Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “liquid cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Development of a Pressure Box to Evaluate Reusable-Launch-Vehicle Cryogenic-Tank Panels

A cryogenic pressure-box test machine has been designed and is being developed to test full-scale reusable-launch-vehicle cryogenic-tank panels. This machine is equipped with an internal pressurization system, a cryogenic cooling system, and a heating system to simulate the mechanical and thermal loading conditions that are representative of a reusable-launch-vehicle mission profile. The cryogenic cooling system uses liquid helium and liquid nitrogen to simulate liquid hydrogen and liquid oxygen tank internal temperatures. A quartz lamp heating system is used for heating the external surface of the test panels to simulate cryogenic-tank external surface temperatures during re-entry of the launch vehicle. The pressurization system uses gaseous helium and is designed to be controlled independently of the cooling system. The tensile loads in the axial direction of the test panel are simulated by means of hydraulic actuators and a load control system. The hoop loads in the test panel are reacted by load-calibrated turnbuckles attached to the skin and frame elements of the test panel. The load distribution in the skin and frames can be adjusted to correspond to the tank structure by using these turnbuckles. The seal between the test panel and the cryogenic pressure box is made from a reinforced Teflon material which can withstand pressures greater than 52 psig at cryogenic temperatures. Analytical results and tests on prototype test components indicate that most of the cryogenic-tank loading conditions that occur in flight can be simulated in the cryogenic pressure-box test machine.

Ambur, Damodar R.↗

Development of a Pressure Box to Evaluate Reusable-Launch-Vehicle Cryogenic-Tank Panels

A cryogenic pressure-box test machine has been designed and is being developed to test full-scale reusable launch vehicle cryogenic-tank panels. This machine is equipped with an internal pressurization system, a cryogenic cooling system, and a heating system to simulate the mechanical and thermal loading conditions that are representative of a reusable launch vehicle mission profile. The cryogenic cooling system uses liquid helium and liquid nitrogen to simulate liquid hydrogen and liquid oxygen tank internal temperatures. A quartz lamp heating system is used for heating the external surface of the test panels to simulate cryogenic-tank external surface temperatures during re-entry of the launch vehicle. The pressurization system uses gaseous helium and is designed to be controlled independently of the cooling system. The tensile loads in the axial direction of the test panel are simulated by means of hydraulic actuators and a load control system. The hoop loads in the test panel are reacted by load-calibrated turnbuckles attached to the skin and frame elements of the test panel. The load distribution in the skin and frames can be adjusted to correspond to the tank structure by using these turnbuckles. The seal between the test panel and the cryogenic pressure box is made from a reinforced Teflon material which can withstand pressures greater than 52 psig at cryogenic temperatures. Analytical results and tests on prototype test components indicate that most of the cryogenic-tank loading conditions that occur in flight can be simulated in the cryogenic pressure-box test machine.

Ambur, Damodar R.↗

Environmental loading effects on structures

The environment in which a structure vibrates influences its modal characteristics. Presented herein is experimental modal survey test results on splitter vanes under liquid nitrogen mass-pressure-thermal loading. In particular, shifts in modal frequencies are studied via frequency response functions, power spectral densities, isoplots, quadrature or imaginary plots, and vibration mode shape characteristics generated from strain and acceleration measurements. Analyses have shown that while mass loading lowers the frequencies, increased pressure and lower temperature have opposite effect. Thus, pressurization and cooling of a liquid causes the modal frequencies of the structure in which it is contained to shift upward.

