Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “intervals”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Time-dependent amplitude analysis of B{sup 0}{yields}K{sub S}{sup 0}{pi}{sup +}{pi}{sup -}

We perform a time-dependent amplitude analysis of B{sup 0}{yields}K{sub S}{sup 0}{pi}{sup +}{pi}{sup -} decays to extract the CP violation parameters of f{sub 0}(980)K{sub S}{sup 0} and {rho}{sup 0}(770)K{sub S}{sup 0} and the direct CP asymmetry of K*{sup +}(892){pi}{sup -}. The results are obtained from a data sample of (383{+-}3)x10{sup 6} BB decays, collected with the BABAR detector at the PEP-II asymmetric-energy B factory at SLAC. We find two solutions, with an equivalent goodness-of-fit. Including systematic and Dalitz plot model uncertainties, the combined confidence interval for values of the CP parameter {beta}{sub eff} in B{sup 0} decays to f{sub 0}(980)K{sub S}{sup 0} is 18 deg. <{beta}{sub eff}<76 deg. at 95% confidence level (C.L). CP conservation in B{sup 0} decays to f{sub 0}(980)K{sub S}{sup 0} is excluded at 3.5 standard deviations including systematic uncertainties. For B{sup 0} decays to {rho}{sup 0}(770)K{sub S}{sup 0}, the combined confidence interval is -9 deg. <{beta}{sub eff}<57 deg. at 95% C.L. In decays to K*{sup +}(892){pi}{sup -} we measure the direct CP asymmetry to be A{sub CP}=-0.20{+-}0.10{+-}0.01{+-}0.02. The measured phase difference (including B{sup 0}B{sup 0} mixing) between decay amplitudes of B{sup 0}{yields}K*{sup +}(892){pi}{sup -} and B{sup 0}{yields}K*{sup -}(892){pi}{sup +}, excludes the interval -137 deg. <{delta}{phi}(K*{sup +}(892){pi}{sup -})<-5 deg. at 95% C.L.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Particle-number distribution in large fluctuations at the tip of branching random walks

Here, we investigate properties of the particle distribution near the tip of one-dimensional branching random walks at large times t , focusing on unusual realizations in which the rightmost lead particle is very far ahead of its expected position, but still within a distance smaller than the diffusion radius ~$\sqrt{t}$. Our approach consists in a study of the generating function $G_{Δx}(λ) = Σ_n$ ${λ^n}p_n(Δx)$ for the probabilities $p_n(Δx)$ of observing $\textit{n}$ particles in an interval of given size $Δ\textit{x}$ from the lead particle to its left, fixing the position of the latter. This generating function can be expressed with the help of functions solving the Fisher-Kolmogorov-Petrovsky-Piscounov (FKPP) equation with suitable initial conditions. In the infinite-time and large-$Δ\textit{x}$ limits, we find that the mean number of particles in the interval grows exponentially with $Δ\textit{x}$, and that the generating function obeys a nontrivial scaling law, depending on $Δ\textit{x}$ and λ through the combined variable $[Δx — f(λ)]^3 / Δx^2$, where $\textit{f}$(λ) ≡ – ln(1 – λ) – ln [– ln(1 – λ)]. From this property, one may conjecture that the growth of the typical particle number with the size of the interval is slower than exponential, but, surprisingly enough, only by a subleading factor at large Δ$\textit{x}$. The scaling we argue is consistent with results from a numerical integration of the FKPP equation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On the Effectiveness of Recurrent Neural Networks for Live Modeling of Cyber-Physical Systems

Attention to cyber security of cyber-physical systems (CPS) has led to the development of innovative cyber-resilient methodologies to ensure early detection and mitigation of cyber anomalies and threats. The concept of Digital Twin (DT) has recently emerged as one of the approaches to achieve the objective of resilience. In the approach using DT, a software-based live model of a target CPS is used to continuously monitor, surveil and verify the correctness of the target CPS operation. In this paper, we empirically study the effectiveness of Recurrent Neural Network (RNN)-based models as the basis of DT-based resilience. We uncover the important characteristics of an RNN-based solution with experimentation on a lab-scale Canal Lock CPS emulator with live validations and attack scenarios. For the first time, we demonstrate actual, real-time use of a RNN-based model as a DT for performing live analysis on an operational CPS. Based on the observed results, we highlight the importance of a DT model's training interval, prediction interval and CPS polling interval in the process of anomaly detection. We uncover the limitations in anomaly detection due to real-time synchronization needs of the RNN-based DT. We highlight this uncovered tug of war between synchronization and anomaly detection is inherent in any complex CPS that is monitored and synchronized by relying on the same sensor streams of ground truth for both synchronization as well as anomaly detection.

