Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measured data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

USA Space Debris Environment, Operations, and Research Updates

Space Missions in 2017 Earth Satellite Population Collision Avoidance Maneuvers Post mission Disposal of U.S.A. Spacecraft Space Situational Awareness (SSA) and the Space Debris Sensor (SDS) A total of 86 space launches placed more than 400 spacecraft into Earth orbits during 2017, following the trend of increase over the past decade NASA has established conjunction assessment processes for its human spaceflight and uncrewed spacecraft to avoid accidental collisions with objects tracked by the U.S. Space Surveillance Network - NASA also assists other U.S. government spacecraft owners with conjunction assessments and subsequent maneuvers The ISS has conducted 25 debris collision avoidance maneuvers since 1999 - None in 2016-2017, but an ISS visiting vehicle had one collision avoidance maneuver in 2017 During 2017 NASA executed or assisted in the execution of 21 collision avoidance maneuvers by uncrewed spacecraft - Four maneuvers were conducted to avoid debris from Fengyun-1C - Two maneuvers were conducted to avoid debris from the collision of Cosmos 2251 and Iridium 33 - One maneuver was conducted to avoid the ISS NASA has established conjunction assessment processes for its human spaceflight and uncrewed spacecraft to avoid accidental collisions with objects tracked by the U.S. Space Surveillance Network - NASA also assists other U.S. government spacecraft owners with conjunction assessments and subsequent maneuvers The ISS has conducted 25 debris collision avoidance maneuvers since 1999 - None in 2016-2017, but an ISS visiting vehicle had one collision avoidance maneuver in 2017 During 2017 NASA executed or assisted in the execution of 21 collision avoidance maneuvers by uncrewed spacecraft - Four maneuvers were conducted to avoid debris from Fengyun-1C - Two maneuvers were conducted to avoid debris from the collision of Cosmos 2251 and Iridium 33 The 2014-15 NASA Engineering and Safety Center (NESC) study on the micrometeoroid and orbital debris (MMOD) assessment for the Joint Polar Satellite System (JPSS) provided the following findings - Millimeter-sized orbital debris pose the highest penetration risk to most operational spacecraft in LEO - The most effective means to collect direct measurement data on millimetersized debris above 600 km altitude is to conduct in situ measurements - There is currently no in situ data on such small debris above 600 km altitude Since the orbital debris population follows a power-law size distribution, there are many more millimeter-sized debris than the large tracked objects - Current conjunction assessments and collision avoidance maneuvers against the tracked objects (which are typically 10 cm and larger) only address a small fraction (<1%) of the mission-ending risk from orbital debris To address the millimeter-sized debris data gap above 600 km, NASA has recently developed an innovative in situ measurement instrument - the Space Debris Sensor (SDS) - One maneuver was conducted to avoid the ISS

Liou, J.-C.↗

International Space Station Increment-6/8 Microgravity Environment Summary Report November 2002 to April 2004

This summary report presents the analysis results of some of the processed acceleration data measured aboard the International Space Station during the period of November 2002 to April 2004. Two accelerometer systems were used to measure the acceleration levels for the activities that took place during Increment-6/8. However, not all of the activities during that period were analyzed in order to keep the size of the report manageable. The National Aeronautics and Space Administration sponsors the Microgravity Acceleration Measurement System and the Space Acceleration Measurement System to support microgravity science experiments that require microgravity acceleration measurements. On April 19, 2001, both the Microgravity Acceleration Measurement System and the Space Acceleration Measurement System units were launched on STS-100 from the Kennedy Space Center for installation on the International Space Station. The Microgravity Acceleration Measurement System unit was flown to the station in support of science experiments requiring quasi-steady acceleration measurements, while the Space Acceleration Measurement System unit was flown to support experiments requiring vibratory acceleration measurement. Both acceleration systems are also used in support of the vehicle microgravity requirements verification as well as in support of the International Space Station support cadre. The International Space Station Increment-6/8 reduced gravity environment analysis presented in this report uses acceleration data collected by both sets of accelerometer systems: 1. The Microgravity Acceleration Measurement System, which consists of two sensors: the Orbital Acceleration Research Experiment Sensor Subsystem, a low frequency range sensor (up to 1 Hz), is used to characterize the quasi-steady environment for payloads and vehicle, and the High Resolution Accelerometer Package, which is used to characterize the vibratory environment up to 100 Hz. 2. The Space Acceleration Measurement System measures vibratory acceleration data in the range of 0.01 to 400 Hz. This summary report presents analysis of some selected quasi-steady and vibratory activities measured by these accelerometers during Increment-6/8 from November 2002 to April 2004.