Panossian, H. V.↗

Experimental Validation of Thermal Hydraulic Behavior in Sodium Fast Reactors (SFR) with the Thermal Hydraulic Experimental Test Article (THETA)

Thermal stratification and transition to natural circulation pose two of the largest sources of uncertainty in systems-level modeling of liquid metal-cooled fast reactors. As these phenomena typically develop during transient event sequences, licensing-basis events analyzed using systemslevel models may have considerable uncertainties associated with thermal-hydraulic parameters of the system to account for these phenomena. As a result, the validation basis for these phenomena for systems-level codes is insufficient to fully support the wide range of liquid metal fast reactors being developed in the US. Currently, the most viable path for licensing a design is to take significant conservatisms and maintain sufficiently large safety margins to account for this uncertainty.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Method Based on Radiative Cooling for Detecting Structural Changes in Undercooled Metallic Liquids

We introduce a structure-sensitive parameter for undercooled melts which can be measured in containerless processing experiments. We have established that the ratio, R(T), of hemispherical total emissivity epsilon(sub T)(T) to constant-pressure specific heat c(sub p)(T) can serve as an indicator which is sensitive to any changes in short range atomic order in undercooled metallic melts. R(T) (triple bonds) epsilon(sub T)(T)/c(sub p)(T) values for nickel, zirconium, and silicon have been obtained using the high temperature electrostatic levitator while the levitated melts were undergoing purely radiative cooling into the deeply undercooled region. R(T) plots for undercooled liquid nickel and zirconium indicate no significant change in short-range structure from their melting temperatures to 15% undercooling. In contrast, liquid silicon shows marked short-range structural changes beginning above its melting temperature and extending throughout the undercooled region. The short-range structure of liquid silicon is related to the highly-directional covalent bonding which characterizes its solid form. The nickel and zirconium data show that epsilon(sub T) varies linearly with T, in support of metal emissivity theories.

Rulison, Aaron J.↗

Using Mylar-Insulated Cryopumping Panels to Improve Vacuum Level During Warm Temperature Testing at JSC's Large Thermal Vacuum Facilities

Johnson Space Center’s Space Environment Simulation Lab (SESL) has both Chamber A, the world’s largest purpose-built thermal vacuum chamber capable of creating deep space conditions, and Chamber B, the largest human rated thermal vacuum chamber. A unique design feature of these chambers is the gaseous helium cryopumping panels within the liquid nitrogen shroud. This shroud is used to bring the chamber to cryogenic temperatures while the cryopumping panels trap gasses on its surface area to create a high vacuum environment of 5*10-6 Torr. In preparation for the James Webb Space Telescope (JWST) flight test, a series of functionals required the chamber to run at higher temperatures, and therefore did not need active cooling from the liquid nitrogen shroud. During testing, cryopumping panels were used to mitigate contamination during this main shroud warm-up. One of the cryopumping panels in Chamber A was covered with several layers of aluminized mylar to thermally protect the zone from the warmed shroud. This strategy was effective and became part of operations during JWST testing. Currently, Chamber B has requests for both commercial and NASA space suit tests at both high and low temperatures to validate thermal models. High temperature tests could benefit from reduced heater demand with an insulated shroud while still sustaining the high vacuum environment provided by the cryopumping panels. This paper will quantitatively define the thermal loads on the panels used in previous Chamber A warm up sequences. Additionally, this report will perform thermal analyses to assess the feasibility of adding layers of aluminized mylar to the cryopumping panels of Chamber B.

Cryogenics↗

Integrated sample-handling and mounting system for fixed-target serial synchrotron crystallography

Serial synchrotron crystallography (SSX) is enabling the efficient use of small crystals for structure–function studies of biomolecules and for drug discovery. An integrated SSX system has been developed comprising ultralow background-scatter sample holders suitable for room and cryogenic temperature crystallographic data collection, a sample-loading station and a humid `gloveless' glovebox. The sample holders incorporate thin-film supports with a variety of designs optimized for different crystal-loading challenges. These holders facilitate the dispersion of crystals and the removal of excess liquid, can be cooled at extremely high rates, generate little background scatter, allow data collection over >90° of oscillation without obstruction or the risk of generating saturating Bragg peaks, are compatible with existing infrastructure for high-throughput cryocrystallography and are reusable. The sample-loading station allows sample preparation and loading onto the support film, the application of time-varying suction for optimal removal of excess liquid, crystal repositioning and cryoprotection, and the application of sealing films for room-temperature data collection, all in a controlled-humidity environment. The humid glovebox allows microscope observation of the sample-loading station and crystallization trays while maintaining near-saturating humidities that further minimize the risks of sample dehydration and damage, and maximize working times. This integrated system addresses common problems in obtaining properly dispersed, properly hydrated and isomorphous microcrystals for fixed-orientation and oscillation data collection. Its ease of use, flexibility and optimized performance make it attractive not just for SSX but also for single-crystal and few-crystal data collection. Fundamental concepts that are important in achieving desired crystal distributions on a sample holder via time-varying suction-induced liquid flows are also discussed.

