Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Structural, magnetic, optical, dielectric and electronic properties of R 2 NiIrO 6 (R = Pr and Nd): A comprehensive experimental and theoretical investigation

Double perovskites are highly promising materials capable of exhibiting a wide variety of phenomena. In this work, we perform a comprehensive experimental and theoretical study of polycrystalline R 2 NiIrO 6 (R = Pr and Nd) compounds. Both compounds were synthesised using the solid-state reaction method. Rietveld refinement confirmed a monoclinic structure with the P2 1 /n space group for both compounds. The scanning electron images showed the average grain sizes of 0.55 μm for R = Pr and 0.46 μm for R = Nd. Fourier transform infrared ra- diation spectra of the two compounds presented two intense bands at 470 cm -1 and 540 cm -1 . The optical measurements revealed that the band gaps of the compounds were in the visible absorption range. The field- cooled magnetisation - field hysteresis measurements indicated exchange bias properties in the synthesised compounds at low temperatures. Both temperature and frequency variation of dielectric constant and loss tangent measurements were conducted. The frequency-dependent ac conductivity measurements indicated that the conductivity increases with the increase of frequency as well as temperature. The Nd 2 NiIrO 6 compound showed lower ac conductivities compared to its isostructural Pr 2 NiIrO 6 compound. The atomic and electronic structures of Nd 2 NiIrO 6 and Pr 2 NiIrO 6 were explored using the spin-polarised calculations performed within the DFT+U method. Our results suggested that the inclusion of on-site correlations and repulsions for the d-states of atoms was necessary in order to obtain finite band gaps of Nd 2 NiIrO 6 and Pr 2 NiIrO 6 systems.

36 MATERIALS SCIENCE↗

Photon-mediated entanglement scheme between a ZnO semiconductor defect and a trapped Yb ion

We propose an optical scheme to generate an entangled state between a trapped ion and a solid state donor qubit through which-path erasure of identical photons emitted from the two systems. The proposed scheme leverages the similar transition frequencies between In donor bound excitons in ZnO and the 2 P 1/2 to 2 S 1/2 transition in Yb+. The lifetime of the relevant ionic state is longer than that of the ZnO system by a factor of 6, leading to a mismatch in the temporal profiles of emitted photons. A detuned cavity-assisted Raman scheme weakly excites the donor with a shaped laser pulse to generate photons with a 0.99 temporal overlap to the Yb+ emission and partially shift the emission of the defect toward the Yb+ transition. Here, the remaining photon shift is accomplished via the dc Stark effect. We show that an entanglement rate of 2.1 × 10 4 s –1 and an entanglement fidelity of 94% can be attained using a weak excitation scheme with reasonable parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Solid particulate mass and number from ducted fuel injection in an optically accessible diesel engine in skip-fired operation

Ducted fuel injection (DFI) is a new combustion strategy that has been shown to significantly attenuate soot formation in diesel engines. While previous studies have used optical diagnostics and optical filter smoke number methods to show that DFI reduces in-cylinder soot formation and engine-out soot emissions, respectively, this is the first study to measure solid particle number (PN) emissions in addition to particle mass (PM). Furthermore, this study quantitatively evaluates the use of transient particle instruments for measuring particles from skip-fired operation in an optical single cylinder research engine (SCRE). Engine-out PN was measured using an engine exhaust particle sizer following a catalytic stripper, and PM was measured using a photoacoustic analyzer. The study improves on earlier preliminary emissions studies by clearly showing that DFI reduces overall PM by 76%–79% and PN for particles larger than 23 nm by 77% relative to conventional diesel combustion at a 1200-rpm, 13.3-bar gross indicated mean effective pressure operating condition. The degree of engine-out PM reduction with DFI was similar across both particulate measurement instruments used in the work. Through the use of bimodal distribution fitting, DFI was also shown to reduce the geometric mean diameter of accumulation mode particles by 26%, similar to the effects of increased injection pressure in conventional diesel combustion systems. This work clearly shows the significant solid particulate matter reductions enabled by DFI while also demonstrating that engine-out PN can be accurately measured from an optical SCRE operating in a skip-fired mode. Based on these results, it is believed that DFI has the potential to enable fuel savings when implemented in multi-cylinder engines, both by lowering the required frequency of active diesel particulate filter regeneration, and by reducing the backpressure imposed by exhaust filtration systems.

