The Acoustic Influence of Cell Depth on the Rotordynamic Characteristics of Smooth-Rotor/Honeycomb-Stator Annular Gas Seals

A two-control volume is employed for honeycomb-stator/smooth-rotor seals, with a conventional control-volume used for the through flow and a 'capacitance accumulator' model for the honeycomb cells. The control volume for the honeycomb cells is shown to cause a dramatic reduction in the effective acoustic velocity of the main flow, dropping the lowest acoustic frequency into the frequency range of interest for rotordynamics. In these circumstances, the impedance functions for the seals can not be modeled with conventional (frequency-independent) stiffness, damping, and mass coefficients. More general transfer functions are required to account for the reaction forces, and calculated here as a lead-lag term for the direct force function and a lag term for the cross-coupled function. These first order functions are simple compared to transfer functions for magnetic bearings or foundations, For synchronous response to imbalance, they can be approximated by running-speed-dependent stiffness and damping coefficients in conventional rotordynamic codes. Correct predictions for stability and transient response will require more general algorithms, pressumably using a state-space format.

Childs, Dara W.↗

Bidirectional Pressure-Regulator System

A bidirectional pressure-regulator system has been devised for use in a regenerative fuel cell system. The bidirectional pressure-regulator acts as a back-pressure regulator as gas flows through the bidirectional pressure-regulator in one direction. Later, the flow of gas goes through the regulator in the opposite direction and the bidirectional pressure-regulator operates as a pressure- reducing pressure regulator. In the regenerative fuel cell system, there are two such bidirectional regulators, one for the hydrogen gas and another for the oxygen gas. The flow of gases goes from the regenerative fuel cell system to the gas storage tanks when energy is being stored, and reverses direction, flowing from the storage tanks to the regenerative fuel cell system when the stored energy is being withdrawn from the regenerative fuel cell system. Having a single bidirectional regulator replaces two unidirectional regulators, plumbing, and multiple valves needed to reverse the flow direction. The term "bidirectional" refers to both the bidirectional nature of the gas flows and capability of each pressure regulator to control the pressure on either its upstream or downstream side, regardless of the direction of flow.

Burke, Kenneth↗

Micro-Organ Devices

Micro-organ devices (MODs) are being developed to satisfy an emerging need for small, lightweight, reproducible, biological-experimentati on apparatuses that are amenable to automated operation and that imp ose minimal demands for resources (principally, power and fluids). I n simplest terms, a MOD is a microfluidic device containing a variety of microstructures and assemblies of cells, all designed to mimic a complex in vivo microenvironment by replicating one or more in vivo micro-organ structures, the architectures and composition of the extr acellular matrices in the organs of interest, and the in vivo fluid flows. In addition to microscopic flow channels, a MOD contains one or more micro-organ wells containing cells residing in microscopic e xtracellular matrices and/or scaffolds, the shapes and compositions o f which enable replication of the corresponding in vivo cell assembl ies and flows.

Gonda, Steven R.↗

A transmissive concentrator photovoltaic module with cells directly cooled by silicone oil for solar cogeneration systems

Hybrid concentrator photovoltaic-thermal systems can cogenerate electricity and heat by beam-splitting incoming concentrated light onto photovoltaic cells and a thermal receiver to increase total conversion efficiency and potentially reduce system cost. To demonstrate this, we have designed and prototyped a transmissive spectrum-splitting concentrator photovoltaic module that maximizes solar energy conversion by utilizing the entire solar spectrum. Visible light is collected using infrared-transmissive triple-junction photovoltaic cells to achieve an in-band module efficiency of 43.3% for light of wavelength λ < 873 nm, while 44.2% of out-of-band light with λ > 873 nm is transmitted through for collection by a thermal receiver. During testing on a dual-axis tracked parabolic concentrator dish at up to 166 suns, cell temperatures were maintained at 119 °C or below via a novel active cooling method. This cooling system strictly flows silicone oil directly across both sides of the cells, without inhibiting optical transmission, as verified through experimentation and simulation. The module was validated outdoors for 572 sun·hrs, and achieved a maximum thermal receiver temperature of 180 °C. 86.1% of incident solar power is collected at 166 suns average concentration collectively among the electrical, cooling, and thermal receiver subsystems. The remaining 13.9% is lost to mirror reflectivity, dish shadowing, receiver reflection, and thermal losses. The ability to directly cool the cells with an inert silicone oil offers the potential for reduced system cost relative to previous transmissive hybrid concentrator photovoltaic-thermal systems, including microfluidic-cooled designs. This solar cogeneration capability is valuable in a wide range of commercial and industrial applications.

14 SOLAR ENERGY↗

Prediction and Validation of Flow Properties in Porous Lattice Structures

High-porosity metal foams have been extensively studied as an attractive candidate for efficient and compact heat exchanger design. With the advancements in additive manufacturing, such foams can be manufactured with controlled topology to yield highly tailorable mechanical and transport properties. In this study, a lattice Boltzmann method (LBM)-based pore-scale model is implemented to simulate the fluid flow in additively manufactured (AM) metal foams with unit cell topologies of Cube, Face Diagonal (FD)-Cube, Tetrakaidecahedron (TKD), and Octet lattices. The pressure gradient versus average velocity profiles predicted by the LBM model were validated against in-house measurements on the AM lattice samples with the same unit cell topologies. Based on the simulation results, a novel hybrid model is proposed to accurately predict the volume averaged flow properties (permeability and inertial coefficients) of the four structures. Specifically, the linear LBM (neglecting inertial forces) is first implemented to obtain the intrinsic permeability, and then the standard LBM is applied to obtain the inertial coefficient. Convenient correlations for those flow properties as a function of porosity and fiber diameter are constructed. The effects of the AM print qualities on the flow properties are also discussed. The advantages of the hybrid model compared to the polynomial fitting approach for determining flow properties are discussed and compared quantitatively. The hybrid model and presented results are valuable for flow and thermal transport evaluation when designing new metal foams for specific applications and with different materials and topologies. Finally, the presented correlations based on pore-scale simulations can also be conveniently used in volume-averaged models to predict the macroscale flow behavior in such complex structures.