47 OTHER INSTRUMENTATION↗

Using Mylar-Insulated Cryopumping Panels to Improve Vacuum Level During Warm Temperature Testing at JSCs Large Thermal Vacuum Facilities

The Johnson Space Center’s Space Environment Simulation Lab (SESL) has both Chamber A, the world’s largest purpose-built thermal vacuum chamber capable of creating deep space conditions, and Chamber B, the largest human rated thermal vacuum chamber. A unique design feature of these chambers is the gaseous helium cryopumping panels within the liquid nitrogen shroud. This shroud is used to bring the chamber to cryogenic temperatures while the cryopumping panels trap gasses using their large surface area in order to create a high vacuum environment of 5*10^-6 Torr. In preparation for the James Webb Space Telescope (JWST) flight test, a series of functionals required the chamber to run at higher temperatures, and therefore did not need active cooling from the liquid nitrogen shroud. During testing, cryopumping panels were used to mitigate contamination during this main shroud warm-up. One of the cryopumping panels in Chamber A was covered with several layers of aluminized mylar in order to thermally protect the zone from the warmed shroud. This strategy was effective and became part of operations during JWST testing. Currently, Chamber B has requests for both commercial and NASA space suit tests at both high and low temperatures to accurately generate thermal models. High temperature tests would greatly benefit from simultaneous shroud warming and the high vacuum environment provided by the cryopumping panels. This paper will quantitatively define the thermal loads on the panels used in previous Chamber A warm up sequences. Additionally, this report will perform a thermal analysis to judge the feasibility of adding layers of aluminized mylar to the cryopumping panels of Chamber B.

Cryogenics↗

Using Mylar-Insulated Cryopumping Panels to Improve Vacuum Level During Warm Temperature Testing at JSC's Large Thermal Vacuum Facilities

The Johnson Space Center’s Space Environment Simulation Lab (SESL) has both Chamber A, the world’s largest purpose-built thermal vacuum chamber capable of creating deep space conditions, and Chamber B, the largest human rated thermal vacuum chamber. A unique design feature of these chambers is the gaseous helium cryopumping panels within the liquid nitrogen shroud. This shroud is used to bring the chamber to cryogenic temperatures while the cryopumping panels trap gasses using their large surface area in order to create a high vacuum environment of 5*10^-6 Torr. In preparation for the James Webb Space Telescope (JWST) flight test, a series of functionals required the chamber to run at higher temperatures, and therefore did not need active cooling from the liquid nitrogen shroud. During testing, cryopumping panels were used to mitigate contamination during this main shroud warm-up. One of the cryopumping panels in Chamber A was covered with several layers of aluminized mylar in order to thermally protect the zone from the warmed shroud. This strategy was effective and became part of operations during JWST testing. Currently, Chamber B has requests for both commercial and NASA space suit tests at both high and low temperatures to accurately generate thermal models. High temperature tests would greatly benefit from simultaneous shroud warming and the high vacuum environment provided by the cryopumping panels. This paper will quantitatively define the thermal loads on the panels used in previous Chamber A warm up sequences. Additionally, this report will perform a thermal analysis to judge the feasibility of adding layers of aluminized mylar to the cryopumping panels of Chamber B.

