Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

In-Situ Characterization of Pore Formation Dynamics in Pulsed Wave Laser Powder Bed Fusion

Laser powder bed fusion (LPBF) is an additive manufacturing technology with the capability of printing complex metal parts directly from digital models. Between two available emission modes employed in LPBF printing systems, pulsed wave (PW) emission provides more control over the heat input compared to continuous wave (CW) emission, which is highly beneficial for printing parts with intricate features. However, parts printed with pulsed wave LPBF (PW-LPBF) commonly contain pores, which degrade their mechanical properties. In this study, we reveal pore formation mechanisms during PW-LPBF in real time by using an in-situ high-speed synchrotron x-ray imaging technique. We found that vapor depression collapse proceeds when the laser irradiation stops within one pulse, resulting in occasional pore formation during PW-LPBF. We also revealed that the melt ejection and rapid melt pool solidification during pulsed-wave laser melting resulted in cavity formation and subsequent formation of a pore pattern in the melted track. The pore formation dynamics revealed here may provide guidance on developing pore elimination approaches.

36 MATERIALS SCIENCE↗

Future trends in synchrotron science at NSLS-II

In this paper, we summarize briefly some of the future trends in synchrotron science as seen at the National Synchrotron Light Source II, a new, low emittance source recently commissioned at Brookhaven National Laboratory. We touch upon imaging techniques, the study of dynamics, the increasing use of multimodal approaches, the vital importance of data science, and finally, other enabling technologies. Each are presently undergoing a time of rapid change, driving the field of synchrotron science forward at an ever increasing pace. It is truly an exciting time and one in which Roger Cowley, to whom this journal issue is dedicated, would surely be both invigorated by, and at the heart of.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dissection of the angle of single fluorophore attached to the nucleotide in corkscrewing microtubules

Direct dissection of the angles of single fluorophores under an optical microscope has been a challenging approach to study the dynamics of proteins in an aqueous solution. For angle quantifications of single substrates, however, there was only one report (Nishizaka et al., 2014) because of difficulties of construction of experimental systems with active proteins working at the single-molecule level. We here show precise estimation of orientation of single fluorescent nucleotides bound to single tubulins that comprise microtubule. When single-headed kinesins immobilized on a glass surface drive the sliding of microtubules, microtubules show corkscrewing with regular pitches (Yajima et al., 2005 & 2008). We found, by using a three-dimensional tracking microscope, that S8A mutant kinesin also showed precise corkscrewing with a 330-nm pitch, which is 13% longer than that of the wild type. The assay with the mutant was combined with a defocused imaging technique to visualize the rotational behavior of fluorescent nucleotide bound to corkscrewing microtubule. Notably, the defocused pattern of single TAMRA-GTP periodically changed, precisely correlating to its precession movement. The time course of the change in the fluorophore angle projected to the xy-plane enabled to estimate both the fluorophore orientation against microtubule axis and the precision of angle-determination of analyses system. The orientation showed main distribution with peaks at∼40°, 50° and 60°. To identify their molecular conformations, the rigorous docking simulations were performed using an atomic-level structure modeled by fitting x-ray crystal structures to the cryo-electron microscopy map. Among isomers, 2′-O-EDA-GDP labeled with 5- or 6-TAMRA were mainly specified as possible candidates as a substrate, which suggested the hydrolysis of TAMRA-GTP by tubulins. - Highlights: • The mutant of single-headed kinesin drives the corkscrewing of microtubules with a longer pitch. • Orientation of single fluorescent GTP on rotating microtubule was measured by defocused imaging. • The orientation showed the distribution with peaks at∼40°, 50° and 60° against microtubule axis. • Docking simulation reveals possible molecular conformations and state of nucleotide on tubulin.

