Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “model building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

New Horizons: Scalar and Vector Ultralight Dark Matter

The last decade has seen unprecedented effort in dark matter model building at all mass scales coupled with the design of numerous new detection strategies. Transformative advances in quantum technologies have led to a plethora of new high-precision quantum sensors and dark matter detection strategies for ultralight ($<10\,$eV) bosonic dark matter that can be described by an oscillating classical, largely coherent field. This white paper focuses on searches for wavelike scalar and vector dark matter candidates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Machine learning for natural resource assessment: An application to the blind geothermal systems of Nevada

A study is underway to apply machine learning methods to evaluate natural resource potential. In particular, we are considering the search for blind geothermal systems in Nevada. Beginning with the data and experience from the previous Nevada play fairway analysis project, we are building models in TensorFlow/Keras and gaining experience toward predicting the geothermal resource potential as a probability map. During the first year of this project we have encountered several issues particular to using geological and geophysical data sets with these tools. Through an illustrative example we develop a promising workflow for future use as more data become available and are analyzed.

15 GEOTHERMAL ENERGY↗

Experimental study on a simplified facility of HTGR reactor building response to depressurization accidental scenarios - 18516

The analysis and understanding of air ingress events is an important aspect in the design of The High Temperature Gas Cooled Reactor (HTGR) accident scenarios including Depressurized Loss of Forced Cooling (D-LOFC) events that allow for the possibility of air ingress into the Reactor Pressure Vessel (RPV) as the result of a break in the helium pressure boundary which can ultimately result in oxidation of the fuel elements and other nuclear-grade graphite components. In order to characterize the air ingress into the vented low pressure compartments (VLPC) of NGNP HTGR during hypothetical small break D-LOFC accidents experimentally, a 1/28 down scaled simplified reactor building model was developed. A non-dimensional similarity approach was employed for the scaling analysis of the experimental facility. Two experiments were conducted under similar experimental conditions, with 1.1 kg/h helium injection through the top of the reactor cavity, resulting in oxygen concentrations reaching to steady state within 4 minutes. Differences between the steady state oxygen concentrations results in the steam generator cavity of the two tests with the same experimental conditions were 0.51{+-}0.086% at the top of the steam generator cavity and 0.29{+-}0.11% at the bottom of the steam generator cavity. Difference in the pressure in the reactor between the two experiments were 0.09{+-}0.026 psig. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Investigating Electro-Nuclear Interactions in a New Dark Matter Search

Electro-nuclear (EN) interactions are interactions in which an incident electron collides with a nucleus, scattering the electron and creating byproduct particles. Such interactions are of interest to neutrino physicists, who use EN interactions to inform model building of neutrino-nucleus interactions. The Light Dark Matter Experiment (LDMX) is a small-scale, fixed-target, electron beam experiment which seeks to probe for dark matter and mediator particle production in the sub-GeV mass region. The 8GeV LDMX electron beam will serve as an opportunity to study electro-nuclear interactions in final states in the multi-GeV region. LDMX s missing energy trigger for dark matter interactions however, will not be sufficient to efficiently capture EN interactions. An additional trigger is needed. Using simulated events, that included background and EN interactions, a trigger on momentum was developed.

Croteau, Beatrice↗

Interesting Graphite Facts

Interesting facts about graphite. Graphite within HTRs and how long they will last, potential issues prediction, model building to predict expected behavior, and frequent and thorough inspection and monitoring strategy.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

LAF-Net: A Deep Residual and Cross-Attention Framework for Day-Ahead Load Forecasting: Preprint

Accurate day-ahead load forecasting is essential for reliable power system operations and market efficiency. System operators such as the Midcontinent Independent System Operator (MISO) rely on forecasts from multiple vendors, yet combining them effectively remains a persistent challenge due to vendor-specific biases. This paper presents a novel LSTM-Attention Fusion Network with Error Representation (LAF-Net) that enhances day-ahead hourly load forecasting through deep residual learning and multi-modal cross-attention. The proposed model builds a historical error memory from past vendor performance and dynamically queries it with future hour context to generate adaptive, hour-specific trust weights for each vendor. A bounded residual correction further refines forecasts by mitigating systematic and temporally localized errors. Tested on real MISO LBA data with multi-vendor forecasts, LAF-Net consistently outperforms the best vendor baseline across all 38 LBAs, achieving more than a 40% reduction in system-level mean absolute error (MAE) during peak load hours relative to the best vendor baseline.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Earthquake-induced impact of base-isolated buildings: theory, numerical modeling, and design solutions

