Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microporous”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Strategies for Reducing the PGM Loading in High Power AEMFC Anodes

Anion Exchange Membrane Fuel Cells (AEMFCs) have experienced a significant rise in attention in recent years, largely motivated by the potential to overcome the costs that have plateaued for proton exchange membrane fuel cells. However, despite significant advances in power generation, membrane conductivity, membrane stability, and catalyst activity, the vast majority of high performing AEMFCs are fabricated with a high PGM loading (0.4-0.8 mg cm -2 ). This work demonstrates an electrode fabrication method that reduces the anode catalyst loading by 85 % while still achieving performance ca. 1 W cm -2 - accomplished by designing a multi-layered electrode comprised of an optimized ionomer:carbon:PGM ratio catalyst layer coupled with a hydrophobic microporous layer. If paired with a high-performing PGM-free cathode, this new anode can meet existing DOE PGM loading and performance targets.

30 DIRECT ENERGY CONVERSION↗

Corrosion protection mechanism of polyaniline blended organic coating on steel

Epoxy-coal tar coatings are widely used to protect steel structures exposed to marine atmosphere due to their good barrier property. However, the presence of micropores and microcracks formed during the coating formation leads to failure of the coating due to permeation of corrosive ions. In recent years, it has been established that the coatings containing polyaniline (PANI) is able to protect pinholes and defects due to its passivating ability. Hence, a study has been made on the effect of polyaniline content (1 and 3%) in epoxy-coal tar coating on the corrosion protection of steel in 3% NaCl solution by electrochemical impedance spectroscopy (EIS) studies. Both phosphate- and chloride-doped polyanilines were prepared by a chemical oxidative polymerization method. From EIS studies, it has been found that the resistance value of the coatings containing 1 and 3% phosphate-doped polyaniline and 3% chloride-doped polyaniline pigmented coatings are similar to 10{sup 9} {Omega} cm{sup 2} even after 90 days exposure to NaCl solution, which are two orders high in comparison to that of conventional coal tar epoxy coatings. Besides, the conducting state of polyaniline has been found to be decreased after exposure to NaCl solution due to redox property of PANI. X-ray photoelectron spectroscopy studies have shown that polyaniline forms a complex layer with iron beneath the coating along with iron oxide.

01 COAL, LIGNITE, AND PEAT↗

Carbon Support Microstructure Impact on High Current Density Transport Resistances in PEMFC Cathode

Cell voltages at high current densities (HCD) of an operating proton-exchange membrane fuel cell (PEMFC) cathode suffer from losses due to the local-O 2 and bulk-H + transport resistances in the catalyst layer. Particularly, the microstructure of high surface area carbon (HSC) support upon which both the platinum catalyst and ionomer are dispersed play a pivotal role in controlling the reactant transport to the active site in the catalyst layer. In this study, we perform a systematic analysis of the underlying microstructure of platinum-cobalt catalyst dispersed on various HSC supports in terms of their surface area and pore-size distribution. The carbon microstructure was found to strongly influence the PtCo nanoparticle dispersion, catalyst layer ionomer distribution and transport losses governing the performance at HCD. Catalyst layer electrochemical diagnostics carried out to quantify local-O 2 transport resistance and bulk-H + transport resistance in the cathode were found to be directly correlated to the micropore (<2 nm) and macropore (>8 nm) surface areas of the carbon support, respectively. Finally, a 1D-performance model has been developed to assimilate our understanding of the catalyst layer microstructure and transport resistances at HCD.