Yoginath, Srikanth↗

Advanced Metering Infrastructure for Distribution Planning and Operation: Closing the Loop on Grid-Edge Visibility

In the recent history of electric utilities, the potential to have visibility of the grid edge is gaining significance for the reliable planning and operation of a clean energy smart grid. Before the recent large-scale customer adoption of distributed energy resources (DERs), distribution networks were planned with a simpler fit-and-forget philosophy. The importance of customer-sited DERs to achieve climate change goals marks a major shift for utility operations. Changes to traditional fit-and-forget planning paradigms require better availability of grid-edge data. Smart metering is an enterprise-wide tool that is enabling visibility when and where it has been most needed. As of 2020, the rollout of smart metering, or advanced metering infrastructure (AMI), had reached more than 100 million meters in the United States, and nearly half of all electricity customers are now equipped with a smart meter (Figure 1). Smart meters are quickly becoming a ubiquitous data capture feature of smart grids. AMI enables utilities to record and measure electricity usage and power-flow metrics at a minimum of hourly intervals and at least once a day. At a minimum, AMI enables interval metering, automatic meter reading enabling accurate and time-interval billing, and the ability to provide feedback on customer energy consumption.

advanced metering infrastructure↗

Characterization of Fissile Assemblies Using Low-Efficiency Detection Systems

Here, we have investigated the possibility that the amount, chemical form, multiplication, and shape of the fissile material in an assembly can be passively assayed using scintillator detection systems by only measuring the fast neutron pulse height distribution and distribution of time intervals Δt between fast neutrons. We have previously demonstrated that the alpha-ratio can be obtained from the observed pulse height distribution for fast neutrons. In this paper we report that we report that when the distribution of time intervals is plotted as a function of logΔt, the position of the correlated neutron peak is nearly independent of detector efficiency and determines the internal relaxation rate for fast neutrons. If this information is combined with knowledge of the alpha-ratio, then the position of the minimum between the correlated and uncorrelated peaks can be used to rapidly estimate the mass, multiplication, and shape of fissile material. This method does not require a priori knowledge of either the efficiency for neutron detection or the alpha-ratio. Although our method neglects 3-neutron correlations, we have used previously obtained experimental data for metallic and oxide forms of Pu to demonstrate that our method yields good estimates for multiplications as large as 2, and that the only constraint on detector efficiency/observation time is that a peak in the interval time distribution due to correlated neutrons is visible.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Secondary Frequency Regulation from Variable Generation through Uncertainty Decomposition: An Economic and Reliability Perspective

The rapid integration of variable generation (VG), such as photovoltaics (PV), necessitates an increase in the secondary frequency regulation (SFR) to handle the system intra-dispatch interval imbalance because of VG's variation. Although PV has the control capability to provide SFR, the main challenge is in guaranteeing the delivery of PV's energy and SFRs capacities in the automatic generation control (AGC) within each dispatch interval considering its uncertainty. This paper proposes a deliverable VG SFR provision model with endogenous VG's power uncertainty decomposition. First, the uncertainty of VG is decomposed using distributionally robust chance constraints through which the deliverable SFR provision is guaranteed. Next, the intra-interval frequency response of PV's SFR is validated with a user defined AGC model including the PV power plant. Finally, the economic benefits and the reliability improvements such as the frequency deviation reduction with PV providing SFRcan be integrated and evaluated. The proposed model is tested in a modified 18-bus system and in the Western Electricity Coordinating Council test system. Results demonstrate that with the deliverable SFR from PV, the system cost and the frequency reliability can be improved simultaneously. PV's SFR performance can be guaranteed with the proposed model.

