Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fringe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Proof-of-concept Talbot–Lau x-ray interferometry with a high-intensity, high-repetition-rate, laser-driven K-alpha source

Talbot–Lau x-ray interferometry is a grating-based phase-contrast technique, which enables measurement of refractive index changes in matter with micrometric spatial resolution. The technique has been established using a variety of hard x-ray sources, including synchrotron, free-electron lasers, and x-ray tubes, and could be used in the optical range for low-density plasmas. The tremendous development of table-top high-power lasers makes the use of high-intensity, laser-driven K-alpha sources appealing for Talbot–Lau interferometer applications in both high-energy-density plasma experiments and biological imaging. To this end, we present the first, to the best of our knowledge, feasibility study of Talbot–Lau phase-contrast imaging using a high-repetition-rate laser of moderate energy (100 mJ at a repetition rate of 10 Hz) to irradiate a copper backlighter foil. The results from up to 900 laser pulses were integrated to form interferometric images. A constant fringe contrast of 20% is demonstrated over 100 accumulations, while the signal-to-noise ratio continued to increase with the number of shots. Phase retrieval is demonstrated without prior ex-situ phase stepping. Instead, correlation matrices are used to compensate for the displacement between reference acquisition and the probing of a PMMA target rod. The steps for improved measurements with more energetic laser systems are discussed. The final results are in good agreement with the theoretically predicted outcomes, demonstrating the applicability of this diagnostic to a range of laser facilities for use across several disciplines.

Bouffetier, V. (ORCID:0000000160791260)↗

X-ray shearing interferometer and generalized grating imaging

X-ray shearing interferometers with three gratings are analyzed on the basis of generalized grating imaging theory. The result of this analysis is applied to an already proposed interferometer. The contrast of the imaging fringes in the interferometer is calculated quantitatively. It is also applied to explain the spatial resolution of the image.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deterministic convergence in iterative phase shifting

Previous implementations of the iterative phase shifting method, in which the phase of a test object is computed from measurements using a phase shifting interferometer with unknown positions of the reference, do not provide an accurate way of knowing when convergence has been attained. We present a new approach to this method that allows us to deterministically identify convergence. The method is tested with a home-built Fizeau interferometer that measures optical surfaces polished to {lambda}/100 using the Hydra tool. The intrinsic quality of the measurements is better than 0.5 nm. Other possible applications for this technique include fringe projection or any problem where phase shifting is involved.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Achromatic digital speckle pattern interferometer with constant radial in-plane sensitivity by using a diffractive optical element

We report on a digital speckle pattern interferometer that applies a binary diffractive optical element (DOE) to generate double illumination and radial in-plane sensitivity. The application of the DOE ensures independence on the wavelength of the laser used as an illumination source. Furthermore, in-plane sensitivity only depends on the grating period of the DOE. An experimental setup was built allowing the measurement of a set of radial in-plane displacement fields either using a red laser as a light source or a green one. When displacement fields computed from the measured optical phase maps obtained with a red or a green laser were compared, two main results were observed: (a) deviations between mean values ranged only up to 7 nm and (b) phase maps presented the same amount of fringes. In addition, phase maps measured with the red laser were processed as they were obtained with green light. For this case, deviations have ranged only up to 0.5 nm. On the other hand, a set of measurements performed changing the DOE by a conical mirror showed clearly that radial in-plane sensitivity increased when the red laser was changed by the green one.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improving the reconstruction quality with extension and apodization of the digital hologram

To suppress the aperture diffraction and spectral leakage effects in the reconstruction process of the digital hologram and to maintain the original information recorded in the hologram, a novel reconstruction method based on extension and apodization of the digital hologram is presented, by which the original hologram can be extended by filling the average intensity values of the boundary, and the extended hologram is apodized by use of the constructed window function. As a sample, the digital hologram of the static particle field is recorded and numerically extended and then apodized with the appointed window. Finally, an unabridged and clear digital holographic image is reconstructed from the extended and apodized hologram. The experimental results confirm that this method cannot only eliminate the black-and-white diffraction fringes in the reconstructed image, but also attain the unabridged image with high quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of microperiodic mirrors for hard x-ray phase-contrast imaging

Differential phase-contrast imaging with hard x rays can have important applications in medicine, material sciences, and energy research. Phase-contrast methods based on microperiodic optics, such as shearing interferometry, are particularly attractive because they allow the use of conventional x-ray tubes. To enable shearing interferometry with x rays up to 100 keV, we propose using grazing-incidence microperiodic mirrors. In addition, a simple lithographic method is proposed for the production of the microperiodic x-ray mirrors, based on the difference in grazing-incidence reflectivity between a low-Z substrate and a high-Z film. Using this method, we produced prototype mirrors with 5-100 {mu}m periods and 90 mm active length. Experimental tests with x rays up to 60 keV indicate good microperiodic mirror reflectivity and high-contrast fringe patterns, encouraging further development of the proposed imaging concept.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Extrinsic fiber-optic Fabry-Perot interferometer sensor for refractive index measurement of optical glass

