cumulative installed capacity suitable for retrofits at different cost levels. A sensitivity analysis on tax credits for carbon sequestration is performed. Finally, a unit-level cost comparison is conducted among retrofitted plants, renewable power with battery storage, and abated fossil fuels with DAC. Expected Results. This study evaluates the technical, economic, and environmental metrics of each EGU across an array of CO2 capture rates and biomass co-firing level scenarios. Unit-level comparisons will identify critical factors influencing technical performance. The supply curves with and without tax incentives will provide insights into the impact of tax credits on biomass co-firing and CCS deployment. The cost comparisons with renewables and DAC-retrofit will assess the competitiveness of the retrofitted units. Life cycle emissions from each unit will be assessed to identify the scenarios under which net-zero emissions can be achieved. These analyses are expected to determine the total coal-fired capacity suitable for serving as a low-carbon energy source with or without tax incentives. The study results are novel in identifying optimal unit-specific strategies for producing carbon-neutral power, whether through retrofitting EGUs with deep CCS, biomass co-firing, DAC, or installing renewable power with battery. The findings will provide insight into nationwide efforts to ensure reliable, affordable, and low-carbon electricity. It also will inform investment decisions and policies in the deployment of deep carbon capture and negative emission technologies for a net-zero energy future.

Biomass Co-firing↗

WHISPER: Wireless Home Identification and Sensing Platform for Energy Reduction

Many regions of the world benefit from heating, ventilating, and air-conditioning (HVAC) systems to provide productive, comfortable, and healthy indoor environments, which are enabled by automatic building controls. Due to climate change, population growth, and industrialization, HVAC use is globally on the rise. Unfortunately, these systems often operate in a continuous fashion without regard to actual human presence, leading to unnecessary energy consumption. As a result, the heating, ventilation, and cooling of unoccupied building spaces makes a substantial contribution to the harmful environmental impacts associated with carbon-based electric power generation, which is important to remedy. For our modern electric power system, transitioning to low-carbon renewable energy is facilitated by integration with distributed energy resources. Automatic engagement between the grid and consumers will be necessary to enable a clean yet stable electric grid, when integrating these variable and uncertain renewable energy sources. We present the WHISPER (Wireless Home Identification and Sensing Platform for Energy Reduction) system to address the energy and power demand triggered by human presence in homes. The presented system includes a maintenance-free and privacy-preserving human occupancy detection system wherein a local wireless network of battery-free environmental, acoustic energy, and image sensors are deployed to monitor homes, record empirical data for a range of monitored modalities, and transmit it to a base station. Several machine learning algorithms are implemented at the base station to infer human presence based on the received data, harnessing a hierarchical sensor fusion algorithm. Results from the prototype system demonstrate an accuracy in human presence detection in excess of 95%; ongoing commercialization efforts suggest approximately 99% accuracy. Using machine learning, WHISPER enables various applications based on its binary occupancy prediction, allowing situation-specific controls targeted at both personalized smart home and electric grid modernization opportunities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bioenergy pathways within United States net-zero CO 2 emissions scenarios in the Energy Modeling Forum 37 study

The Energy Modeling Forum 37 study is organized around carbon dioxide (CO 2 ) mitigation scenarios reaching net-zero CO 2 emissions by 2050 in the United States. Here, this paper summarizes the potential contribution of bioenergy use in the electric power, transportation, industrial, and buildings sectors toward meeting that target based on model results. Thirteen modeling teams reported bioenergy consumption in the Reference and Net Zero scenarios. Consumption of bioenergy increased over time in the Reference scenario, from an average across models of 3.2 exajoules (EJ) in 2020 to 3.8 EJ in 2050. Average bioenergy consumption in 2050 increased further to 7.3 EJ in the Net Zero scenario. All scenarios that reach net-zero emissions required some form of carbon dioxide removal to offset emissions that are difficult to reduce. Carbon dioxide removal using bioenergy with CO 2 capture and storage (BECCS) varies widely across models, up to 1000 Mt CO 2 in 2050. Some models rely instead on direct air carbon capture and storage (DACCS), up to 2200 Mt CO 2 , and others use a combination of BECCS and DACCS. Model results show a strong inverse relationship between the amounts of BECCS and DACCS deployed. All modeling teams assumed a carbon sink from land use, land use change, and forestry, further offsetting a portion of emissions from fossil fuels and industry that are expensive to eliminate. Bioenergy consumption in 2050 decreased by an average of 1.5 EJ across eight models in a Net Zero+ scenario relative to the Net Zero scenario, due in part to a lower equilibrium carbon price resulting from optimistic cost assumptions for all energy technologies.

