Space Launch System Base Heating Test: Environments and Base Flow Physics
No abstract available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
No abstract available
Explore the source record for details and available documents.
Abstract Not Provided
Explore the source record for details and available documents.
No abstract prepared.
Supported by an award from the Solar Technology Office, US Department of Energy, GE Aerospace Research in collaboration with Heliogen Holdings Inc, is engaged in the development of ultra-High Operating Temperature SiC-matrix Solar Thermal Air Receiver (HOTSSTAR). We report the results of our study of the effective heat transfer characteristic of several candidate structure motifs, or feature geometries, made of SiC via additive manufacturing in a simulative laboratory test. The SiC structure motifs studied include different permutations of three-dimensional periodic lattices and defined shapes. The solar-thermal simulating laboratory test setup is constructed using a 4kW CO2 laser system with beam shaping optics to apply radiative heating power on one face of 2”-diameter cylindrical feature specimens representing the structure motifs of interest for receiver element design. Using the test setup, simulative test conditions representative of a concentrated solar flux of up to ~2000 suns could be achieved in the lab tests under varying air flow through the test structure. A numerical analysis scheme is developed to extract an effective or compound heat transfer coefficient representative of the test structure under steady-state heat flow conditions.
A new capability to test active flow control concepts and propulsion simulations at high Reynolds numbers in the National Transonic Facility at the NASA Langley Research Center is being developed. This technique is focused on the use of semi-span models due to their increased model size and relative ease of routing high-pressure air to the model. A new dual flow-path high-pressure air delivery station has been designed, along with a new high performance transonic sem -si pan wing model. The modular wind tunnel model is designed for testing circulation control concepts at both transonic cruise and low-speed high-lift conditions. The ability of the model to test other active flow control techniques will be highlighted. In addition, a new higher capacity semi-span force and moment wind tunnel balance has been completed and calibrated to enable testing at transonic conditions.
This presentation discusses a field test of a DHW distribution system in an occupied townhome. It includes measured fixture flows and temperatures, a tested recirculation system, evaluated disaggregation of flow by measured temperatures, Aquacraft Trace Wizard analysis, and comparison.
The test results briefly described in this report were obtained on the three-dimensional 1:48 scale tunnel modeled on the design proposed by Messrs. D.S.M.A. Corporation. More particularly, while the test chamber dimensions were indeed scaled down in the ration of 1:48, including the contraction and the collector as well, the duct system itself leading to and from the chamber was adapted to suit laboratory conditions and space limitations. Earlier tests with the two-dimensional model showed that blowing mode was preferred as against the suction mode, hence all tests were performed with blowing only. At the exit of the contraction the maximum airspeed attained with the 1 HP blower unit was about 200 ft/sec. This airspeed may be increased in future if desired. The test results show that pressure recovery in the diffuser was about 34 percent due to the large blockage at its entrance. Velocity traverses taken across the diffuser entrance explain the reason for this blockage. Recirculation, studied with both, hot-wire anemometry and flow-visualization techniques, was largely affected by the design of the test chamber itself and the amount of vent-air admitted to the chamber. Vent-air helped to decrease the level of turbulence.
We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. Because the transducer is intended for immersion in a high temperature corrosive fluid, understanding of material degradation is crucial for estimation of transducer performance lifetime, and development of measurement interpretation algorithms. We conducted a preliminary computational investigation of relevant damage mechanisms of a stainless steel 316 cylindrical resonator in FLiBe salt. The two main damage mechanisms, creep and corrosion, were modeled using multiphysics COMSOL software. Degradation was modeled for a temperature range 500°C to 700°C. Coupling of the damage mechanisms was not considered. These models predict significant inelastic deformation at most temperatures due to creep, and qualitatively predict chromium depletion both along the liquid/solid interface and along the grain boundaries. An algorithmic approach for compensation of these degradation effects during fluid flow measurements will be developed in the future work. To validate sensor physics, we have performed proof-of-principle test of flow sensing in water. For this test, we have developed a cylindrical resonator for K-band, which was machined from brass. The cavity was excited through WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder. To increase the spectral signal visibility, we developed a signal processing method for baseline subtraction. A flow loop for proof-of-principle test of transducer performance in water was assembled. A commercial flow meter was installed in the loop for reference measurements. Cylindrical cavity was excited in the TE 011 mode with resonant frequency f ≈ 17.8GHz. Frequency shift of cavity spectral response was obtained by gradually increasing water flow rate from 0 to 60gpm. Corresponding monotonic increase of resonant frequency shift by several MHz was observed. Approximate figure of merit of sensitivity to flow rate is 100KHz/GPM. In addition, we have identified an existing liquid sodium experimental setup for demonstration of flow sensing in environment similar to that of an advanced reactor. The setup consists of a cylindrical vessel and center feed line, where transducer inserted through the lid will measure velocity of the impinging liquid jet. As a calibration experiment, we have assembled a water vessel with center feed with the same dimensions as those of the liquid sodium setup. We have also developed and insertion probe consisting of a 50cm brass waveguide enclosed in protective SS316 tube. Using the water loop, we have demonstrated feasibility of sensing the impinging liquid jet in the vessel.
