Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Experimental investigation of laser ablation of stone polycrystalline targets

We report the results of an experimental investigation of ablation of stone polycrystalline targets of complex multicomponent composition, which imitate the substance of asteroids. The targets were irradiated by nanosecond pulses of a neodymium laser at an energy density Φ{sub L} of up to 5 × 10{sup 4} J cm{sup −2}. The experiments demonstrated the existence of two ablation regimes, with the boundary between them lying at Φ{sub L} ≈ 4000 J cm{sup −2}. The regime change is characterised by a change in the form of the dependence of the surface mass density of removed target material on the laser energy density and by the appearance of a minimum in the dependence of specific energy of destruction on Φ{sub L}. This is supposedly related to the passage from a one-dimensional plasma plume expansion to the three-dimensional one and the corresponding decrease in the efficiency of energy transfer from the laser beam to the target due to a lowering of laser-produced plasma density. Our experiments also showed the existence of a maximum in impulse coupling coefficient C{sub m} as a function of laser energy density (C{sub m} ≈ 6.3 × 10{sup −5} N W{sup −1} for Φ{sub L} = Φ{sub opt} ≈ 25 J cm{sup −2}). Maxima were also recorded in the dependences of the ablation efficiency and average ablation flow velocity on Φ{sub L}. For Φ{sub L} > Φ{sub opt}, the decrease in the function C{sub m}(Φ{sub L}) turns out to be much steeper than for metals and polymer materials. The difference is supposedly due to the lower strength and lower plasticity of the polycrystalline stone targets. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A fluctuational electrodynamics model for the optimization of light-extraction efficiency in thin-film light-emitting diodes

The rapid development of thin film light-emitting diodes (LEDs) has enabled the enhancement of the light extraction beyond geometrical limits but more quantitative understanding of the underlying optical processes is required to fully optimize the extraction. We present first-principle calculations of the light extraction efficiency and optical energy flow in thin-film LEDs. The presented model generalizes the methods of fluctuational electrodynamics to excited semiconductors and simultaneously accounts for wave optical effects, e.g., interference and near-field coupling as well as the internal absorption of the light-emitting material in determining the rate of light emission and internal dissipation in the optical cavity formed by a planar LED. The calculations show that in structures with a metallic mirror, the emissivity of the active region can approach unity at selected wavelengths, even when the nominal emissivity of the active region is only moderate. However, the results also show that near-field coupling of emission from the active region to the mirror can provide a substantial non-radiative loss channel reducing the maximum light extraction efficiency to 0.67 in our example setup. These losses can be partly compensated by the efficient photon recycling enabled by thick active regions that quench emission to confined modes and thereby reduce parasitic absorption.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance of copper chloride-impregnated sorbents on mercury vapor control in an entrained-flow reactor system

An entrained-flow system has been designed and constructed to simulate in-flight mercury (Hg) capture by sorbent injection in ducts of coal-fired utility plants. The test conditions of 1.2-sec residence time, 140{degree}C gas temperature, 6.7 m/sec (22 ft/sec) gas velocity, and 0-0.24 g/m{sup 3} (0-15 lbs of sorbent per 1 million actual cubic feet of flue gas sorbent injection rates were chosen to simulate conditions in the ducts. Four kinds of sorbents were used in this study. Darco Hg-LH (lignite-based) served as a benchmark sorbent with which Hg control capability of other sorbents could be compared. Also, Darco-FGD (lignite-based) was used as a representative raw activated carbon sorbent. Two different copper chloride-impregnated sorbents were developed in the laboratory and tested in the entrained-flow system to examine the possibility of using these sorbents at coal-fired power plants. The test results showed that one of the copper chloride sorbents has remarkable elemental mercury (Hg{sup 0}) oxidation capability, and the other sorbent demonstrated a better performance in Hg removal than Darco Hg-LH. 13 refs., 4 figs., 3 tabs.

01 COAL, LIGNITE, AND PEAT↗

High-resolution shock-capturing schemes for inviscid and viscous hypersonic flows

The development of robust, accurate, and efficient implicit shock-capturing schemes for multidimensional compressible Navier-Stokes equations in the hypersonic and real gas flow regimes is presently undertaken by extending a class of implicit total variation-diminishing (TVD) schemes suitable for transonic and supersonic, multidimensional Euler and Navier-Stokes equations to hypersonic computations. Numerical aspects of TVD schemes are identified which affect the convergence rate for hypersonic Mach numbers and real gas flows, but which have a negligible effect on low Mach number or perfect gas flows.

