Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Segmentation precision of abdominal anatomy for MRI-based radiotherapy

The limited soft tissue visualization provided by computed tomography, the standard imaging modality for radiotherapy treatment planning and daily localization, has motivated studies on the use of magnetic resonance imaging (MRI) for better characterization of treatment sites, such as the prostate and head and neck. However, no studies have been conducted on MRI-based segmentation for the abdomen, a site that could greatly benefit from enhanced soft tissue targeting. We investigated the interobserver and intraobserver precision in segmentation of abdominal organs on MR images for treatment planning and localization. Manual segmentation of 8 abdominal organs was performed by 3 independent observers on MR images acquired from 14 healthy subjects. Observers repeated segmentation 4 separate times for each image set. Interobserver and intraobserver contouring precision was assessed by computing 3-dimensional overlap (Dice coefficient [DC]) and distance to agreement (Hausdorff distance [HD]) of segmented organs. The mean and standard deviation of intraobserver and interobserver DC and HD values were DC{sub intraobserver} = 0.89 ± 0.12, HD{sub intraobserver} = 3.6 mm ± 1.5, DC{sub interobserver} = 0.89 ± 0.15, and HD{sub interobserver} = 3.2 mm ± 1.4. Overall, metrics indicated good interobserver/intraobserver precision (mean DC > 0.7, mean HD < 4 mm). Results suggest that MRI offers good segmentation precision for abdominal sites. These findings support the utility of MRI for abdominal planning and localization, as emerging MRI technologies, techniques, and onboard imaging devices are beginning to enable MRI-based radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Cylindrical Crystal Imaging Spectrometer (CCIS) for cosmic X-ray spectroscopy

A "stigmatic" focusing, Bragg crystal spectrometer was developed and used for high spectral resolution X-ray emission line diagnostics on hot laboratory plasmas. The concept be applied at the focal plane of an orbiting X-ray telescope where it offers several advantages over conventional spectrometers, i.e., mechanical simplicity, high resolving power and sensitivity, simultaneous measurement of an extended segment of spectrum, and good imaging properties. The instrument features a simple, unambiguous, non-scanning spectrum readout that is not adversely affected by either spacecraft pointing error or source extent. The performance of the instrument is estimated in the context of the Advanced X-Ray Astrophysical Facility mission.

Schnopper, H. W.↗

Generic method for automatic bladder segmentation on cone beam CT using a patient-specific bladder shape model

Purpose: The aim of this study is to develop and validate a generic method for automatic bladder segmentation on cone beam computed tomography (CBCT), independent of gender and treatment position (prone or supine), using only pretreatment imaging data. Methods: Data of 20 patients, treated for tumors in the pelvic region with the entire bladder visible on CT and CBCT, were divided into four equally sized groups based on gender and treatment position. The full and empty bladder contour, that can be acquired with pretreatment CT imaging, were used to generate a patient-specific bladder shape model. This model was used to guide the segmentation process on CBCT. To obtain the bladder segmentation, the reference bladder contour was deformed iteratively by maximizing the cross-correlation between directional grey value gradients over the reference and CBCT bladder edge. To overcome incorrect segmentations caused by CBCT image artifacts, automatic adaptations were implemented. Moreover, locally incorrect segmentations could be adapted manually. After each adapted segmentation, the bladder shape model was expanded and new shape patterns were calculated for following segmentations. All available CBCTs were used to validate the segmentation algorithm. The bladder segmentations were validated by comparison with the manual delineations and the segmentation performance was quantified using the Dice similarity coefficient (DSC), surface distance error (SDE) and SD of contour-to-contour distances. Also, bladder volumes obtained by manual delineations and segmentations were compared using a Bland-Altman error analysis. Results: The mean DSC, mean SDE, and mean SD of contour-to-contour distances between segmentations and manual delineations were 0.87, 0.27 cm and 0.22 cm (female, prone), 0.85, 0.28 cm and 0.22 cm (female, supine), 0.89, 0.21 cm and 0.17 cm (male, supine) and 0.88, 0.23 cm and 0.17 cm (male, prone), respectively. Manual local adaptations improved the segmentation results significantly (p < 0.01) based on DSC (6.72%) and SD of contour-to-contour distances (0.08 cm) and decreased the 95% confidence intervals of the bladder volume differences. Moreover, expanding the shape model improved the segmentation results significantly (p < 0.01) based on DSC and SD of contour-to-contour distances. Conclusions: This patient-specific shape model based automatic bladder segmentation method on CBCT is accurate and generic. Our segmentation method only needs two pretreatment imaging data sets as prior knowledge, is independent of patient gender and patient treatment position and has the possibility to manually adapt the segmentation locally.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Image Processing Algorithm Based On FMAT

