Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “operational analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Advanced transportation system studies technical area 2 (TA-2): Heavy lift launch vehicle development: Program Cost estimates - volume 3

The purpose of the TA-2 contract was to provide advanced launch vehicle concept definition and analysis to assist NASA in the identification of future launch vehicle requirements. Contracted analysis activities included vehicle sizing and performance analysis, subsystem concept definition, propulsion subsystem definition (foreign and domestic), ground operations and facilities analysis, and life cycle cost estimation. The basic period of performance of the TA-2 contract was from May 1992 through May 1993. No-cost extensions were exercised on the contract from June 1993 through July 1995. This document is part of the final report for the TA-2 contract. The final report consists of three volumes: Volume 1 is the Executive Summary, Volume 2 is Technical Results, and Volume 3 is Program Cost Estimates. The document-at-hand, Volume 3, provides a work breakdown structure dictionary, user's guide for the parametric life cycle cost estimation tool, and final report developed by ECON, Inc., under subcontract to Lockheed Martin on TA-2 for the analysis of heavy lift launch vehicle concepts.

McCurry, J. B.↗

Ten Year Operating Test Results and Post-Test Analysis of a 1/10 Segment Stirling Sodium Heat Pipe, Phase III

High-temperature heat pipes are being evaluated for use in energy conversion applications such as fuel cells, gas turbine re-combustors, Stirling cycle heat sources; and with the resurgence of space nuclear power both as reactor heat removal elements and as radiator elements. Long operating life and reliable performance are critical requirements for these applications. Accordingly, long-term materials compatibility is being evaluated through the use of high-temperature life test heat pipes. Thermacore, Inc., has carried out a sodium heat pipe 10-year life test to establish long-term operating reliability. Sodium heat pipes have demonstrated favorable materials compatibility and heat transport characteristics at high operating temperatures in air over long time periods. A representative one-tenth segment Stirling Space Power Converter heat pipe with an Inconel 718 envelope and a stainless steel screen wick has operated for over 87,000 hr (10 yr) at nearly 700 C. These life test results have demonstrated the potential for high-temperature heat pipes to serve as reliable energy conversion system components for power applications that require long operating lifetime with high reliability. Detailed design specifications, operating history, and post-test analysis of the heat pipe and sodium working fluid are described.

Rosenfeld, John, H↗

NASA Low Visibility Landing and Surface Operations (LVLASO) Atlanta Demonstration: Surveillance Systems Performance Analysis

NASA conducted a series of flight experiments at Hartsfield Atlanta International Airport as part of the Low Visibility Landing and Surface Operations (LVLASO) Program. LVLASO is one of the subelements of the NASA Terminal Area Productivity (TAP) Program, which is focused on providing technology and operating procedures for achieving clear-weather airport capacity in instrument-weather conditions, while also improving safety. LVLASO is investigating various technologies to be applied to airport surface operations, including advanced flight deck displays and surveillance systems. The purpose of this report is to document the performance of the surveillance systems tested as part of the LVLASO flight experiment. There were three surveillance sensors tested: primary radar using Airport Surface Detection Equipment (ASDE-3) and the Airport Movement Area Safety System (AMASS), Multilateration using the Airport Surface Target Identification System (ATIDS), and Automatic Dependent Surveillance - Broadcast (ADS-B) operating at 1090 MHz. The performance was compared to the draft requirements of the ICAO Advanced Surface Movement Guidance and Control System (A-SMGCS). Performance parameters evaluated included coverage, position accuracy, and update rate. Each of the sensors was evaluated as a stand alone surveillance system.

Cassell, Rick↗

Data-driven analysis and prediction of wastewater treatment plant performance: Insights and forecasting for sustainable operations

Here this study presents a comprehensive performance and forecasting analysis of the As-Samra wastewater treatment plant (WWTP) in Jordan, with two main objectives. Firstly, a thorough evaluation of the plant's performance is conducted. The analysis involves independently assessing historical operational conditions, plant production, and their statistical correlations using various statistical techniques. The second objective focuses on developing a data-driven forecasting approach to predict the plant's production one month in advance, using multiple machine learning models. The results highlight the effectiveness of principal component analysis (PCA) in simplifying operational data, revealing distinct operational clusters, and identifying seasonal production patterns while showing correlations between operational conditions and overall power production. The support vector machine (SVM) forecasting model emerged as the top performer, showcasing the potential of a hybrid forecasting approach. The findings offer valuable perspectives for enhancing operational efficiency, refining production planning, and ultimately improving the environmental impact of the plant.

42 ENGINEERING↗

Astronaut activity in weightlessness and unsupported space

For the purpose of study of the performance ability of a human operator in prolonged weightless conditions was studied by the following methods: (1) psychophysiological analysis of certain operations; (2) the dynamic characteristics of a man, included in a model control system, with direct and delayed feedback; (3) evaluation of the singularities of analysis and quality of the working memory, in working with outlines of patterned and random lines; and (4) biomechanical analysis of spatial orientation and motor activity in unsupported space.