33 ADVANCED PROPULSION SYSTEMS↗

Multiphysics and Multiscale Simulation Methods for Electromagnetic Energy Assisted Fossil Fuel to Hydrogen Conversion (Final Scientific/Technical Report)

This report summarizes the technical accomplishments of the four-year research project “Multiphysics and Multiscale Simulation Methods for Electromagnetic Energy Assisted Fossil Fuel to Hydrogen Conversion” (Award No. DE-FE0032092), conducted at Howard University and the University of Houston (subawardee) from September 2021 to August 2025. The project successfully achieved all four major objectives: 1. 3D Structural Characterization – Developed 3D optical imaging and mechanical sectioning methods to characterize catalyst distribution and support morphology in nickel foam substrates. Successfully reconstructed 3D geometries and imported them into COMSOL Multiphysics for electromagnetic simulations. 2. EM Hotspot Simulation – Created all-frequency stable electromagnetic formulations and 3D nodal discontinuous Galerkin (NDG) methods for coupled electromagnetic-thermal-fluid problems in multiscale catalytic media. Demonstrated stable solutions from DC to microwave frequencies. 3. Multiphysics Coupling – Developed multiscale simulation methods coupling FEM electromagnetic solvers with thermal transport equations. Reactive molecular dynamics (ReaxFF MD) simulations were performed to investigate catalytic reaction mechanisms at the atomistic level. Demonstrated electromagnetic-thermal co-simulation capabilities for porous catalyst structures. 4. System Optimization – Designed and optimized EM-assisted catalytic systems using nickel foam and carbon foam structures, demonstrating significant temperature increases due to microwave heating. Observed and characterized plasma generation in carbon fiber catalysts. Investigated multiple reaction chamber geometries for improved microwave energy deposition. The project produced significant scientific contributions including 15+ peer-reviewed publications, trained multiple Ph.D. students and undergraduate researchers, and advanced the understanding of microwave-assisted hydrogen production from fossil fuels.

08 HYDROGEN↗

Terahertz Spectroscopy of Gas Mixtures with Dual Quantum Cascade Laser Frequency Combs

Terahertz laser frequency combs based on quantum cascade lasers provide coherent, broadband, electrically pumped, THz radiation sources for use in future spectroscopic applications. In this work, we explore the feasibility of such lasers in a dual-comb spectroscopy configuration for the detection of multiple molecular samples in the gas phase. The lasers span approximately 180 GHz of optical bandwidth, centered at 3.4 THz, with submilliwatt total optical power. One of the main advantages of dual-comb spectroscopy is its high speed, which opens up the possibility for direct observations of chemical reaction dynamics in the terahertz spectral region. As a proof-of-concept, we recorded continuously evolving spectra from gas mixtures with 1 ms temporal resolution.

42 ENGINEERING↗

An Extreme-precision Radial-velocity Pipeline: First Radial Velocities from EXPRES

The EXtreme-PREcision Spectrograph (EXPRES) is an environmentally stabilized, fiber-fed, R = 137,500, optical spectrograph. It was recently commissioned at the 4.3 m Lowell Discovery Telescope near Flagstaff, Arizona. The spectrograph was designed with a target radial-velocity (RV) precision of 30 cm s{sup −1}. In addition to instrumental innovations, the EXPRES pipeline, presented here, is the first on-sky, optical, fiber-fed spectrograph to employ many novel techniques—including an “extended flat” fiber used for wavelength-dependent quantum efficiency characterization of the CCD, a flat-relative optimal extraction algorithm, chromatic barycentric corrections, chromatic calibration offsets, and an ultra-precise laser frequency comb for wavelength calibration. We describe the reduction, calibration, and RV analysis pipeline used for EXPRES and present an example of our current sub-meter-per-second RV measurement precision, which reaches a formal, single-measurement error of 0.3 m s{sup −1} for an observation with a per-pixel signal-to-noise ratio of 250. These velocities yield an orbital solution on the known exoplanet host 51 Peg that matches literature values with a residual rms of 0.895 m s{sup −1}.