Information deleted in ways minimizing adverse effects on reconstructed images. New grey-scale generalization of medial axis transformation (MAT), called FMAT (short for Fuzzy MAT) proposed. Formulated by making natural extension to fuzzy-set theory of all definitions and conditions (e.g., characteristic function of disk, subset condition of disk, and redundancy checking) used in defining MAT of crisp set. Does not need image to have any kind of priori segmentation, and allows medial axis (and skeleton) to be fuzzy subset of input image. Resulting FMAT (consisting of maximal fuzzy disks) capable of reconstructing exactly original image.

Wang, Lui↗

Phasing of a space based segmented submillimeter wavelength telescope using focal plane measurements

As part of a technology development program for realizing a space based submillimeter telescope, two different approaches to the absolute phasing of a segmented primary mirror using focal plane measurements have been implemented for feasibility. The method of optimization by simulated annealing evaluates the image quality of a point spread function after all the telescope segments have been randomly moved. It accepts each iteration which improves the image quality, as well as a random number of iterations which do not, thus keeping the Strehl in the initialization procedure from falling into local maxima. Methods for determining the annealing schedule, and the step size for random segment movements are presented and discussed. Using phase diversity and a model for the telescope imaging system, a nonlinear least squares algorithm has also been implemented which parameterizes each of the segment actuator movements. Using multiple out of focus images, the segment actuator positions are estimated using an iterative procedure. Nonlinear least squares, although computationally intensive, offers a large savings in the actuator movements over simulated annealing and pairwise phasing methods for large numbers of segments. These algorithms have been integrated into a general simulation program which models the behavior of the telescope under anticipated space conditions.

Levine, B. M.↗

A Two-Tier Convolutional Neural Network for Combined Detection and Segmentation in Biological Imagery

Deep learning techniques have been useful for modern microscopy imaging techniques to further study and analyze biological structures and organs. Convolutional neural networks (CNN) have improved 2D object detection, localization, and segmentation. For imagery containing biological structures with depth, it is especially desirable to perform these tasks in 3D. Traditionally, performing these tasks simultaneously in 3D has proven to be computationally expensive. Currently available methodologies thus largely work to segment 3D objects from 2D images (without context from captured 3D volumes). In this work, we present a novel approach to perform fast and accurate localization, detection, and segmentation of volumes containing cells. Specifically, in our method, we modify and tune two state-of-the-art CNNs, namely 2D YOLOv2 and 3D U-Net, and combine them with a new fusion and image processing algorithms. Annotated volumes in this space are limited, and we have created synthetic data that mimics actual structures for training and testing our proposed approach. Promising results on this test data demonstrate the value of the technique and offers a methodology for 3D cell analysis in real microscopy imagery.

Ziabari, Amir↗

Application of digital holographic interferometry to pressure measurements of symmetric, supercritical and circulation-control airfoils in transonic flow fields

Six airfoil interferograms were evaluated using a semiautomatic image-processor system which digitizes, segments, and extracts the fringe coordinates along a polygonal line. The resulting fringe order function was converted into density and pressure distributions and a comparison was made with pressure transducer data at the same wind tunnel test conditions. Three airfoil shapes were used in the evaluation to test the capabilities of the image processor with a variety of flows. Symmetric, supercritical, and circulation-control airfoil interferograms provided fringe patterns with shocks, separated flows, and high-pressure regions for evaluation. Regions along the polygon line with very clear fringe patterns yielded results within 1% of transducer measurements, while poorer quality regions, particularly near the leading and trailing edges, yielded results that were not as good.

