Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical Interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

The optical depth of the 158 micron forbidden C-12 II line - Detection of the F = 1 - 0 forbidden C-13 II hyperfine-structure component

The detection of the F = 1 - 0 hyperfine component of the 158-micron forbidden C-13 II fine-structure line in the interstellar medium is reported. A 12-point intensity map was obtained of the forbidden C-13 distribution over the inner 190-arcsec (R.A.) X 190-arcsec (decl.) regions of the Orion Nebula using an imaging Fabry-Perot interferometer. The forbidden C-12 II/C-13 II line intensity ratio varies significantly over the region mapped. It is highest (86 +/-0) in the core of the Orion H II region, and significantly lower (62 +/-7) in the outer regions of the map, reflecting higher optical depth in the forbidden C-12 II line here. It is suggested that this enhanced optical depth is the result of limb brightening of the optically thin forbidden C-13 II line at the edges of the bowl-shaped H II region blister.

Stacey, G. J.↗

Stress Tuning of Laser Crystals

The topic of stress tunable laser crystals is addressed in this study with the purpose of determining the piezo-optic coefficients of a new laser material. This data was collected using a quadruple pass birefringence technique because of its high degree of sensitivity relative to the other methods examined including fringe shift analysis using a Mach-Zender interferometer. A green He-Ne laser was passed through a light chopper and Glan-Thompson prism before entering a crystal of Erbium doped Yttrium Aluminum Garnet (Er:YAG) (used in order to validate the experimental technique). The Er:YAG crystal is mounted in a press mechanism and the laser is quadruple passed through test specimen before being returned through the prism and the orthogonally polarized portion of the beam measured with a optical sensor. At a later stage, the Er:YAG crystal was replaced with a new crystal in order to determine the piezo-optic coefficients of this uncharacterized material. The applied load was monitored with the use of a 50 lb. load cell placed in line with the press. Light transmission readings were taken using a lock-in amplifier while load cell measurements were taken with a voltmeter from a 5 volt, 0.5 amp power supply. Despite the fact that an effective crystal press damping system was developed, size limitations precluded the use of the complete system. For this reason, data points were taken only once per full turn so as to minimize the effect of non uniform load application on the collected data. Good correlation was found in the transmission data between the experimentally determined Er:YAG and the previously known peizo-optic constants of non-doped crystal with which it was compared. The variation which was found between the two could be accounted for by the aforementioned presence of Erbium in the experimental sample (for which exact empirical data was not known). The same test procedure was then carried out on a Yttrium Gallium Aluminum garnet (YGAG) for the purpose of establishing values of its unknown piezo-optic constant tensor using experimentally collected transmission data. Significant variation between the piezo-optic constants of YAG and YGAG crystals was found however, the excellent data correlation of separate experimental runs carried out on the YGAG sample demonstrates the validity of these results. The data collected during the stressing of the YGAG was of high quality, however the amount of data collected was somewhat limited by a fracture of YGAG specimen which undoubted altered the crystalline lattice structure and hence precluded any further testing.

Carty, Atherton A.↗

Design and fabrication of a coherent array of single-mode optical fibers for the nulling coronagraph

We present the development of a single-mode spatial filter array for the nulling coronagraph application. The development consists of two generations of fiber array designs and a Zygo-interferometer based lens array to fiber array alignment methodology. We discuss the use of large mode field diameter (MFD) fibers to relax fiber placement tolerance of the fiber array. The pros and cons of using the Photonic Crystal Fiber (PCF) for building the array are discussed. The future plan for implementing a 1000-channel class, single-mode spatial filter array is described.

Shao, Mike↗

High resolution Fouier transform spectrometer Serial No. 091002: Instruction manual

A description of the spectrometer and procedures for its operation, maintenance, alignments, adjustments, and control functions are presented. The interferometer spectrometer is a modified Model 296 capable of 0.5/cm resolution over the spectral region of 5 to 15 microns configured for operation with the optical head at a temperature of approximately 80 K. Details are given on the optical system and the electronic circuits. The detector used with the optical head is mercury doped germanium kept at a temperature of about 4 K by means of liquid helium. Electronic schematics, and instruction manuals for handling the liquid helium dewars, tape recorder for analog outputs, and playback console are included.

Source record↗

Science instrumentation package, LST

The projected design of an optical instrument package for the large space telescope includes: a diffraction limited camera; low- and high-dispersion spectrographs; astrometric machines; photometers; polarimeters; F/12 camera; Fourier interferometer; infrared instrumentation; and a very high dispersion spectrographs.