Jules, Kenol↗

Interpretation of TEPC Measurements in Space Flights for Radiation Monitoring

For the proper interpretation of radiation data measured in space, the results of integrated radiation transport models were compared with the tissue equivalent proportional counter (TEPC) measurements. TEPC is a simple, time-dependent approach to radiation monitoring for astronauts on board the International Space Station. Another and a newer approach to microdosimetry is the use of silicon-on-insulator (SOI) technology launched on the MidSTAR-1 mission in low Earth orbit (LEO). In the radiation protection practice, the average quality factor of a radiation field is defined as a function of linear energy transfer (LET), Qave(LET). However, TEPC measures the average quality factor as a function of the lineal energy y, Qave(y), defined as the average energy deposition in a volume divided by the average chord length of the volume. The deviation of y from LET is caused by energy straggling, delta-ray escape or entry, and nuclear fragments produced in the detector volume. The response distribution functions of the wall-less and walled TEPCs were calculated from Monte-Carlo track simulations. Using an integrated space radiation model (which includes the transport codes HZETRN and BRYNTRN, and the quantum nuclear interaction model QMSFRG) and the resultant response distribution functions from Monte-Carlo track simulations, we compared model calculations with the walled-TEPC measurements from NASA missions in LEO and made predictions for the lunar and the Mars missions. Good agreement was found for Qave(y) between the model and measured spectra from past NASA missions. The Qave(y) values for the trapped or the solar protons ranged from 1.9-2.5. This over-estimates the Qave(LET) values which ranged from 1.4-1.6. Both quantities increase with shield thickness due to nuclear fragmentation. The Qave(LET) for the complete GCR spectra was found to be 3.5-4.5, while flight TEPCs measured 2.9-3.4 for Qave(y). The GCR values are decreasing with the shield thickness. Our analysis of the measurements of TEPCs can be used for a proper interpretation of observed data of monitoring the space radiation environment.

Kim, Myung-Hee Y.↗

Development of a High Frequency Class-A Amplifier for High Temperature Wireless Microsystems based on a Silicon Carbide Static Induction Transistor

Next generation gas turbine engine health monitoring for high performance jet engine-powered aircraft will incorporate integrated microelectronic sensors specifically designed to enhance aircraft functionality, engine efficiency, and safety. Temperature, air flow and pressure associated with the gas path as well as emissions from the engine correlate to the state of the combustor and other engine health conditions. Monitoring these parameters accurately requires positioning electronic sensors in the hot zone of the gas turbine engine, which exposes them to temperatures in excess of 400ºC. At these temperatures, signal amplification is needed at the transducer level to distinguish the desired measured signal from the significant electronic noise generated by the harsh environment. In this presentation, we report on the simulation, development, fabrication, and testing on a high temperature Class-A amplifier which utilizes a 4H-SiC Static Induction Transistor (SIT) as the active device and input/output matching and DC bias networks comprised of thin-film spiral inductors, metal-insulator-metal capacitors, and thick film chip resistors. A small signal model that emulates the operation of the 4H-SiC SIT from 25 to 400ºC, with an emphasis on operation at 400οC, was utilized. Measurements were performed from 25 to 400ºC to generate current-voltage curves, capacitive transistor characteristics and high frequency scattering parameters (S-parameters). The measured data was used to extrapolate the transconductance, gm, as a function of temperature for model development. Circuit simulation tools were used to generate S-parameters, which were compared to the measured values. At 400οC, a maximum difference between measured and simulated S-parameters for frequencies from 20 to 100 MHz were 3.84%, 0.68%, 10.61%, and 3.26% for S21, S12, S11, and S22, respectively. The average transit frequency, ft, was calculated from measured values to be 197.8 MHz, while the simulated value from the model was found to be 200 MHz. The Amplifier’s S-parameters were recorded at 20-100 MHz over a temperature range of 25-400ºC and show a gain of approximately 15.8 and 5.80 dBm at 25 and 400ºC, respectively. The input and output reflection coefficients at 50 MHz and 400ºC were -18.5 and -15.2 dB, respectively. The noise figure and phase noise were measured over the temperature range of 25-400ºC and recorded. The noise figure increased 21% at 50 MHz over the temperature range, while the 1 kHz offset of the phase noise remained below -110 dB. The stability factor, K, calculated with measured and simulated data demonstrates unconditional stability over the frequency range at 400ºC. Lastly, the 1-dB compression point was measured at 50 MHz and 400ºC with an approximated output of 9.5 dBm.