25 ENERGY STORAGE↗

Oxygen Reduction Reaction Activity of Nanocolumnar Platinum Thin Films by High Pressure Sputtering

Nanocolumnar platinum thin films (Pt-TFs) were produced by high pressure sputtering (HIPS) and investigated as oxygen reduction reaction electrocatalysts for polymer electrolyte membrane fuel cells. Conventional high-density Pt-TF prepared by low pressure sputtering was also studied for comparison. Pt-TFs were deposited on a microporous layer (MPL)-like surface composed of carbon particles to mimic catalyst-coated gas diffusion electrodes. Electron microscopy imaging revealed that HIPS Pt-TFs developed a cauliflower-like columnar microstructure, which originated from a shadowing effect during HIPS. This shadowing effect is enhanced on the rough surface of the MPL-like carbon that leads to the nano-cauliflower formation. With this approach, we also aimed to relate the catalyst performance obtained by benchtop tests directly to membrane electrode assembly test results. The electrochemically active surface area of Pt-TFs increased from 10 to 19 m 2 /g with increasing sputter pressure. Specific activity of conventional high-density and nanocolumnar films were similar at ~600 μA/cm 2 , which is likely due to their similar crystal grain sizes, >5 nm. On the other hand, mass-specific (MA) activity values increased from ~0.06 A/mgPt for conventional Pt-TF to ~0.13 A/mgPt for HIPS Pt-TFs, which is consistent with the columnar microstructure of HIPS films providing a better catalyst utilization compared to conventional Pt-TF.

08 HYDROGEN↗

Microstructural Evolution and ORR Activity of Nanocolumnar Platinum Thin Films with Different Mass Loadings Grown by High Pressure Sputtering

Nanocolumnar platinum thin films (Pt-TFs) with different Pt mass loadings were grown by high pressure sputtering (HIPS) and investigated as oxygen reduction reaction (ORR) electrocatalysts for polymer electrolyte membrane fuel cell applications. Mass loading was controlled by changing the sputter deposition time. A cauliflower-like columnar microstructure was achieved by depositing the Pt-TFs onto a microporous layer (MPL)-like surface composed of carbon particles in order to mimic catalyst-coated gas diffusion electrodes. Microstructural evolution of HIPS Pt-TFs and their ORR activity were investigated. Electrochemical characterization of the nanocolumnar Pt-TFs was performed by cyclic voltammetry and rotating disk electrode measurements on Pt-TF/MPL-like-layer/glassy-carbon samples in an aqueous perchloric acid electrolyte. The electrochemically active surface area increased from 18 to 39 m 2 g –1 as the Pt mass loading was decreased. Specific activity of the films was similar (~600 μA cm –2 ) for all Pt mass loadings, due to the similar nanoparticle sizes of ~5 nm as observed by transmission electron microscopy and X-ray diffraction. Furthermore, mass activity of the films increased from 0.11 to 0.26 A mg –1 as the Pt mass loading was decreased, which is an indication of the effective Pt utilization and better access through the catalyst layer at lower Pt mass loadings.

08 HYDROGEN↗

Editors’ Choice—Diffusion Media for Cation Contaminant Transport Suppression into Fuel Cell Electrodes

Polymer electrolyte membrane fuel cells provide an alternative option to fossil fuel-based energy conversion devices. However, the corrosion of fuel cell components, specifically the bipolar plates, introduces contaminants (e.g., Fe, Ni) into the membrane electrode assembly (MEA). These contaminants accelerate the ionomer degradation by acting as a Fenton’s reagent, decreasing the fuel cell’s durability. This study presents the mechanism and the diffusion media properties affecting the transport of cation contaminants into the MEA. Cation contaminant transport was studied after altering the gas diffusion layers (GDLs) wettability, emulating the GDL properties after prolonged operation, by ex situ hydrogen peroxide treatment or in situ electrochemical potential cycling. A GDL with crack-free microporous layer (MPL) showed a lower cation transport rate to the catalyst layer than MPL with cracks after both ex situ and in situ treatment. A novel GDL was developed from modification of the conventional GDL via the addition of a hydrophobic layer to the GDL substrate, which suppressed the contaminant cation transport significantly. This novel GDL also showed improved fuel cell performance.

