Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interferometric”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Automatic null ellipsometry with an interferometer

A new approach to automatic null ellipsometry is described in which the analyzer of a traditional polarizer compensator sample analyzer (PCSA) null ellipsometer is replaced with a heterodyne Michelson interferometer. One arm of this interferometer is modified such that it produces a fixed, linearly polarized reference beam, irrespective of the input polarization state. This beam is recombined interferometrically with the measurement beam and spatially separated into its p and s polarizations. The relative phase of the resulting temporal fringes is a linear function of the polarizer azimuthal angle P, and thus this component can be driven to its null position without iteration. Once at null, the azimuthal angle of the reflected, linearly polarized light is trivially determined from the relative amplitude of the fringes. Measurements made with this instrument on a native oxide film on a silicon wafer were in excellent agreement with those made with a traditional PCSA null ellipsometer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Shot-noise-limited control-loop noise in an interferometer with multiple degrees of freedom

Precise measurements, such as those made with interferometric gravitational-wave detectors, require the measurement device to be properly controlled so that the sensitivity can be as high as possible. Mirrors in the interferometer are to be located at specific operation points to isolate laser noise and to accumulate the signal in resonant cavities. On the other hand, rigid control of an auxiliary degree of freedom may result in imposing sensing noise of the control on the target object as excess force noise. Evaluation of this so-called loop noise is important in order to design a decent control scheme of the measurement device. In this paper, we show the method to calculate the level of loop noise, which has been recently implemented in simulation tools that are broadly used for designing gravitational-wave detectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical heterodyne accelerometry: passively stabilized, fully balanced velocity interferometer system for any reflector

We formalize the physics of an optical heterodyne accelerometer that allows measurement of low and high velocities from material surfaces under high strain. The proposed apparatus incorporates currently common optical velocimetry techniques used in shock physics, with interferometric techniques developed to self-stabilize and passively balance interferometers in quantum cryptography. The result is a robust telecom-fiber-based velocimetry system insensitive to modal and frequency dispersion that should work well in the presence of decoherent scattering processes, such as from ejecta clouds and shocked surfaces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fourier analysis for hydrostatic pressure sensing in a polarization-maintaining photonic crystal fiber

.We measured the hydrostatic pressure dependence of the birefringence and birefringent dispersion of a Sagnac interferometric sensor incorporating a length of highly birefringent photonic crystal fiber using Fourier analysis. Sensitivity of both the phase and chirp spectra to hydrostatic pressure is demonstrated. Using this analysis, phase-based measurements showed a good linearity with an effective sensitivity of 9.45nm/MPa and an accuracy of {+-}7.8kPa using wavelength-encoded data and an effective sensitivity of -55.7cm{sup -1}/MPa and an accuracy of {+-}4.4kPa using wavenumber-encoded data. Chirp-based measurements, though nonlinear in response, showed an improvement in accuracy at certain pressure ranges with an accuracy of {+-}5.5kPa for the full range of measured pressures using wavelength-encoded data and dropping to within {+-}2.5kPa in the range of 0.17 to 0.4MPa using wavenumber-encoded data. Improvements of the accuracy demonstrated the usefulness of implementing chirp-based analysis for sensing purposes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Heterodyne grating interferometer based on a quasi-common-optical-path configuration for a two-degrees-of-freedom straightness measurement

We present a heterodyne grating interferometer based on a quasi-common-optical-path (QCOP) design for a two-degrees-of-freedom (DOF) straightness measurement. Two half-wave plates are utilized to rotate the polarizations of two orthogonally polarized beams. The grating movement can be calculated by measuring the phase difference variation in each axis. The experimental results demonstrate that our method has the ability to measure two-DOF straightness and still maintain high system stability. The proposed and demonstrated method, which relies on heterodyne interferometric phase measurement combined with the QCOP configuration, has the advantages of high measurement resolution, relatively straightforward operation, and high system stability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity enhancement of grating interferometer based two-dimensional sensor arrays using two-wavelength readout