14 SOLAR ENERGY↗

Establishing reference ranges for circulating biomarkers of drug‐induced liver injury in healthy human volunteers 1

Aims The potential of mechanistic biomarkers to improve prediction of drug‐induced liver injury (DILI) and hepatic regeneration is widely acknowledged. We sought to determine reference intervals for new biomarkers of DILI and regeneration, as well as to characterize their natural variability and impact of diurnal variation. Methods Serum samples from 227 healthy volunteers were recruited as part of a cross‐sectional study; of these, 25 subjects had weekly serial sampling over 3 weeks, while 23 had intensive blood sampling over a 24h period. Alanine aminotransferase (ALT), MicroRNA‐122 (miR‐122), High Mobility Group Box‐1 (HMGB1), total Keratin‐18 (K18), caspase‐cleaved Keratin‐18 (ccK18), Glutamate Dehydrogenase (GLDH) and Macrophage Colony‐Stimulating Factor‐1 (CSF‐1) were assayed. Results Reference intervals were established for each biomarker based on the 97.5% quantile (90% CI) following the assessment of fixed effects in univariate and multivariable models. Intra‐individual variability was found to be non‐significant, and there was no significant impact of diurnal variation. Conclusion Reference intervals for novel DILI biomarkers have been described. An upper limit of a reference range might represent the most appropriate mechanism to utilize these data. These data can now be used to interpret data from exploratory clinical DILI studies and to assist their further qualification as required by regulatory authorities.

Jorgensen, Andrea L. [Department of Health Data Sc↗

A global analysis of soil microbial biomass carbon, nitrogen and phosphorus in terrestrial ecosystems

Soil microbes play a pivotal role in regulating land-atmosphere interactions; the soil microbial biomass carbon (C), nitrogen (N), phosphorus (P) and C:N:P stoichiometry are important regulators for soil biogeochemical processes; however, the current knowledge on magnitude, stoichiometry, storage, and spatial distribution of global soil microbial biomass C, N, and P is limited. In this study, 3087 pairs of data points were retrieved from 281 published papers and further used to summarize the magnitudes and stoichiometries of C, N, and P in soils and soil microbial biomass at global- and biome-levels. Finally, global stock and spatial distribution of microbial biomass C and N in 0-30 cm and 0-100 cm soil profiles were estimated. The results show that C, N, and P in soils and soil microbial biomass vary substantially across biomes; the fractions of soil nutrient C, N, and P in soil microbial biomass are 1.6% in a 95% confidence interval of (1.5%-1.6%), 2.9% in a 95% confidence interval of (2.8%-3.0%), and 4.4% in a 95% confidence interval of (3.9%-5.0%), respectively. The best estimates of C:N:P stoichiometries for soil nutrients and soil microbial biomass are 153:11:1, and 47:6:1, respectively, at global scale, and they vary in a wide range among biomes. Vertical distribution of soil microbial biomass follows the distribution of roots up to 1 m depth. The global stock of soil microbial biomass C and N were estimated to be 15.2 Pg C and 2.3 Pg N in the 0-30 cm soil profiles, and 21.2 Pg C and 3.2 Pg N in the 0-100 cm soil profiles. We did not estimate P in soil microbial biomass due to data shortage and insignificant correlation with soil total P and climate variables. The spatial patterns of soil microbial biomass C and N were consistent with those of soil organic C and total N, i.e. high density in northern high latitude, and low density in low latitudes and southern hemisphere.

Xu, Xiaofeng↗

Tungsten anode spectral model using interpolating cubic splines: Unfiltered x-ray spectra from 20 kV to 640 kV

Purpose: Monte Carlo methods were used to generate lightly filtered high resolution x-ray spectra spanning from 20 kV to 640 kV. Methods: X-ray spectra were simulated for a conventional tungsten anode. The Monte Carlo N-Particle eXtended radiation transport code (MCNPX 2.6.0) was used to produce 35 spectra over the tube potential range from 20 kV to 640 kV, and cubic spline interpolation procedures were used to create piecewise polynomials characterizing the photon fluence per energy bin as a function of x-ray tube potential. Using these basis spectra and the cubic spline interpolation, 621 spectra were generated at 1 kV intervals from 20 to 640 kV. The tungsten anode spectral model using interpolating cubic splines (TASMICS) produces minimally filtered (0.8 mm Be) x-ray spectra with 1 keV energy resolution. The TASMICS spectra were compared mathematically with other, previously reported spectra. Results: Using pairedt-test analyses, no statistically significant difference (i.e., p > 0.05) was observed between compared spectra over energy bins above 1% of peak bremsstrahlung fluence. For all energy bins, the correlation of determination (R{sup 2}) demonstrated good correlation for all spectral comparisons. The mean overall difference (MOD) and mean absolute difference (MAD) were computed over energy bins (above 1% of peak bremsstrahlung fluence) and over all the kV permutations compared. MOD and MAD comparisons with previously reported spectra were 2.7% and 9.7%, respectively (TASMIP), 0.1% and 12.0%, respectively [R. Birch and M. Marshall, “Computation of bremsstrahlung x-ray spectra and comparison with spectra measured with a Ge(Li) detector,” Phys. Med. Biol. 24, 505–517 (1979)], 0.4% and 8.1%, respectively (Poludniowski), and 0.4% and 8.1%, respectively (AAPM TG 195). The effective energy of TASMICS spectra with 2.5 mm of added Al filtration ranged from 17 keV (at 20 kV) to 138 keV (at 640 kV); with 0.2 mm of added Cu filtration the effective energy was 9 keV at 20 kV and 169 keV at 640 kV. Conclusions: Ranging from 20 kV to 640 kV, 621 x-ray spectra were produced and are available at 1 kV tube potential intervals. The spectra are tabulated at 1 keV intervals. TASMICS spectra were shown to be largely equivalent to published spectral models and are available in spreadsheet format for interested users by emailing the corresponding author (JMB)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-D-12A-01: An Inter-Projection Interpolation (IPI) Approach for the Synchronized Moving Grid (SMOG) to Reduce Dose in Cone Beam CT