Levin, G.↗

Optical Interferometric Parallel Data Processor

Image data processed faster than in present electronic systems. Optical parallel-processing system effectively calculates two-dimensional Fourier transforms in time required by light to travel from plane 1 to plane 8. Coherence interferometer at plane 4 splits light into parts that form double image at plane 6 if projection screen placed there.

Breckinridge, J. B.↗

Development of Space-Based Laser Systems at Goddard Space Flight Center

- Laser & Electro-Optics Branch at GSFC - Lidar Applications & Areas of Interest - GSFC Solid State Lasers and Fiber Lasers for Space - Space-Based Topographic Mapping Lidar Results - Laser Interferometer Space Antenna (LISA) - Lasers for in-Situ Planetary Lander Instruments - New generation lidar instruments - Laser Spectroscopy - Laser Communications - General Laser Requirements - Preparing for the future - Challenges - Conclusions - Acknowledgments

Elisavet Troupaki↗

Absorption Laser Differential Interferometry for Simultaneous Colinear Flow Property and Fluctuation Measurements

An absorption laser differential interferometer (A-LDI) was constructed and tested in an effort to simultaneously and colinearly measure flow properties (pressure, temperature, concentration) and flow fluctuations (changes in optical path length). Whereas typical LDI and focused LDI (FLDI) systems use fixed wavelength lasers as the light source (often either green at approximately 532 nm or red at approximately 630 nm), a tunable 760 nm diode laser was used to probe the A-band absorption spectrum of molecular oxygen. The A-LDI system was used to measure O2 absorption and flow fluctuations in a sub-atmospheric pressure-controlled test cell, with absorption profiles from direct absorption and wavelength modulation absorption matching simulated results, while simultaneously being sensitive to high frequency fluctuations from jets of either compressed air or 100% O2 from a gas bottle. The A-LDI system was also installed at the NASA Langley Research Center Probe Calibration Tunnel to assess the freestream flow state in a Mach 3.5 flow. LDI measurements of the freestream indicated increasing amplitudes of flow fluctuations with increasing stagnation pressure at a fixed stagnation temperature, while absorption results demonstrated sensitivity to freestream pressure changes.

Joshua M. Weisberger↗

Fiber-optic silicon Fabry–Perot interferometric bolometer with improved detection limit for magnetic confinement fusion

Fiber-optic bolometers (FOBs) intended for plasma radiation measurement in magnetically confined fusion have been previously developed using a silicon pillar that functions as both a Fabry–Perot interferometer (FPI) for temperature measurement and an absorber for the radiation. We report an FOB design that can significantly improve the detection sensitivity over earlier designs by engineering the absorber of the FOB. Our design uses the fact that, compared with a silicon pillar, a gold film with the same x-ray absorption thickness will show a much higher temperature rise from a given power density of the radiation. Therefore, the responsivity of an FOB can be improved by attaching a large gold disk to the silicon FPI as the absorber. We have developed a fabrication method for FOBs of such design and obtained an FOB with a 4-µm-thick, 0.6-mm-diameter gold disk attached to a 200-µm-diameter, 100-µm-thick silicon FPI. We have characterized the noise, responsivity, response time, and noise-equivalent power density (NEPD) and compared these with the earlier design where the absorber is mainly the silicon FPI itself. The experimental result suggests that the FOB with the gold disk achieves a responsivity of ∼2.8 mK/(W/m2) and a noise-equivalent-power-density of 0.13 W/m2, which are, respectively, more than nine times larger and six times smaller compared to the FOB using a previous design. Improved NEPD and good absorption over a broad frequency range will make the FOB more attractive for applications in magnetic-confinement fusion devices.

Uddin, Nezam↗

Optical Metrology for the Filter Set for the Hubble Space Telescope (HST) Advanced Camera for Surveys (ACS)

The Hubble Space Telescope (HST) Advanced Camera for Surveys (ACS) will employ a wide variety of spectral filtration components including narrow band, medium band, wide band, and far ultraviolet (FUV) long pass filters, spatially- variable filters (ramp filters), VIS/IR polarizers, NUV polarizers, FUV prisms, and a grism. These components are spread across ACS's Wide Field, High Resolution, and Solar Blind channels which provide diffraction-limited imaging of astronomical targets using aberration-correcting optics which remove most aberrations from HST's Optical Telescope Assembly (OTA). In order for ACS to be truly advanced, these filters must push the state-of-the-art in performance in a number of key areas at the same time. Important requirements which these filters must meet include outstanding transmitted wavefront, high transmittance, uniform transmittance across each filter, spectrally structure-free bandpasses, exceptionally high out of band rejection, and a high degree of parfocality. These constitute a very stringent set of requirements indeed, especially for filters which are up to 90 mm in diameter. The development of optical metrology stations used to demonstrate that each ACS filter will meet its design specifications is discussed. Of particular note are specially-designed spectral transmissometers and interferometers.