60 APPLIED LIFE SCIENCES↗

Evaluation of Functional Marrow Irradiation Based on Skeletal Marrow Composition Obtained Using Dual-Energy Computed Tomography

Purpose: To develop an imaging method to characterize and map marrow composition in the entire skeletal system, and to simulate differential targeted marrow irradiation based on marrow composition. Methods and Materials: Whole-body dual energy computed tomography (DECT) images of cadavers and leukemia patients were acquired, segmented to separate bone marrow components, namely, bone, red marrow (RM), and yellow marrow (YM). DECT-derived marrow fat fraction was validated using histology of lumbar vertebrae obtained from cadavers. The fractions of RM (RMF = RM/total marrow) and YMF were calculated in each skeletal region to assess the correlation of marrow composition with sites and ages. Treatment planning was simulated to target irradiation differentially at a higher dose (18 Gy) to either RM or YM and a lower dose (12 Gy) to the rest of the skeleton. Results: A significant correlation between fat fractions obtained from DECT and cadaver histology samples was observed (r=0.861, P<.0001, Pearson). The RMF decreased in the head, neck, and chest was significantly inversely correlated with age but did not show any significant age-related changes in the abdomen and pelvis regions. Conformity of radiation to targets (RM, YM) was significantly dependent on skeletal sites. The radiation exposure was significantly reduced (P<.05, t test) to organs at risk (OARs) in RM and YM irradiation compared with standard total marrow irradiation (TMI). Conclusions: Whole-body DECT offers a new imaging technique to visualize and measure skeletal-wide marrow composition. The DECT-based treatment planning offers volumetric and site-specific precise radiation dosimetry of RM and YM, which varies with aging. Our proposed method could be used as a functional compartment of TMI for further targeted radiation to specific bone marrow environment, dose escalation, reduction of doses to OARs, or a combination of these factors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Extracellular vesicles of calcifying turkey leg tendon characterized by immunocytochemistry and high voltage electron microscopic tomography and 3-D graphic image reconstruction

To gain insight into the structure and possible function of extracellular vesicles in certain calcifying vertebrate tissues, normally mineralizing leg tendons from the domestic turkey, Meleagris gallopavo, have been studied in two separate investigations, one concerning the electron microscopic immunolocalization of the 66 kDa phosphoprotein, osteopontin, and the other detailing the organization and distribution of mineral crystals associated with the vesicles as determined by high voltage microscopic tomography and 3-D graphic image reconstruction. Immunolabeling shows that osteopontin is related to extracellular vesicles of the tendon in the sense that its initial presence appears coincident with the development of mineral associated with the vesicle loci. By high voltage electron microscopy and 3-D imaging techniques, mineral crystals are found to consist of small irregularly shaped particles somewhat randomly oriented throughout individual vesicles sites. Their appearance is different from that found for the mineral observed within calcifying tendon collagen, and their 3-D disposition is not regularly ordered. Possible spatial and temporal relationships of vesicles, osteopontin, mineral, and collagen are being examined further by these approaches.

NASA Discipline Musculoskeletal↗

Broadband X-ray ptychography using multi-wavelength algorithm

Ptychography is a rapidly developing scanning microscopy which is able to view the internal structures of samples at a high resolution beyond the illumination size. The achieved spatial resolution is theoretically dose-limited. A broadband source can provide much higher flux compared with a monochromatic source; however, it conflicts with the necessary coherence requirements of this coherent diffraction imaging technique. In this paper, a multi-wavelength reconstruction algorithm has been developed to deal with the broad bandwidth in ptychography. Compared with the latest development of mixed-state reconstruction approach, this multi-wavelength approach is more accurate in the physical model, and also considers the spot size variation as a function of energy due to the chromatic focusing optics. Therefore, this method has been proved in both simulation and experiment to significantly improve the reconstruction when the source bandwidth, illumination size and scan step size increase. It is worth mentioning that the accurate and detailed information of the energy spectrum for the incident beam is not required in advance for the proposed method. Further, we combine multi-wavelength and mixed-state approaches to jointly solve temporal and spatial partial coherence in ptychography so that it can handle various disadvantageous experimental effects. The significant relaxation in coherence requirements by our approaches allows the use of high-flux broadband X-ray sources for high-efficient and high-resolution ptychographic imaging.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