Earthquake shaking more intense than that used to size the horizontal clearance between a base–isolated building and near–rigid perimeter moat wall will result in hard impact, producing high–frequency, high–amplitude acceleration response in the structure and supported equipment. Herein this paper provides a design solution for the damaging effects of hard impact by installing a compliant engineered element in the load path between the base–isolated building and the moat wall, resulting in soft impact and a much smaller acceleration response. The engineered element assumed herein is a commercial–off–the–shelf marine fender with mechanical properties determined by physical testing. The attachment of a flexible engineered element, with well–defined stiffness and damping, to a near–rigid moat wall, simplifies the numerical modeling of the building–moat wall system and eliminates the need to bound the lateral stiffness of the wall for impact calculations. The simple model of the engineered element can be implemented in commercial finite element codes. Theory is developed for two–sided impact of a single–degree–of–freedom oscillator. Analytical solutions are derived for the shifted first–mode frequency of the impacted oscillator and for its free–vibration response. The shifted first–mode frequency is a function of the composite lateral stiffness of the isolator–engineered element assembly and its earthquake–induced displacement. Local peaks in the spectral response of the impacted oscillator form at odd integer multiples of the shifted first–mode frequency. The analytical solutions can be used to verify, in part, the numerical model used for impact analysis.

42 ENGINEERING↗

Tests of a reduced-scale experimental model of a building solar heating-cooling system

An experimental solar heating and cooling system model has been built and operated, combining elements that are programmable (e.g., heating and cooling load of a building and collected solar energy) with experimental equipment. The experimental system model was based on the loads and components used in the Solar Building Test Facility (SBTF), which includes a 1394 sq m solar collector field at NASA Langley. These tests covered 5 continuous days under summer conditions. For the system model up to 55 percent of the simulated collected solar energy was used for the building load. This amount of solar energy supplied 35 percent of the building cooling load. Heat loss was significant. If tank heat loss were eliminated, which would make it similar to the actual SBTF, 75 percent of the collected solar energy would be used. This amount would supply approximately 50 percent of the building cooling load. A higher fraction of solar energy is possible with a more performance-optimized system.

Namkoong, D.↗

Figures and scripts from Taylor, et al's "A multi-scale calibration approach for process-oriented aggregated building energy demand models"

This dataset includes all figures that were generated in the course of writing Taylor, et al's "A multi-scale calibration approach for process-oriented aggregated building energy demand models." It includes the figures and tables from the paper, a large number of additional figures that were not included in the paper, and the underlying data and R scripts that were used to generate the figures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building energy analysis tool

A building energy analysis system includes a building component library configured to store a plurality of building components, a modeling tool configured to access the building component library and create a building model of a building under analysis using building spatial data and using selected building components of the plurality of building components stored in the building component library, a building analysis engine configured to operate the building model and generate a baseline energy model of the building under analysis and further configured to apply one or more energy conservation measures to the baseline energy model in order to generate one or more corresponding optimized energy models, and a recommendation tool configured to assess the one or more optimized energy models against the baseline energy model and generate recommendations for substitute building components or modifications.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A library of building occupant behaviour models represented in a standardised schema

During the past four decades, a significant body of literature has reported on the impacts of occupant behaviour (OB) on building technologies, operation, and energy consumption. A large number of data-driven behavioural models have been developed based on field data. These models lack standardisation and consistency, leading to difficulties in applications and comparison. To address this concern, an ontology was developed using the drivers-needs-actions-systems (DNAS) framework. Recent work has been carried out to implement the theoretical DNAS framework into an eXtensible Markup Language (XML) schema, titled ‘occupant behaviour XML’ (obXML) which is a practical implementation of OB models that can be integrated into building performance simulation (BPS) programs. This paper presents a newly developed library of OB models represented in the standardised obXML schema format. This library provides ready-to-use examples for BPS users to employ more accurate occupant representation in their energy models. The library, which contains an initial effort of 52 OB models, was made publicly available for the BPS community. As part of the library development process, limitations of the obXML schema were identified and addressed, and future improvements were proposed. Authors hope that by compiling this library building, energy modellers from all over the world can enhance their BPS models by integrating more accurate and robust OB patterns.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Circumventing the eta problem in building an inflationary model in string theory

The eta problem is one of the most significant obstacles to building a successful inflationary model in string theory. Planck mass suppressed corrections to the inflaton potential generally lead to inflaton masses of order the Hubble scale and generate contributions of order unity to the {eta} slow-roll parameter rendering prolonged slow-roll inflation impossible. We demonstrate the severity of this problem in the context of brane antibrane inflation in a warped throat of a Calabi-Yau flux compactification with all phenomenologically dangerous moduli stabilized. Using numerical solutions we show that the eta problem can be avoided in scenarios where the inflaton is nonminimally coupled to gravity and has Dirac-Born-Infeld kinetic term. We show that the resulting cosmic microwave background observables such as measures of non-Gaussianites can, in principle, serve as a probe of scalar-gravity couplings.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development and application of a statistical methodology to evaluate the predictive accuracy of building energy baseline models

