Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

MCNP Analysis fo the Aqua-SETH Experiment in TREAT

The versatile Transient Reactor Test (TREAT) Facility’s capability to deliver customized transient nuclear power excursions gives researchers and developers a multitude of specialized testing options. In conjunction with reactorprescribed delivery of neutron flux, experiment design requires specimen packaging to meet TREAT safety containment requirements and experimenter test objectives. These objectives may range from the very simple separate effects tests (generally dry capsule) to the more complex integral scale testing wherein prototypic boundary or specimen reactor environment conditions are created. The historic MARK-III sodium flow loop that achieved thermalhydraulic prototypic test conditions serves as an example of the more complex experiment design package.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantification of Wellbore Leakage Risk Using Non-destructive Borehole Logging Techniques

Well integrity is important at all potential CCS locations and may play a crucial role establishing leakage risk in areas where there is a high density of existing wells that could be impacted by the storage operations including depleted petroleum fields where EOR or CCS will occur. To address a need for risk quantification methods that can be directly applied to individual wells using borehole logging tools a study was conducted using data from five wells in Wyoming. The objectives of the study were: Objective 1: Develop methods to establish the baseline flow parameters (porosity and permeability or mobility) from individual measurements of the material properties and defects in a well. Objective 2: Develop a correlation between field flow-property data and cement logs that can be used to establish the flow-properties of well materials and well features using cement mapping tools. Objective 3: Establish a method that uses the flow-property model (Objective 2) to analyze the statistical uncertainties associated with individual well leakage that can provide basis for uncertainty in risk calculations. The project objectives were met through the logging of five wells in Carbon and Natrona County Wyoming to collect data that was used to estimate individual and average well flow properties and model the results using ultrasonic data collected during the logging. Three of the five wells provided data on point and average flow properties for well annuli. Data from the other two wells were used to create models of cement permeability and test whether information collected in one well could be used to characterize another well. The results of the in-situ point measurements were confirmed by the lab measurements sidewall cores collected near the same depths Objective 1 was met using the data collected through logging, testing, and sampling. The methods were developed that can establish baseline flow parameters of wells by both point and average test methods. The methods to estimate the flow properties modeling of point pressure tests, modeling of vertical interference tests, and laboratory measurement of cased-hole sidewall cores The wells were in sufficiently good shape to allow the development of the characterization methods while still having enough defects to study differences in results as they relate to well integrity. Samples and tests analyzed from three of five wells studied in showed the cements were largely intact and had not degraded from exposure native brines. Log results taken in conjunction with the core measurements indicate that interfaces and/or problems with cement placement due to eccentering provide preferential flow paths for fluids, which can increase the effective permeability of the barrier several orders of magnitude above the permeability of intact cement. The results of the maps created using logging tools indicating that the cement condition and bond are generally good identify a need for more research to understand how logs can be used to predicteffective well permeabilities such as those measured by the VITs in this study.

42 ENGINEERING↗

On seasonal and semi-annual approach for flood frequency analysis

As a supplementary method to the conventional flood frequency analysis based on annual peak flows, we propose an approach in this paper to infer the flood frequency distribution on quarterly and semi-annual time scale, which are then converted to annual time scale to obtain the floods corresponding to return periods in unit of year. Two criteria for test of data independence, namely, minimum 7 and 15-day interval between two consecutive peak flows, are tested. The proposed approach was applied to Des Moines River at Fort Dodge, Iowa, USA using its 62 years of observation daily flows. The results show that the estimated floods for given return periods from quarter-annual data series are in general higher than the corresponding estimated floods from semi-annual data series, which is further larger than estimated floods from annual peak flows. In conclusion, the floods estimated from semi-annual data series agree well with the results of previous US Geological Survey study.

54 ENVIRONMENTAL SCIENCES↗

Portable unit for metabolic analysis

A portable unit for metabolic analysis includes a manifold in fluid communication with a mouth of a test subject. A conduit extends from the manifold and defines a flow channel through which the breaths of the test subject travels. A carbon dioxide sensor is attached to the conduit. The carbon dioxide sensor includes an intermediate support housing enclosing a volume disposed along the flow channel to define a first part of the flow channel, an inner support housing attached to a first side of the intermediate support housing, a plurality of IR LEDs mounted to an interior surface of the inner support housing, an outer support housing attached to a second side of the intermediate support housing, and a photodetector attached to the outer support housing. The photodetector faces the flow channel and receives IR radiation emitted by the plurality of LEDs.