A simple fiber-optic sensor based on Fabry-Perot interference for refractive index measurement of optical glass is investigated both theoretically and experimentally. A broadband light source is coupled into an extrinsic fiber Fabry-Perot cavity formed by the surfaces of a sensing fiber end and the measured sample. The interference signals from the cavity are reflected back into the same fiber. The refractive index of the sample can be obtained by measuring the contrast of the interference fringes. The experimental data meet with the theoretical values very well. The proposed technique is a new method for glass refractive index measurement with a simple, solid, and compact structure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Universal calculation formula and calibration method in Fourier transform profilometry

We propose a universal calculation formula of Fourier transform profilometry and give a strict theoretical analysis about the phase-height mapping relation. As the request on the experimental setup of the universal calculation formula is unconfined, the projector and the camera can be located arbitrarily to get better fringe information, which makes the operation flexible. The phase-height calibration method under the universal condition is proposed, which can avoid measuring the system parameters directly. It makes the system easy to manipulate and improves the measurement velocity. A computer simulation and experiment are conducted to verify its validity. The calculation formula and calibration method have been applied to measure an object of 22.00 mm maximal height. The relative error of the measurement result is only 0.59%. The experimental results prove that the three-dimensional shape of tested objects can be reconstructed exactly by using the calculation formula and calibration method, and the system has better universality.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Random errors in interferometry with the least-squares method

This investigation analyzes random errors in interferometric surface profilers using the least-squares method when random noises are present. Two types of random noise are considered here: intensity noise and position noise. Two formulas have been derived for estimating the standard deviations of the surface height measurements: one is for estimating the standard deviation when only intensity noise is present, and the other is for estimating the standard deviation when only position noise is present. Measurements on simulated noisy interferometric data have been performed, and standard deviations of the simulated measurements have been compared with those theoretically derived. The relationships have also been discussed between random error and the wavelength of the light source and between random error and the amplitude of the interference fringe.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Diffractive simultaneous bidirectional shearing interferometry using tailored spatially coherent light

Measurements of wavefront deformations can be carried out with the help of lateral shearing interferometers. Here the focus is on a setup providing two shears along orthogonal directions simultaneously to generate the data needed for a reconstruction. We describe a diffractive solution using Ronchi phase gratings with a suppressed zeroth order for both the doubling of the wavefront under test and the bidirectional shearing unit. A series arrangement of the gratings offers an on-axis geometry, which minimizes the systematic errors of the test. For illumination, an extended incoherent monochromatic light source is used. High-contrast fringes can be obtained by tailoring the degree of coherence via a periodic intensity distribution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Slope measurement of bent plates using double grating shearing interferometry

A grating-based shearing interferometeric setup for slope measurement of bent plates has been proposed. The specimen under test is illuminated by a collimated beam from the laser. Light reflected from the specimen passes through two identical holographic gratings placed in tandem. The grating frequency has been so chosen that the diffracted orders from each grating are separated out distinctly. Two first-order beams diffracted from each of the gratings superpose in space. In the resulting interferogram, the fringes due to slope information of the object are visualized. Mathematical formulation for experimental determination of slope values has been undertaken. Validation of the experimental results with theoretical predictions in case of cantilever beam provides good correlation. The main advantage of the technique has been the realization of very compact geometry without the need for spatial filtering arrangement commonly associated with the grating-based techniques used to date.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interpretation of dark-field contrast and particle-size selectivity in grating interferometers

In grating-based x-ray phase sensitive imaging, dark-field contrast refers to the extinction of the interference fringes due to small-angle scattering. For configurations where the sample is placed before the beamsplitter grating, the dark-field contrast has been quantified with theoretical wave propagation models. Yet when the grating is placed before the sample, the dark-field contrast has only been modeled in the geometric optics regime. Here we attempt to quantify the dark-field effect in the grating-before-sample geometry with first-principle wave calculations and understand the associated particle-size selectivity. We obtain an expression for the dark-field effect in terms of the sample material's complex refractive index, which can be verified experimentally without fitting parameters. A dark-field computed tomography experiment shows that the particle-size selectivity can be used to differentiate materials of identical x-ray absorption.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adaptive frequency comb illumination for interferometry in the case of nested two-beam cavities

The homogeneity test of glass plates in a Fizeau interferometer is hampered by the superposition of multiple interference signals coming from the surfaces of the glass plate as well as the empty Fizeau cavity. To evaluate interferograms resulting from such nested cavities, various approaches such as the use of broadband light sources have been applied. In this paper, we propose an adaptive frequency comb interferometer to accomplish the cavity selection. An adjustable Fabry-Perot resonator is used to generate a variable frequency comb that can be matched to the length of the desired cavity. Owing to its flexibility, the number of measurements needed for the homogeneity test can be reduced to four. Furthermore, compared to approaches using a two-beam interferometer as a filter for the broadband light source, the visibility of the fringe system is considerably higher if a Fabry-Perot filter is applied.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Talbot–Lau x-ray deflectometry phase-retrieval methods for electron density diagnostics in high-energy density experiments