This paper documents the development and application of a general statistical methodology to assess the accuracy of baseline energy models, focusing on its application to Measurement and Verification (M&V) of whole-­building energy savings. The methodology complements the principles addressed in resources such as ASHRAE Guideline 14 and the International Performance Measurement and Verification Protocol. It requires fitting a baseline model to data from a ``training period’’ and using the model to predict total electricity consumption during a subsequent ``prediction period.’’ We illustrate the methodology by evaluating five baseline models using data from 29 buildings. The training period and prediction period were varied, and model predictions of daily, weekly, and monthly energy consumption were compared to meter data to determine model accuracy. Several metrics were used to characterize the accuracy of the predictions, and in some cases the best-­performing model as judged by one metric was not the best performer when judged by another metric.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A practical method to obtain kinetic data from $\mathrm{TGA}$ (thermogravimetric analysis) experiments to build an air injection model for enhanced oil recovery

To build an air injection model for enhanced oil recovery, it is necessary to obtain the kinetic data from thermal experiments. For TGA (thermogravimetry analysis) experiments, fitting the weight loss data using different forms of the Arrhenius Equation is practiced to obtain a single set of kinetic data which are used for the whole temperature range. The problem is that the kinetic data changes with the test temperature, oil composition, etc. Therefore, the obtained kinetic data do not represent the actual physics. Here this paper presents a detailed practical method to obtain kinetic data from TGA experiments to build an air injection model. The air injection model contains two parts. One part is to define fluid pseudo-components and their physical properties. The other part is to define oxidation reaction and the corresponding kinetic data. In order to validate the air injection model, both air purging TGA experiments and nitrogen purging TGA experiments are conducted. The fluid model (pseudo-components and their properties) is validated by matching model results with the nitrogen purging TGA experiments. Then, the kinetic data are obtained by matching the model results with the air purging TGA experiments. To verify the above approach to build an air injection model, TGA experiments using a pure hydrocarbon C20 and a Wolfcamp crude oil were conducted. The pure hydrocarbon C20 is used to verify the approach. Then seven oxidation reactions of seven pseudo components are utilized to define the air injection model for the Wolfcamp crude oil. The selection of the pseudo components was validated with the nitrogen purging TGA experiments and the oxidation reactions were validated with the air purging TGA experiments. The result shows that the combination of isomerization reactions and oxygen addition reactions can perfectly simulate a light oil air injection process in the low temperature region. This paper shows that an air injection model can be built using the kinetic data by analyzing TGA experiments.

42 ENGINEERING↗

Institutional Transformation (IX) 2.5 Building Module Help Manual

The Institutional Transformation (IX) building module is a software tool developed at Sandia National Laboratories to evaluate energy conservation measures (ECMs) on hundreds of DOE-2 building energy models simultaneously. In IX, ECMs can be designed through parameterizing DOE-2 building models and doing further processing via visual basic for applications subroutines. IX provides the functionality to handle multiple building models for different years, which enables incrementally changing a site of hundreds of buildings over time. It also enables evaluation of the effects of changing climate, comparisons between data and modeling results, and energy use of centralized utility buildings (CUBs). IX consists of a Microsoft Excel® user interface, Microsoft Access® database, and Microsoft Excel® CUB build utility whose functionalities are described in detail in this report. In addition to descriptions of the user interfaces, descriptions of every ECM already designed in IX is included.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrating physics-based models with sensor data: An inverse modeling approach

Physics-based building energy models (e.g., EnergyPlus) rely on some unknown input parameters (e.g., zone air infiltration) that are hard to measure, leading to uncertainty in simulation results especially for existing buildings with varying operating conditions. With the increasing deployment of smart thermostats, zone air temperature data are readily available, posing a new opportunity for building energy modeling if such data can be harnessed. This study presents a novel inverse modeling approach which inverses the zone air heat balance equation and uses the measured zone air temperature to analytically calculate the zone air infiltration rate and zone internal thermal mass (e.g., furniture, interior partitions), which are two important model parameters with great variability and difficult to measure. This paper introduces the technical concept and algorithms of the inverse models, their implementation in EnergyPlus, and verification using EnergyPlus simulated building performance data. The inverse modeling approach provides new opportunities for integrating data from massive IoT sensors and devices to enhance the accuracy of simulation results which are used to inform decision making on energy retrofits and efficiency improvements of existing buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ARRA: Reconfiguring Power Systems to Minimize Cascading Failures - Models and Algorithms

Building on models of electrical power systems, and on powerful mathematical techniques including optimization, model predictive control, and simluation, this project investigated important issues related to the stable operation of power grids. A topic of particular focus was cascading failures of the power grid: simulation, quantification, mitigation, and control. We also analyzed the vulnerability of networks to component failures, and the design of networks that are responsive to and robust to such failures. Numerous other related topics were investigated, including energy hubs and cascading stall of induction machines

24 POWER TRANSMISSION AND DISTRIBUTION↗