Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Piezoelectric Shaker Development for High Frequency Calibration of Accelerometers

Calibration of vibration transducers requires sinusoidal motion over a wide frequency range with low distortion and low cross-axial motion. Piezoelectric shakers are well suited to generate such motion and are suitable for use with laser interferometric methods at frequencies of 3 kHz and above. An advantage of piezoelectric shakers is the higher achievable accelerations and displacement amplitudes as compared to electro-dynamic (ED) shakers. Typical commercial ED calibration shakers produce maximum accelerations from 100 m/s{sup 2} to 500 m/s{sup 2}. Very large ED shakers may produce somewhat higher accelerations but require large amplifiers and expensive cooling systems to dissipate heat. Due to the limitations in maximum accelerations by ED shakers at frequencies above 5 kHz, the amplitudes of the generated sinusoidal displacement are frequently below the resolution of laser interferometers used in primary calibration methods. This limits the usefulness of ED shakers in interferometric based calibrations at higher frequencies.Small piezoelectric shakers provide much higher acceleration and displacement amplitudes for frequencies above 5 kHz, making these shakers very useful for accelerometer calibrations employing laser interferometric measurements, as will be shown in this paper. These piezoelectric shakers have been developed and used at NIST for many years for high frequency calibration of accelerometers. This paper documents the construction and performance of a new version of these shakers developed at NIST for the calibration of accelerometers over the range of 3 kHz to 30 kHz and possibly higher. Examples of typical calibration results are also given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of Calibrating Force Transducer Using Sinusoidal Force

Sinusoidal force calibration method was studied several years before at Physikalisch-Technische Bundesanstalt (PTB). A similar dynamic force calibration system is developed at Changcheng Institute of Metrology and Measurement (CIMM). It uses electro-dynamic shakers to generate dynamic force in the range from 1 N to 20 kN, and heterodyne laser interferometers are used for acceleration measurement. The force transducer to be calibrated is mounted on the shaker, and a mass block is screwed on the top of force transducer, the sinusoidal forces realized by accelerated load masses are traceable to acceleration and mass according to the force definition. The methods of determining Spatial-dependent acceleration on mass block and measuring the end mass of force transducer in dynamic force calibration are discussed in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the Support and Drive System of the PETRA III APPLE Undulator

Helmholtzzentrum Berlin has built an APPLE II undulator for the storage ring PETRA III. The device has a total length of 5m and a minimum gap of 11mm. The high magnetic forces in particular in the inclined mode have been analyzed by means of finite element methods (FEM). Specific mechanic components such as flexible joints have been optimized to cope with the gap- and shift-dependent 3D-forces and a sophisticated control and drive system has been implemented. After completion of the device, detailed laser interferometer measurements for all operation modes have been performed. The data are compared to the FEM simulations.

43 PARTICLE ACCELERATORS↗

Visible Light Diagnostics at SPEAR3

The visible light diagnostic beam line at SPEAR3 utilizes dipole radiation extracted through an ID exit port to evaluate electron beam properties at a variety of diagnostic end-stations. The unfocused SR light is collected 17 m from the source point by a 150 mm diameter, f = 2 m lens and optically relayed to the appropriate station. For transverse imaging, an image-intensified PiMax camera with 2 ns gate allows measurement of fast beam dynamics for either the stored beam or the injected beam. For these applications the visible light is switched into either a standard symmetric-lens transport line or a beam-shaping transport line equipped with cylindrical lenses and a rotating mirror to sweep the beam image across the camera photocathode. A separate two slit stellar-interferometer branch line can resolve the diffraction-limited vertical beam height down to about 10 {mu}m. For longitudinal charge profile measurements, the light is switched to a Hamamatsu C5680 streak camera with net system resolution of {approx}2.5 ps rms. In this paper we outline the main photon beam transport line, review the SR beam properties and describe measurement capabilities at each diagnostic station.