Purpose: Synchronized moving grid is a promising technique to reduce scatter and ghost artifacts in cone beam computed tomography (CBCT). However, it requires 2 projections in the same gantry angle to obtain full information due to signal blockage by the grid. We proposed an inter-projection interpolation (IPI) method to estimate blocked signals, which may reduce the scan time and the dose. This study aims to provide a framework to achieve a balance between speed, dose and image quality. Methods: The IPI method is based on the hypothesis that an abrupt signal in a projection can be well predicted by the information in the two immediate neighboring projections if the gantry angle step is small. The study was performed on a Catphan and a head phantom. The SMOG was simulated by erasing the information (filling with “0”) of the areas in each projection corresponding to the grid. An IPI algorithm was applied on each projection to recover the erased information. FDK algorithm was used to reconstruct CBCT images for the IPI-processed projections, and compared with the original image in term of signal to noise ratio (SNR) measured in the whole reconstruction image range. The effect of gantry angle step was investigated by comparing the CBCT images from projection sets of various gantry intervals, with IPI-predicted projections to fill the missing projection in the interval. Results: The IPI procession time was 1.79s±0.53s for each projection. SNR after IPI was 29.0db and 28.1db for the Catphan and head phantom, respectively, comparing to 15.3db and 22.7db for an inpainting based interpolation technique. SNR was 28.3, 28.3, 21.8, 19.3 and 17.3 db for gantry angle intervals of 1, 1.5, 2, 2.5 and 3 degrees, respectively. Conclusion: IPI is feasible to estimate the missing information, and achieve an reasonable CBCT image quality with reduced dose and scan time. This study is supported by NIH/NCI grant 1R01CA166948-01.

60 APPLIED LIFE SCIENCES↗

SU-E-T-101: An Arc Based Treatment Technique for Proton PBS Beam Utilizing Overlaid Bragg Peak Spots

Purpose: When Bragg peaks from proton PBS beams are overlaid from a large number of directions, it creates a localized dose distribution with rapid falloff. By positioning these overlaid Bragg peak (OBP) spots strategically throughout the targeted volume, a uniform and conformal dose distribution can be achieved. When PBS spots from all the directions are delivered in an arc fashion, it becomes the Volume Modulated Proton Therapy (VMPT) technique which corresponds to the VMAT technique in photon therapy. Methods: PBS beam from an IBA machine and a 20cm radius cylindrical phantom were simulated with GATE/GEANT4. To position the OBP spot at the center of the phantom, single energy PBS beam from 10/36/360 equally-spaced directions around the phantom was used. To position the OBP spot at an off-center position, PBS beams with various energies were used. To form a uniform dose distribution in 1D/2D, OBP spots are positioned in arrays with spot intervals and weight optimized. Results: Dose profile for single energy OBP spot improved when the number of beam angles increased from 10 to 36, but remained same from 36 to 360 angles. Multi-energy OBP spot had a slightly non-symmetrical profile due to the different energy proton beams used. By optimizing each OBP spot’s weight, 11 OBP spots with 10mm interval size created a uniform dose distribution covering a length of 10cm. Similarly, 11×11 OBP spots in an array of 10mm interval size created a uniform dose distribution covering an area of 10×10cm{sup 2}. Conclusion: We demonstrated the technique of using OBP spots to deliver uniform dose in 1D/2D. This technique can be easily extended through the optimization of position and weight of OBP spots in 3D and becomes the arc based VMPT technique. Further studies are needed to explore the optimization methods and full potential of the VMPT technique.