Torres, Francisco J.↗

Application of digital holographic interferometry to pressure measurements of symmetric, supercritical, and circulation control airfoils in transonic flow fields

Six airfoil interferograms were evaluated using a semiautomatic image-processor system which digitizes, segments, and extracts the fringe coordinates along a polygonal line. The resulting fringe order function was converted into density and pressure distributions and a comparison was made with pressure transducer data at the same wind tunnel test conditions. Three airfoil shapes were used in the evaluation to test the capabilities of the image processor with a variety of flows. Symmetric, supercritical, and circulation-control airfoil interferograms provided fringe patterns with shocks, separated flows, and high-pressure regions for evaluation. Regions along the polygon line with very clear fringe patterns yielded results within 1 percent of transducer measurements, while poorer quality regions, particularly near the leading and trailing edges, yielded results that were not as good.

Torres, Francisco J.↗

Bayesian 3D X-ray computed tomography image reconstruction with a scaled Gaussian mixture prior model

In order to improve quality of 3D X-ray tomography reconstruction for Non Destructive Testing (NDT), we investigate in this paper hierarchical Bayesian methods. In NDT, useful prior information on the volume like the limited number of materials or the presence of homogeneous area can be included in the iterative reconstruction algorithms. In hierarchical Bayesian methods, not only the volume is estimated thanks to the prior model of the volume but also the hyper parameters of this prior. This additional complexity in the reconstruction methods when applied to large volumes (from 512{sup 3} to 8192{sup 3} voxels) results in an increasing computational cost. To reduce it, the hierarchical Bayesian methods investigated in this paper lead to an algorithm acceleration by Variational Bayesian Approximation (VBA) [1] and hardware acceleration thanks to projection and back-projection operators paralleled on many core processors like GPU [2]. In this paper, we will consider a Student-t prior on the gradient of the image implemented in a hierarchical way [3, 4, 1]. Operators H (forward or projection) and H{sup t} (adjoint or back-projection) implanted in multi-GPU [2] have been used in this study. Different methods will be evalued on synthetic volume 'Shepp and Logan' in terms of quality and time of reconstruction. We used several simple regularizations of order 1 and order 2. Other prior models also exists [5]. Sometimes for a discrete image, we can do the segmentation and reconstruction at the same time, then the reconstruction can be done with less projections.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

WE-D-18A-05: Construction of Realistic Liver Phantoms From Patient Images and a Commercial 3D Printer

Purpose: To assess image quality and radiation dose reduction in abdominal CT imaging, physical phantoms having realistic background textures and lesions are highly desirable. The purpose of this work was to construct a liver phantom with realistic background and lesions using patient CT images and a 3D printer. Methods: Patient CT images containing liver lesions were segmented into liver tissue, contrast-enhanced vessels, and liver lesions using commercial software (Mimics, Materialise, Belgium). Stereolithography (STL) files of each segmented object were created and imported to a 3D printer (Object350 Connex, Stratasys, MN). After test scans were performed to map the eight available printing materials into CT numbers, printing materials were assigned to each object and a physical liver phantom printed. The printed phantom was scanned on a clinical CT scanner and resulting images were compared with the original patient CT images. Results: The eight available materials used to print the liver phantom had CT number ranging from 62 to 117 HU. In scans of the liver phantom, the liver lesions and veins represented in the STL files were all visible. Although the absolute value of the CT number in the background liver material (approx. 85 HU) was higher than in patients (approx. 40 HU), the difference in CT numbers between lesions and background were representative of the low contrast values needed for optimization tasks. Future work will investigate materials with contrast sufficient to emulate contrast-enhanced arteries. Conclusion: Realistic liver phantoms can be constructed from patient CT images using a commercial 3D printer. This technique may provide phantoms able to determine the effect of radiation dose reduction and noise reduction techniques on the ability to detect subtle liver lesions in the context of realistic background textures.