43 PARTICLE ACCELERATORS↗

Area-selected Ion Milling for Reflection Wavefront Error Correction of Soft X-ray Multilayer Mirrors

For accurate reflection wavefront error correction of imaging soft X-ray multilayer mirrors, a period-by-period ion milling system was developed. A stable and homogenized radial distribution of ion beam was realized for an ion milling over a whole area of 100 mm-wide multilayer. To demonstrate the wavefront error correction principle, a dielectric multilayer mirror for visible light was locally milled by our system. Wavefront as measured by a phase shifting interferometer showed the reflection phase of local milling multilayer advanced. Area-selected ion millings with mask templates made of Mo and Si, and by photoresist contact masks were carried out. Although striped patterns generated by the difference of spectroscopic reflectance between Mo and Si were observed at peripherals of milling area when templates were used, a clear and sharp edge pattern was obtained with contact mask. Soft X-ray reflectance of a Mo/Si multilayer milled with photoresist contact mask showed good feasibility of precise wavefront error correction of multilayers. These results proved our phase correction method is promising and practical for the 0.1 nm-period correction of soft X-ray multilayer mirror.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Far-forward collective scattering measurements of density fluctuations in the helically symmetric experiment stellarator

The multichannel interferometer system on the helically symmetric experiment (HSX) stellarator is reconfigured to perform far-forward collective scattering measurements of electron density fluctuations. The collective scattering system has nine viewing chords with 1.5 cm spacing. Scattered power is measured using a homodyne detection scheme. Far-forward collective scattering provides a line-integrated measurement of fluctuations within the divergence of the probe beam covering wavenumber range: k{sub perpendicular}<2 cm{sup -1}. The perpendicular wavenumber consists of poloidal and radial contributions that vary with chord position. Both coherent modes and broadband fluctuation are measured. When HSX is operated without quasihelical symmetry at B{sub T}=1 T and n{sub e}{approx}4x10{sup 12} cm{sup -3}, a coherent electrostatic fluctuation is observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two dimensional density and its fluctuation measurements by using phase imaging method in GAMMA 10

Two dimensional (2D) plasma image analysis is useful to study the improvement of plasma confinement in magnetically confined fusion plasmas. We have constructed a 2D interferometer system with phase imaging method for studying 2D plasma density distribution and its fluctuation measurement in the tandem mirror GAMMA 10. 2D profiles of electron density and its fluctuation have been successfully obtained by using this 2D phase imaging system. We show that 2D plasma density and fluctuation profiles clearly depends on the axial confining potential formation with application of plug electron cyclotron heating in GAMMA 10.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Noise analysis of grating-based x-ray differential phase contrast imaging

The sensitivity of x-ray radiographic images, meaning the minimal detectable change in the thickness or in the index of refraction of a sample, is directly related to the uncertainty of the measurement method. In the following work, we report on the recent development of quantitative descriptions for the stochastic error of grating-based differential phase contrast imaging (DPCi). Our model includes the noise transfer characteristics of the x-ray detector and the jitter of the phase steps. We find that the noise in DPCi depends strongly on the phase stepping visibility and the sample properties. The results are supported by experimental evidence acquired with our new instrument with a field of view of 50x70 mm{sup 2}. Our conclusions provide general guidelines to optimize grating interferometers for specific applications and problems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Faraday rotation data analysis with least-squares elliptical fitting

A method of analyzing Faraday rotation data from pulsed magnetic field measurements is described. The method uses direct least-squares elliptical fitting to measured data. The least-squares fit conic parameters are used to rotate, translate, and rescale the measured data. Interpretation of the transformed data provides improved accuracy and time-resolution characteristics compared with many existing methods of analyzing Faraday rotation data. The method is especially useful when linear birefringence is present at the input or output of the sensing medium, or when the relative angle of the polarizers used in analysis is not aligned with precision; under these circumstances the method is shown to return the analytically correct input signal. The method may be pertinent to other applications where analysis of Lissajous figures is required, such as the velocity interferometer system for any reflector (VISAR) diagnostics. The entire algorithm is fully automated and requires no user interaction. An example of algorithm execution is shown, using data from a fiber-based Faraday rotation sensor on a capacitive discharge experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of line integrated electron density using plasma position data on Korea Superconducting Tokamak Advanced Research