Ivanov, Y. A.↗

Electrical Energy Storage Data Submission Guidelines, Version 2

Energy storage technologies are positioned to play a substantial role in power delivery systems. They have the potential to serve as an effective new resource to maintain reliability and allow for increased penetration of renewable energy. However, because of their relative infancy, there is a lack of knowledge about how these resources truly operate over time. A data analysis can help ascertain the operational and performance characteristics of these emerging technologies. Rigorous testing and a data analysis are important for all stakeholders to ensure a safe, reliable system that performs predictably on a macro level. Standardizing testing and analysis approaches to verify the performance of energy storage devices, equipment, and systems when integrating them into the grid will improve the understanding and benefit of energy storage over time from technical and economic vantage points. Demonstrating the life-cycle value and capabilities of energy storage systems begins with the data that the provider supplies for the analysis. After a review of energy storage data received from several providers, some of these data have clearly shown to be inconsistent and incomplete, raising the question of their efficacy for a robust analysis. This report reviews and proposes general guidelines, such as sampling rates and data points, that providers must supply for a robust data analysis to take place. Consistent guidelines are the basis of a proper protocol and ensuing standards to (1) reduce the time that it takes for data to reach those who are providing the analysis; (2) allow them to better understand the energy storage installations; and (3) enable them to provide a high-quality analysis of the installations. The report is intended to serve as a starting point for what data points should be provided when monitoring. Readers are encouraged to use the guidance in the report to develop specifications for new systems, as well as enhance current efforts to ensure optimal storage performance. As battery technologies continue to advance and the industry expands, the report will be updated to remain current.

25 ENERGY STORAGE↗

CO 2 zonal injection rate allocation and plume extent evaluation through wellbore temperature analysis

Temperature analysis during a pause in injection operations, known as warmback analysis, has been used in the petroleum industry for evaluating the injection conformance and estimating the location of the flooded front in applications, such as waterflooding oil reservoirs. Here in this work, methods are introduced to extend the application of temperature warmback analysis to estimate the zonal CO 2 injection rate and zonal CO 2 plume extent during geologic CO 2 storage in a saline aquifer. First, novel analytical solutions are developed to model transient temperature in the aquifer during the injection and subsequent shut-in periods considering two-phase flow (gaseous CO 2 and aqueous brine) conditions in the aquifer. The solution involves a discretization of the aquifer into regions; the energy and mass conservation equations for the regions are solved simultaneously considering appropriate boundary conditions at the interfaces. Two solutions techniques are presented: multi-region and three-region solutions. Inverse models are developed accordingly to evaluate the injection profile and estimate the extent of the plume front in the reservoir during the injection period. The multi-region solution results in an inversion approach that requires regression analysis. However, the three-region formulation results in a simple graphical technique for inverse modeling. The analytical solutions are validated against a thermally coupled reservoir simulation tool using different synthetic cases for CO 2 injection in deep saline aquifers. The results of the developed solutions provide a good match with numerical results during forward and inverse modeling.

54 ENVIRONMENTAL SCIENCES↗

Developing energy flexibility in clusters of buildings: A critical analysis of barriers from planning to operation

This paper examines building energy flexibility at an aggregated level and addresses the main barriers and research gaps for the development of this resource across three design and development phases: market and policy, early planning and design, and operation. We review methodologies and tools and discuss barriers, challenges, and opportunities, incorporating policy, economic, technical, professional, and social perspectives. Although various legal and regulatory frameworks exist to foster the development of energy flexibility for small buildings, financing mechanisms are limited with a significant number of perceived risks undermining private investment. For the early planning and design phase, planners and designers lack appropriate tools and face interoperability challenges, which often results in insufficient consideration of demand response programs. The review of the operational phase highlighted the socio-technical challenges related to both the complexity of deployment and communication, as well as privacy and acceptability issues. Finally, the paper proposes a number of targeted research directions to address challenges and promote greater energy flexibility deployments, including capturing building demand side dynamics, improving baseline estimations and developing seamless connectivity between buildings and districts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Generator Interconnection Cost Analysis in the Midcontinent Independent System Operator (MISO) territory

Electric transmission system operators (ISOs, RTOs, or utilities) require new large generators seeking to connect to the grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. Berkeley Lab has collected interconnection cost data from interconnection studies for the Midcontinent Independent System Operator (MISO), representing nearly 50% of all projects requesting interconnection from 2010 to 2020. Project-level cost summary data are available for download on this page. We find: -Average interconnection costs have grown as the number of interconnection requests have escalated -Projects that have completed all required interconnection studies have the lowest cost compared to applicants still actively working through the interconnection process or those that have withdrawn. -Broader network upgrade costs are the primary driver of recent cost increase. -Potential interconnection costs for wind, storage, and solar are larger than for natural gas -Larger generators have greater interconnection costs in absolute terms, but economies of scale exist on a per kW basis. -Interconnection costs vary by location Berkeley Lab will publish a series of short analytical papers of generator interconnection costs to the transmission system for MISO, PJM, SPP, ISO-NE and NYISO, which you can find at https://emp.lbl.gov/interconnection_costs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Recyclable Design for Retaining High Solar Absorptivity of the Media in CSP

Efficient thermal energy storage is pivotal to lowering the levelized cost of electricity (LCOE) for Concentrating Solar Power (CSP) plants. In solid-particle systems, however, prolonged high-temperature service degrades particle solar absorptivity, eroding overall efficiency. This project demonstrates a hydrogen-assisted recovery process that reliably restores absorptivity to >90 %, offering a practical route to sustain long-term CSP performance. Bench-scale investigations mapped the reduction kinetics of optically faded particles across hydrogen concentrations, temperatures, and residence times. Coupling mass-spectrometric monitoring with machine-learning optimization minimized energy demand while maximizing absorptivity gain. The resulting process window—moderate hydrogen partial pressures, 15–30 min dwell times, and temperatures well below initial calcination levels—cuts energy consumption well below that of incumbent re-blackening methods. A prototype recovery reactor processed multiple 2 kg batches with repeatable outcomes, confirming scalability and operational robustness. Integrated techno-economic analysis indicates material and operating cost reductions exceeding 15 % relative to conventional particle replacement or chemical re-coating, translating directly into lower LCOE for next-generation CSP facilities. By uniting fundamental reaction-kinetics insight with pragmatic engineering, this work advances the solid-particle pathway, delivering a cost-effective, field-deployable solution to one of CSP’s key durability challenges and strengthening the commercial outlook for high-temperature renewable power.

14 SOLAR ENERGY↗