BCARS Simulated Phantom Dataset for Evaluation of Processing Pipelines

Broadband coherent anti-Stokes Raman scattering (BCARS) microscopy is a powerful label-free biological imaging technique, but the raw signal requires careful processing. The vibrationally resonant (Raman) fingerprint signal is usually small compared with instrumental noise sources and the nonresonant background (NRB) inherent in the BCARS signal. Fortunately, the NRB exhibits a systematic phase relationship with the coherent Raman response, acting as a heterodyne amplifier for the weak fingerprint signal. Due to this heterodyne effect, the Raman response can be recovered quantitatively and invariantly across different instruments, provided the NRB shape is known. Even with heterodyne amplification, the amplitudes of fingerprint signal components are often comparable to system noise. Singular value decomposition (SVD), which utilizes spatial information, is often employed for additional noise filtering. Consequently, finding optimal processing parameters to properly distinguish the NRB and Raman responses and suppress noise in the complex BCARS signal requires a reference system that realistically represents the spectral and spatial properties of BCARS signals obtained from biological samples. We present a digital tissue phantom that meets these criteria as a tool for testing candidate signal processing pipelines. The digital phantom is generated with simulated hyperspectral Raman images having system-specific noise and background characteristics. Here, we analyze phantom datasets with differing background and signal-to-noise conditions to evaluate their impact on the performance of multiple signal processing pipelines. Specifically, we investigate the application of a Butterworth filter-based routine to directly estimate the NRB from the BCARS signal. Additionally, we evaluate a Lorentzian wavelet transform as an alternative to the Hilbert transform for extracting the Raman spectrum from the BCARS signal. While we demonstrate this phantom for BCARS, it can be used for any spectroscopic Raman imaging approach.

Dixon, Jessica Z. [Georgia Institute of Technology↗

Study on coalescence dynamics of unequal-sized microbubbles captive on solid substrate

The dynamics of bubble coalescence are of importance for a number of industrial processes, in which the size inequality of the parent bubbles plays a significant role in mass transport, topological change and overall motion. In this study, coalescence of unequal-sized microbubbles captive on a solid substrate was observed from cross-section view using synchrotron high-speed imaging technique and a microfluidic gas generation device. The bridging neck growth and surface wave propagation at the early stage of coalescence were investigated by experimental and numerical methods. The results show that theoretical half-power-law of neck growth rate is still valid when viscous effect is neglected. However, the inertial-capillary time scale is associated with the initial radius of the smaller parent microbubble. Furthermore the surface wave propagation rate on the larger parent microbubble is proportional to the inertial-capillary time scale.

42 ENGINEERING↗

Microstructural characterization of SiO2/Ni nanocomposites electrodeposited from a sulphate bath modified by PEI

Highlights: • SiO{sub 2}/Ni + PEI nanocomposites are deposited from the sulphate bath containing PEI. • PEI allows incorporation of higher SiO{sub 2} vol% in SiO{sub 2}/Ni + PEI nanocomposites. • PEI in the form of a thin layer surrounds spherical Ni nanograins and SiO{sub 2} clusters. • PEI action ensures high hardness, tribological properties and corrosion resistance. - Abstract: SiO{sub 2}/Ni nanocomposite coatings containing well-dispersed SiO{sub 2} nanoparticles were electrodeposited from a sulphate bath with and without the addition of polyethylenimine (PEI) as a cationic surfactant. The surface morphology and microstructure in the cross-sections of the deposited nanocomposites were examined by scanning electron microscopy. More detailed microstructure characterization was performed using transmission, scanning-transmission and high resolution transmission electron microscopy. It was determined that the addition of 0.05 g/L and 0.1 g/L of PEI allows the incorporation of SiO{sub 2} nanoparticles in the nickel matrix to be increased in comparison with the nanocomposite deposited without a surfactant. Based on high spatial resolution microanalysis, performed using high count rate energy dispersive spectroscopy of characteristic X-rays in the scanning-transmission mode, the distribution of SiO{sub 2} nanoparticles in the nanocomposite was visualized on elemental maps. Image analysis of the electron microscopy images enabled the mean equivalent circle diameters of grains in the nickel matrix to be determined, together with the volume fraction of SiO{sub 2} nanoparticles in the nanocomposites. The volume fraction of SiO{sub 2} clusters in the SiO{sub 2}/Ni + PEI nanocomposites with the addition of 0.05 g/L and 0.1 g/L of PEI is equal to 18.4% and 13.3%, respectively. Furthermore, the PEI addition allows the nickel grain size in the matrix to be reduced. The combination of different imaging techniques confirmed that PEI is not only present as a surfactant in the electrolytic bath, but also incorporates into the microstructure of the nanocomposite. Nanocomposites electrodeposited in the presence of 0.05 g/L of PEI exhibit higher hardness, good tribological properties and improved corrosion resistance. Although increasing the PEI concentration in the bath up to 0.1 g/L strongly promotes grain size reduction and increase of the SiO{sub 2} volume fraction, it also causes an increase in the PEI fraction embedded in the microstructure, which results in deterioration of the properties of the SiO{sub 2}/Ni + PEI nanocomposites.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Development of a dynamic quality assurance testing protocol for multisite clinical trial DCE-CT accreditation