Yee, H. C.↗

Augmented reduced order models for turbulence

The authors introduce an augmented-basis method (ABM) to stabilize reduced-order models (ROMs) of turbulent incompressible flows. The method begins with standard basis functions derived from proper orthogonal decomposition (POD) of snapshot sets taken from a full-order model. These are then augmented with divergence-free projections of a subset of the nonlinear interaction terms that constitute a significant fraction of the time-derivative of the solution. The augmenting bases, which are rich in localized high wavenumber content, are better able to dissipate turbulent kinetic energy than the standard POD bases. Several examples illustrate that the ABM significantly out-performs L 2 -, H 1 - and Leray-stabilized POD ROM approaches. The ABM yields accuracy that is comparable to constraint-based stabilization approaches yet is suitable for parametric model-order reduction in which one uses the ROM to evaluate quantities of interests at parameter values that differ from those used to generate the full-order model snapshots. Several numerical experiments point to the importance of localized high wavenumber content in the generation of stable, accurate, and efficient ROMs for turbulent flows.

Kaneko, Kento↗

Aerodynamic performance of a 1.35-pressure-ratio axial-flow fan stage

The overall blade element performances and the aerodynamic design parameters are presented for a 1.35-pressure-ratio fan stage. The fan stage was designed for a weight flow of 32.7 kilograms per second and a tip speed of 302.8 meters per second. At design speed the stage peak efficiency of 0.879 occurred at a pressure ratio of 1.329 and design flow. Stage stall margin was approximately 14 percent. At design flow rotor efficiency was 0.94 and the pressure ratio was 1.360.

Osborn, W. M.↗

Novel Sorbent-Based Process for High Temperature Trace Metal Removal

The objective of this project was to demonstrate the efficacy of a novel sorbent can effectively remove trace metal contaminants (Hg, As, Se and Cd) from actual coal-derived synthesis gas streams at high temperature (above the dew point of the gas). The performance of TDA's sorbent has been evaluated in several field demonstrations using synthesis gas generated by laboratory and pilot-scale coal gasifiers in a state-of-the-art test skid that houses the absorbent and all auxiliary equipment for monitoring and data logging of critical operating parameters. The test skid was originally designed to treat 10,000 SCFH gas at 250 psig and 350 C, however, because of the limited gas handling capabilities of the test sites, the capacity was downsized to 500 SCFH gas flow. As part of the test program, we carried out four demonstrations at two different sites using the synthesis gas generated by the gasification of various lignites and a bituminous coal. Two of these tests were conducted at the Power Systems Demonstration Facility (PSDF) in Wilsonville, Alabama; a Falkirk (North Dakota) lignite and a high sodium lignite (the PSDF operator Southern Company did not disclose the source of this lignite) were used as the feedstock. We also carried out two other demonstrations in collaboration with the University of North Dakota Energy Environmental Research Center (UNDEERC) using synthesis gas slipstreams generated by the gasification of Sufco (Utah) bituminous coal and Oak Hills (Texas) lignite. In the PSDF tests, we showed successful operation of the test system at the conditions of interest and showed the efficacy of sorbent in removing the mercury from synthesis gas. In Test Campaign No.1, TDA sorbent reduced Hg concentration of the synthesis gas to less than 5 {micro}g/m{sup 3} and achieved over 99% Hg removal efficiency for the entire test duration. Unfortunately, due to the relatively low concentration of the trace metals in the lignite feed and as a result of the intermittent operation of the PSDF gasifier (due to the difficulties in the handling of the low quality lignite), only a small fraction of the sorbent capacity was utilized (we measured a mercury capacity of 3.27 mg/kg, which is only a fraction of the 680 mg/kg Hg capacity measured for the same sorbent used at our bench-scale evaluations at TDA). Post reaction examination of the sorbent by chemical analysis also indicated some removal As and Se (we did not detect any significant amounts of Cd in the synthesis gas or over the sorbent). The tests at UNDEERC was more successful and showed clearly that the TDA sorbent can effectively remove Hg and other trace metals (As and Se) at high temperature. The on-line gas measurements carried out by TDA and UNDEERC separately showed that TDA sorbent can achieve greater than 95% Hg removal efficiency at 260 C ({approx}200g sorbent treated more than 15,000 SCF synthesis gas). Chemical analysis conducted following the tests also showed modest amounts of As and Se accumulation in the sorbent bed (the test durations were still short to show higher capacities to these contaminants). We also evaluated the stability of the sorbent and the fate of mercury (the most volatile and unstable of the trace metal compounds). The Synthetic Ground Water Leaching Procedure Test carried out by an independent environmental laboratory showed that the mercury will remain on the sorbent once the sorbent is disposed. Based on a preliminary engineering and cost analysis, TDA estimated the cost of mercury removal from coal-derived synthesis gas as $2,995/lb (this analysis assumes that this cost also includes the cost of removal of all other trace metal contaminants). The projected cost will result in a small increase (less than 1%) in the cost of energy.