60 APPLIED LIFE SCIENCES↗

TH-CD-206-01: Expectation-Maximization Algorithm-Based Tissue Mixture Quantification for Perfusion MRI

Purpose: To investigate the feasibility of estimating the tissue mixture perfusions and quantifying cerebral blood flow change in arterial spin labeled (ASL) perfusion MR images. Methods: The proposed perfusion MR image analysis framework consists of 5 steps: (1) Inhomogeneity correction was performed on the T1- and T2-weighted images, which are available for each studied perfusion MR dataset. (2) We used the publicly available FSL toolbox to strip off the non-brain structures from the T1- and T2-weighted MR images. (3) We applied a multi-spectral tissue-mixture segmentation algorithm on both T1- and T2-structural MR images to roughly estimate the fraction of each tissue type - white matter, grey matter and cerebral spinal fluid inside each image voxel. (4) The distributions of the three tissue types or tissue mixture across the structural image array are down-sampled and mapped onto the ASL voxel array via a co-registration operation. (5) The presented 4-dimensional expectation-maximization (4D-EM) algorithm takes the down-sampled three tissue type distributions on perfusion image data to generate the perfusion mean, variance and percentage images for each tissue type of interest. Results: Experimental results on three volunteer datasets demonstrated that the multi-spectral tissue-mixture segmentation algorithm was effective to initialize tissue mixtures from T1- and T2-weighted MR images. Compared with the conventional ASL image processing toolbox, the proposed 4D-EM algorithm not only generated comparable perfusion mean images, but also produced perfusion variance and percentage images, which the ASL toolbox cannot obtain. It is observed that the perfusion contribution percentages may not be the same as the corresponding tissue mixture volume fractions estimated in the structural images. Conclusion: A specific application to brain ASL images showed that the presented perfusion image analysis method is promising for detecting subtle changes in tissue perfusions, which is valuable for the early diagnosis of certain brain diseases, e.g. multiple sclerosis.

60 APPLIED LIFE SCIENCES↗

Evaluation of advanced automatic PET segmentation methods using nonspherical thin-wall inserts

Purpose: The use of positron emission tomography (PET) within radiotherapy treatment planning requires the availability of reliable and accurate segmentation tools. PET automatic segmentation (PET-AS) methods have been recommended for the delineation of tumors, but there is still a lack of thorough validation and cross-comparison of such methods using clinically relevant data. In particular, studies validating PET segmentation tools mainly use phantoms with thick plastic walls inserts of simple spherical geometry and have not specifically investigated the effect of the target object geometry on the delineation accuracy. Our work therefore aimed at generating clinically realistic data using nonspherical thin-wall plastic inserts, for the evaluation and comparison of a set of eight promising PET-AS approaches. Methods: Sixteen nonspherical inserts were manufactured with a plastic wall of 0.18 mm and scanned within a custom plastic phantom. These included ellipsoids and toroids derived with different volumes, as well as tubes, pear- and drop-shaped inserts with different aspect ratios. A set of six spheres of volumes ranging from 0.5 to 102 ml was used for a baseline study. A selection of eight PET-AS methods, written in house, was applied to the images obtained. The methods represented promising segmentation approaches such as adaptive iterative thresholding, region-growing, clustering and gradient-based schemes. The delineation accuracy was measured in terms of overlap with the computed tomography reference contour, using the dice similarity coefficient (DSC), and error in dimensions. Results: The delineation accuracy was lower for nonspherical inserts than for spheres of the same volume in 88% cases. Slice-by-slice gradient-based methods, showed particularly lower DSC for tori (DSC < 0.5), caused by a failure to recover the object geometry. The region-growing method reached high levels of accuracy for most inserts (DSC > 0.76 except for tori) but showed the largest errors in the recovery of pears and drops dimensions (higher than 10% and 30% of the true length, respectively). Large errors were visible for one of the gradient-based contouring methods when delineating drop-shaped inserts. Low DSC due to systematic underestimation of the volumes was observed for our fuzzy clustering method when using nonspherical inserts. The adaptive iterative thresholding method produced the highest DSC score on our nonspherical dataset (DSC > 0.83, except for tori) and showed robustness to the insert geometry. Conclusions: This study investigated the accuracy of eight PET-AS methods for the delineation of objects with a range of nonspherical geometries. The authors’ results confirmed the robustness of some segmentation approaches, but also showed the weaknesses of some of the other methods implemented, which were not observed with spherical inserts. This work therefore highlights the importance of using a variety of thin-wall inserts with complex geometries for the validation of PET-AS methods and provided useful information for further development of the methods tested.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Poster — Thur Eve — 71: A 4D Multimodal Lung Phantom for Regmentation Evaluation