Dietrich, Daniel L.↗

HERO CarbonSAFE Phase 2 Project in the Columbia River Basalt Group

The Hermiston, Oregon Basalt CarbonSAFE Phase II project (HERO CarbonSAFE) seeks to accelerate the deployment of commercial carbon dioxide (CO2) storage projects in basaltic rocks. Basalt CO2 storage has several advantages to conventional saline storage reservoirs including 1. The potential for rapid mineralization of CO2, 2. Associated decreases in pressure and CO2 migration risks, 3. Reduced long-term monitoring requirements with respect to plume tracking, 4. Widespread geographic distribution and, 5. Large storage potential due to thickness, porosity, and CO2 interactions with basalt. And for locations such as the Pacific Northwest, Hawaii, Iceland, India and Japan, basalts may offer the only economically feasible option for local CO2 storage. However, there are limited field-scale assessments of CO2 storage in basalt, and current carbon capture utilization and storage (CCUS) permitting and regulatory frameworks were developed for conventional saline reservoirs. HERO CarbonSAFE is designed to address research gaps and uncertainties associated with basalt storage. Specifically, the project will assess the feasibility of CO2 injection in the deep layered basalts, long-term storage (mineralization), practical approaches for large-scale implementation (50+ million metric tons of CO2 over 30 years), lithology-specific risks, and the technoeconomic potential for CO2 storage in basalts. The HERO CarbonSAFE project will assess feasibility of developing a commercial-scale (50+ million metric tons of CO2) geological storage complex within the Columbia River Basalt Group (CRBG), a layered continental flood basalt complex that underlies Calpine’s natural gas-fired Hermiston Power Project (HPP) in Hermiston, OR (Figure 1). Under this 2-year CarbonSAFE Phase II project, the HERO team will conduct a data acquisition campaign that includes drilling a stratigraphic well to a total depth of ~1,500 m into the thick layered basalts proximal to HPP. A comprehensive well logging and hydrologic testing program will be augmented with new core collected from flow zones and sealing units, and comprehensive laboratory testing to help refine the kinetic rates of mineralization. The newly acquired information will be integrated with existing data from regional wells to correlate basalt injection zone properties to develop storage hub/commercial-scale models. Using these models, the project team will evaluate injection scenarios to define the technical and economic potential for storing a minimum of 50 million metric tons of CO2 over a 30-year period, along with a robust sensitivity analysis on key parameters governing reservoir viability for sustainable injection over a commercial project lifetime. Specific technical objectives of HERO are: (1) assessing the reservoir response of a series of stacked layered reservoir flowtop sequences occurring in this area of the CRBG to commercial-scale injection volumes; (2) extending prior efforts by the project team to characterize the deep layered basalts encountered in regional studies, to leverage prior investments by U.S. Department of Energy’s (DOE) Carbon Storage program; (3) leveraging DOE’s mineralization characterization efforts to advance model parametrization for commercial scale injection of CO2 in basalts; (4) conducting risk assessments associated with scaling up to commercial storage hub injection goals, while validating DOE’s National Risk Assessment Partnership (NRAP) tools, to identify potential constraints that would prevent the CRBG from serving as a commercial-scale storage complex; (5) developing mitigation plans to address identified risks; (6) developing a commercial-scale injection and monitoring, verification and accounting (MVA) strategy; (7) utilizing computational models to define and minimize, if possible, the Area of Review (AoR) under Class VI regulations; and (8) developing a robust CO2 management strategy for CRBG that also considers a regional source/sink approach that is responsive to stakeholder needs and industrial demand. Specific institutional objectives are: (1) identifying and developing plans to mitigate the nontechnical challenges associated with the build-out of a commercial-scale storage complex within the CRBG with integrated CO2 sources; (2) implementing the community outreach plan; (3) conducting regulatory research, including a survey of issues related to pore space ownership, MVA and long-term assurance of mineralization-based storage, to support an eventual application for a UIC Class VI permit; (4) advancing the project’s plan for CO2 liability management; and (5) continuing to refine and update the project’s economic model. The final objective is the preparation of a comprehensive Site Characterization Plan that draws upon the technical and institutional feasibility assessments to prepare the project for future commercialization efforts.