25 ENERGY STORAGE↗

Mechanistic Insights of Pore Contributions in Carbon Supercapacitors by Modified Step Potential Electrochemical Spectroscopy

Porous carbons are widely used as electrode materials for electrical double layer (EDL)-type supercapacitors. Differentiation of capacitance contributions from micropores and mesopores is important to understand porous carbon capacitive behavior. However, this remains challenging to accomplish. Here, we present an improved step potential electrochemical spectroscopy method to investigate the contributions to capacitance from hierarchical pores and redox processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Impact of Micro Porous Layer on Liquid Water Evolution inside PEMFC using Lattice Boltzmann Method

Proton exchange membrane fuel cells (PEMFCs) require a gas diffusion layer to aid in fuel transport to the catalyst sites. A microporous layer (MPL) is often added to the GDL to improve liquid saturation inside gas diffusion media. In this work, the lattice Boltzmann method was applied to four GDL samples with the addition of an MPL. Three injection orientations were used to study liquid evolution through the samples. Each orientation used four different injection pressures, ranging from 5,000 Pa to 8,000 Pa. Saturation data for GDL samples with and without an MPL were compared. Results showed that when adding an MPL, liquid tends to distribute laterally under the MPL until pressure is reached to allow liquid to travel through the cracks of the MPL surface and into the GDL geometry. A more uniform saturation distribution across the sample is seen when comparing both types of GDLs. The outcomes of this work will help research that requires knowledge of the internal liquid transport through gas diffusion media for PEMFC application.

Sepe, M.↗

Nanocolumnar Pt:Ni Alloy Thin Films by High Pressure Sputtering for Oxygen Reduction Reaction

Self-supported nanocolumnar Pt:Ni thin films (TFs) with varying Pt:Ni atomic ratios and Pt mass loadings were produced on a microporous layer (MPL)-like surface composed of carbon particles by high pressure sputtering and examined as oxygen reduction reaction (ORR) electrocatalysts for polymer electrolyte membrane fuel cells. Cauliflower-like microstructures were observed from scanning electron microscopy imaging. Various Pt:Ni atomic ratios were obtained by simply changing the relative deposition power between Pt and Ni source and investigated by X-ray diffraction and quartz crystal microbalance analysis. Additionally, electrochemical characterization of the Pt:Ni-TF/MPL-like-layer/glassy-carbon samples was conducted through benchtop cyclic voltammetry and rotating disk electrode measurements. The electrochemically active surface area (ECSA) was found to be between 22–42 m 2 g -1 for different Pt:Ni atomic ratios. Lower Pt mass loadings exhibited a higher ECSA and the catalytic activity of all Pt:Ni ratios increased with the increase in Pt mass loading. The ORR activity of the Pt:Ni-TFs increased in the order of 3:1 < 1:1 < 1:3 with exhibiting a specific activity of 1781 μA cm -2 and mass activity of 0.66 A mg -1 for the Ni-rich film with 1:3 ratio. The catalytic performance of Pt:Ni-TFs were higher than traditional high surface area carbon supported Pt nanoparticles, elemental Pt nanorods, and Pt-Ni nanorods.

08 HYDROGEN↗

Study of Cathode Gas Diffusion Architecture for Improved Oxygen Transport in Hydroxide Exchange Membrane Fuel Cells

The high pH environment in hydroxide exchange membrane fuel cells (HEMFCs) has the potential to reach lower costs than the current proton exchange membrane fuel cells (PEMFCs), the incumbent technology. A significant difference between HEMFCs and PEMFCs is the location of water production within the cell. In PEMFCs, the water is produced on the cathode, limiting oxygen transport. In HEMFCs, the water is produced on the anode where the fuel is pure hydrogen. This allows the cathode to be optimized for oxygen transport without the presence of excess liquid water. Limiting current analysis, a technique previously used in PEMFCs, is adopted in HEMFCs to evaluate the oxygen mass transport resistances for different sections of the cathode. Through elimination of the microporous layer (MPL), gas diffusion layer (GDL), and traditional flow field and using porous nickel foam for gas distribution, the transport resistance at an operating condition of 150 kPa(g) and with the cell temperature at 80 °C was decreased from 112 s m −1 to 48 s m −1 , effectively halved. The optimal configuration for performance was found with Ni foam and a GDL, eliminating the MPL and traditional flow field, which vastly improved oxygen transport while maintaining adequate electrical contact with the cathode catalyst layer.