Cryogenics↗

Development of Cryogenic Phase Change Materials for Lunar Sample Return

One of the scientific goals of NASA’s Artemis missions is to return regolith samples from the lunar surface. To maintain scientific integrity of these samples, including any volatiles that may exist, cryogenic stowage is desired. FROSTE (Frozen Return Of Samples To Earth) is the element of the Moon to Mars architecture that is tasked with developing and advancing concepts related to this goal. Both active and passive solutions are being considered, but active solutions (cryo-coolers) have high mass and cost penalties. Phase change materials (PCMs) are commonly used as passive thermal management solutions, particularly for sensitive scientific samples. However, there are currently no PCMs capable of providing cooling at the cryogenic temperatures needed to enable lunar sample return with volatiles intact (<120 K). FROSTE has identified two possible candidate materials that could fill this gap. Testing is required to verify the thermal performance of these materials, as well as gain experience with their handling characteristics. We are conducting this testing at the Marshall Space Flight Center’s Space Environmental Effects laboratory, in vacuum, with liquid nitrogen providing cooling ability below the freezing point of the materials. In this talk, we will present an overview of the FROSTE program element and share results from the initial development testing of two cryogenic phase change materials.

phase change material↗

Technology Advancements for Channel Wall Nozzle Manufacturing In Liquid Rocket Engines

A regeneratively-cooled or dump-cooled nozzle is a critical component for expansion of hot gases to enable high temperature and performance in liquid rocket engines systems. Regeneratively-cooled channel wall nozzles are a design solution used across the propulsion industry as a simplified method to fabricate the nozzle structure with internal coolant passages. The scale and complexity of the channel wall nozzle (CWN) design can be challenging to fabricate which results in extended lead times and higher costs. Some of these challenges include: 1) Unique and high temperature materials, 2) Tight tolerances on large parts during manufacturing and assembly to contain high pressure propellants, 3) Thin-walled features to maintain adequate wall temperatures, and 4) Unique manufacturing process operations and complex tooling. The United States (U.S.) National Aeronautics and Space Administration (NASA) and U.S. specialty manufacturing vendors are maturing modern fabrication techniques to reduce complexity and decrease costs associated with channel wall nozzle manufacturing technology. Additive Manufacturing (AM) is one of the key technology advancements under evaluation for channel wall nozzles. Much of additive manufacturing for propulsion components has focused on laser powder bed fusion (L-PBF), but the scale is not yet feasible for application to large scale nozzles. NASA is evolving directed energy deposition (DED) techniques for nozzles including arc-based deposition, blown powder deposition, and Laser Wire Direct Closeout (LWDC). There are different approaches being considered for fabrication of the nozzle, and each of these DED processes offer unique process steps for rapid fabrication. The arc-based and blown powder deposition techniques are used for the forming of the CWN liner. A variety of materials are being demonstrated including Inconel 625, Haynes 230, JBK-75, and NASA HR-1. The blown powder DED process is also being demonstrated for forming an integral channel nozzle in a single operation in similar materials. The LWDC process is a method for closing out the channels within the liner and forming the structural jacket using a localized laser wire deposition technique. Identical materials mentioned above have been used for this process in addition to bimetallic closeout (C-18150–SS347, and C-18150–Inconel 625). NASA has completed process development, material characterization, and hot-fire testing on a variety of these channel wall nozzle fabrication technique. This publication presents an overview of the various channel wall nozzle manufacturing processes and materials under evaluation including results from the hot-fire testing. Future development and technology focus areas is also discussed relative to channel wall nozzle manufacturing.

Additive manufacturing↗

Rapid Quenching of Molten Salts as an Approach for the Coordination Characterization of Corrosion Products

A new apparatus was built to rapidly cool molten salts in liquid argon to prevent contamination during quenching and enable new insight into the structure in the liquid state. To test the applicability of the apparatus, several industrially relevant chloride salt compositions were first melted, rapidly solidified, and then characterized. The design proved applicable for the rapid quenching of molten salt. Furthermore, the structure of the apparatus prevented exposure of the rapidly quenched salt to impurities (humidity, oxygen, etc.). X-ray diffraction of salt specimens cooled with and without liquid argon showed differences including a structure further from the expected stoichiometric equilibrium with rapid cooling. Of particular interest is the chemical state of metallic impurities, and this may be probed using electron paramagnetic resonance.