Purpose: Credentialing can have an impact on whether or not a clinical trial produces useful quality data that is comparable between various institutions and scanners. With the recent increase of dynamic contrast enhanced-computed tomography (DCE-CT) usage as a companion biomarker in clinical trials, effective quality assurance, and control methods are required to ensure there is minimal deviation in the results between different scanners and protocols at various institutions. This paper attempts to address this problem by utilizing a dynamic flow imaging phantom to develop and evaluate a DCE-CT quality assurance (QA) protocol.Methods: A previously designed flow phantom, capable of producing predictable and reproducible time concentration curves from contrast injection was fully validated and then utilized to design a DCE-CT QA protocol. The QA protocol involved a set of quantitative metrics including injected and total mass error, as well as goodness of fit comparison to the known truth concentration curves. An additional region of interest (ROI) sensitivity analysis was also developed to provide additional details on intrascanner variability and determine appropriate ROI sizes for quantitative analysis. Both the QA protocol and ROI sensitivity analysis were utilized to test variations in DCE-CT results using different imaging parameters (tube voltage and current) as well as alternate reconstruction methods and imaging techniques. The developed QA protocol and ROI sensitivity analysis was then applied at three institutions that were part of clinical trial involving DCE-CT and results were compared.Results: The inherent specificity of robustness of the phantom was determined through calculation of the total intraday variability and determined to be less than 2.2 ± 1.1% (total calculated output contrast mass error) with a goodness of fit (R{sup 2}) of greater than 0.99 ± 0.0035 (n= 10). The DCE-CT QA protocol was capable of detecting significant deviations from the expected phantom result when scanning at low mAs and low kVp in terms of quantitative metrics (Injected Mass Error 15.4%), goodness of fit (R{sup 2}) of 0.91, and ROI sensitivity (increase in minimum input function ROI radius by 146 ± 86%). These tests also confirmed that the ASIR reconstruction process was beneficial in reducing noise without substantially increasing partial volume effects and that vendor specific modes (e.g., axial shuttle) did not significantly affect the phantom results. The phantom and QA protocol were finally able to quickly (<90 min) and successfully validate the DCE-CT imaging protocol utilized at the three separate institutions of a multicenter clinical trial; thereby enhancing the confidence in the patient data collected.Conclusions: A DCE QA protocol was developed that, in combination with a dynamic multimodality flow phantom, allows the intrascanner variability to be separated from other sources of variability such as the impact of injection protocol and ROI selection. This provides a valuable resource that can be utilized at various clinical trial institutions to test conformance with imaging protocols and accuracy requirements as well as ensure that the scanners are performing as expected for dynamic scans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging the presence of silane coatings in concrete with micro X-ray fluorescence

Silane is a commonly used surface treatment to reduce fluid entry into the concrete matrix. This work uses micro X-ray fluorescence (μXRF) to image the presence of silane coatings in field samples and the changes made to the paste chemistry. There are many advantages that μXRF has over other imaging techniques due to the large spot size and the high energy levels. Because of this, μXRF can rapidly investigate large areas and requires minimal sample preparation. Quantitative measurements are made to show that there is a reduction in the amount of sulfur and an increase in potassium in the hydrophobic regions formed by silane coatings. These measurements provide important insights into modifications made to the concrete matrix when silane sealers are used. The mechanisms for the observed chemistry changes are discussed and a simple field or laboratory test method is presented that uses a dye to detect silane coatings.