A 280 GHz single-channel horizontal millimeter-wave interferometer system has been installed for plasma electron density measurements on the Korea Superconducting Tokamak Advanced Research (KSTAR) device. This system has a triangular beam path that does not pass through the plasma axis due to geometrical constraints in the superconducting tokamak. The term line density on KSTAR has a different meaning from the line density of other tokamaks. To estimate the peak density and the mean density from the measured line density, information on the position of the plasma is needed. The information has been calculated from tangentially viewed visible images using the toroidal symmetry of the plasma. Interface definition language routines have been developed for this purpose. The calculated plasma position data correspond well to calculation results from magnetic analysis. With the position data and an estimated plasma profile, the peak density and the mean density have been obtained from the line density. From these results, changes of plasma density themselves can be separated from effects of the plasma movements, so they can give valuable information on the plasma status.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tomographic Hard X-ray Phase Contrast Micro- and Nano-imaging at TOMCAT

This article illustrates the phase contrast instrumentation installed at the Tomographic Microscopy and Coherent Radiology beamline (TOMCAT) of the Swiss Light Source. Our experimental framework has been designed to extract phase information at spatial resolutions covering three orders of magnitude. For moderate (5-10 microns) resolutions we implemented a two-gratings interferometer, operated at energies between 14 and 40 keV. For high resolution (1-5 microns) we obtain phase information thanks to a modified transport of intensity approach. For very high-resolutions (0.1-0.5 microns) we developed a broadband hard X-ray full-field microscope operated in Zernike-phase contrast.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of a linear device developed for research on advanced plasma imaging and dynamics

Within the scope of long term research on imaging diagnostics for steady-state plasmas and understanding of edge plasma physics through diagnostics with conventional spectroscopic methods, we have constructed a linear electron cyclotron resonance (ECR) plasma device named Research on Advanced Plasma Imaging and Dynamics (RAPID). It has a variety of axial magnetic field profiles provided by eight water-cooled magnetic coils and two dc power supplies. The positions of the magnetic coils are freely adjustable along the axial direction and the power supplies can be operated with many combinations of electrical wiring to the coils. Here, a 6 kW 2.45 GHz magnetron is used to produce steady-state hydrogen, helium, and argon plasmas with central magnetic fields of 875 and/or 437.5 G (second harmonic). In order to achieve the highest possible plasma performance within the limited input parameters, wall conditioning experiments were carried out. Chamber bake-out was achieved with heating coils that were wound covering the vessel, and long-pulse electron cyclotron heating discharge cleaning was also followed after 4 days of bake-out. A uniform bake-out temperature (150 deg. C) was achieved by wrapping the vessel in high temperature thermal insulation textile and by controlling the heating coil current using a digital control system. The partial pressure changes were observed using a residual gas analyzer, and a total system pressure of 5x10{sup -8} Torr was finally reached. Diagnostic systems including a millimeter-wave interferometer, a high resolution survey spectrometer, a Langmuir probe, and an ultrasoft x-ray detector were used to provide the evidence that the plasma performance was improved as we desired. In this work, we present characterization of the RAPID device for various system conditions and configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of two color laser diagnostics for the ITER poloidal polarimeter

Two color laser diagnostics using terahertz laser sources are under development for a high performance operation of the Large Helical Device and for future fusion devices such as ITER. So far, we have achieved high power laser oscillation lines simultaneously oscillating at 57.2 and 47.7 {mu}m by using a twin optically pumped CH{sub 3}OD laser, and confirmed the original function, compensation of mechanical vibration, of the two color laser interferometer. In this article, application of the two color laser diagnostics to the ITER poloidal polarimeter and recent hardware developments will be described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: A robust low-cost high-sensitivity subangstrom bidirectional displacement sensor