A steady incompressible three-dimensional viscous flow analysis has been conducted for the Space Shuttle External Tank/Orbiter propellant feed line disconnect flapper valves with upstream elbows. The full Navier-Stokes code, INS3D, is modified to handle interior obstacles. Grids are generated by SVTGD3D code. Two dimensional initial grids in the flow cross section with and without the flappers are improved by elliptic smoothing to provide better orthogonality, clustering and smoothness to the three dimensional grid. The flow solver is tested for stability and convergence in the presence of interior flappers. An under-relaxation scheme has been incorporated to improve the solution stability. Important flow characteristics such as secondary flows, recirculation, vortex and wake regions, and separated flows are observed. Computed values for forces, moments, and pressure drop are in satisfactory agreement with water flow test data covering a maximum tube Reynolds number of 3.5 x 10(exp 6). The results will serve as a guide to improved design and enhanced testing of the disconnect.
A steady incompressible three-dimensional viscous flow analysis has been conducted for the Space Shuttle external tank/orbiter propellant feed line disconnect flapper valves with upstream elbows. The Navier-Stokes code, INS3D, is modified to handle interior obstacles and a simple turbulence model. The flow solver is tested for stability and convergence in the presence of interior flappers. An under-relaxation scheme has been incorporated to improve the solution stability. Important flow characteristics such as secondary flows, recirculation, vortex and wake regions, and separated flows are observed. Computed values for forces, moments, and pressure drop are in satisfactory agreement with water flow test data covering a maximum tube Reynolds number of 3.5 million. The predicted hydrodynamical stability of the flappers correlates well with the measurements.
Pure uranium hexafluoride (UF6) was injected into an argon confined, steady state, rf-heated plasma within a fused silica peripheral wall test chamber. Exploratory tests conducted using an 80 kW rf facility and different test chamber flow configurations permitted selection of the configuration demonstrating the best confinement characteristics and minimum uranium compound wall coating. The overall test results demonstrated applicable flow schemes and associated diagnostic techniques were developed for the fluid mechanical confinement and characterization of uranium within an rf plasma discharge when pure UF6 is injected for long test times into an argon-confined, high-temperature, high-pressure, rf-heated plasma.