36 MATERIALS SCIENCE↗

Experimental investigation of fuel temperature effects on transient needle motion and injection velocity of solenoid type diesel injector

Real driving emission (RDE) test conducted in sub-zero temperature conditions has been acting as a severe emission regulation over the existing test methods for diesel engines. In order to cope with this tightened regulation, many studies have been conducted to interpret the factors causing the deteriorated diesel engine combustion in cold operation conditions. The deteriorated fuel injection performance has been regarded as one of the key contributing factors but the governing mechanisms are not thoroughly understood so far. This study aims to provide a comprehensive understanding of the effects of fuel temperature including sub-zero conditions on fuel injection performance by measuring the transient needle motion and injection velocity of a diesel injector using synchrotron X-ray imaging techniques. Here, the factors causing the deteriorated injector performance and their contributions are discussed thoroughly based on the results. The results showed that the injection duration was shortened as the fuel temperature decreased as a result of decreased needle opening speed and increased needle closing speed. The increase of fuel viscosity and bulk modulus was discussed as the main factors associated with these results. The total injection mass was reduced by lowering the fuel temperature not only by the shortened injection duration but also by the decreased injection velocity. These factors exerted near equivalent contribution to the reduced injection mass at low fuel temperatures.

42 ENGINEERING↗

Importance of one- and two-photon transitions in the strong-field dissociation of NO 2+

Employing a coincidence three-dimensional momentum imaging technique, we investigate the ultrafast, intense laser-induced dissociation of a metastable NO 2+ ion beam into N + + O + . Based on the kinetic energy release and angular distributions, measured using both 774-nm and second-order-harmonic 387-nm pulses, we show that the main processes driving dissociation in pulses of about 10 14 W/cm 2 peak intensity are one- and two-photon transitions from the X 2 Σ + ground state to the A 2 Π first-excited state. First-order perturbation theory calculations also corroborate these findings.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

In-situ L-TEM observations of dynamics of nanometric skyrmions and antiskyrmions

Nanometer-scale magnetic skyrmions and antiskyrmions exhibit unique dynamical behaviors in response to external stimuli, which are critical for their applications in low-power-consumption spintronic devices. This review discusses recent advancements in in-situ Lorentz transmission electron microscopy (L-TEM) observations of skyrmion and antiskyrmion dynamics, and demonstrates the manipulation and evolution of these textures in various magnetic materials under electric, magnetic, and thermal stimuli. Specifically, the motion tracking of single skyrmions and their clusters, and the deformation and transformation of skyrmions has been demonstrated in chiral helimagnets FeGe, Co 9 Zn 9 Mn 2 , and Co 10 Zn 10 with precise application of electric currents. Skyrmions can undergo dynamic transitions in current-driven skyrmion motions, from pinned states to linear flows, and even exhibit deformation into elliptical shapes, underscoring their topological robustness and dynamic flexibility. In addition, the manipulation of single antiskyrmions and antiskyrmion-lattice phases in (Fe 0.63 Ni 0.3 Pd 0.07 ) 3 P with S 4 symmetry is discussed, highlighting their high mobility and unique sliding capabilities along stripe domains at room temperature, facilitated by nanosecond pulsed electric currents. Finally, the temperature gradient-driven motion and topological transformation of elliptical skyrmions and antiskyrmions in this same material are investigated. In conclusion, the comprehensive insights gained from the L-TEM imaging technique are pivotal in advancing the design and functionality of next-generation skyrmion/antiskyrmion-based spintronic devices.