09 BIOMASS FUELS↗

Review of hybrid HVDC systems combining line communicated converter and voltage source converter

Hybrid HVDC system, which consists of the advantages of line commutated converter (LCC) and voltage source converter (VSC), is an emerging power transmission system. This paper presents a review of four LCC-VSC hybrid HVDC topologies. The first topology is the pole-hybrid HVDC system, in which the LCC and VSC form the positive- and negative-pole respectively. The second one is the terminal-hybrid HVDC system; in this topology one terminal adopts LCC and the other terminal adopts VSC. The series converter-hybrid HVDC system is the third topology wherein each terminal is formed by LCC and VSC in series. The fourth hybrid topology under consideration is a parallel converter-hybrid HVDC system with LCC and VSC connected in parallel in each terminal. Here, the main contribution of this paper is a comprehensive analysis and comparison of the four mentioned hybrid topologies in terms of PQ operating zone, power flow reversal method, and DC fault ride-through strategy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal Integration of Advanced Nuclear Reactors with a Reference Refinery, Methanol Synthesis, and a Wood Pulp Plant (Rev.1)

The present report is intended to provide process flow diagrams (PFDs) and energy and mass balance data sheets for a U.S. industrial sector subset with which nuclear heat and power could be integrated—a subset that includes the oil refining, methanol and pulp and paper industries. Coupling options for integrating nuclear energy into these industries are quantitatively outlined for reference systems, and future work will extend this analysis in greater detail. Opportunities for integrating small modular nuclear reactors (SMNRs) were investigated for each of the industrial process configurations. Aspen HYSYS and Cycle-Tempo models for a high-temperature gas-cooled reactor were developed to evaluate the proposed integration. This introductory evaluation provides a general description and assessment of the operating principles, reactor coolant core outlet temperature, and reactor size to be integrated with industry. The industrial processes of oil refining and the production of methanol, pulp and paper were simulated by using Aspen HYSYS, Aspen Plus, and the PRELIM (Petroleum Refinery Life Cycle Inventory Model) tool to develop process details. Cycle-Tempo models then extend the process modeling results to obtain net energy demands (e.g., heat, steam, and electricity) when accounting for process steam and waste heat recovery. This information is intended to foster the analysis of integrating an SMNR to decarbonize industrial facilities. The SMNR would provide reliable, competitive, and sustainable clean energy while reducing carbon emissions and other environmental impacts, such as water withdrawals, consumption, and contamination. The refining industry, exhibited in Figure ES1, is a leading consumer of fossil -fuel-based heat, power, and hydrogen in the U.S. industrial sector, generating over 164 million metric tons (MMT) of CO 2 emissions in 2023. The overall mass and energy pertaining to a generalized complex refinery in the United States is reflected in Figure ES1, along with energy metrics regarding integration with a nuclear power plant (NPP). Data sheets were developed to indicate the energy requirements for the overall refinery and each refinery process. The data sheet for the overall refinery is shown in Table ES2.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Self-consumption for energy communities in Spain: A regional analysis under the new legal framework

European climate polices acknowledge the role that energy communities can play in the energy transition. Self-consumption installations shared among those living in the same building are a good example of such energy communities. In this work, a regional analysis of optimal self-consumption installations under the new legal framework recently passed in Spain is performed. Results show that the optimal sizing of the installation leads to economic savings for self-consumers in all the territory, for both options with and without remuneration for energy surplus. A sensitivity analysis on technology costs revealed that batteries still require noticeably cost reductions to be cost-effective in a behind the meter self-consumption environment. In addition, solar compensation mechanisms make batteries less attractive in a scenario of low PV costs, since feeding PV surplus into the grid, yet less efficient, becomes more cost-effective. Furthermore, an improvement for the energy surplus remuneration policy in the context of the current legislation was proposed and analysed. It consists in the inclusion of the economic value of the avoided power losses in the remuneration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A method for assessing economic, environmental, and reliability tradeoffs of interregional transmission connecting ERCOT (the Texas grid) to the eastern and western grids