Two-phase thermal management subsystems that take advantage of both the sensible and latent heat of a working fluid can potentially yield significant enhancements in overall performance by adopting heat transfer processes that are based on phase transition like boiling and condensation. Performance of terrestrial two-phase flow systems may be predictable because the hydrodynamic and body forces are understood, however, in microgravity, which is predominant during planetary space travel, forces that are masked by the strong body force on Earth (gravitational or buoyancy force) reappear with different magnitude and influence. The need arose for a facility that provides for two-phase flow with phase transition testing in microgravity. The Flow Boiling and Condensation Experiment (FBCE) is a facility that was launched to the International Space Station in August of 2021 and is in operation since February of 2022. This facility enables investigators to perform two-phase flow and phase transition research in flow boiling and condensation. Along with the test module that is experiment specific, the FBCE system consists of the fluid, avionics, and software subsystems. Currently two test modules, namely, the Flow Boiling Module (FBM) and the Condensation Module for Heat Transfer (CM-HT) are available. A third module, the Transfer Line test Module (TL) is being developed. The fluid subsystem conditions and delivers the fluid at the desired thermodynamic state to the test module. It consists of two fluid modules and a heater module that are connected by flex hoses for fluid circulation and by data and electrical cables for control and data acquisition. Two avionics modules acquire pressure and temperature data from various sensors in the flow loop. For FBM, a high-speed camera is available to acquire images of the boiling process. Experiments are operated autonomously by software and are based on an Experiment Parameters Master Table (EPMT) that is uploaded to ISS and is executed by the FBCE flight software. This presentation briefly introduces the objectives of FBCE and provides a system description of the experiment onboard of the ISS/Fluid Integrated Rack (FIR). Results of the test campaign carried out using the FBM are presented. Specifically, microgravity flow boiling of n-perfluorohexane (test fluid) is discussed with subcooled inlet conditions in a single-side-heated rectangular channel of dimensions 114.6-mm heated length, 2.5-mm heated width, and 5.0-mm height. Key operating parameters investigated are mass velocity (199.90 – 3200.13 kg/m2s), inlet subcooling (0.10 – 45.76°C), and inlet pressure (113.30 – 164.29 kPa). Image sequences acquired via high-speed-video are shown to elucidate the interfacial flow physics. The effects of various parameters on flow boiling heat transfer in microgravity, from the onset of boiling to the critical heat flux are discussed. Heat transfer results are presented in terms of flow boiling curves, streamwise profiles of wall temperature and heat transfer coefficient, and parametric trends of local and averaged heat transfer coefficient, and the critical heat flux.
This paper presents computational fluid dynamics simulations of the flow in the NASA Langley Research Center Transonic Dynamics Tunnel (TDT) with the airstream oscillator system (AOS) in operation. Test section flow angle can be modulated using sinusoidally oscillating vanes which are located in pairs within the contraction section of the tunnel circuit. A compilation of previously published experimental data for validation has been reviewed that contains hot-wire anemometer and fast-response probe data acquired in an empty test section with the vanes oscillating in-phase and out-of-phase. These experimental data have not previously been compared with computational results. The present results provide an opportunity for validation of the simulations of the sinusoidal AOS flow field in the TDT test section. Computed tunnel centerline, lateral and cross-section contour data of flow angle and vorticity show that resolving the vane tip vortex is critical to accurately predicting the test section center flow angle. The computed results show, as do the experimental data, what appears to be a resonance at higher frequencies. It is currently not known what is the cause of that resonance. Further refinement of the mesh is expected to improve the comparisons with experimental data
This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The series of tests performed measured air flow using a range of techniques and devices. The measured air flows were compared to reference air flow measurements using inline air flow meters built into the test apparatus. The experimental results showed that some devices had reasonable results (typical errors of 5 percent or less) but others had much bigger errors (up to 25 percent).
In the interest of accelerating waste treatment processing, the DOE has funded studies to better understand filtration with the goal of improving filter fluxes in existing cross-flow equipment. The Savannah River National Laboratory (SRNL) was included in those studies, with a focus on start-up techniques, filter cake development, the application of filter aids (cake forming solid precoats), and body feeds (flux enhancing polymers). This paper discusses the progress of those filter studies. Cross-flow filtration is a key process step in many operating and planned waste treatment facilities to separate undissolved solids from supernate slurries. This separation technology generally has the advantage of self-cleaning through the action of wall shear stress created by the flow of waste slurry through the filter tubes. However, the ability of filter wall self-cleaning depends on the slurry being filtered. Many of the alkaline radioactive wastes are extremely challenging to filtration, e.g., those containing compounds of aluminum and iron, which have particles whose size and morphology reduce permeability. Unfortunately, low filter flux can be a bottleneck in waste processing facilities such as the Savannah River Modular Caustic Side Solvent Extraction Unit and the Hanford Waste Treatment Plant. Any improvement to the filtration rate would lead directly to increased throughput of the entire process. To date increased rates are generally realized by either increasing the cross-flow filter axial flowrate, limited by pump capacity, or by increasing filter surface area, limited by space and increasing the required pump load. SRNL set up both dead-end and cross-flow filter tests to better understand filter performance based on filter media structure, flow conditions, filter cleaning, and several different types of filter aids and body feeds. Using non-radioactive simulated wastes, both chemically and physically similar to the actual radioactive wastes, the authors performed several tests to demonstrate increases in filter performance. With the proper use of filter flow conditions and filter enhancers, filter flow rates can be increased over rates currently realized today.