25 ENERGY STORAGE↗

Membrane Considerations for the All-Iron Hybrid Flow Battery

The all-iron flow battery is currently being developed for grid scale energy storage. As with all flow batteries, the membrane in these systems must meet stringent demands for ionic conductivity while limiting unwanted reactant (Fe 3+ ) crossover. In addition, for the all-iron chemistry proton transport across the membrane is highly desirable to maintain the pH levels in the negative and positive electrolytes. Two membranes are considered, Nafion and an in-house developed composite based on Daramic (a commercial microporous separator) and poly(vinyl alcohol). Their performance is compared for various metrics specific to the all-iron flow battery chemistry.

25 ENERGY STORAGE↗

Durability Optimization of CO 2 Electrolyzers for Syngas Evolution

Recently, there has been an increased interest in mitigating anthropogenic CO 2 emissions through the electrochemical conversion of CO 2 into fuels and fuel feedstocks, including hydrogen gas (H 2 ), carbon monoxide (CO), and mixtures of the two to yield syngas. Commercial applications of these systems require high catalytic selectivity for the desired products, while exhibiting operational lifetimes exceeding thousands of hours. Advancements in this field have produced systems that display high selectivity of the desired products at faradaic efficiencies exceeding 95%. Despite the advancements made in CO 2 electrolysis, system durability remains a standing challenge in the field. CO 2 electrolyzer lifetimes are often limited by carbonate fouling, catalyst degradation, detrimental flooding of electrode microporous layers and anion exchange membrane (AEM) failures. In this report, a 5 cm 2 membrane electrode assembly (MEA) device is used to investigate potential failure modes and to optimize AEM CO 2 electrolyzer operation. Key findings of this study include the importance of CO 2 flow rate, use of a thin PiperION PTFE-reinforced membrane, optimizing compression to enhance contact under 40 in-lb compression, and the effect of more compressible, commercial iridium oxide anodes on system durability.

Abouremeleh, Mohammed H. [Lawrence Berkeley Nation↗

Design and Demonstration of Three-Electrode Pouch Cells for Lithium-Ion Batteries

Simple three-electrode pouch cells which can be used in distinguishing the voltage and resistance in individual electrodes of lithium ion batteries have been designed. Baseline (1 mm-staggered alignment, cathode away from a reference electrode) and aligned electrodes to a reference electrode located outside of the anode and cathode were studied to see alignment effects on resistance analysis. Cells composed of A12 graphite anodes, LiNi 0.5 Mn 0.3 Co 0.2 O 2 (NMC 532 or NCM 523) cathodes, lithium foil references, microporous tri-layer membranes, and electrolytes, were cycled with cathode cutoff voltages between 3.0 V and 4.3 V for formation cycles or 4.6 V for C-rate performance testing. By applying a hybrid pulse power characterization (HPPC) technique to the cells, resistances of the baseline cells contributed by the anode and cathode were found to be different from those of the aligned cells, although overall resistances were close to ones from aligned cells. As a result, resistances obtained via electrochemical impedance spectroscopy (EIS) and 2D simulation were also compared with those obtained from HPPC.

25 ENERGY STORAGE↗

Fundamental Understanding of Water Movement in Gas Diffusion Layer under Different Arrangements Using Combination of Direct Modeling and Experimental Visualization

In this paper, direct-modeling-based Lattice Boltzmann Method (LBM) combined with in-situ flow visualization, is used to explore fundamentally the transport of liquid-water inside the gas-diffusion layers (GDLs) used in polymer electrolyte fuel cells. Studies of the water evolution, water saturation, and breakthrough pressure inside a GDL with single and multiple injection points under land and channel geometries are explored. The model and experiment demonstrate good agreement between geometries of GDLs provided in this study which were obtained by a three-dimensional (3-D), reconstructed micro-structure from micro X-ray computed tomography (CT). The overall predictions of water evolution within the GDL agree well with the data visualized from the X-ray CT experiment for all cases studied. It also reveals that the liquid-water saturation profiles inside the GDL and breakthrough pressure are different when the location of the water injection point is altered, thereby providing analysis as to the impact of microporous layers or catalyst-layer functioning. Moreover, the uncompressed GDL undergoes a significantly different mechanism of water transport than that of the compressed GDL. Furthermore, the predictions show that the wettability variation is one of the key factors of the saturation characteristics.