(Anti)skyrmion↗

Progression of soot cake layer properties during the systematic regeneration of diesel particulate filters measured with neutron tomography

Although particulate filters (PFs) have been a key component of the emission control system for modern diesel engines, there remain significant questions about the basic regeneration behavior of the filters and how it changes with accumulation of increasing soot layers. This effort describes a systematic deposition and regeneration of particulate matter in 25-mm diameter × 76-mm long wall-flow PFs composed of silicon carbide (SiC) material. The initial soot distributions were analyzed for soot cake thickness using a nondestructive neutron imaging technique. With the PFs intact, it was then possible to sequentially regenerate the samples and reanalyze them, which was performed after nominal 20, 50, and 70 % regenerations. The loaded samples show a relatively uniform distribution of particulate with an increasing soot cake thickness and nearly identical initial density of 70 mg/cm 3 . Throughout regeneration, the soot cake thickness initially decreases significantly while the density increases to 80–90 mg/cm 3 . After ~50 % regeneration, the soot cake thickness stays relatively constant, but instead, the density decreases as pores open up in the layer (~35 mg/cm 3 at 70 % regeneration). Here, complete regeneration initially occurs at the rear of the PF channels. With this information, a conceptual model of the regeneration is proposed.

54 ENVIRONMENTAL SCIENCES↗

Ion-coincidence momentum imaging of three-body Coulomb explosion of formaldehyde in ultrashort intense laser fields

Three-body Coulomb explosion of formaldehyde (H{sub 2}CO) in intense 7- and 35-fs laser fields (1.3 × 10{sup 15} W/cm{sup 2}) has been investigated by using ion-coincidence momentum imaging technique. Two types of explosion pathways from the triply charged state, H{sub 2}CO{sup 3+} → (i) H{sup +} + H{sup +} + CO{sup +} and (ii) H{sup +} + CH{sup +} + O{sup +}, have been identified. It is shown from the momentum correlation of the fragment ions of pathway (i), that the geometrical structure of the molecule is essentially frozen along the H-C-H bending coordinate for the 7-fs case. On the other hand, for a longer pulse duration (35 fs), structural deformation along the C-H stretching and H-C-H bending coordinates is identified, which is ascribed to the nuclear dynamics in the dication states populated within the laser pulse duration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Intra-Grain Local Luminescence Properties of CdSe0.1Te0.9 Thin Films

We report on the local photoluminescence properties of grains and grain boundaries of CdSe 0.1 Te 0.9 thin film deposited by the colossal grain growth method using a wide-field hyperspectral imaging technique. We observed significant variations in the photoluminescence intensity of both individual grains and also that of grain boundaries. Multiple sub-bandgap defect peaks were captured in the luminescence spectra in the energy range 1.2 eV to 1.6 eV. The intensity and peak positions of these sub-gap emissions were slightly different among various grains and at the grain boundaries, revealing intra- and inter-grain variations in these polycrystalline thin films. A recently-developed density-of-states based photoluminescence model was extended to include multiple peaks and was fitted to the data. We observed that at a fixed temperature, the quasi-Fermi level splitting energy and a disordered energy parameter can be extracted locally by use of this model.

data models↗

Differences in the hemodynamic response to event-related motor and visual paradigms as measured by near-infrared spectroscopy

Several current brain imaging techniques rest on the assumption of a tight coupling between neural activity and hemodynamic response. The nature of this neurovascular coupling, however, is not completely understood. There is some evidence for a decoupling of these processes at the onset of neural activity, which manifests itself as a momentary increase in the relative concentration of deoxyhemoglobin (HbR). The existence of this early component of the hemodynamic response function, however, is controversial, as it is inconsistently found. Near infrared spectroscopy (NIRS) allows quantification of levels of oxyhemoglobin (HbO(2)) and HbR during task performance in humans. We acquired NIRS data during performance of simple motor and visual tasks, using rapid-presentation event-related paradigms. Our results demonstrate that rapid, event-related NIRS can provide robust estimates of the hemodynamic response without artifacts due to low-frequency signal components, unlike data from blocked designs. In both the motor and visual data the onset of the increase in HbO(2) occurs before HbR decreases, and there is a poststimulus undershoot. Our results also show that total blood volume (HbT) drops before HbO(2) and undershoots baseline, raising a new issue for neurovascular models. We did not find early deoxygenation in the motor data using physiologically plausible values for the differential pathlength factor, but did find one in the visual data. We suggest that this difference, which is consistent with functional magnetic resonance imaging (fMRI) data, may be attributable to different capillary transit times in these cortices.

NASA Program Biomedical Research and Countermeasur↗