SiC↗

Solar Radiometry and Metrology, Session: Modeling and Analysis (Presentation)

This project supports the Solar America Initiative by: (1) Providing solar radiometric measurements, data, and related technical information support to NREL Measurements and Characterization Task; NREL Reliability and Durability Task; Systems and component testing and evaluation for the SAI TPPs; Requests from industry; (2) Producing credible radiometric measurements traceable to recognized standards for performance and Industry applications in accordance with IS0-17025 accreditation scope; (3) Contributing to consensus codes and standards for performance and measurement techniques for NREL R&D, SAI TPPs, and industry applications; (4) Maintain stability of the NREL solar radiation reference (absolute cavity radiometers); (5) Execute high quality detailed radiometric calibrations for broadband and spectral radiometers to meet NREL research and PV industry needs; (6) Participate in national and international consensus standards development, contributing technical expertise, data, and analysis where appropriate; (7) Provide technical information on solar radiation resource data and applications to meet research and industry needs; and (8) Transfer technology in this area to other researchers and industry via publications and conference papers and presentations.

14 SOLAR ENERGY↗

SCALE 6.3 Validation: Spent Nuclear Fuel

This report is the fifth volume in a series documenting the validation of SCALE 6.3 with ENDF/B-VII.1 libraries for nuclear criticality safety, reactor physics, radiation shielding, and spent nuclear fuel applications. This fifth volume, which focuses on validating SCALE capabilities that impact spent nuclear fuel applications, provides an update of the similar validation reported for SCALE 6.2.4. The experimental data used as basis for validation herein consist of measurement data for nuclide inventories and decay heat, including the following: 1. radiochemical assay (RCA) measurements of nuclides important to burnup credit, decay heat, and radiation shielding in 205 light-water reactor (LWR) spent nuclear fuel samples that cover burnups ranging up to 80 GWd/MTU and initial fuel enrichments up to 4.9% 235U; 2. full-assembly decay heat measurements for 236 LWR assemblies with initial fuel enrichments ranging up to 4% 235 U, assembly burnups of 5–51 GWd/MTU, and decay times after fuel discharge in the 2- to 27-year range (of importance to spent nuclear fuel storage, transportation, and disposal); and 3. pulse fission irradiations for fissionable materials at cooling times of interest to severe accident analyses (<10 5 s).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ground Reflectance Measurements from Thematic Mapper Data

Satellite radiance data are measures of solar radiation that has been reflected by the Earth's surface and scattered and absorbed by atmospheric gases and aerosols. Of concern to geologists are the surface reflectance and the degrading effects on surface resolution and albedo contrast introduced by atmospheric phenomena. The objects of this research have been to: (1) provide an empirical relationship between scanner radiance and ground reflectance allowing interpretation of the satellite data in terms of the surface parameter, and (2) assess the precision with which surface spectral reflectance may be recovered from LANDSAT-4 TM data in the presence of perturbing atmospheric and instrumental factors. The approach is field-oriented, and utilizes ground observations of surface spectral reflectance with portable spectrometers and radiometers to develop the required empirical relationships.