01 COAL, LIGNITE, AND PEAT↗

Forward Swept Compressor Testing

A new forward-swept rotor designed by Allison Engine Company was tested in NASA Lewis Research Center's CE-18 facility. This testing was a follow-on project sponsored by NASA Lewis to study range enhancements in small turbomachinery. The test was conducted against a baseline rotor design that was also tested in CE-18. The design point for the rotor was a rotor pressure ratio of 2.69, a mass flow of 10.52 lbm/sec, and an adiabatic efficiency of 89.1 percent. Test data indicate that the rotor met the pressure ratio of 2.69 with a 10.77 lbm/sec flow rate, a 87.5-percent adiabatic efficiency, and a 19.5-percent stall margin. The baseline rotor achieved a pressure ratio of 2.69 at a 10.77 lbm/sec flow rate with a stall margin of only 9.2 percent and an adiabatic efficiency of 87.0 percent. The major differences are the significant stall margin increase and the substantially higher off-design peak efficiencies of the forward-swept rotor. The substantially higher performance over the baseline rotor design makes the new design a viable technology candidate for future products.

Miller, David P.↗

Effect of casing treatment on performance of a two-stage high-pressure-ratio fan

A two-stage fan, previously tested with a solid casing, was tested with a casing with circumferential grooves over the tips of both rotors (casing treatment). Tests were conducted at 80 and 100 percent of design speed with uniform flow. The casing treatment improved the flow range and stall margin significantly without changing the characteristics overall performance curves of total-pressure and efficiency as functions of weight flow, other than extending them to lower weight flows.

Urasek, D. C.↗

Experimental quiet engine program aerodynamic performance of fan A

The aerodynamic component test results are presented of fan A, one of two high-bypass-ratio, 1160 feet per second single-stage fans, which was designed and tested as part of the NASA Experimental Quiet Engine Program. This fan was designed to deliver a bypass pressure ratio of 1.50 with an adiabatic efficiency of 86.5% at a total fan flow of 950 lb/sec. It was tested with and without inlet flow distortion. A bypass total-pressure ratio of 1.52 and an adiabatic efficiency of 88.3% at a total fan flow of 962 lb/sec were actually achieved. An operating margin of 12.4% was demonstrated at design speed.

Giffin, R. G.↗

Preliminary characterization of a water vaporizer for resistojet applications

A series of tests was conducted to explore the characteristics of a water vaporizer intended for application to resistojet propulsion systems. The objectives of these tests were to (1) observe the effect of orientation with respect to gravity on vaporizer stability, (2) characterize vaporizer efficiency and outlet conditions over a range of flow rates, and (3) measure the thrust performance of a vaporizer/resistojet thruster assembly. A laboratory model of a forced-flow, once-through water vaporizer employing a porous heat exchange medium was built and characterized over a range of flow rates and power levels of interest for application to water resistojets. In a test during which the vaporizer was rotated about a horizontal axis normal to its own axis, the outlet temperature and mass flow rate through the vaporizer remained steady. Throttlability to 30 percent of the maximum flow rate tested was demonstrated. The measured thermal efficiency of the vaporizer was near 0.9 for all tests. The water vaporizer was integrated with an engineering model multipropellant resistojet. Performance of the vaporizer/thruster assembly was measured over a narrow range of operating conditions. The maximum specific impulse measured was 234 s at a mass flow rate and specific power level (vaporizer and thruster combined) of 154 x 10(exp-6)kg/s and 6.8 MJ/kg, respectively.

