Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “home performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Test Protocol for Room-to-Room Distribution of Outside Air by Residential Ventilation Systems

This test and analysis protocol has been developed as a practical approach for measuring outside air distribution in homes. It has been used successfully in field tests and has led to significant insights on ventilation design issues. Performance advantages of more sophisticated ventilation systems over simpler, less-costly designs have been verified, and specific problems, such as airflow short-circuiting, have been identified.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Subsystem design package for Solar II collector

The requirements for the design and performance of the Solar 2 Collector Subsystem developed for use in solar heating of single family residences and mobile homes are presented. Installation drawings are included.

Source record↗

On-Board Switching and Routing Advanced Technology Study

Future satellite communications is expected to be fully integrated into National and Global Information Infrastructures (NII/GII). These infrastructures will carry multi gigabit-per-second data rates, with integral switching and routing of constituent data elements. The satellite portion of these infrastructures must, therefore, be more than pipes through the sky. The satellite portion will also be required to perform very high speed routing and switching of these data elements to enable efficient broad area coverage to many home and corporate users. The technology to achieve the on-board switching and routing must be selected and developed specifically for satellite application within the next few years. This report presents evaluation of potential technologies for on-board switching and routing applications.

Yegenoglu, F.↗

MEASURED SPACE CONDITIONING PERFORMANCE OFA VERTICAL-BORE GROUND SOURCE HEAT PUMP (GSHP) OVER TWELVE MONTHS UNDER SIMULATED OCCUPANCY LOADS

This paper presents monthly performance metrics of a 7.56 kW (2.16 ton) GSHP serving the space conditioning loads of a 251m2 (2700ft2) residential home with a phase change material in its envelope, and a single vertical-bore 94.5m (310 ft) ground loop. The same ground loop also serviced a ground source heat pump water heater. Envelope characteristics are discussed briefly in the context of reducing thermal losses. Data on entering water temperatures, energy extracted from the ground, energy delivered/removed, compressor electricity use, COP, GSHP run times (low and high compressor stages), and the impact of fan and pump energy consumption on efficiency are presented for each month. Both practical as well as research and development issues are discussed. The findings suggest that GSHPs represent a practical technology option to reduce source energy reduction and greenhouse emissions under the IECC 2012 Standard, as well as the European Union (EU) 2020 target of generating over 25% of heat consumed in the EU from renewable energy.

Exergy↗

Building America Case Study: Multifamily Central Heat Pump Water Heaters, Davis, California

Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16-month period were then used to validate a TRNSYS simulation model. The TRNSYS model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.

30 DIRECT ENERGY CONVERSION↗

Building America Case Study: Multifamily Central Heat Pump Water Heaters, Davis, California

Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16-month period were then used to validate a TRNSYS simulation model. The TRNSYS model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.

ARBI↗

Investigation of crew performance in a multi-vehicle supervisory control task

Crew information processing and decision making in a supervisory control task which is loosely based on the mission of future generation helicopters is measured and represented. Subjects control the motion and activities of their own vehicle and direct the activities of four additional craft. The task involves searching an uncertain environment for cargo and enemies, returning cargo to home base and destroying enemies while attempting to avoid destruction of the scout and the supervised vehicles. A series of experiments with two-person crews and one-person crews were performed. Resulting crew performance was modeled with the objective of describing and understanding the information processing strategies utilized. Of particular interest are problem simplification strategies under time stress and high work load, simplification and compensation in the one-person cases, crew coordination in the two-person cases, and the relationship between strategy and errors in all cases. The results should provide some insight into the effective use of aids, particularly aids based on artificial intelligence, for similar tasks. The simulation is described which is used for the study and some preliminary results from the first two-person crew study are discussed.

Miller, R. A.↗

National Residential Efficiency Measures Database Aimed at Reducing Risk for Residential Retrofit Industry [Fact Sheet]

This technical highlight describes NREL research to develop a publicly available database of energy retrofit measures containing performance characteristics and cost estimates for nearly 3,000 measures. Researchers at the U.S. Department of Energy (DOE) National Renewable Energy Laboratory (NREL) have developed the National Residential Efficiency Measures Database, a public database that characterizes the performance and costs of common residential energy efficiency measures. The data are available for use in software programs that evaluate cost-effective retrofit measures to improve the energy efficiency of residential buildings. The database provides a single, consistent source of current data for DOE and private-sector energy audit and simulation software tools and the retrofit industry. The database will reduce risk for residential retrofit industry stakeholders by providing a central, publicly vetted source of up-to-date information.