42 ENGINEERING↗

On Leakage Current Measured at High Cell Voltages in Lithium-Ion Batteries

In this study, parasitic side reactions in lithium-ion batteries were examined experimentally using a potentiostatic hold at high cell voltage. The experimental leakage current measured during the potentiostatic hold was compared to the Tafel expression and showed poor agreement with the expected transfer coefficient values, indicating that a more complicated expression could be needed to accurately capture the physics of this side reaction. Here we show that cross-talk between the electrodes is the primary contribution to the observed leakage current after the relaxation of concentration gradients has ceased. This cross-talk was confirmed with experiments using a lithium-ion conducting glass ceramic (LICGC) separator, which has high conductance only for lithium cations. The cells with LICGC separators showed significantly less leakage current during the potentiostatic hold test compared to cells with standard microporous separators where cross-talk is present. In addition, direct-current pulse power tests show an impedance rise for cells held at high potentials and for cells held at high temperatures, which could be attributed to film formation from the parasitic side reaction. Based on the experimental findings, a phenomenological mechanism is proposed for the parasitic side reaction which accounts for cross-talk and mass transport of the decomposition products across the separator.

25 ENERGY STORAGE↗

In situ and ex situ characterization of carbon corrosion in PEMFCs

Carbon corrosion is an important degradation mechanism that impairs PEMFC performance through destruction of catalyst connectivity, collapse of pore structure, and loss of hydrophobic character. In this study, carbon corrosion was quantified in situ by measurement of carbon dioxide in fuel cell exhaust gases through non-dispersive infrared spectroscopy (NDIR). Performance degradation was also studied by a DOE protocol for catalyst support accelerated stress testing. Finally, changes in gas diffusion layer and microporous layer carbon surfaces were observed through an ex situ aging procedure.

30 DIRECT ENERGY CONVERSION↗

Kenaf Bast Fibers—Part I: Hermetical Alkali Digestion

The objective of this study was to develop a hermetical alkali digestion process to obtain single cellulosic fibers from kenaf bast. Kenaf bast were hermetically digested into single fiber using a 5% sodium hydroxide solution for one hour at four different temperatures (80 ° C, 110 ° C, 130 ° C, and 160 ° C). The hermetical digestion process used in this study produced fibers with high cellulose content (84.2–92.3%) due to the removal of lignin and hemicelluloses. The surface hardness and elastic modulus of the fibers digested at 130 ° C and 160 ° C were improved significantly compared with those digested at 80 ° C. The tensile modulus and tensile strength of the individual fibers reduced as the digestion temperature increased from 110 ° C to 160 ° C. Micropores were generated in fiber cell wall when the fibers were digested at 130 ° C and 160 ° C. The studies on the composites that were made from polypropylene reinforced with the digested fibers indicated that the compatibility between the digested fibers and polypropylene matrix was poor.

Shi, Jinshu↗

Controlled Release from Core-Shell Nanoporous Silica Particles for Corrosion Inhibition of Aluminum Alloys

Cerium (Ce) corrosion inhibitors were encapsulated into hexagonally ordered nanoporous silica particles via single-step aerosol-assisted self-assembly. The core/shell structured particles are effective for corrosion inhibition of aluminum alloy AA2024-T3. Numerical simulation proved that the core-shell nanostructure delays the release process. The effective diffusion coefficient elucidated from release data for monodisperse particles in water was 1.0 × 10 − 14 m 2 s for Ce 3+ compared to 2.5 × 10 − 13 m 2 s for NaCl. The pore size, pore surface chemistry, and the inhibitor solubility are crucial factors for the application. Microporous hydrophobic particles encapsulating a less soluble corrosion inhibitor are desirable for long-term corrosion inhibition.

Jiang, Xingmao↗