Morren, W. Earl↗

The Radiative Efficiency and Spectra of Slowly Accreting Black Holes from Two-temperature GRRMHD Simulations

In this paper, we present axisymmetric numerical simulations of radiatively inefficient accretion flows onto black holes combining general relativity, magnetohydrodynamics, self-consistent electron thermodynamics, and frequency-dependent radiation transport. We investigate a range of accretion rates up to ${10}^{-5}\,{\dot{M}}_{\mathrm{Edd}}$ onto a ${10}^{8}\,{M}_{\odot }$ black hole with spin ${a}_{\star }=0.5$. We report on averaged flow thermodynamics as a function of accretion rate. We present the spectra of outgoing radiation and find that it varies strongly with accretion rate, from synchrotron-dominated in the radio at low $\dot{M}$ to inverse-Compton-dominated at our highest $\dot{M}$. In contrast to canonical analytic models, we find that by $\dot{M}\approx {10}^{-5}\,{\dot{M}}_{\mathrm{Edd}}$, the flow approaches $\sim 1 \% $ radiative efficiency, with much of the radiation due to inverse-Compton scattering off Coulomb-heated electrons far from the black hole. Finally, these results have broad implications for modeling of accreting black holes across a large fraction of the accretion rates realized in observed systems.

79 ASTRONOMY AND ASTROPHYSICS↗

An experimental investigation with artificial sunlight of a solar hot-water heater

Thermal performance measurements were made of a commercial solar hot water heater in a solar simulator to determine basic performance characteristics of a traditional type of flat plate collector, with and without side reflectors (to increase the solar flux). Information on each of the following was obtained; (1) the effect of flow and incidence angle on the efficiency of a flat plate collector (but only without side reflectors); (2) transient performance under flow and nonflow conditions; (3) the effectiveness of reflectors to increase collector efficiency for a zero radiation angle at fluid temperatures required for solar air conditioning; and (4) the limits of applicability of a collector efficiency correlation based on the Hottel Whillier equation.

Simon, F. F.↗

A numerical study of general viscous flows around multi-element airfoils

An efficient numerical procedure based on a velocity integral representation and Fourier series expansion is developed to compute the unsteady viscous flows around multielement airfoils. Flow developments initiated from an impulsively started motion of a Boeing VR7 airfoil with or without a leading-edge slat are studied in both laminar and turbulent flow conditions. The effect of the presence of the slat to the surface pressure distribution of the airfoil is assessed.

Wang, C. M.↗

Compliant and stretchable thermoelectric coils for energy harvesting in miniature flexible devices

With accelerating trends in miniaturization of semiconductor devices, techniques for energy harvesting become increasingly important, especially in wearable technologies and sensors for the internet of things. Although thermoelectric systems have many attractive attributes in this context, maintaining large temperature differences across the device terminals and achieving low–thermal impedance interfaces to the surrounding environment become increasingly difficult to achieve as the characteristic dimensions decrease. Here, we propose and demonstrate an architectural solution to this problem, where thin-film active materials integrate into compliant, open three-dimensional (3D) forms. This approach not only enables efficient thermal impedance matching but also multiplies the heat flow through the harvester, thereby increasing the efficiencies for power conversion. Interconnected arrays of 3D thermoelectric coils built using microscale ribbons of monocrystalline silicon as the active material demonstrate these concepts. Quantitative measurements and simulations establish the basic operating principles and the key design features. The results suggest a scalable strategy for deploying hard thermoelectric thin-film materials in harvesters that can integrate effectively with soft materials systems, including those of the human body.

42 ENGINEERING↗

Performance Demonstration of an Occupancy Sensor-enabled Integrated Solution for Commercial Buildings