60 APPLIED LIFE SCIENCES↗

SU-E-T-747: The Use of the EQD2 Formalism and Repair Estimates in the Re-Irradiation Setting and Correlation with Patient Follow-Up Data

Purpose: Medical advances have resulted in cancer patients living longer as evidenced by the number of patients seen for possible re-irradiation. Original normal tissue dose volume constraints remain in the re-irradiation setting to minimize normal tissue toxicity. This work correlates estimates of equivalent dose and repair with sequelae. Methods: CNS and GI tract re-irradiation patient follow-up records (including imaging studies) were reviewed with side effects correlated with the calculated EQD2 and repair estimates. Results: Follow-up records for 16 re-irradiation patients with potential overlap to the spinal cord were analyzed. The mean time interval between 1st and last courses was 76.6 months. Three patients underwent a 3rd course of radiotherapy with a mean time interval between 2nd and final courses of 19.7 months. The mean values for assumed repair were 18.8% and 8.3%, respectively. The calculated total EQD2 doses were 48.09Gy and 50.98Gy with and without repair. At a mean follow-up time of 5.0 months, 6 patients were deceased and no records indicate radiation related neurological deficits. The records for 11 patients with potential overlap to the bowel were also analyzed. The mean time interval between 1st and last courses was 105.9 months. The mean value for assumed repair was 15.9%. The calculated total EQD2 doses were 64.96Gy and 70.80Gy with and without repair. At a mean follow-up time of 4.9 months, 6 patients were deceased, one having a potential enteric fistulization of the bladder. Clinical review of the case determined that the fistula was caused by tumor progression and not a side effect of radiotherapy treatments. Conclusion: Application of the EQD2 method in the re-irradiation setting using conservative estimates of repair is presented. Adhering to accepted dose volume limits following this application is demonstrated to be safe through empirical records as limited by this small patient cohort and short follow-up.

60 APPLIED LIFE SCIENCES↗

WE-H-BRC-09: Simulated Errors in Mock Radiotherapy Plans to Quantify the Effectiveness of the Physics Plan Review

Purpose: A standard tool for ensuring the quality of radiation therapy treatments is the initial physics plan review. However, little is known about its performance in practice. The goal of this study is to measure the effectiveness of physics plan review by introducing simulated errors into “mock” treatment plans and measuring the performance of plan review by physicists. Methods: We generated six mock treatment plans containing multiple errors. These errors were based on incident learning system data both within the department and internationally (SAFRON). These errors were scored for severity and frequency. Those with the highest scores were included in the simulations (13 errors total). Observer bias was minimized using a multiple co-correlated distractor approach. Eight physicists reviewed these plans for errors, with each physicist reviewing, on average, 3/6 plans. The confidence interval for the proportion of errors detected was computed using the Wilson score interval. Results: Simulated errors were detected in 65% of reviews [51–75%] (95% confidence interval [CI] in brackets). The following error scenarios had the highest detection rates: incorrect isocenter in DRRs/CBCT (91% [73–98%]) and a planned dose different from the prescribed dose (100% [61–100%]). Errors with low detection rates involved incorrect field parameters in record and verify system (38%, [18–61%]) and incorrect isocenter localization in planning system (29% [8–64%]). Though pre-treatment QA failure was reliably identified (100%), less than 20% of participants reported the error that caused the failure. Conclusion: This is one of the first quantitative studies of error detection. Although physics plan review is a key safety measure and can identify some errors with high fidelity, others errors are more challenging to detect. This data will guide future work on standardization and automation. Creating new checks or improving existing ones (i.e., via automation) will help in detecting those errors with low detection rates.

60 APPLIED LIFE SCIENCES↗

Using machine learning to predict antimicrobial MICs and associated genomic features for nontyphoidal Salmonella

Nontyphoidal Salmonella species are the leading bacterial cause of food-borne disease in the United States. Whole genome sequences and paired antimicrobial susceptibility data are available for Salmonella strains because of surveillance efforts from public health agencies. In this study, a collection of 5,278 nontyphoidal Salmonella genomes, collected over 15 years in the United States, were used to generate XGBoost-based machine learning models for predicting minimum inhibitory concentrations (MICs) for 15 antibiotics. The MIC prediction models have an overall average accuracy of 95% within ± 1 two-fold dilution step (confidence interval of 95-95%), an average very major error rate of 2.7% (confidence interval of 2.4-3.0%) and an average major error rate of 0.1% (confidence interval of 0.1-0.2%). The model predicts MICs with no a priori information about the underlying gene content or resistance phenotypes of the strains. By selecting diverse genomes for training sets, we show that highly accurate MIC prediction models can be generated with fewer than 500 genomes. We also show that our approach for predicting MICs is stable over time despite annual fluctuations in antimicrobial resistance gene content in the sampled genomes. Finally, using feature selection, we explore the important genomic regions identified by the models for predicting MICs. To date, this is one of the largest MIC modeling studies to be published. Furthermore, our strategy for developing whole genome sequence-based models for surveillance and clinical diagnostics can be readily applied to other important human pathogens.