Conel, J. E.↗

STAYSL PNNL Suite

The STAYSL PNNL Suite of software provides a set of tools for working with neutron activation rates measured in a nuclear fission reactor, an accelerator-based neutron source, or any neutron field to determine the neutron flux spectrum through a generalized least-squares approach. This process is referred to as neutron spectral adjustment since the preferred approach is to use measured data to adjust neutron spectra provided by neutron physics calculations. The input data consist of the reaction rates based on measured activities, an initial estimate of the neutron flux spectrum, neutron activation cross sections and their associated uncertainties (covariances), and relevant correction factors. The output consists of the adjusted neutron flux spectrum and associated covariance matrix, which is useful for neutron dosimetry and radiation damage calculations. The software suite consists of the STAYSL PNNL, SHIELD, BCF, and NJpp Fortran codes and the SigPhi Calculator spreadsheet tool. In addition, the development of this software suite and associated data libraries used the third-party NJOY99 Fortran code (http://t2.lanl.gov/nis/codes/njoy99/). The NJOY99 and NJpp codes are used to assemble cross section and covariance input data libraries (for both SHIELD and STAYSL PNNL) from the International Reactor Dosimetry File of 2002 (IRDF-2002; http://www-nds.iaea.org/irdf2002/) developed by the Nuclear Data Section of the International Atomic Energy Agency (Vienna, Austria). The BCF, SigPhi Calculator, and SHIELD software tools are used to calculate corrected activation rates and neutron self-shielding correction factors, which are inputs to the STAYSL PNNL code.

Greenwood, L.R.↗

Quantification of the 35 Cl($\textit{n, p}$) reaction channel

The evaluated 35 Cl($\textit{n, p}$) cross sections in the ENDF/B-VIII.0 nuclear data library remain uncertain because of the lack of measured data in the neutron energy range between 100-600 keV. In this energy region, the R-matrix analysis relies heavily on estimated ($\textit{n, p}$) partial widths and level density information. This resulted in significant differences of the evaluated cross sections and predicted reactivity in nuclear reactor applications with respect to previous nuclear data libraries. Here, we present a methodology to quantify the cross sections for the 35 Cl($\textit{n, p}$) reaction channel from the combination of measured total cross sections and model calculations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Uncertainty Evaluation of Measurements with Pyranometers and Pyrheliometers

Evaluating photovoltaic (PV) cells, modules, arrays and systems performance of solar energy relies on accurate measurement of the available solar radiation resources. Solar radiation resources are measured using radiometers such as pyranometers (global horizontal irradiance) and pyrheliometers (direct normal irradiance). The accuracy of solar radiation data measured by radiometers depends not only on the specification of the instrument but also on a) the calibration procedure, b) the measurement conditions and maintenance, and c) the environmental conditions. Therefore, statements about the overall measurement uncertainty can only be made on an individual basis, taking all relevant factors into account. This paper provides guidelines and recommended procedures for estimating the uncertainty in measurements by radiometers using the Guide to the Expression of Uncertainty (GUM) Method. Special attention is paid to the concept of data availability and its link to uncertainty evaluation.

14 SOLAR ENERGY↗

An experimental palladium-103 seed (OptiSeed{sup exp}) in a biocompatible polymer without a gold marker: Characterization of dosimetric parameters including the interseed effect

Permanent implantation of {sup 125}I (iodine) or {sup 103}Pd (palladium) sources is a popular treatment option in the management of early stage prostate cancer. New sources are being developed, some of which are being marketed for different clinical applications. A new technique of adjuvant stereotactic permanent seed breast implant, similar to that used in the treatment of prostate cancer, has been proposed by [N. Jansen et al., Int. J. Radiat. Oncol. Biol. Phys. 67, 1052-1058 (2007)] with encouraging results. The presence of artifacts from the metallic seeds, however, can disturb follow-up imaging. The development of plastic seeds has reduced these artifacts. This paper presents a feasibility study of the advantages of palladium-103 seeds, encapsulated with a biocompatible polymer, for future clinical applications, and on the effect of the gold marker on the dosimetric characteristics of such seeds. Experimental palladium seeds, OptiSeed{sup exp}, were manufactured by International Brachytherapy (IBt), Seneffe, Belgium, from a biocompatible polymer, including the marker. Apart from the absence of a gold marker, the studied seed has an identical design to the OptiSeed{sup 103}[Phys. Med. Biol. 50, 1493-1504 (2005)]; [Appl. Radiat. Isot. 63, 311-321 (2005)]. Polymer encapsulation was preferred by IBt in order to reduce the quantity of radioactive material needed for a given dose rate and to reduce the anisotropy of the radiation field around the seed. In addition, this design is intended to decrease the interseed effects that can occur as a result of the marker and the encapsulation. Dosimetric measurements were performed using LiF thermoluminescent dosimeters (1 mm{sup 3}) in solid water phantoms (WT1). Measured data were compared to Monte Carlo simulated data in solid water using the MCNP code, version 4C. Updated cross sections [Med. Phys. 30, 701-711 (2003)] were used. As the measured and calculated data were in agreement, Monte Carlo calculations were then performed in liquid water to obtain relevant dosimetric data as required by TG-43U1 recommendations. Comparison of the results with previous studies of OptiSeed{sup 103}[Phys. Med. Biol. 50, 1493-1504 (2005)]; [Appl. Radiat. Isot. 63, 311-321 (2005)], and of InterSource{sup 103}[Appl. Radiat. Isot. 57, 805-811 (2002)] showed very good agreement for the dose rate constant and for the radial dose function. With respect to the anisotropy function, the relative dose (anisotropy value relative to 90 degree sign ) from the polymer seed at a distance of 3 cm was close to unity (105%) at 0 degree sign , whereas the relative values for the OptiSeed{sup 103} with a gold marker and the titanium-encapsulated InterSource{sup 103} seed decreased to 70% and 40%, respectively. The interseed effect from one seed was negligible and in the order of calculation uncertainty, making calculation of the dose rate distribution of the studied seeds, according to TG43U1 recommendations, more accurate and closer to reality. This feasibility study shows that due to the low energy of palladium-103, the negligible interseed effect and the reduced artifacts in postimplant medical imaging, this experimental plastic seed would be a good source for breast brachytherapy. This feasibility study was carried out in collaboration with IBt and will be continued with a study of its visibility in different tissues.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SO2 absorption cross sections in the near U.V.