Segmentation and registration of medical imaging data are two processes that can be integrated (a process termed regmentation) to iteratively reinforce each other, potentially improving efficiency and overall accuracy. A significant challenge is presented when attempting to validate the joint process particularly with regards to minimizing geometric uncertainties associated with the ground truth while maintaining anatomical realism. This work demonstrates a 4D MRI, PET, and CT compatible tissue phantom with a known ground truth for evaluating registration and segmentation accuracy. The phantom consists of a preserved swine lung connected to an air pump via a PVC tube for inflation. Mock tumors were constructed from sea sponges contained within two vacuum-sealed compartments with catheters running into each one for injection of radiotracer solution. The phantom was scanned using a GE Discovery-ST PET/CT scanner and a 0.23T Phillips MRI, and resulted in anatomically realistic images. A bifurcation tracking algorithm was implemented to provide a ground truth for evaluating registration accuracy. This algorithm was validated using known deformations of up to 7.8 cm using a separate CT scan of a human thorax. Using the known deformation vectors to compare against, 76 bifurcation points were selected. The tracking accuracy was found to have maximum mean errors of −0.94, 0.79 and −0.57 voxels in the left-right, anterior-posterior and inferior-superior directions, respectively. A pneumatic control system is under development to match the respiratory profile of the lungs to a breathing trace from an individual patient.

60 APPLIED LIFE SCIENCES↗

Automated CT registration, segmentation, and quantification (AutoCT) v1.0

Processing and analyzing brain imaging is crucial in both scientific development and clinical field. In this software package, we build a pipeline that integrates automatic registration, segmentation, and quantitative analysis for subjects' CT scans. Leveraging diffeomorphic transformations, we enable optimized forward and inverse mappings between an image and the reference. Furthermore, we extract localized features from deformation field based on an online template process, which advances statistical learning downstream. The created templates, atlas as well as our methods provide the brain imaging community tools for AI implementations.

Essiari, Abdelilah↗

Automated CT registration, segmentation, and quantification (AutoCT) v1.1

Processing and analyzing brain imaging is crucial in both scientific development and clinical field. In this software package, we build a pipeline that integrates automatic registration, segmentation, and quantitative analysis for subjects' CT scans. Leveraging diffeomorphic transofrmations, we enable optimized forward and inverse mappings between an image and the reference. Furthermore, we extract localized features from deformation field based on an online template process, which advances statistical learning downstream. The created templates, atlas as well as our methods provide the brain imaging community tools for AI implementations

Bai, Zhe↗

automesh: Automatic mesh generation in Rust

automesh is an open-source Rust software program that uses a segmentation, typically generated from a 3D image stack, to create a finite element mesh, composed either of hexahedral (volumetric) or triangular (isosurface) elements. automesh converts between segmentation formats (.npy, .spn) and mesh formats (.exo, .inp, .mesh, .stl, .vtk). automesh can defeature voxel domains, apply Laplacian and Taubin smoothing, and output mesh quality metrics. automesh uses an internal octree for fast performance.

Hovey, Chad Brian [Sandia National Laboratories (S↗

Model-based image change quantification

A system is provided for identifying and quantizing a change in a scene having objects based on comparison of features representing a target object derived from a first image and a second image that includes the target object. The system segments, based on a scene model of the scene, a second image that includes the target object to identify a second area representing the target object within the second image. The system extracts, from the second image, second features for the target object based on the second area. The system determines a second effectiveness of the second features indicating effectiveness of the second features in representing the target object. The system detects a change based on a difference between first features and the second features factoring in a first effectiveness and the second effectiveness.

Roberts, Randy S.↗

Discovery of segmented Fermi surface induced by Cooper pair momentum

Imaging a peculiar Fermi surface Running a current through a superconductor can cause the superconducting gap to close on a section of the Fermi surface. However, observing this segmented Fermi surface directly is tricky. To do so, Zhu et al . worked with a thin film of the topological insulator bismuth telluride placed on top of superconducting niobium diselenide. A small applied magnetic field caused a screening current, which in turn led to a segmented Fermi surface in the topological insulator layer. Using a scanning tunneling microscope, the researchers were able to map out this Fermi surface. —JS

Science & Technology - Other Topics↗