36 MATERIALS SCIENCE↗

Space Power Facility Readiness for Space Station Power System Testing

This document provides information which shows that the NASA Lewis Research Center's Space Power Facility (SPF) will be ready to execute the Space Station electric power system thermal vacuum chamber testing. The SPF is located at LeRC West (formerly the Plum Brook Station), Sandusky, Ohio. The SPF is the largest space environmental chamber in the world, having an inside horizontal diameter of 100 ft. and an inside height at the top of the hemisphere of 122 ft. The vacuum system can achieve a pressure lower than 1 x 10(exp -5) Torr. The cryoshroud, cooled by gaseous nitrogen, can reach a temperature of -250 F, and is 80 ft. long x 40 ft. wide x 22 ft. high. There is access to the chamber through two 50 ft. x 50 ft. doors. Each door opens into an assembly area about 150 ft. long x 70 ft. wide x 80 ft. high. Other available facilities are offices, shop area, data acquisition system with 930 pairs of hard lines, 7 megawatts of power to chamber, 245K gal. liquid nitrogen storage, cooling tower, natural gas, service air, and cranes up to 25 tons.

Smith, Roger L.↗

Testing of Liquid Metal Components for Nuclear Surface Power Systems

The Early Flight Fission Test Facility (EFF-TF) was established by the Marshall Space Flight Center (MSFC) to provide a capability for performing hardware-directed activities to support multiple in-space nuclear reactor concepts by using a non-nuclear test methodology. This includes fabrication and testing at both the module/component level and near prototypic reactor configurations. The EFF-TF is currently supporting an effort to develop an affordable fission surface power (AFSP) system that could be deployed on the Lunar surface. The AFSP system is presently based on a pumped liquid metal-cooled (Sodium-Potassium eutectic, NaK-78) reactor design. This design was derived from the only fission system that the United States has deployed for space operation, the Systems for Nuclear Auxiliary Power (SNAP) 10A reactor, which was launched in 1965. Two prototypical components recently tested at MSFC were a pair of Stirling power conversion units that would be used in a reactor system to convert heat to electricity, and an annular linear induction pump (ALIP) that uses travelling electromagnetic fields to pump the liquid metal coolant through the reactor loop. First ever tests were conducted at MSFC to determine baseline performance of a pair of 1 kW Stirling convertors using NaK as the hot side working fluid. A special test rig was designed and constructed and testing was conducted inside a vacuum chamber at MSFC. This test rig delivered pumped NaK for the hot end temperature to the Stirlings and water as the working fluid on the cold end temperature. These test were conducted through a hot end temperature range between 400 to 550C in increments of 50 C and a cold end temperature range from 30 to 70 C in 20 C increments. Piston amplitudes were varied from 6 to 1 1mm in .5 mm increments. A maximum of 2240 Watts electric was produced at the design point of 550 hot end, 40 C cold end with a piston amplitude of 10.5mm. This power level was reached at a gross thermal efficiency of 28%. A baseline performance map was established for the pair of 1kW Stirling convertors. The performance data will then be used for design modification to the Stirling convertors. The ALIP tested at MSFC has no moving parts and no direct electrical connections to the liquid metal containing components. Pressure is developed by the interaction of the magnetic field produced by the stator and the current which flows as a result of the voltage induced in the liquid metal contained in the pump duct. Flow is controlled by variation of the voltage supplied to the pump windings. Under steady-state conditions, pump performance is measured for flow rates from 0.5-4.3 kg/s. The pressure rise developed by the pump to support these flow rates is roughly 5-65 kPa. The RMS input voltage (phase-to-phase voltage) ranges from 5-120 V, while the frequency can be varied arbitrarily up to 60 Hz. Performance is quantified at different loop temperature levels from 50 C up to 650 C, which is the peak operating temperature of the proposed AFSP reactor. The transient response of the pump is also evaluated to determine its behavior during startup and shut-down procedures.