58 GEOSCIENCES↗

Modeling Multiphase Effects in CO 2 Compressors at Subcritical Inlet Conditions

An advanced numerical framework to model CO 2 compressors over a wide range of subcritical conditions is presented in this paper. Thermodynamic and transport properties are obtained through a table look-up procedure with specialized features for subcritical conditions. Phase change is triggered by the difference between the local values of pressure and saturation pressure, and both vaporization and condensation can be modeled. Rigorous validation of the framework is presented for condensation in high pressure CO 2 using test data in a De Laval nozzle. The comparisons between computations and test data include: condensation onset locations, Wilson line, and nozzle pressure profiles as a function of inlet pressures. The framework is applied to the Sandia compressor that has been modeled over broad range of conditions spanning the saturation dome including: near critical inlet conditions (305.4 K, and 7.843 MPa), pure liquid inlet conditions (at 295 K), pure vapor inlet conditions (at 302 K), and two-phase inlet conditions (at 290 K). Multiphase effects ranging from cavitation at the liquid line to condensation at the vapor line have been simulated. Here, the role of real fluid effects in enhancing multiphase effects at elevated temperatures closer to the critical point has been identified. The performance of the compressor has been compared with test data; the computational fluid dynamics (CFD) results also show that the head-flow coefficient curve collapses with relatively minor scatter, similar to the test data, when the flow coefficient is defined on the impeller exit meridional velocity.

14 SOLAR ENERGY↗

Absorber Cooling Circuits Dynamic Pressure Study

The flow rates through the flange/stick absorber cooling circuit and the crotch absorber cooling circuit should not exceed 2 GPM. The purpose of this document is to define the scope and present the results of the NSLSII absorber circuit water cooling pressure test. This report also provides flow capacities for each type of absorber cooling circuit in accordance with the required header pressure differential and other cooling system design parameters.

43 PARTICLE ACCELERATORS↗

Benchmark Specifications for Select Experiments Conducted at the Kansas State University Gallium Thermal-hydraulic Experiment Facility

The Department of Energy (DOE) – Nuclear Energy University Programs (NEUP) supported the creation and operation of the Gallium Thermal-hydraulic Experiment (GaTE) facility at Kansas State University (KSU) as part of a larger effort to understand thermal stratification behavior in liquid-metal-cooled reactors. GaTE was designed to simulate transients in a reactor plenum that are known to cause thermal stratification. High-reliability and high-resolution measurements describing stratification behavior in the coolant were collected for use as experimental benchmarks in validation efforts for computational models. The results of these tests contribute to a greater understanding of thermal stratification behavior of liquid metal under various configurations and operating conditions. This report provides a complete description of the benchmark problem, including all necessary details and description of a set of four forced flow and four natural circulation tests and measured data for comparison with model results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Performance and wake flow characterization of a 1:8.7-scale reference USDOE MHKF1 hydrokinetic turbine to establish a verification and validation test database

As hydrokinetic turbine technologies continue to advance towards commercialization, public datasets on the performance characteristics for these devices and their flow field effects are invaluable to advance our understanding of these technologies and to validate analytical and numerical models. The Applied Research Laboratory at The Pennsylvania State University (ARL Penn State) collaborated with Sandia National Laboratories and the University of California at Davis to design, fabricate (at a 1:8.7 scale), and experimentally test a novel hydrokinetic turbine rotor design to provide an open platform and dataset for further study and development. The water tunnel test of this three-bladed, horizontal-axis rotor recorded power production, blade loading, the near-wake flow, cavitation effects, and noise generation. These state-of-the-art measurements demonstrate much of the complex physics associated with the flow through an unducted, horizontal-axis turbine, and they elucidate the performance characteristics and flow field effects at an unprecedented fidelity, accuracy and resolution. Measurements of powering coefficients (power, torque and thrust) as a function of tip-speed-ratio were performed. The dataset also includes unsteady measurements of driveshaft loading, blade strain, tower pressures, and radiated noise. Detailed flow mapping using laser Doppler velocimetry, and planar and stereo particle image velocimetry includes measurements of mean velocity and Reynolds stresses. Although the wake measurements are limited to less than half a diameter, they reveal the complex flow patterns in the near-wake structure of the rotor. The full database, available at the United States Department of Energy’s marine and hydrokinetic data repository, includes tunnel and model Computer Aided Design geometry files and inflow data sufficient for a “Model-the-Test” computational Verification and Validation study.