Diffraction gratings integrated with microelectromechanical systems (MEMS) sensors offer displacement measurements with subnanometer sensitivity. However, the sensitivity of the interferometric readout may drop significantly based on the gap between the grating and the reference surface. A two-wavelength (2-{lambda}) readout method was previously tested using a single MEMS sensor for illustrating increased displacement measurement capability. This work demonstrates sensitivity enhancement on a sensor array with large scale parallelization ({approx}20,000 sensors). The statistical representation, which is developed to model sensitivity enhancement within a grating based sensor array, is supported by experimental results using a thermal sensor array. In the experiments, two lasers at different wavelengths (633 and 650 nm) illuminate the thermal sensor array from the backside, time-sequentially. The diffracted first order light from the array is imaged onto a single CCD camera. The target scene is reconstructed by observing the change in the first diffracted order diffraction intensity for both wavelengths. Merging of the data from two measurements with two lasers was performed by taking the larger of the two CCD measurements with respect to the reference image for each sensor. {approx}30% increase in the average sensitivity was demonstrated for a 160x120 pixel IR sensor array. Proposed architecture is also applicable to a variety of sensing applications, such as parallel biosensing and atomic force microscopy, for improved displacement measurements and enhanced sensitivity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-precision diode-laser-based temperature measurement for air refractive index compensation

We present a laser-based system to measure the refractive index of air over a long path length. In optical distance measurements, it is essential to know the refractive index of air with high accuracy. Commonly, the refractive index of air is calculated from the properties of the ambient air using either Ciddor or Edlen equations, where the dominant uncertainty component is in most cases the air temperature. The method developed in this work utilizes direct absorption spectroscopy of oxygen to measure the average temperature of air and of water vapor to measure relative humidity. The method allows measurement of temperature and humidity over the same beam path as in optical distance measurement, providing spatially well-matching data. Indoor and outdoor measurements demonstrate the effectiveness of the method. In particular, we demonstrate an effective compensation of the refractive index of air in an interferometric length measurement at a time-variant and spatially nonhomogeneous temperature over a long time period. Further, we were able to demonstrate 7 mK RMS noise over a 67 m path length using a 120 s sample time. To our knowledge, this is the best temperature precision reported for a spectroscopic temperature measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of the surface profile of an axicon lens with a polarization phase-shifting shearing interferometer

We present a Twyman-Green interferometer (TGI)-based polarization phase-shifting shearing interferometric technique for testing the conical surface of an axicon (AX) lens. In this technique, the annular beam generated due to the passing of an expanded collimated laser beam traveling along the axis of revolution of the transparent glass AX element is split up into its reflected and transmitted components, having the plane of polarization in the orthogonal planes, by the polarization beam splitter (PBS) cube of the TGI-based optical setup. The split-up components are made to travel unequal paths along the two arms of the TGI and are recombined by the PBS. Because of the difference in path lengths traveled by the annular conical beams, a linear shear is introduced along the radial direction between the interfering components. Thus, the resulting interference pattern gives a map of the optical path difference (OPD) between two successive close points along a radial direction on the conical surface of the AX lens. The OPD map along radial directions, and hence the slopes/profiles of the conical surface, are obtained by applying polarization phase-shifting interferometry. Results obtained for an AX lens are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of laser-driven shock waves in solids using a fiber optic pressure probe

Measurement of laser-driven shock wave pressure in solid blocks of polymethyl methacrylate is demonstrated using fiber optic pressure probes. Three probes based on a fiber Fabry–Perot, fiber Bragg grating, and interferometric fiber tip sensor are tested and compared. Shock waves are generated using a high-power laser focused onto a thin foil target placed in close proximity to the test blocks. The fiber Fabry–Perot sensor appears capable of resolving the shock front with a rise time of 91 ns. As a result, the peak pressure is estimated, using a separate shadowgraphy measurement, to be 3.4 GPa.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Talbot–Lau x-ray deflectometry phase-retrieval methods for electron density diagnostics in high-energy density experiments

Talbot–Lau x-ray interferometry uses incoherent x-ray sources to measure refraction index changes in matter. These measurements can provide accurate electron density mapping through phase retrieval. An adaptation of the interferometer has been developed in order to meet the specific requirements of high-energy density experiments. This adaptation is known as a moiré deflectometer, which allows for single-shot capabilities in the form of interferometric fringe patterns. The moiré x-ray deflectometry technique requires a set of object and reference images in order to provide electron density maps, which can be costly in the high-energy density environment. In particular, synthetic reference phase images obtained ex situ through a phase-scan procedure, can provide a feasible solution. To test this procedure, an object phasemap was retrieved from a single-shot moiré image obtained from a plasma-produced x-ray source. A reference phase map was then obtained from phase-stepping measurements using a continuous x-ray tube source in a small laboratory setting. Ultimately, the two phase maps were used to retrieve an electron density map. A comparison of the moiré and phase-stepping phase-retrieval methods was performed to evaluate single-exposure plasma electron density mapping for high-energy density and other transient plasma experiments. It was found that a combination of phase-retrieval methods can deliver accurate refraction angle mapping. Once x-ray backlighter quality is optimized, the ex situ method is expected to deliver electron density mapping with improved resolution. The steps necessary for improved diagnostic performance are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Broadband infrared vibrational nano-spectroscopy using thermal blackbody radiation