79 ASTRONOMY AND ASTROPHYSICS↗

D-Egg: a dual PMT optical module for IceCube

The D-Egg, an acronym for "Dual optical sensors in an Ellipsoid Glass for Gen2," is one of the optical modules designed for future extensions of the IceCube experiment at the South Pole. The D-Egg has an elongated-sphere shape to maximize the photon-sensitive effective area while maintaining a narrow diameter to reduce the cost and the time needed for drilling of the deployment holes in the glacial ice for the optical modules at depths up to 2700 m. The D-Egg design is utilized for the IceCube Upgrade, the next stage of the IceCube project also known as IceCube-Gen2 Phase 1, where nearly half of the optical sensors to be deployed are D-Eggs. With two 8-inch high-quantum efficiency photomultiplier tubes (PMTs) per module, D-Eggs offer an increased effective area while retaining the successful design of the IceCube digital optical module (DOM). The convolution of the wavelength-dependent effective area and the Cherenkov emission spectrum provides an effective photodetection sensitivity that is 2.8 times larger than that of IceCube DOMs. The signal of each of the two PMTs is digitized using ultra-low-power 14-bit analog-to-digital converters with a sampling frequency of 240 MSPS, enabling a flexible event triggering, as well as seamless and lossless event recording of single-photon signals to multi-photons exceeding 200 photoelectrons within 10 ns. Mass production of D-Eggs has been completed, with 277 out of the 310 D-Eggs produced to be used in the IceCube Upgrade. In this paper, we report the design of the D-Eggs, as well as the sensitivity and the single to multi-photon detection performance of mass-produced D-Eggs measured in a laboratory using the built-in data acquisition system in each D-Egg optical sensor module.

47 OTHER INSTRUMENTATION↗

Qubit control noise spectroscopy with optimal suppression of dephasing

Here, we extend quantum noise spectroscopy (QNS) of amplitude control noise to settings where dephasing noise or detuning errors make significant contributions to qubit dynamics. Previous approaches to characterize amplitude noise are limited by their vulnerability to low-frequency dephasing noise and static detuning errors, which can overwhelm the target control noise signal and introduce bias into estimates of the amplitude noise spectrum. To overcome this problem, we leverage optimal control to identify a family of amplitude control waveforms that optimally suppress low-frequency dephasing noise and detuning errors, while maintaining the spectral concentration in the amplitude filter essential for spectral estimation. The waveforms found via numerical optimization have surprisingly simple analytic forms, consisting of oscillating sine waves obeying particular amplitude and frequency constraints. In numerically simulated QNS experiments, these waveforms demonstrate superior robustness, enabling accurate estimation of the amplitude noise spectrum in regimes where existing approaches are biased by low-frequency dephasing noise and detuning errors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radio Frequency Sensor: Very High Frequency Radio Frequency Lightning Detection in Geostationary Orbit

Abstract The Radio Frequency Sensor (RFS), a new radio frequency lightning detector, was launched into geosynchronous orbit in December 2021, and first collected data in January 2022. RFS is a specialized software‐defined radio receiver that detects, records, and reports impulsive broadband radio‐frequency (RF) signatures from lightning in the very high frequency (VHF; 30–300 MHz) range. Its vantage point from a Western hemisphere geosynchronous orbit provides unique opportunities to study evolution of RF lightning signatures over the durations of thunderstorms over the Americas and Pacific Ocean. Its overlapping view with the Geostationary Lightning Mappers (GOES‐16 & 17) enables additional comparisons between the sources of optical emissions and associated VHF emissions that were not possible with previous sensors. We find that RFS preferentially detects bright VHF signals called transionospheric pulse pairs (trans‐ionospheric pulse pairs (TIPPs)). It is estimated that more than 85% of the RFS‐detected lightning events are TIPPs. This paper presents initial results from the first year and a half of on‐orbit operation.

54 ENVIRONMENTAL SCIENCES↗

Observations and Modeling of Fiber-Optics Strain on Hydraulic Fracture Height Growth in HFTS-2

Understanding fracture height growth can be of great significance to optimizing field development and improving recovery. The Hydraulic Fracturing Test Site 2 (HFTS-2) has provided a unique opportunity and an advanced dataset to allow us to observe and understand fracture geometries rigorously. Low frequency distributed acoustic sensing (LF-DAS) data from a vertical well in HFTS-2 showed three key observations: (i) excessive upward height growth (>1000 ft) and limited downward growth of the hydraulic fractures during pumping, (ii) considerable additional upward fracture height growth (~300 ft) after well shut in, and (iii) very complex LF-DAS strain rate patterns for a small fiber-to-stage offset. Advanced geomechanical modeling was performed to simulate the hydraulic fracture propagation and the resulting strain responses in the vertical direction. The modeling results demonstrated asymmetric upward and downward fracture height growths as observed in HFTS-2 with a similar upward height growth rate. Simulated waterfall plots of vertical strain rate showed distinct patterns for different fiber-to-fracture distances. The upward-growing fracture tip can be clearly identified by the interfaces between compressing and extending zones. It was also found that the complex strain rate patterns observed in HFTS-2 for small fiber-stage offsets were not caused by the mechanical layering but possibly result from the simultaneous propagation of multiple hydraulic fractures at different rates. Furthermore, the simulation results improved the understating of the HFTS-2 LF-DAS data and the simulated strain rate patterns could also serve as templates for fracture height interpretation from LF-DAS data in future.