13 HYDRO ENERGY↗

Density Effects on Lock Exchange Flow During a DCC

The High Temperature Test Facility (HTTF) is a scaled, electric model at Oregon State University (OSU) of the Modular High Temperature Gas Reactor (MHTGR) by General Atomics. There are a few major differences between the design and the OSU facility. In the HTTF the reactor pressure vessel and the reactor cavity are in two separate tanks connected by a crossover duct similar to the crossover duct that would be seen between the reactor core and the steam generator in the MHTGR. This feature allows for the facility to open two main break valves simulating a Double-Ended Guillotine Break (DEGB) of the cross over duct, synonymous to a crossover duct break in the MHTGR. The density gradient driven flow phenomena in the HTTF duct can then be studied further. This break would cause a depressurization of the reactor and a loss of flow. It is called the Depressurized Loss of Forced Convection Accident (D-LOFC), also known as the Depressurized Conduction Cool-Down Event for High Temperature Gas Reactors (HTGRs) because heat removal is by conduction through the core and radiation out of the vessel. The HTTF was built and scaled to maintain the highest accuracy for the DCC. Prototypical temperatures with an inlet temperature of 259 deg. C and an outlet temperature of 687 deg. C are maintained in the HTTF. The temperature profile is also maintained in the smaller volume by using a ceramic core. The HTTF uses graphite heaters because the resistive heat produced does not change significantly with temperature . In order to produce a facility of similar temperatures within the allotted budget, sacrifices had to be made in other areas. The HTTF is scaled one-fourth in diameter, one-fourth in height and one-eighth in pressure of the MHTGR. There are also a few limitations for the HTTF. While in the MHTGR, the cavity is filled with air, the HTTF uses highly pure Nitrogen and does not have the ability to simulate a full depressurization. The DCC event is traditionally comprised of multiple stages: depressurization, molecular diffusion and natural circulation. However, this traditional interpretation ignores lock exchange flow which will occur immediately following depressurization and could have significant consequences in the reactor. It was found that the traditional model underestimates the amount of air ingress by at least 660 times according to Oh and Kim in their theoretical research of air ingress. Molecular diffusion also decreases with stratification. Any model that specifies the gases are stratified has further underestimated the air ingress of the DCC event. In addition, molecular diffusion is a much slower process, allowing the reactor to shut down and cool off considerably from operating temperatures. Thus, understanding lock exchange flow, the air ingress concentrations and the time scale is critical to MHTGR research and licensing. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Discrete fracture network model benchmarks developed and applied in a DECOVALEX-2023 repository performance assessment study

This study presents newly developed benchmarks for modeling flow and transport within discrete fracture networks (DFNs) and useful methods for analyzing the results. The new benchmarks are designed to test modeling approaches for use in probabilistic performance assessment models of deep geologic repositories in fractured rock. The benchmarks simulate flow and transport through a 1 km 3 block of fractured rock. The first simulates migration of a short pulse of tracer through a simple network of four intersecting fractures. The second adds 1089 stochastically generated fractures. The third changes the pulse to a continuous point source. Evaluation of model performance relies on moment analysis and comparison of the results of different models. The expected nondimensional first moment of the conservative tracer for each benchmark is 1. The benchmarks were simulated by teams from Canada, Czechia, Germany, Korea, Sweden, Taiwan, and the United States as part of a DECOVALEX-2023 study (decovalex.org). The teams used various approaches, including explicit DFN modeling, DFN upscaling to an equivalent continuous porous medium (ECPM), and a combination of both methods. Transport mechanisms are modeled using either the advection-dispersion equation or particle tracking. Results demonstrate strong agreement among the models in breakthrough behavior up to the 75th percentile. Significant deviations in first moments and well-clustered outputs led to the identification of inaccuracies in several models. Such findings exemplify the benefit of exercising these benchmarks and using the presented methods to test DFN flow and transport models.