Infrared vibrational nano-spectroscopy based on scattering scanning near-field optical microscopy (s-SNOM) provides intrinsic chemical specificity with nanometer spatial resolution. Here we use incoherent infrared radiation from a 1400 K thermal blackbody emitter for broadband infrared (IR) nano-spectroscopy.With optimized interferometric heterodyne signal amplification we achieve few-monolayer sensitivity in phonon polariton spectroscopy and attomolar molecular vibrational spectroscopy. Near-field localization and nanoscale spatial resolution is demonstrated in imaging flakes of hexagonal boron nitride (hBN) and determination of its phonon polariton dispersion relation. The signal-to-noise ratio calculations and analysis for different samples and illumination sources provide a reference for irradiance requirements and the attainable near-field signal levels in s-SNOM in general. As a result, the use of a thermal emitter as an IR source thus opens s-SNOM for routine chemical FTIR nano-spectroscopy.

36 MATERIALS SCIENCE↗

Self referencing attosecond interferometer with zeptosecond precision

In this work we demonstrate the generation of two intense, ultrafast laser pulses that allow a controlled interferometric measurement of higher harmonic generation pulses with 12.8 attoseconds in resolution (half the atomic unit of time) and a precision as low as 680 zeptoseconds (10–21 seconds). We create two replicas of a driving femtosecond pulse which share the same optical path except at the focus where they converge to two foci. An attosecond pulse train emerges from each focus through the process of high harmonic generation. The two attosecond pulse trains from each focus interfere in the far field producing a clear interference pattern in the extreme ultraviolet region. By controlling the relative optical phase (carrier envelope phase for pulsed fields) between the two driving laser pulses we are able to actively influence the delay between the pulses and are able to perform very stable and precise pump-probe experiments. Because of the phase shaping operation occurs homogeneously across the entire spatial profile, we effectively create two indistinguishable intense laser pulses or a common path interferometer for attosecond pulses. Commonality across the two beams means that they are extremely stable to environmental and mechanical fluctuations up to a Rayleigh range from the focus. In our opinion this represents an ideal source for homodyne and heterodyne spectroscopic measurements with sub-attosecond precision.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Two-dimensional stitching interferometry for self-calibration of high-order additive systematic errors

Stitching interferometry is performed by collecting interferometric data from overlapped sub-apertures and stitching these data together to provide a full surface map. The propagation of the systematic error in the measured subset data is one of the main error sources in stitching interferometry for accurate reconstruction of the surface topography. In this work, we propose, using the redundancy of the captured subset data, two types of two-dimensional (2D) self-calibration stitching algorithms to overcome this issue by in situ estimating the repeatable high-order additive systematic errors, especially for the application of measuring X-ray mirrors. The first algorithm, called CS short for “Calibrate, and then Stitch”, calibrates the high-order terms of the reference by minimizing the de-tilted discrepancies of the overlapped subsets and then stitches the reference-subtracted subsets. The second algorithm, called SC short for “Stitch, and then Calibrate”, stitches a temporarily result and then calibrates the reference from the de-tilted discrepancies of the measured subsets and the temporarily stitched result. In the implementation of 2D scans in $x$- and y -directions, step randomization is introduced to generate nonuniformly spaced subsets which can diminish the periodic stitching errors commonly observed in evenly spaced subsets. The regularization on low-order terms enables a highly flexible option to add the curvature and twist acquired by another system. Both numerical simulations and experiments are carried out to verify the proposed method. All the results indicate that 2D high-order repeatable additive systematic errors can be retrieved from the 2D redundant overlapped data in stitching interferometry.