58 GEOSCIENCES↗

Freeform three-mirror anastigmatic large-aperture telescope and receiver optics for CMB-S4

CMB-S4, the next-generation ground-based cosmic microwave background (CMB) observatory, will provide detailed maps of the CMB at millimeter wavelengths to dramatically advance our understanding of the origin and evolution of the universe. CMB-S4 will deploy large and small aperture telescopes with hundreds of thousands of detectors to observe the CMB at arcminute and degree resolutions at millimeter wavelengths. Inflationary science benefits from a deep delensing survey at arcminute resolutions capable of observing a large field of view at millimeter wavelengths. This kind of survey acts as a complement to a degree angular resolution survey. The delensing survey requires a nearly uniform distribution of cameras per frequency band across the focal plane. We present a large-throughput, large-aperture (5-meter diameter) freeform three-mirror anastigmatic telescope and an array of 85 cameras for CMB observations at arcminute resolutions, which meets the needs of the delensing survey of CMB-S4. A detailed prescription of this three-mirror telescope and cameras is provided, with a series of numerical calculations that indicate expected optical performance and mechanical tolerance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental study on the startup of the annular wick type heat pipe using fiber optical temperature measurement technique

This study used optical fiber-distributed temperature sensors to measure the internal and external temperature distributions of a water-cooled heat pipe. The sensor technology used in this study is fiber optical distributed temperature sensing, a distributed sensing technique based on the naturally occurring Rayleigh backscatter in optical fibers. This measurement technique provides maximum spatial resolution for static and semi-static applications. Using this sensor, the temperature distribution of the heat pipe's internal, external, vapor core, and the wick was measured with a spatial resolution of 0.65 mm, a sampling frequency of 40 Hz, and a temperature resolution of 0.1 °C. Through the measured temperature distribution database, the starting phenomenon, the effective length trend, and the limitation onset were observed. From the results, it is found that a high-temperature peak appears at the evaporator if a high initial power (75 W) is imposed on the heat pipe, even after the heat pipe approaches the normal operating status. The peak is not observed in a slower startup (30 W initial power then slowly increased to 75 W). It is also found that the temperature distributions and effective condenser length of the heat pipe highly depend on the cooling conditions. There are variations in the temperature according to the radial direction of the horizontal heat pipe due to gravity. In conclusion, lead and lag of the temperature evolution were observed at the onset of the operating limitations.

42 ENGINEERING↗

Simultaneous H/D/T and 3He/4He absolute concentration measurements with an optical Penning gauge on JET

The Optical Penning (or Species-Selective Penning) Gauge technique is used for the measurement of the H2/D2/T2 fuel isotopic composition and He/D2 concentration in the neutralized particle exhaust of fusion devices. An Optical Penning detection system has already been used in JET during its first deuterium-tritium campaigns (DTE1) and has been chosen by ITER. Recent improvements to the sub-divertor diagnostic suite as well as the optical instrumentation, in preparation for the next DT campaign, have improved the optical throughput of the measurement and enabled 3He/D2 detection down to 0.1 %. For the first time, the 3He/4He isotopic ratio can be measured simultaneously with the H/D/T ratio. This technique is of particular interest for ion cyclotron resonance frequency (ICRF) heating scenarios.