14 SOLAR ENERGY↗

National Residential Efficiency Measures Database Aimed at Reducing Risk for Residential Retrofit Industry (Fact Sheet)

This technical highlight describes NREL research to develop a publicly available database of energy retrofit measures containing performance characteristics and cost estimates for nearly 3,000 measures. Researchers at the U.S. Department of Energy (DOE) National Renewable Energy Laboratory (NREL) have developed the National Residential Efficiency Measures Database, a public database that characterizes the performance and costs of common residential energy efficiency measures. The data are available for use in software programs that evaluate cost-effective retrofit measures to improve the energy efficiency of residential buildings. The database provides a single, consistent source of current data for DOE and private-sector energy audit and simulation software tools and the retrofit industry. The database will reduce risk for residential retrofit industry stakeholders by providing a central, publicly vetted source of up-to-date information.

14 SOLAR ENERGY↗

Magnetotelluric Data from Mountain Home, ID

This dataset includes magnetotelluric transfer functions in the form of EDI files for 16 stations collected by the USGS and 40 stations collected by Quantec Geoscience for Lawerence Berkeley National Lab around the Mountain Home area in Idaho. A 3D electrical resistivity model is included that images resistive and conductive bodies in the subsurface that maybe important for geothermal characterization. The model was created using ModEM using the high performance computer Yeti at the USGS.

15 GEOTHERMAL ENERGY↗

Economic Sizing of Batteries for the Smart Home: Preprint

This paper presents a methodology to economically size a home battery based on parametric analysis using home energy management system (HEMS) software to optimally dispatch the battery along with controllable loads under several use cases. We account for connected equipment, controls, renewable resources, and other factors such as building characteristics and utility tariffs. The paper defines an analytical pathway for such a sizing tool, develops initial sizing guidance, and clarifies technical and market opportunities for home batteries in the context of existing and emerging equipment and control technologies. A parametric analysis that included 132 scenarios has been performed based on different combinations of pertinent parameters. Results indicate that four variables dominate the decision-making process: application scenarios (new construction or retrofit), utility tariffs, existence of HEMS, and the anticipated payback time. Life-cycle cost analysis indicated that in the absence of utility incentives, batteries plus HEMS have a payback time of longer than 10 years for new construction under a time-of-use rate structure and feed-in tariff; larger batteries have a longer payback time but may provide more benefits to utilities on reducing power backfeed under certain circumstances.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New Rating Opening Windows to a World of Comfort, Opportunity, and Cost-Effective Savings

Window attachments offer a huge, cost-effective energy-saving opportunity that remains largely untapped. The newly launched window attachment energy rating and certification program, through the Attachments Energy Rating Council (AERC), is altering the way people think about residential and commercial window attachments by providing reliable, easy-to-understand energy performance information to consumers. Window attachments, such as blinds, shades, shutters, awnings, and low-emissivity (low-e) storm windows, represent an enormous existing market. With 64% of U.S. homes having single- or double-pane clear (non-low-e) less-efficient windows, the savings opportunity is significant. Studies of model homes show energy savings of 10% or more after installing more efficient storm window and cellular shades technologies (AERC 2016).In a study conducted by Efficiency Vermont, 68% of respondents had concerns with their existing windows and could benefit from an upgrade (Efficiency Vermont 2016).Through AERC, window attachment products are rated based on their Energy Performance (EP). The EP metric is an easy-to-understand comparative metric created for consumers. This rating not only allows consumers to make more informed decisions when buying attachments products, but also creates a new energy savings measure for utilities and efficiency programs to incentivize energy efficient window attachment products. This paper will outline the savings potential of window attachments, introduce the AERC rating program, detail the methodology behind the Energy Performance ratings, and explain the AERCalc tool that generates the ratings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New Rating Opening Windows to a World of Comfort, Opportunity, and Cost-Effective Savings

Window attachments offer a huge, cost-effective energy-saving opportunity that remains largely untapped. The newly launched window attachment energy rating and certification program, through the Attachments Energy Rating Council (AERC), is altering the way people think about residential and commercial window attachments by providing reliable, easy-to-understand energy performance information to consumers. Window attachments, such as blinds, shades, shutters, awnings, and low-emissivity (low-e) storm windows, represent an enormous existing market. With 64% of U.S. homes having single- or double-pane clear (non-low-e) less-efficient windows, the savings opportunity is significant. Studies of model homes show energy savings of 10% or more after installing more efficient storm window and cellular shades technologies (AERC 2016). In a study conducted by Efficiency Vermont, 68% of respondents had concerns with their existing windows and could benefit from an upgrade (Efficiency Vermont 2016). Through AERC, window attachment products are rated based on their Energy Performance (EP). The EP metric is an easy-to-understand comparative metric created for consumers. This rating not only allows consumers to make more informed decisions when buying attachments products, but also creates a new energy savings measure for utilities and efficiency programs to incentivize energy efficient window attachment products. Here, this paper will outline the savings potential of window attachments, introduce the AERC rating program, detail the methodology behind the Energy Performance ratings, and explain the AERCalc tool that generates the ratings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Power and Communications Hardware-in-the-Loop CPS Architecture and Platform for DER Monitoring and Control Applications: Preprint