Polzin, Kurt A.↗

Passive Cooling in Aerogel-Based Insulation Systems for Liquid Hydrogen Upper Stage Launch Vehicle Tanks

Spray-On Foam Insulation (SOFI) is typically used to protect the windward-facing side of flight tanks for space launch vehicle liquid hydrogen (LH2) stages. SOFI is an excellent insulator in ambient pressure environments, however, its performance pales in comparison to reflective-type systems such as Multi-Layer Insulation in the thermal radiation dominated vacuum environment of space. If a windward insulation system employing radiation shields could be devised to replace or supplement SOFI, the on-orbit heat load could be drastically reduced, and the residual propellants could then be used to facilitate secondary missions. Such insulation systems, utilizing aerogel blanket insulation, have been explored by the Cryogenics Test Laboratory at NASA Kennedy Space Center. Owing to its nano-porous structure, aerogel is an excellent adsorbent as well as an insulator at cryogenic temperatures and will readily uptake condensable background gasses such as air when protecting a surface near LH2 temperatures. When an adsorbed blanket is rapidly exposed to a vacuum, such as during the ascent of a rocket, it will release the background gas, producing a passive cooling effect that could potentially reduce or eliminate the heat load on the propellant tank for a time. This work discusses the setup and results of a test program carried out to determine the effectiveness and impact of this cooling effect as it pertains to LH2 upper stage tanks. A vertical-cylindrical liquid nitrogen (LN2) calorimeter test instrument acted as the upper stage analog. The cold-mass was wrapped with two layers of 10 mm thick aerogel blanket material, with and without aluminum heat shields depending on the test, and interspersed with numerous thermocouple temperature sensors. Gaseous argon was used as a stand-in for air as the condensable background gas. The test procedure mimicked vehicle cryo-loading/stabilization, and ascent phases, with the ascent phase accomplished using parallel vacuum pumps. Results show that the desorption cooling effect was enough to not only eliminate the heat load on the LN2 cold-mass entirely, but further refrigerated the liquid below its boiling point.

A.M. Swanger↗

Innovative Advanced Hydrogen Mobile Fueler (Final Technical Report)

The US Department of Energy (DOE) funded a project to design, develop, deploy and analyze the economic viability of an innovative Advanced Hydrogen Mobile Fueler (AHMF). As part of the design activity the project team defined specifications based upon vehicle requirements and compliance with specific fueling performance criteria. The AHMF was originally designed to fuel 10-20 fuel cell vehicles (FCV) per day, consistent with the requirements of the H70 fueling category. The AHMF is able to operate without remote power connections, is modular for easy transport and deployment, and can provide expanded daily capacity and multi-day operations using delivered gaseous hydrogen. Toward the end of the project, due to request from the hydrogen industry and some necessary modifications of the AHMF, the system is now modified to fuel heavy duty vehicles. The project was conducted over two primary phases, each including several key tasks, subtasks, and project milestones. Phase 1 involved the design, development, and construction of the AHMF, moving from a conceptual design through to completion of assembly and testing. In addition to reviewing several different approaches, the team chose to take a conventional station design and modify it for mobile fueling. There were several innovative components included in the design. The high pressure storage was the first to achieve a US Department of Energy (DOE) Special Permit (SP 20391) to transport high pressure hydrogen (95 MPa) in a composite cylinder. The second novel system was a liquid nitrogen (LIN) cooling system with a compact heat exchanger. Without this change, the cooling system would not be able to fit into the AHMF. Phase 2 demonstrated the AHMF by fueling fuel cell buses at a fleet in Pomona, CA. The site was chosen because a temporary fueling solution was required while a fixed station was being installed. The existing permits for the fixed station and non-public access also was a determining factor. Over two months, the buses were fueled 320 times with over 5000 kg of hydrogen from tube trailers. Existing shore power was used, and the average electrical efficiency was 0.13 kWh/kg. The average liquid nitrogen (LIN) consumption was 90.68 scf/kg. The fueling and consumption data was provided to the National Renewable Energy Laboratory (NREL) for analysis. An economic analysis was performed and will be provided in a separate report. The project was successful, but not without challenges and lessons learned. The DOT special permit led the way for the use of high pressure, composite cylinders and is being by multiple other systems and applications. The pandemic along with time for the DOT special permit approval delayed the project for years. The team also believes that hydrogen mobile fueling has a use for the industry, especially during this upcoming phase of expansion. However, it does have its limitations due to high cost to build and operate, and the same permitting challenges as a fixed station. A fully capable system at the speeds and pressures of the AHMF may not be necessary for most applications and would help reduce the cost and increase storage capacity. The on-board generator can be easily replaced with shore power or the wide range of power generation solutions in the marketplace. One of the major results of the project was the development of new code language in National Fire Protection Agency (NFPA) 2 and the International Fire Code (IFC) for on-demand mobile fueling. This will provide guidance for Authorities Having Jurisdiction (AHJ) and user on how to permit temporary fueling sites across the nation.