59 BASIC BIOLOGICAL SCIENCES↗

Selection of Spectral Variables and Improvement of the Accuracy of Calibration of Temperature by Projection onto Latent Structures Using the Fluorescence Spectra of Yb{sup 3+}:CaF{sub 2}

The efficiency of interval methods for selecting variables and the divisive method of interval optimization by a genetic algorithm is considered with the purpose to increase the accuracy of temperature calibration by projection onto latent structures. The fluorescence spectra of Yb{sup 3+}:CaF{sub 2} recorded in the 880–1120 nm band with a resolution of approximately 0.2 nm in the temperature range from 66 to 150°C in 2°C increments are used as an example. The best result for the root-mean-square error of temperature prediction in the test sample (0.45°C) was obtained by interval projection onto latent structures by a combination of moving windows. The use of methods for selecting spectral variables improved more than two times the accuracy of temperature calibration.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Phase transitions in a two-dimensional antiferromagnetic Potts model on a triangular lattice with next-nearest neighbor interactions

Phase transitions (PTs) and frustrations in two-dimensional structures described by a three-vertex antiferromagnetic Potts model on a triangular lattice are investigated by the Monte Carlo method with regard to nearest and next-nearest neighbors with interaction constants J{sub 1} and J{sub 2}, respectively. PTs in these models are analyzed for the ratio r = J{sub 2}/J{sub 1} of next-nearest to nearest exchange interaction constants in the interval |r| = 0–1.0. On the basis of the analysis of the low-temperature entropy, the density of states function of the system, and the fourth-order Binder cumulants, it is shown that a Potts model with interaction constants J{sub 1} < 0 and J{sub 2} < 0 exhibits a first-order PT in the range of 0 ⩽ r < 0.2, whereas, in the interval 0.2 ⩽ r ⩽ 1.0, frustrations arise in the system. At the same time, for J{sub 1} > 0 and J{sub 2} < 0, frustrations arise in the range 0.5 < |r| < 1.0, while, in the interval 0 ⩽ |r| ⩽ 1/3, the model exhibits a second-order PT.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Stable branches of a solution for a fermion on domain wall

The case when a fermion occupies an excited nonzero frequency level in the field of domain wall is discussed. It is demonstrated that a solution exists for the coupling constant in the limited interval 1 < g < g{sub max} Almost-Equal-To 1.65. It is shown that indeed there are different branches of stable solution for g in this interval. The first one corresponds to a fermion located on the domain wall (1 < g < 4{radical}2{pi}). The second branch, which belongs to the interval 4{radical}2{pi} {<=} g {<=} g{sub max}, describes a polarized fermion off the domain wall. The third branch with 1 < g < g{sub max} describes an excited antifermion in the field of the domain wall.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of $t\bar{t}$ production with a veto on additional central jet activity in pp collisions at $\sqrt{s}=7$ TeV using the ATLAS detector

A measurement of the jet activity in $t\bar{t}$ events produced in proton–proton collisions at a centre-of-mass energy of 7 TeV is presented, using 2.05 fb -1 of integrated luminosity collected by the ATLAS detector at the Large Hadron Collider. The $t\bar{t}$ events are selected in the dilepton decay channel with two identified b-jets from the top quark decays. Events are vetoed if they contain an additional jet with transverse momentum above a threshold in a central rapidity interval. The fraction of events surviving the jet veto is presented as a function of this threshold for four different central rapidity interval definitions. An alternate measurement is also performed, in which events are vetoed if the scalar transverse momentum sum of the additional jets in each rapidity interval is above a threshold. In both measurements, the data are corrected for detector effects and compared to the theoretical models implemented in MC@NLO, Powheg, Alpgen and Sherpa. The experimental uncertainties are often smaller than the spread of theoretical predictions, allowing deviations between data and theory to be observed in some regions of phase space.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