42 ENGINEERING↗

Visible (400- to 700-nm) chirped-grating-coupled waveguide spectrometer

An integrable on-chip spectrometer, based on a transversely-chirped-grating waveguide-coupler for the 400- to 700-nm visible spectral range is demonstrated. For a fixed angle of incidence, the coupling wavelength is dependent on the local grating period and the waveguide structure. The transversely-chirped-input grating is fabricated on a SiO 2 -Si 3 N 4 -SiO 2 waveguide atop a Si substrate by interferometric lithography in two sections on a single silicon substrate. A uniform period grating, separated from the input coupler by a propagation region, is provided for out-coupling to a 2048 element CMOS detector array. The incident light with wavelength spanning 400- to 700-nm is coupled into waveguide at 33.5° through the chirped grating coupler. A resolution of ∼ 1.2 nm is demonstrated without any signal processing reconstruction.

Wang, Xuemei↗

Towards quantum telescopes: demonstration of a two-photon interferometer for precision astrometry

Classical optical interferometry requires maintaining live, phase-stable links between telescope stations. This requirement greatly adds to the cost of extending to long baseline separations and limits on baselines will in turn limit the achievable angular resolution. Here we describe a novel type of two-photon interferometer for astrometry, which uses photons from two separate sky sources and does not require an optical link between stations. Such techniques may make large increases in interferometric baselines practical, even by orders of magnitude, with a corresponding improvement in astrometric precision benefiting numerous fields in astrophysics. We tested a benchtop analogue version of the two-source interferometer and unambiguously observe correlated behavior in detections of photon pairs from two thermal light sources, in agreement with theoretical predictions. This work opens new possibilities in future astronomical measurements.

47 OTHER INSTRUMENTATION↗

Broadband rapid-scanning phase-modulated Fourier transform electronic spectroscopy

We present a phase-modulated approach for ultrabroadband Fourier transform electronic spectroscopy. To overcome the bandwidth limitations and spatial chirp introduced by acousto-optic modulators (AOMs), pulses from a 1 µm laser are modulated using AOMs prior to continuum generation. This phase modulation is transferred to the continuum generated in a yttrium aluminum garnet crystal. Separately generated phase-modulated continua in two arms of a Mach-Zehnder interferometer interfere with the difference of their modulation frequencies, enabling physical under-sampling of the signal and the suppression of low-frequency noise. By interferometrically tracking the relative time delay of the continua, we perform continuous, rapid-scanning Fourier transform electronic spectroscopy with a high signal-to-noise ratio and spectral resolution. As proof of principle, we measure the linear absorption and fluorescence excitation spectra of a laser dye and various biological samples.

Javed, Ariba↗

Naturally stable Sagnac–Michelson nonlinear interferometer

Interferometers measure a wide variety of dynamic processes by converting a phase change into an intensity change. Nonlinear interferometers, making use of nonlinear media in lieu of beamsplitters, promise substantial improvement in the quest to reach the ultimate sensitivity limits. Here we demonstrate a new nonlinear interferometer utilizing a single parametric amplifier for mode mixing conceptually, a nonlinear version of the conventional Michelson interferometer with its arms collapsed together. We observe up to 99.9% interference visibility and find evidence for noise reduction based on phase-sensitive gain. As a result, our configuration utilizes fewer components than previous demonstrations and requires no active stabilization, offering new capabilities for practical nonlinear interferometric-based sensors.

47 OTHER INSTRUMENTATION↗

Spectral interferometry-based microwave-frequency vibrometry for integrated acoustic wave devices

Microwave phononics is a promising platform for sensing, computing, and quantum information science; thus, sensitive and high-throughput characterization tools are needed not only for device verification and optimization but also for revealing transient and nonlinear dynamics. Existing interferometric optical vibrometers for 2D mapping are challenged by operating point stabilization, surface reflectivity contrast, and long acquisition time. Here, we use spectral interferometry, which is insensitive to these factors and utilizes a continuous raster scanning scheme for vibration mapping with high throughput. We intensity-modulate our broadband light source with an electro-optic modulator to resolve vibrations at microwave frequencies. Our system requires no fast photodetector or digitizer operating in the microwave frequency range. We image the 1 GHz vibration field of a 300 × 150 µm 2 area of an entire surface acoustic wave device in 10 min with simultaneous surface profilometry. Our system has a vibration sensitivity of 120 fm/sqrt(Hz) and a linear throughput of 0.77 mm/s on the chip surface. The technique offers capabilities for characterizing a wide range of acoustic wave and micromechanical devices to better understand their behavior and performance.

47 OTHER INSTRUMENTATION↗