Leviton, Douglas B.↗

Thermodynamic and cloud parameter retrieval using infrared spectral data

High-resolution infrared radiance spectra obtained from near nadir observations provide atmospheric, surface, and cloud property information. A fast radiative transfer model, including cloud effects, is used for atmospheric profile and cloud parameter retrieval. The retrieval algorithm is presented along with its application to recent field experiment data from the NPOESS Airborne Sounding Testbed - Interferometer (NAST-I). The retrieval accuracy dependence on cloud properties is discussed. It is shown that relatively accurate temperature and moisture retrievals can be achieved below optically thin clouds. For optically thick clouds, accurate temperature and moisture profiles down to cloud top level are obtained. For both optically thin and thick cloud situations, the cloud top height can be retrieved with an accuracy of approximately 1.0 km. Preliminary NAST-I retrieval results from the recent Atlantic-THORPEX Regional Campaign (ATReC) are presented and compared with coincident observations obtained from dropsondes and the nadir-pointing Cloud Physics Lidar (CPL).

Zhou, Daniel K.↗

Results from the TOM3 testbed: thermal deformation of optics at the picometer Level

We have discussed the TOM3 testbed developed to assess the thermo-opto-mechanical stability of optical assembly such as SIM's siderostat and telescope in flight-like thermal conditions. Although limited by the metrology sensor noise, test results show that optical wavefront stability of SIM's optical assembly is compatible with single micro-arcsecond astrometry.

Space Interferometer Mission (SIM)↗

SIM PlanetQuest Spectral Calibration Development Unit Beam Combiner

The beam combiner of an astronomical long-baseline interferometer combines the two beams of starlight to form white-light fringes. We describe beam combiner in the SIM PlanetQuest Spectral Calibration Development Unit (SCDU). In addition to forming white light fringes, the beam combiner provides other functions such as separating the light for guiding, fringe tracking, and science measurement. It is designed to function over the optical bandpass 450-950 nm. Coating design is critical to beam combiner as residual dispersion and mismatches affect the ability to accurately measure the position of stars of varying spectral types.

stellar interferometer↗

Stroboscopic Interferometer for Measuring Mirror Vibrations

Stroboscopic interferometry is a technique for measuring the modes of vibration of mirrors that are lightweight and, therefore, unavoidably flexible. The technique was conceived especially for modal characterization of lightweight focusing mirror segments to be deployed in outer space; however, the technique can be applied to lightweight mirrors designed for use on Earth as well as the modal investigation of other optical and mechanical structures. To determine the modal structure of vibration of a mirror, it is necessary to excite the mirror by applying a force that varies periodically with time at a controllable frequency. The excitation can utilize sinusoidal, square, triangular, or even asynchronous waveforms. Because vibrational modes occur at specific resonant frequencies, it is necessary to perform synchronous measurements and sweep the frequency to locate the significant resonant modes. For a given mode it is possible to step the phase of data acquisition in order to capture the modal behavior over a single cycle of the resonant frequency. In order to measure interferometrically the vibrational response of the mirror at a given frequency, an interferometer must be suitably aligned with the mirror and adjustably phase-locked with the excitation signal. As in conventional stroboscopic photography, the basic idea in stroboscopic interferometry is to capture an image of the shape of a moving object (in this case, the vibrating mirror) at a specified instant of time in the vibration cycle. Adjusting the phase difference over a full cycle causes the interference fringes to vary over the full range of motion for the mode at the excitation frequency. The interference-fringe pattern is recorded as a function of the phase difference, and, from the resulting data, the surface shape of the mirror for the given mode is extracted. In addition to the interferometer and the mirror to be tested, the equipment needed for stroboscopic interferometry includes an arbitrary-function generator (that is, a signal generator), an oscilloscope, a trigger filter, and an advanced charge-coupled-device (CCD) camera. The optical components are positioned to form a pupil image of the mirror under test on the CCD chip, so that the interference pattern representative of the instantaneous mirror shape is imaged on the CCD chip.