08 HYDROGEN↗

Flash Cracking Reactor for Waste Plastic Processing

Conversion of waste plastic to energy is a growing problem that is especially acute in space exploration applications. Moreover, utilization of heavy hydrocarbon resources (wastes, waxes, etc.) as fuels and chemicals will be a growing need in the future. Existing technologies require a trade-off between product selectivity and feedstock conversion. The objective of this work was to maintain high plastic-to-fuel conversion without sacrificing the liquid yield. The developed technology accomplishes this goal with a combined understanding of thermodynamics, reaction rates, and mass transport to achieve high feed conversion without sacrificing product selectivity. The innovation requires a reaction vessel, hydrocarbon feed, gas feed, and pressure and temperature control equipment. Depending on the feedstock and desired product distribution, catalyst can be added. The reactor is heated to the desired tempera ture, pressurized to the desired pressure, and subject to a sweep flow at the optimized superficial velocity. Software developed under this project can be used to determine optimal values for these parameters. Product is vaporized, transferred to a receiver, and cooled to a liquid - a form suitable for long-term storage as a fuel or chemical. An important NASA application is the use of solar energy to convert waste plastic into a form that can be utilized during periods of low solar energy flux. Unlike previous work in this field, this innovation uses thermodynamic, mass transport, and reaction parameters to tune product distribution of pyrolysis cracking. Previous work in this field has used some of these variables, but never all in conjunction for process optimization. This method is useful for municipal waste incinerator operators and gas-to-liquids companies.

Timko, Michael T.↗

High-heat transfer lithium-ion batteries: A new era in battery thermal management

Despite advances in lithium-ion battery technology, critical challenges remain that must be addressed to accelerate electric vehicle (EV) adoption and global energy transformation. Significantly improved battery thermal management (BTM) is key to overcoming these challenges. BTM approaches focus on increasing heat transfer coefficients via air, liquid, or refrigerant cooling, but less attention is given to reducing the battery's thermal resistance, a major bottleneck for heat transfer. This work introduces a novel approach to reduce battery thermal resistance by integrating in-plane heat transfer with optimized cell geometry, minimized thermal resistances, and reduced interfacial resistances, representing a departure from previous methods. The standard prismatic can cell incorporating this technology is referred to as the high heat transfer (HHT) battery. An equivalent resistance battery thermal model is developed for speed and accuracy, validated against experimental data in the literature, demonstrating strong correlation and ensuring reliable predictions for real-world performance. Thermal performance metrics of the conventional and HHT batteries are compared using a parametric study with air, liquid, and refrigerant boundary conditions across a range of aspect ratios. The HHT battery shows a heat removal rate up to 20 times higher than a conventional battery. These findings suggest that HHT technology could be transformative for EV battery performance, enabling fast charging, mitigating thermal runaway, extending battery life, reducing cold-weather power loss, increasing reliability, lowering costs, and enabling higher energy density, all critical for EV adoption and energy transformation. Future work will focus on prototyping and real-world testing to refine these findings for commercial-scale applications.

25 ENERGY STORAGE↗