Traditionally, a single-loop fixed-gain controller is applied to supply fan (SF) and cooling coil (CC) valve controls while a fixed-damper position control is applied to outdoor air (OA) damper control at air handling units (AHUs) in commercial buildings. With the increasing application of occupancy sensors, the information generated by occupancy sensors is applied to not only reduce the electricity loads from lighting and controllable plug loads, but also reset OA intake and minimum supply airflow setpoints. Meanwhile, these intermittent operation actions greatly elevate the dynamics of AHU systems, which may introduce unstable SF and CC valve operations and inaccurate OA flow control at AHUs and consequently degrade maximum energy efficiency gains. With virtual fan and valve flow meter technologies, two advanced controls, including cascade control and gain scheduling control, can be implemented on both the SF and CC valve, and an advanced control using a virtual OA flow meter can be implemented on OA damper integrated with occupancy sensors. The goal of this project is to demonstrate the savings, cost, and performance of an integrated solution that integrates the three advanced HVAC controls with occupancy sensors to allow accurate and stable AHU operations in real buildings. The project objectives are to: 1) develop and validate an advance SF control algorithm; 2) develop and validate an advanced CC valve control algorithm; 3) validate an algorithm to implement a virtual OA flow meter; and 4) demonstrate the savings, cost, and performance of the integrated solution in real buildings. The technical approaches are to: 1) select a test system at the University of Oklahoma; 2) develop and implement the algorithms of advanced SF and CC valve controls and validate the performance; 3) develop and implement the advanced OA control using a virtual OA flow meter and validate the performance; 4) demonstrate the savings, cost, and performance of the proposed integrated solution with and without three advanced HVAC controls; and 5) disseminate the project results through publications and presentations. For the SF control, both the gain scheduling and cascade controls can improve the fan energy performance by reducing the fan power during the transient period and the fan control performance at lower speeds by reducing fan speed variation. Moreover, the gain scheduling control provides a simple and low-cost solution and is recommended. The fan power savings can reach 30% in a transient period. For the CC valve control, the gain scheduling control can considerably reduce the supply air temperature oscillation range and frequency under both higher and lower load conditions and the control valve response is much more stable. As a result, the gain scheduling control is recommended. The projected pump energy consumption can be reduced by 68.5%. With the developed virtual OA flow meter, the OA can be accurately controlled at its setpoint, which is determined based on the actual number of occupants in the building provided by occupancy sensors. The RMSE of the proposed OA control is 15.9 L/s. The energy data shows that the fan power and CC cooling energy were significantly reduced. On the other hand, the energy savings majorly results from the occupancy sensors and the energy savings by the advanced HVAC controls is minimal because that the controllers in the test AHU were tuned with very slow response. An annual technical savings potential is estimated as 0.5 quads in the commercial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Single stage experimental evaluation of tandem-airfoil rotor and stator blading for compressors. Part 4: Data and performance for stage B

Stage B, composed of tandem-airfoil rotor B and stator B, was tested with uniform inlet flow and with hub radial, tip radial and 90 degree one-per-revolution circumferential distortion of the inlet flow as part of an overall program to evaluate the effectiveness of tandem airfoils for increasing the design point loading capability and stable operating range of rotor and stator blading. The results of this series of tests provide overall performance and blade element data for evaluating: (1) the potential of tandem blading for extending the loading limit and stable operating range of a stage representative of a middle stage of an advanced high pressure compressor, (2) the effect of loading split between the two airfoils in tandem on the performance of tandem blading, and (3) the effects of inlet flow distortion on the stage performance. The rotor had an inlet hub/tip ratio of 0.8 and a design tip velocity of 757 ft/sec. With uniform inlet flow, rotor B achieved a maximum adiabatic efficiency of 88.4% at design equivalent rotor speed and a pressure ratio of 1.31. The stage maximum adiabatic efficiency at design equivalent rotor speed with uniform inlet flow was 82.5% at a pressure ratio of 1.28. Tip radial and circumferential distortion of the inlet flow caused substantial reductions in surge margin.

Brent, J. A.↗

Single-stage experimental evaluation of tandem-airfoil rotor stator blading for compressors. Part 6: Data and performance for stage D

An axial flow compressor stage, having single-airfoil blading, was designed for zero rotor prewhirl, constant rotor work across the span, and axial discharge flow. The stage was designed to produce a pressure ratio of 1.265 at a rotor tip velocity of 757 ft/sec. The rotor had an inlet hub/tip ratio of 0.8. The design procedure accounted for the rotor inlet boundary layer and included the effects of axial velocity ratio and secondary flow on blade row performance. The objectives of this experimental program were: (1) to obtain performance with uniform and distorted inlet flow for comparison with the performance of a stage consisting of tandem-airfoil blading designed for the same vector diagrams; and (2) to evaluate the effectiveness of accounting for the inlet boundary layer, axial velocity ratio, and secondary flows in the stage design. With uniform inlet flow, the rotor achieved a maximum adiabatic efficiency of 90.1% at design equivalent rotor speed and a pressure ratio of 1.281. The stage maximum adiabatic efficiency at design equivalent rotor speed with uniform inlet flow was 86.1% at a pressure ratio of 1.266. Hub radial, tip radial, and circumferential distortion of the inlet flow caused reductions in surge pressure ratio of approximately 2, 10 and 5%, respectively, at design rotor speed.

Clemmons, D. R.↗