Talbot–Lau x-ray interferometry uses incoherent x-ray sources to measure refraction index changes in matter. These measurements can provide accurate electron density mapping through phase retrieval. An adaptation of the interferometer has been developed in order to meet the specific requirements of high-energy density experiments. This adaptation is known as a moiré deflectometer, which allows for single-shot capabilities in the form of interferometric fringe patterns. The moiré x-ray deflectometry technique requires a set of object and reference images in order to provide electron density maps, which can be costly in the high-energy density environment. In particular, synthetic reference phase images obtained ex situ through a phase-scan procedure, can provide a feasible solution. To test this procedure, an object phasemap was retrieved from a single-shot moiré image obtained from a plasma-produced x-ray source. A reference phase map was then obtained from phase-stepping measurements using a continuous x-ray tube source in a small laboratory setting. Ultimately, the two phase maps were used to retrieve an electron density map. A comparison of the moiré and phase-stepping phase-retrieval methods was performed to evaluate single-exposure plasma electron density mapping for high-energy density and other transient plasma experiments. It was found that a combination of phase-retrieval methods can deliver accurate refraction angle mapping. Once x-ray backlighter quality is optimized, the ex situ method is expected to deliver electron density mapping with improved resolution. The steps necessary for improved diagnostic performance are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Trace-gas Spectroscopy of Methane on a Silicon Photonic Chip

Recent advances in hybrid integrated silicon photonic (SiPh) technologies are enabling the migration of conventional free-space optical spectroscopic sensors onto a compact on-chip platform [1-3]. In addition to the small spatial footprint and power efficiency, we envision such sensors to be scalably manufactured using existing CMOS-compatible foundry processes, thus providing disruptive SWaP-C (size, weight, power, and cost) benefits in contrast to commercially available optical sensors. Initial demonstration of evanescent TDLAS (tunable diode laser absorption spectroscopy) of methane (CH4) on a passive SiPh waveguide has indicated minimum fractional absorption of (αL)min = 3.3×10-5 Hz-1/2, which is on-par with state-of-art open-path TDLAS sensor systems [4]. Given the general recent movement toward cleaner fuels, CH4 fugitive emissions monitoring is of significant interest given the extremely high radiative forcing potential [5]. For a nominal waveguide length of 30 cm with Γ = 25 % evanescent exposure, this corresponds to ~ 10 ppmv detection sensitivity at 1 s integration time, and further sensitivity enhancement is expected with even longer waveguides, as the laser RIN typically dominates our measurements at nominal waveguide lengths. Despite the excellent sensitivities for short-term integration periods, long-term measurements (> 10 s) are potentially limited on a silicon platform due to the high material thermo-optic coefficient, resulting in significant susceptibility of Fabry-Perot etalons to drift in the presence of even small (~ 1 mK) thermal fluctuations. To this end, customized spectral fitting algorithms have played a significant role in both fringe drift mitigation and peak detection fidelity (e.g. in the presence of a passing CH4 plume), which are crucial for enhancing long-term stability without the need for frequent sensor recalibration. A variety of spectral algorithms have been designed for this purpose, and details will be presented at the meeting.

03 NATURAL GAS↗

Single-pulse interference caused by temporal reflection at moving refractive-index boundaries

Here, we show numerically and analytically that temporal reflections from a moving refractive-index boundary act as an analog of Lloyd’s mirror, allowing a single pulse to produce interference fringes in time as it propagates inside a dispersive medium. This interference can be viewed as the pulse interfering with a virtual pulse that is identical to the first, except for a π-phase shift. Furthermore, if a second moving refractive-index boundary is added to create the analog of an optical waveguide, a single pulse can be self-imaged or made to produce two or more pulses by adjusting the propagation length in a process similar to the Talbot effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Continuously active interferometer stabilization and control for time-bin entanglement distribution

In this study, we describe a new method enabling continuous stabilization and fine-level phase control of time-bin entanglement interferometers. Using this technique we demonstrate entangled photon transmission through 50 km of standard single-mode fiber. This technique reuses the entangled-pair generation pump which is co-propagated with the transmitted entangled photons. In addition, the co-propagating pump adds minimal noise to the entangled photons which are characterized by measuring a two-photon interference fringe.

74 ATOMIC AND MOLECULAR PHYSICS↗

A Sagnac Fourier spectrometer

A spectrometer based on a Sagnac interferometer, where one of the mirrors is replaced by a transmission grating, is introduced. Since the action of a transmission grating is reversible, both directions experience the same diffraction at a given wavelength. At the output, the crossed wavefronts are imaged onto a camera, where their Fizeau fringe pattern is recorded. Each spectral element produces a unique spatial frequency, hence the Fourier transform of the recorded interferogram contains the spectrum. Since the grating is tuned to place zero spatial frequency at a selected wavelength, the adjoining spectrum is heterodyned with respect to this wavelength. This spectrum can then be discriminated at a high spectral resolution from relatively low spatial frequencies. The spectrometer can be designed without moving parts for a relatively narrow spectral range or with a rotatable grating. As a result, the latter version bears the potential to be calibrated without a calibrated light source.

47 OTHER INSTRUMENTATION↗