Benchmark↗

Time reversal symmetry breaking and odd viscosity in active fluids: Green–Kubo and NEMD results

Active fluids, which are driven at the microscale by non-conservative forces, are known to exhibit novel transport phenomena due to the breaking of time reversal symmetry. Recently, Epstein and Mandadapu [arXiv:1907.10041 (2019)] obtained Green-Kubo relations for the full set of viscous coefficients governing isotropic chiral active fluids, including the so-called odd viscosity, invoking Onsager's regression hypothesis for the decay of fluctuations in active non-equilibrium steady states. In this Communication, we test these Green-Kubo relations using molecular dynamics simulations of a canonical model system consisting of actively torqued dumbbells. We find the resulting odd and shear viscosity values from the Green-Kubo relations to be in good agreement with values measured independently through non-equilibrium molecular dynamics flow simulations. This provides a test of the Green-Kubo relations and lends support to the application of the Onsager regression hypothesis in relation to viscous behaviors of active matter systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A flowing liquid lithium limiter for the Experimental Advanced Superconducting Tokamak

A program involving the extensive and systematic use of lithium (Li) as a “first,” or plasma-facing, surface in Tokamak fusion research devices located at Institute of Plasma Physics, Chinese Academy of Sciences, was started in 2009. Many remarkable results have been obtained by the application of Li coatings in Experimental Advanced Superconducting Tokamak (EAST) and liquid Li limiters in the HT-7 Tokamak—both located at the institute. In furtherance of the lithium program, a flowing liquid lithium (FLiLi) limiter system has been designed and manufactured for EAST. The design of the FLiLi limiter is based on the concept of a thin flowing film which was previously tested in HT-7. Exploiting the capabilities of the existing material and plasma evaluation system on EAST, the limiter will be pre-wetted with Li and mechanically translated to the edge of EAST during plasma discharges. The limiter will employ a novel electro-magnetic pump which is designed to drive liquid Li flow from a collector at the bottom of limiter into a distributor at its top, and thus supply a continuously flowing liquid Li film to the wetted plasma-facing surface. This paper focuses on the major design elements of the FLiLi limiter. In addition, a simulation of incoming heat flux has shown that the distribution of heat flux on the limiter surface is acceptable for a future test of power extraction on EAST.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic Uniaxial Compression of HSLA-65 Steel at Elevated Temperatures

Here, the dynamic response of a high-strength, low alloy Grade 65 (HSLA-65) steel, used by the United States Navy for ship hull construction, is investigated under dynamic uniaxial compression at temperatures ranging from room temperature to 1000 °C using a novel elevated temperature split-Hopkinson pressure bar. These experiments are designed to probe the dynamic response of HSLA-65 steel in its single α-ferrite phase, mixed α + γ-austenite phase, and the single γ-austenite phase, as a function of temperature. The investigation is conducted at two different average strain rates—1450 and 2100/s. The experimental results indicate that at test temperatures in the range from room temperature to lower than 600 °C, i.e. prior to the development of the mixed α + γ phase, a net softening in flow strength is observed at all levels of plastic strain with increase in test temperatures. As the test temperatures are increased, the rate of this strain softening with temperature is observed to decrease, and at 600 °C the trend reverses itself resulting in an increase in flow stress at all strains tested. This increase in flow stress is understood be due to dynamic strain aging, where solute atoms play a distinctive role in hindering dislocation motion. At 800 °C, a (sharp) drop in the flow stress, equivalent to one-half of its value at room temperature, is observed. As the test temperature are increased to 900 and 1000 °C, further drop in flow stress are observed at all plastic strain levels. In addition, strain hardening in flow stress is observed at all test temperatures up to 600 °C; beyond 800 °C the rate of strain hardening isobserved to decrease, with strain softening becoming dominant at temperatures of 900 °C and higher. Moreover, comparing the high strain rate stress versus strain data gathered on HSLA 65 in the current investigation with those available in the literature at quasi-static strain rates, strain-rate hardening can be inferred. The flow stress increases from 700 MPa at 8 × 10 -4 /s to 950 MPa at 1450/s and then to 1000 MPa at 2100/s at a strain of 0.1. Finally, optical microscopy is used to understand evolution of microstructure in the posttest samples at the various test temperatures employed in the present study.

36 MATERIALS SCIENCE↗

Printability of alloys for additive manufacturing

Although additive manufacturing (AM), or three dimensional (3D) printing, provides significant advantages over existing manufacturing techniques, metallic parts produced by AM are susceptible to distortion, lack of fusion defects and compositional changes. Here we show that the printability, or the ability of an alloy to avoid these defects, can be examined by developing and testing appropriate theories. A theoretical scaling analysis is used to test vulnerability of various alloys to thermal distortion. A theoretical kinetic model is used to examine predisposition of different alloys to AM induced compositional changes. A well-tested numerical heat transfer and fluid flow model is used to compare susceptibilities of various alloys to lack of fusion defects. These results are tested and validated with independent experimental data. Here, the findings presented in this paper are aimed at achieving distortion free, compositionally sound and well bonded metallic parts.