Vartanian, S.↗

Vibrational sum frequency generation spectroscopy reveals the inertness of chromium oxide (001) surfaces

Nanoengineered metal oxides such as Cr(III)-oxide (chromia) films have diverse potential applications in corrosion inhibition, remediation, energy generation, catalysis, data storage, and biological and environmental systems. Concerns about material degradation or oxidation to toxic chromate necessitate an understanding of chromia/aqueous interfaces, beginning with their hydroxylation and hydration behavior. Vibrational sum-frequency generation spectroscopy (vSFG) provides specific molecular-level information about water at the oxide/aqueous junction with high surface selectivity. To overcome the strong absorber problem typical of certain metal oxides in the UV–visible range during nonlinear optical studies, we employed molecular beam epitaxy to deposit transparent, epitaxial nanofilms of Cr 2 O 3 with (001) crystalline orientation on sapphire (Al 2 O 3 (001)) substrates, as confirmed by atomic force microscopy and X-ray diffraction. vSFG spectra of the air and water interfaces of the Cr 2 O 3 (001) films reveal hydroxyl features corresponding to both dissociated and molecular water on the surface. In contrast to the dangling hydroxyls found on the bare Al 2 O 3 (001) substrate, the hydroxyl groups on the deposited Cr 2 O 3 (001) nanofilm do not readily undergo isotopic H/D exchange when exposed to varying forms of D 2 O under ambient conditions. When considering the chemistries of the corresponding trivalent cations in aqueous solution, the finding is at variance with their similar acidities and proton exchange dynamics but consistent with markedly slower inner-sphere water ligand exchange of hexaquo Cr 3+ . This finding challenges the idea that proton and water exchange at the water/Cr₂O₃(001) interface are solely correlated, driven by the strength of metal-bridging oxygen bonds and surface hydroxyl distribution, without direct causation.

Boamah-Agyemang, Mavis D. [Pacific Northwest Natio↗

Hollow-cathode chemical vapor deposition of thick, low-stress diamond-like carbon films

A radio-frequency (RF), hollow-cathode plasma source with confining magnetic field is described for the chemical vapor deposition of thick ( > 10 µm), amorphous diamond-like carbon ablator films for inertial confinement fusion applications. Plasma is characterized by optical emission spectroscopy, while properties of the resultant films are measured by a combination of profilometry, Rutherford backscattering spectrometry, elastic recoil detection analysis, X-ray diffraction, Raman spectroscopy, and atomic force microscopy. The dependence of the deposition rate, film density, elemental composition, self-bias and residual stress is reported as a function of RF power. Higher density films were found when using Ar plasma, than N 2 or H 2 plasma. The coatings produced are x-ray amorphous, exhibit low compressive stress ( ~ 100 MPa), high density ( < 1.7 g/cm 3 ), hydrogen content of ~ 30 at.%, and a low average roughness of 0.75 nm. Finally, applications of these films as tunable-density ablators for inertial confinement fusion experiments are discussed.

36 MATERIALS SCIENCE↗

Rabi spectroscopy of the clock transition in thulium atoms in a one-dimensional optical lattice

The clock transition at a wavelength of 1.14 μm in thulium atoms in an optical lattice in the Lamb – Dick regime is studied. The capture of thulium atoms makes it possible to suppress completely both the transition broadening due to the first-order Doppler effect and the shift of the transition frequency caused by the recoil effect. The excitation spectra of sideband oscillation frequencies and Rabi oscillations of population between the clock transition levels upon resonance excitation are investigated. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High harmonic generation in graphene quantum dots

Abstract We study theoretically the generation of high harmonics in disk graphene quantum dots placed in linearly polarized short pulse. The quantum dots (QD) are described within an effective model of the Dirac type and the length gauge was used to describe the interaction of quantum dots with an optical pulse. The generated radiation spectra of graphene quantum dots can be controlled by varying the quantum dot size, i.e. its radius. With increasing the quantum dot radius, the intensities of low harmonics mainly decrease, while the cutoff frequency increases. The sensitivity of the cutoff frequency to the QD size increases with the intensity of the pulse.

Physics↗

Quantum Instrumentation Control Kit Defect Arbitrary Waveform Generator (QICKDAWG) v.0

SAND2024-08598O The Quantum Instrumentation Control Kit Defect Arbitrary Waveform Generator (QICKDAWG) characterizes nitrogen-vacancy centers in diamond and other defects. It does this by using a radio frequency system-on-a-chip (RFSoC) field programmable gate array (FPGA). QICKDAWG synthesizes microwave pulses from the RFSoC to change the spin state of the defects. The software also allows for laser control using the RFSoC, which optically pumps defects. Ultimately, QICKDAWG supports the implementation of RFSoC FPGAs in defect characterization. This replaces the slow, expensive, traditional hardware, thus lowering the cost and time for defect characterization. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

SciDAC↗