In order to understand data measured by the TOMS instrument on Nimbus 7 after the eruption of El Chichon, absorption cross sections are measured in SO2 between 3000 and 3240 A at 295 and 210 K. Errors for these measurements range from less than 2 percent to about 10 percent. Measurements in the 3175 + or 5 A spectral region observed by TOMS indicate that there is a 9 percent reduction in the average cross section at 210 K compared to room-temperature data. Peak cross sections measured at low temperature show increases up to 20 percent over room-temperature data, while cross-section decreases are measured at low temperatures in the areas between the strong features.

Mcgee, Thomas J.↗

Predicting Reactor Antineutrino Emissions Using New Precision Beta Spectroscopy

Neutrino experiments at nuclear reactors are currently vital to the study of neutrino oscillations. The observed antineutrino rates at reactors are typically lower than model expectations. This observed deficit is called the “reactor neutrino anomaly”. A new understanding of neutrino physics may be required to explain this deficit, though model estimation uncertainties may also play a role in the apparent discrepancy. PNNL is currently investigating an experimental technique that promises reduced uncertainties for measured data to support these hypotheses and interpret reactor antineutrino measurements. The experimental approach is to 1) direct a proton accelerator beam on a metal target to produce a source of neutrons, 2) use spectral tailoring to modify the neutron spectrum to closely simulate the energy distribution of a power reactor neutron spectrum, 3) irradiate isotopic fission foils (235U, 238U, 239Pu, 241Pu) in this neutron spectrum so that fissions occur at energies representative of a reactor, 4) transport the beta particles released by the fission products in the foils to a beta spectrometer, 5) measure the beta energy spectrum, and 6) invert the measured beta energy spectrum to an antineutrino energy spectrum. A similar technique using a beta spectrometer and isotopic fission foils was pioneered in the 1980’s at the ILL thermal reactor. Those measurements have been the basis for interpreting all subsequent antineutrino measurements at reactors. A basic constraint in efforts to reduce uncertainties in predicting the antineutrino emission from reactor cores is any underlying limitation of the original measurements. This may include beta spectrum energy resolution, the absolute normalization of beta emission to number of fission, statistical counting uncertainties, lack of 238U data, the purely thermal nature of the IIL reactor neutrons used, etc. An accelerator-based neutron source that can be tailored to match various reactor neutron spectra provides an advantage for control in studying how changes in the neutron spectra (i.e. "in the reactor core") affects the resulting fission product beta spectrum. Furthermore, the 238U antineutrino spectrum, which has not been measured, can be studied directly because of the enhanced 1 MeV fast neutron flux available at the accelerator source. A facility such as the Project X Injector Experiment (PXIE) 30 MeV proton linear accelerator at Fermilab is being considered for this experiment. The hypothesis is that a new approach utilizing the flexibility of an accelerator neutron source with spectral tailoring coupled with a careful design of an isotopic fission target and beta spectrometer and the inversion of the beta spectrum to the neutrino spectrum will allow further reduction in the uncertainties associated with prediction of the reactor antineutrino spectrum.