Stahl, H. Philip↗

Fiber-optic bolometers with high-temperature tolerance and reduced time constants for fusion plasma diagnostics

Fiber-optic bolometers (FOBs) designed for plasma radiation measurement in magnetically confined fusion environments have been previously developed and tested at the DIII-D tokamak. These FOBs utilize a silicon Fabry–Perot interferometer at the fiber tip for temperature measurement and a gold disk as a radiation absorber. This paper presents recent advancements in the development of FOBs with reduced cooling time constants and enhanced temperature tolerance. We also demonstrate high-temperature operation and report findings from irradiation tests. By incorporating a copper sensor holder as a thermal sink and integrating two closely packed sensor heads into a compact design, the cooling time constants were reduced to ∼100 ms in vacuum, while minimizing uncertainties caused by temperature gradients. The FOBs were subjected to heating at 400 °C for five hours, with no observed degradation in noise performance post-heating. High-temperature operation tests were conducted at ∼220 °C using a 404 nm square-wave modulated laser to simulate the plasma radiation. In addition, four FOBs constructed from copper-coated pure-silica fibers were fabricated and underwent irradiation testing, enduring a total γ-radiation dose of 15.2 MGy and a neutron fluence of 1.6 × 10 18 n/cm 2 . As a result, the FOBs maintained their physical integrity and the optical signal shows high visibility throughout the test.

42 ENGINEERING↗

Optically thin cirrus clouds - Radiative impact on the warm pool

The role of the radiative effects of thin cirrus clouds in the energy balance of the 'warm pool' region is examined with reference to data obtained by the Infrared Interferometer Spectrometer (IRIS) flown on the Nimbus 4 satellite in 1970. First, the IRIS observations and a method for deriving the thin cirrus information are briefly discussed. A simple radiative energy balance model is then developed which is applicable to the mesoscale convective systems in the 'warm pool'. The radiative energy balance model, which does not explicitly account for the transports, is used to demonstrate the net radiative heating produced by the thin cirrus clouds.

Prabhakara, C.↗

The optical depth of the 158 micrometer (C-12 II) line: Detection of the F=1 yields 0 (C-13 III) hyperfine-structure component

The first detection of the F = 1 yields 0 hyperfine component of the 158 micrometer (C-13 II) fine structure line in the interstellar medium is reported. A twelve point intensity map was obtained of the (C-13 II) distribution over the inner 190 inch (right ascension) by 190 inch (declination) regions of the Orion nebula using an imaging Fabry-Perot interferometer. The (C-12 II)/(C-13 II) line intensity ratio varied significantly over the region mapped. It is highest (86 plus or minus 9) in the core of the Orion H II region and significantly lower (62 plus or minus 7) in the outer regions of the map, reflecting higher optical depth in the (C-12 II) line here. It is suggested that this enhanced optical depth is the result of limb brightening of the optically thin (C-13 II) line at the edges of the bowl-shaped H II region blister. If the C-12/C-13 abundance ratio is 43, the (C-12 II) line in the inner regions of the Orion nebula, has a low optical depth: tau sub 12 approximately = 0.75 plus or minus 0.25. The optical depth together with the large brightness temperature of the (C-12 II) line (approximately 160 K) requires that the excitation temperature of the P-2 sub 3/2 level be approximately 310 K, in very good agreement with the previous analysis of the physical conditions of the Orion interface region based on fine structure line intensity ratios and photodissociation region models. If the C-12/C-13 abundance ratio is 67, the line optical depth is somewhat larger (tau sub 12 approximately = 1.85), and the transition excitation temperature is somewhat smaller (approximately 190 K) than that predicted by these models. The present results therefore support values approximately = 43 for the C-12/C-13 abundance ratio in the Orion nebula.

Stacey, G. J.↗

Interferometric Techniques for Gravitational Wave Detection in Space

The Laser Interferometer Space Antenna (LISA) mission will detect gravitational waves from galactic and extragalactic sources, most importantly those involving supermassive black holes. The primary goal of this project is to investigate stability and robustness issues associated with LISA interferometry. We specifically propose to study systematic errors arising from: optical misalignments, optical surface errors, thermal effects and pointing tolerances. This report covers the first fiscal year of the grant, from January 1st to December 31st 1999. We have employed an optical modeling tool to evaluate the effect of misplaced and misaligned optical components. Preliminary results seem to indicate that positional tolerances of one micron and angular tolerances of 0.6 millirad produce no significant effect on the achievable contrast of the interference pattern. This report also outlines research plans for the second fiscal year of the grant, from January 1st to December 31st 2000. Since the work under NAG5-6880 has gone more rapidly than projected, our test bed interferometer is operational, and can be used for measurements of effects that cause beam motion. Hence, we will design, build and characterize a sensor for measuring beam motion, and then install it. We are also planning a differential wavefront sensor based on a quadrant photodiode as a first generation sensor.

Stebbins, Robin T↗