The design of a simple, robust, low-cost, and bidirectional displacement sensor with subangstrom resolution is described. A small gold plate is attached to the object, whose displacement is to be measured, and a small gold tip is brought into contact with the plate, establishing a reference current between the two. Movements of the gold plate away from the tip lead to a change in the tip-plate current; the reference current is then re-established by moving the tip using a simple magnetic actuator. The resolution of the sensor has been calibrated using an interferometer and was shown to be as high as 0.3 A per system count. Potential applications of the sensor are numerous, including microbar air pressure measurement, motion and infrasound detection, thermal sensing, and gravitational field and relativistic gravity wave measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time and space resolved interferometry for laser-generated fast electron measurements

A technique developed to measure in time and space the dynamics of the electron populations resulting from the irradiation of thin solids by ultraintense lasers is presented. It is a phase reflectometry technique that uses an optical probe beam reflecting off the target rear surface. The phase of the probe beam is sensitive to both laser-produced fast electrons of low-density streaming into vacuum and warm solid density electrons that are heated by the fast electrons. A time and space resolved interferometer allows to recover the phase of the probe beam sampling the target. The entire diagnostic is computationally modeled by calculating the probe beam phase when propagating through plasma density profiles originating from numerical calculations of plasma expansion. Matching the modeling to the experimental measurements allows retrieving the initial electron density and temperature of both populations locally at the target surface with very high temporal and spatial resolution ({approx}4 ps,6 {mu}m). Limitations and approximations of the diagnostic are discussed and analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma Diagnostics of a Capillary Plasma Channel for Laser Guiding

We demonstrated the production of an optical waveguide in a capillary discharge-produced plasma using a cylindrical capillary. Plasma parameters of its waveguide were characterized by use of both a Normarski laser interferometer and a hydrogen plasma line spectrum. A space-averaged maximum temperature of 3.3 eV with electron densities of the order of 10{sup 17} cm{sup -3} was observed at a discharge time of 150 ns and a maximum discharge current of 200 A. An ultrashort, intense laser pulse was guided by use of this plasma channel.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Note: Accuracy of velocity correction for impact of a laser-accelerated miniature flyer with lithium fluoride shock-compressed along the [100] axis

We performed miniature flyer impact experiments to investigate the relationship between the apparent (u{sub a}) and actual (u{sub A}) particle velocities measured by a velocity interferometer in single-crystal lithium fluoride (LiF) that was shock-compressed along the [100] axis. The miniature flyer was accelerated to velocities in the range 652.5-1937.6 m/s by a tabletop pulsed laser. An empirical relationship of u{sub a}= (1.2749 {+-} 0.0102)u{sub A} was obtained. The obtained relationship agreed well with the results of a previous study within the experimental errors and its uncertainty was less than {+-}1%. This result indicates that the present experimental technique is effective for measuring the relationship between u{sub a} and u{sub A} of shocked transparent materials with a comparable accuracy to conventional methods.

36 MATERIALS SCIENCE↗

Observation and numerical analysis of plasma parameters in a capillary discharge-produced plasma channel waveguide

We observed the parameters of the discharge-produced plasma in cylindrical capillary. Plasma parameters of the waveguide were investigated by use of both a Normarski laser interferometer and a hydrogen plasma line spectrum. A space-averaged maximum temperature of 3.3 eV with electron densities of the order of 10{sup 17} cm{sup -3} was observed at a discharge time of 150 ns and a maximum discharge current of 200 A. One-dimensional dissipative magnetohydrodynamic (MHD) code was used to analyze the discharge dynamics in the gas-filled capillary discharge waveguide for high-intensity laser pulses. Simulations were performed for the conditions of the experiment. We compared the temporal behavior of the electron temperature and the radial electron density profiles, measured in the experiment with the results of the numerical simulations. They occurred to be in a good agreement. An ultrashort, intense laser pulse was guided by use of this plasma channel.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