Asner, David M.↗

SU-F-T-371: Development of a Linac Monte Carlo Model to Calculate Surface Dose

Purpose: To generate and validate a linac Monte Carlo (MC) model for surface dose prediction. Methods: BEAMnrc V4-2.4.0 was used to model 6 and 18 MV photon beams for a commercially available linac. DOSXYZnrc V4-2.4.0 calculated 3D dose distributions in water. Percent depth dose (PDD) and beam profiles were extracted for comparison to measured data. Surface dose and at depths in the buildup region was measured with radiochromic film at 100 cm SSD for 4 × 4 cm{sup 2} and 10 × 10 cm{sup 2} collimator settings for open and MLC collimated fields. For the 6 MV beam, films were placed at depths ranging from 0.015 cm to 2 cm and for 18 MV, 0.015 cm to 3.5 cm in Solid Water™. Films were calibrated for both photon energies at their respective dmax. PDDs and profiles were extracted from the film and compared to the MC data. The MC model was adjusted to match measured PDD and profiles. Results: For the 6 MV beam, the mean error(ME) in PDD between film and MC for open fields was 1.9%, whereas it was 2.4% for MLC. For the 18 MV beam, the ME in PDD for open fields was 2% and was 3.5% for MLC. For the 6 MV beam, the average root mean square(RMS) deviation for the central 80% of the beam profile for open fields was 1.5%, whereas it was 1.6% for MLC. For the 18 MV beam, the maximum RMS for open fields was 3%, and was 3.1% for MLC. Conclusion: The MC model of a linac agreed to within 4% of film measurements for depths ranging from the surface to dmax. Therefore, the MC linac model can predict surface dose for clinical applications. Future work will focus on adjusting the linac MC model to reduce RMS error and improve accuracy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multi-dimensional modeling of mixture preparation in a direct injection engine fueled with gaseous hydrogen

With the recent advances of direct injection (DI) technology, introducing hydrogen into the combustion chamber through DI is being considered as a viable approach to circumvent backfire and pre-ignition encountered in early generations of hydrogen engines. As part of a broader vision to develop a robust numerical model to study hydrogen spark ignition (SI) combustion in internal combustion (IC) engines, the present numerical investigation focuses on mixture preparation in a hydrogen DI SI engine. This study is carried out with a single hole injector with gaseous hydrogen injected at 100 bar injection pressure. Simulations are carried out for high and low tumble configurations and validated against optical data acquired from planar laser induced fluorescence (PLIF) measurements. Varying mesh configurations are investigated for the impact on in-cylinder mixture distribution. A particular emphasis is placed on the effect of nozzle geometry and mesh orientation near the wall. Overall, the computational model is found to predict the mixture distribution in the combustion cylinder reasonably well. The results showed that the alignment of mesh with the flow direction is important to achieve good agreement between numerical analysis and optical measurement data.

08 HYDROGEN↗

SU-F-T-620: Development of a Convolution/Superposition Dose Engine for CyberKnife System

Purpose: Current CyberKnife treatment planning system (TPS) provided two dose calculation algorithms: Ray-tracing and Monte Carlo. Ray-tracing algorithm is fast, but less accurate, and also can’t handle irregular fields since a multi-leaf collimator system was recently introduced to CyberKnife M6 system. Monte Carlo method has well-known accuracy, but the current version still takes a long time to finish dose calculations. The purpose of this paper is to develop a GPU-based fast C/S dose engine for CyberKnife system to achieve both accuracy and efficiency. Methods: The TERMA distribution from a poly-energetic source was calculated based on beam’s eye view coordinate system, which is GPU friendly and has linear complexity. The dose distribution was then computed by inversely collecting the energy depositions from all TERMA points along 192 collapsed-cone directions. EGSnrc user code was used to pre-calculate energy deposition kernels (EDKs) for a series of mono-energy photons The energy spectrum was reconstructed based on measured tissue maximum ratio (TMR) curve, the TERMA averaged cumulative kernels was then calculated. Beam hardening parameters and intensity profiles were optimized based on measurement data from CyberKnife system. Results: The difference between measured and calculated TMR are less than 1% for all collimators except in the build-up regions. The calculated profiles also showed good agreements with the measured doses within 1% except in the penumbra regions. The developed C/S dose engine was also used to evaluate four clinical CyberKnife treatment plans, the results showed a better dose calculation accuracy than Ray-tracing algorithm compared with Monte Carlo method for heterogeneous cases. For the dose calculation time, it takes about several seconds for one beam depends on collimator size and dose calculation grids. Conclusion: A GPU-based C/S dose engine has been developed for CyberKnife system, which was proven to be efficient and accurate for clinical purpose, and can be easily implemented in TPS.