36 MATERIALS SCIENCE↗

Validation of CTF Droplet Entrainment and Annular/Mist Closure Models using Riso Steam/Water Experiments

This document summarizes the work to validate the droplet entrainment and de-entrainment models, as well as two-phase closure models in the CTF code [1] by comparison with experimental data obtained at Risø National Laboratory [2]. CTF is the modernized version of the subchannel code, COBRA-TF [3], being jointly developed by Oak Ridge National Laboratory and North Carolina State University for applications in the Consortium for Advanced Simulation of Light Water Reactors (CASL). The Risø data included a series of more than 250 steam/water experiments that were performed in both tube and annulus geometries over a range of various pressures and outlet qualities. Experimental conditions wereset so that the majority of cases were in the annular/mist flow regime. Measurements included liquid film flow rate, droplet flow rate, film thickness, and two-phase pressure drop. CTF was used to model 180 of the tubular geometry cases, matching experimental geometry, outlet pressure, and outlet flow quality to experimental values. CTF results were compared to the experimental data at the outlet of the test section in terms of vapor flow fractions, and entrained liquid flow fractions, and pressure drop per unit length.

Wysocki, Aaron↗

Experimental Study for Two Phase Flow Instability in the PCHE Type Steam Generator in SMR

Conventional U-tube type heat exchangers have some limitations when applied to Small Modular Reactor (SMRs). In particular, the size of steam generators is important in the SMR, as it greatly affects the size, and thus the cost, of the reactor vessel.. Therefore, the circuit heat exchanger (PCHE) is suggested as an alternative. PCHE, a compact type heat exchanger manufactured by HEATRIC, has several advantages such as the reduced size, wide operation range until 900? and 900 bar and high power density due to the large heat transfer area over volume ratio. Recently, it is newly suggested as an application of a steam generator. MIT and KAIST have already conceptually suggested PCHE as a steam generator. Under boiling condition, flow instability is one of the critical issues-resulting in unstable mass flow rate, sudden temperature change and system control failure. According to the flow mechanism, there are various types of instabilities in the heat exchanger and each flow tendency is different. Typical examples are Ledinegg instability of the static instability and pressure-drop oscillation and density-wave oscillation of the dynamic instability. The characteristic of Ledinegg instability is that the flow under unstable condition changes into the stable flow. The characteristic of dynamic instability is that the flow fluctuates continuously. Pressure-drop oscillation has the period of tens of seconds and the system pressure also highly oscillates with the period of flow instability. In comparison, the density-wave oscillation has the period of few seconds and the system pressure is relatively stable. Previous studies on flow instability are focused on the single channel flow and helical tube type heat exchanger. There has been very limited experimental research on flow instability using PCHE. In KAIST, the test facility was constructed to study the thermal hydraulics in PCHE. The objectives of our test facility are: (1) to identify the occurrence of instability under two phase and super-heated steam flow in PCHE, and (2) to examine whether it can operate normally using throttling effect. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Validation of CTF Droplet Entrainment and Annular/Mist Closure Models using Riso Steam/Water Experiments

This document summarizes the work to validate the droplet entrainment and de-entrainment models, as well as two-phase closure models in the CTF (Coolant Boiling in Rod Arrays - Two Fluids) code by comparison with experimental data obtained at Risoe National Laboratory. CTF is the modernized version of the subchannel code, COBRA-TF, being jointly developed by Oak Ridge National Laboratory and North Carolina State University for applications in the Consortium for Advanced Simulation of Light Water Reactors (CASL). The Risoe data included a series of more than 250 steam/water experiments that were performed in both tube and annulus geometries over a range of various pressures and outlet qualities. Experimental conditions were set so that the majority of cases was in the annular/mist flow regime. Measurements included liquid film flow rate, droplet flow rate, film thickness, and two-phase pressure drop. CTF was used to model 180 of the tubular geometry cases, matching experimental geometry, outlet pressure, and outlet flow quality to experimental values. CTF results were compared to the experimental data at the outlet of the test section in terms of vapor flow fractions, and entrained liquid flow fractions, and pressure drop per unit length.

42 ENGINEERING↗