Reliable development of the power grid is an evolving concern for humanity due to extreme weather that frequently threatens power sector infrastructure. The state of Texas is a uniquely structured testbed for grid planners to study when looking for solutions to development, innovation, and overcoming such challenges. Because of its size and islanded structure, Texas is small enough to model, but big enough to matter. Texas is a global leader in energy production, energy consumption, and maintains an unusually diverse fuel mix. In addition, the state has experienced winter freezes, heat waves, wind storms, droughts and floods that have threatened power sector infrastructure or caused recent blackouts and calls for demand side conservation. One of the most devastating of these events was the North American winter storm, dubbed “Winter Storm Uri” by the Weather Channel, that froze the region in February 2021 and led to an extended power outage event that put the majority of Texan residents in darkness for days. While preparing to avoid such outage events in the future, various tools have been proposed to improve grid reliability, including energy efficiency, demand response, and distributed energy resources. An additional option would be to develop interregional transmission that connects the Texas grid to other national grids. To assess the merits of this idea, we developed a novel, universally-applicable and internationally-relevant framework to study how the Texas grid would evolve alongside access to various interregional ties. This method allows us to stress the synthetic grid structure and analyze how it would respond to the shock of a simulated winter storm event. Our method leverages open-source modeling tools, such as PowerGenome, pyGRETA, and GenX to synthesize unique zonal grid data, construct a consolidated network of model regions, and simulate different developmental pathways of capacity expansion and operational dispatch. We demonstrate our method with an analysis connecting the Electric Reliability Council of Texas (ERCOT), the grid that serves most of Texas, the Western Electricity Coordinating Council (WECC), the grid that serves the western half of the contiguous U.S., and the Eastern Interconnect, the grid that serves the eastern half of the contiguous U.S. Our results indicate that the cost-optimal capacity of interregional transmission connecting the ERCOT grid to other grids lies between 9–13 GW assuming baseline conditions. Building this amount of connecting capacity in one or multiple directions lowers the costs and emissions of development and operation by up to $16 billion and 257 million metric tonnes (MMT) respectively. Additionally, our results show that the interregional connections between ERCOT and other national grids reduce the amount of total load shed required through mild winter storm events. However, our results also show that there is a threshold of very extreme winter storm conditions, spanning multiple service areas, above which the connections exacerbate resource adequacy problems. Therefore, the results indicate that the connections need to be carefully planned alongside the rest of the grid infrastructure to avoid over-reliance on specific resources or technology options.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Next Generation Durable, Cost Effective, Energy Efficient Tubular SOFC (Final Scientific/Technical Report)

The overall objective of this project is to develop and optimize a YSZ electrolyte-based solid oxide fuel cell (SOFC) technology for low cost, low temperature (~ 650°C), and high energy efficiency operation. The developed technology will be implemented and demonstrated in a high efficiency 2~3kW SOFC with applicability to sub-MW systems. A summary of significant accomplishments is provided below. Key accomplishments: 1. Improved fundamental cell technology demonstrated at single tube and system scale. Improved power output by 54% while operating at the normal temperature of 750°C. And improved power output by 33% while operating at 650°C, 100°C lower than normal temperature. 2. SPS patented internal recycle arrangement was developed and extended to operate on LPG fuel directly in a compact, high-efficiency (> 40%) system. 3. System testing was conducted to prove the long-term durability of cell improvements. Demonstrated over 8000 hours of operation at 0.21 %/1000 hrs degradation. 4. A large-scale, 2.5kW net power system demonstration was completed, which demonstrated 40% net efficiency over 1000 hours. 5. System design and cost analysis of a 1MW system utilizing a 2.5kW bundle was completed. Cost optimization of the bundle showed a reduction of nearly 80% is possible from $\$$5,790/kW to $\$$1250/kW. This lower cost is considered viable for SPS commercialization.

03 NATURAL GAS↗

Effects of Climate Change on Capacity Expansion Decisions of an Electricity Generation Fleet in the Southeast U.S.

The electric power sector in the United States faces many challenges related to climate change. On the demand side, climate change could shift demand patterns due to increased air temperatures. On the supply side, climate change could lead to deratings of thermal units due to changes in air temperature, water temperature, and water availability. Past studies have typically analyzed these risks separately. Here, we developed an integrated, multimodel framework to analyze how compounding risks of climate-change impacts on demand and supply affect long-term planning decisions in the power system. In the southeast U.S., we found that compounding climate-change impacts could result in a 35% increase in installed capacity by 2050 relative to the reference case. Participation of renewables, particularly solar, in the fleet increased, driven mostly by the expected increase in summertime peak demand. Such capacity requirements would increase investment costs by approximately 31 billion (USD 2015) over the next 30 years, compared to the reference case. These changes in investment decisions align with carbon emission mitigation strategies, highlighting how adaptation and mitigation strategies can converge.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Off-design operation and performance of pumped thermal energy storage

In this article, we describe off-design models and control strategies for a Pumped Thermal Energy Storage (PTES) system that uses liquid thermal energy storage: specifically molten salt for hot storage and methanol for cold storage. Off-design conditions arise when load-following, or due to variations in storage tank temperatures or ambient temperatures. We propose a control strategy that uses inventory control to manage the mass flow rate in the thermodynamic cycles, which facilitates load following. We also propose a control strategy for the storage fluid mass flow rates, which are varied to ensure the molten salt is maintained at its design temperature. This maximizes efficiency and minimizes problems with salt freezing or degradation. The cold storage fluid mass flow rate is varied so that the cold tanks have the same state-of-charge as the hot tanks. This leads to variations in cold fluid temperature, but these variations are shown to be acceptably small (e.g. 7.5% increase), and this control method is shown to be simpler and more efficient than an alternative strategy where tanks become unbalanced. The ambient temperature and storage tank temperatures are moved ±50 °C from the design values and the impact on power, duration, and tank temperatures is quantified. Results demonstrate that the proposed control strategy is stable and self-correcting - that is, storage temperatures converge on stable values after two-to-three charge-discharge cycles. When inputs return to design values, the system returns to its design point after two charge-discharge cycles. We also demonstrate that inventory control enables delivery of the target power output even when off-design conditions exist that would normally reduce the power output.