60 APPLIED LIFE SCIENCES↗

User Guide for the STAYSL PNNL Suite of Software Tools

The STAYSL PNNL software suite provides a set of tools for working with neutron activation rates measured in a nuclear fission reactor, an accelerator-based neutron source, or any neutron field to determine the neutron flux spectrum through a generalized least-squares approach. This process is referred to as neutron spectral adjustment since the preferred approach is to use measured data to adjust neutron spectra provided by neutron physics calculations. The input data consist of the reaction rates based on measured activities, an initial estimate of the neutron flux spectrum, neutron activation cross sections and their associated uncertainties (covariances), and relevant correction factors. The output consists of the adjusted neutron flux spectrum and associated covariance matrix, which is useful for neutron dosimetry and radiation damage calculations.

Reactor dosimetry, neutron spectral adjustment↗

3D CFD Model Validation Using Benchmark Data of 1/16th Scaled VHTR Upper Plenum and Development of Wall Heat-Transfer Correlation For Laminar Flow

With support from the U.S. Department of Energy-Office of Nuclear Energy’s (DOE-NE’s) Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, an effort has been pursued to support high-temperature gas-cooled reactor (HTGR) technology development and its modeling and simulation needs. There is a particular need for advanced modeling and simulation tools to predict thermal-fluid behavior in the nuclear reactor primary system, especially in the core and the lower and upper plena, during safety-related transients. In this report, two main such activities are presented relevant to the HTGRs: (1) three-dimensional (3D) computational fluid dynamics (CFD) validation using benchmark data from the upper plenum of Texas A&M University’s 1/16th scaled very-high-temperature gas-cooled reactor (VHTR), and (2) development of wall heat-transfer correlation for laminar flow in a wall-heated pipe. The CFD tool validation exercises can be helpful to choose the models and CFD tools to simulate and design specific components of the HTRGs such as upper plenum where jet mixing is a complex phenomenon. In a loss of forced circulation event, the laminar flow can be observed during the development of natural circulation flow. This work includes the development and validation of heat transfer correlations for laminar flow using the Nek5000 CFD code due to limited available experimental data for laminar flow conditions to guide low-order models (1D). In this report, the flow characteristics of a single isothermal jet discharging into the upper plenum was investigated using the Nek5000 Large-Eddy Simulation (LES) CFD tool. Several numerical simulations were performed for various jet-discharged Reynolds numbers ranging from 3,413 to 12,819. A grid-independent study was performed. The numerical results of mean velocity, root-mean-square fluctuating velocity, and Reynolds stress were compared against the benchmark data. Good agreement was obtained between simulated and measured data for axial mean velocities, except near the upper plenum hemisphere. The maximum predicted errors for axial mean velocities at various normalized coolant channel diameter heights of 1, 5, and 10 are 1.56%, 1.88%, and 3.82%, respectively. In addition, the predicted root-mean-square fluctuating velocity and Reynolds stress are qualitatively in agreement with the experimental data. The Nek5000 code was used to develop wall-heat transfer correlation for laminar flow in a cylindrical tube. Several simulations were performed for various Reynolds flow and wall-heat fluxes. A new heat transfer correlation was developed using data from Nek5000 simulation results and regression functions in Matlab. The developed heat transfer correlation is valid for various Reynolds flows from 200 to 2000. The predicted R² value for model fit was 0.875, which ensures that 87.5% of the model data lies on the Nek5000 data. Moreover, a machine learning (ML) tool was used to train and test the Nek5000 data. A good fit of the ML-based model was observed with the test data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