The rapid growth of distributed energy resources (DERs) has prompted increasing interest in the monitoring and control of DERs through hybrid smart grid communications. The deployment of communications and computation has transformed the traditional physical power grid into a smart cyber-physical system (CPS). To fully understand the interdependency between physical grid and cyber netowrks, this study designed a power and communications hardware-in-the-loop (PCommHIL) CPS architecture, which enables the flexible verification of DER monitoring and control with hybrid communications architectures and Internet protocols. Design, development and case study of a PCommHIL testbed for the DER coordination are discussed in detail, and the proposed platform integrates DER devices, Advanced Metering Infrastructures (AMIs), and a suite of hybrid communications networks for distribution automation applications. Case study on DER situational awareness and Volt-Var control validates the efficacy of this proposed PCommHIL platform with hybrid communications designs. Results show that the HAN communication technologies play a critical role in hybrid designs and it is the bottleneck for DER applications. High performance communication technologies are highly recommended to be applied in the HAN for enhanced monitoring and real-time control of DERs.

AMIs↗

High-R Walls for New Construction Structural Performance: Integrated Rim Header Testing

Two prominent approaches within the Building America Program to construct higher R-value walls have included use of larger dimension framing and exterior rigid foam insulation. These approaches have been met with some success; however for many production builders, where the cost of changing framing systems is expensive, the changes have been slow to be realized. In addition, recent building code changes have raised some performance issues for exterior sheathing and raised heel trusses, for example, that indicates a need for continued performance testing for wall systems. The testing methods presented in this report evaluate structural rim header designs over openings up to 6 ft wide and applicable to one- and two-story homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design And Performance Of Optical Detectors Fabrication Setup Using Pulsed Laser Deposition (PLD)

PLD system was used in the preparation of nano structured thin layers to be used as optical detectors. Our home made on--axis PLD setup utilizes XeCl excimer laser (308 nm, Pulse duration of 7 ns, repetition rate of 200 Hz). The laser energy is kept at 8 mj, and the vacuum chamber has been pumped to a background pressure of 10{sup -5} mbar. The films can be grown at different substrate temperatures in the range of 25-400 deg. C. The substrate temperature was always kept below 400 deg. C by using advanced temperature control system. The target-to-substrate distance was variable from 2 to 6 cm. SiO{sub 2} was used as substrates because of its low refractive index and high transparency in the UV, visible and near infrared ranges of spectra. LIPS technique has been used for plasma diagnoses during film deposition, using a double monochromator provided with photon detector. Homogenous thin films in the order of 20-200 nm thickness were obtained. Moreover, both amorphous and crystalline thin films can be obtained by adjusting the substrate temperature, target--substrate distance, type of substrate and finally pressure of ambient gas.

36 MATERIALS SCIENCE↗

Pollutant concentrations and emission rates from natural gas cooking burners without and with range hood exhaust in nine California homes

Combustion pollutant concentrations were measured during the scripted operation of natural gas cooking burners in nine homes. Boiling and simmering activities were conducted on the stovetop and in the oven with and without range hood exhaust ventilation or air mixing via a forced air system. Time-resolved concentrations of carbon dioxide (CO 2 ), nitric oxide (NO), nitrogen oxides (NO x ), nitrogen dioxide (NO 2 ), particles with diameters of 6 nm or larger (PN), carbon monoxide (CO), and fine particulate matter (PM 2.5 ) were measured in the kitchen and bedroom area of each home. Four of the nine homes had kitchen 1 h NO 2 exceed the national ambient air quality standard (100 ppb). In all homes, the highest 1 h integrated PN exceeded 2 × 10 5 cm -3 -h, and the highest 4 h PN exceeded 3 × 10 5 cm -3 -hr in the kitchen. Range hood performance varied widely, but one with a large capture volume and a measured flow of 108 L/s reduced concentrations 80–95%. Increased awareness of the need to ventilate when cooking, along with building standards for minimum range hood flow rates and volume, could substantially reduce exposures to NO 2 and ultrafine particles in homes.

03 NATURAL GAS↗