42 ENGINEERING↗

From Shuttle Main Engine to the Human Heart: A Presentation to the Federal Lab Consortium for Technology Transfer

A NASA engineer received a heart transplant performed by Drs. DeBakey and Noon after suffering a serious heart attack. 6 months later that engineer returned to work at NASA determined to use space technology to help people with heart disease. A relationship between NASA and Drs. DeBakey and Noon was formed and the group worked to develop a low cost, low power implantable ventricular assist device (VAD). NASA patented the method to reduce pumping damage to red blood cells and the design of a continuous flow heart pump (#5,678,306 and #5,947,892). The technology and methodology were licensed exclusively to MicroMed Technology, Inc.. In late 1998 MicroMed received international quality and electronic certifications and began clinical trials in Europe. Ventricular assist devices were developed to bridge the gap between heart failure and transplant. Early devices were cumbersome, damaged red blood cells, and increased the risk of developing dangerous blood clots. Application emerged from NASA turbopump technology and computational fluid dynamics analysis capabilities. To develop the high performance required of the Space Shuttle main engines, NASA pushed the state of the art in the technology of turbopump design. NASA supercomputers and computational fluid dynamics software developed for use in the modeling analysis of fuel and oxidizer flow through rocket engines was used in the miniaturization and optimization of a very small heart pump. Approximately 5 million people worldwide suffer from chronic heart failure at a cost of 40 billion dollars In the US, more than 5000 people are on the transplant list and less than 3000 transplants are performed each year due to the lack of donors. The success of ventricular assist devices has led to an application as a therapeutic destination as well as a bridge to transplant. This success has been attributed to smaller size, improved efficiency, and reduced complications such as the formation of blood clots and infection.

Fogarty, Jennifer A.↗

Nonselective enrichment for yeast adenine mutants by flow cytometry

The expression of certain adenine biosynthetic mutations in the yeast Saccharomyces cerevisiae results in a red colony color. This phenomenon has historically provided an ideal genetic marker for the study of mutation, recombination, and aneuploidy in lower eukaryotes by classical genetic analysis. In this paper, it is reported that cells carrying ade1 and/or ade2 mutations exhibit primary fluorescence. Based on this observation, the nonselective enrichment of yeast cultures for viable adenine mutants by using the fluorescence-activated cell sorter has been achieved. The advantages of this approach over conventional genetic analysis of mutation, recombination, and mitotic chromosomal stability include speed and accuracy in acquiring data for large numbers of clones. By using appropriate strains, the cell sorter has been used for the isolation of both forward mutations and chromosomal loss events in S. cerevisiae. The resolving power of this system and its noninvasiveness can easily be extended to more complex organisms, including mammalian cells, in which analogous metabolic mutants are available.

Non-NASA Center↗

Freeze Tape Casting of Functionally Graded Porous Ceramics

Freeze tape casting is a means of making preforms of ceramic sheets that, upon subsequent completion of fabrication processing, can have anisotropic and/or functionally graded properties that notably include aligned and graded porosity. Freeze tape casting was developed to enable optimization of the microstructures of porous ceramic components for use as solid oxide electrodes in fuel cells: Through alignment and grading of pores, one can tailor surface areas and diffusion channels for flows of gas and liquid species involved in fuel-cell reactions. Freeze tape casting offers similar benefits for fabrication of optimally porous ceramics for use as catalysts, gas sensors, and filters.

Sofie, Stephen W.↗

Advancing radioactive material research method: the development of a novel in situ particle-attached microfluidic electrochemical cell

This study aims to develop a microgram-scale microfluidic electrochemical cell (E-cell) for investigating the redox behavior of uranium oxide (UO 2 ). The traditional bulk electrochemical methods may require shielded facilities to investigate the hazardous materials, e.g., spent nuclear fuel, due to high radiation levels. Microfluidic E-cells offer advantages such as reduced radiation exposure, control over fluid flow rates, and high-throughput capabilities. Methods: The design of the E-cell considers electrode morphology, adhesion to a thin membrane, electrode configuration, and vacuum compatibility. Three techniques, including FIB-SEM lift-out, Au coating, and polyvinylidene fluoride (PVDF) binder, are explored for fabricating and attaching microgram quantities of UO 2 as working electrodes. The PVDF binder method proves to be the most effective, enabling the creation of a vacuum-compatible microfluidic E-cell. Results and discussion: The PVDF binder method demonstrates successful electrochemical responses and allows for real-time monitoring of UO 2 electrode behavior at the microscale. It offers chemical imaging capabilities using in situ SEM/EDS analysis. The technique provides consistent redox outcomes similar to bulk electrochemical analysis. Conclusion: The development of a microgram-scale microfluidic electrochemical cell using the PVDF binder technique enables the investigation of UO 2 redox behavior. It offers a low-risk approach with reduced radiation exposure and high-throughput capabilities. The technique provides real-time monitoring and chemical imaging capabilities, making it valuable for studying spent nuclear fuel systems and material characterization.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Computationally efficient models for aqueous organic redox flow batteries

The rising usage of intermittent energy has garnered the need for large scale energy storage systems. Redox flow batteries (RFB) based energy storage system shows promising potential. Numerical simulations and machine learning approaches have been widely used to study RFB performance. The development of autonomous material discovery framework and digital twin of energy storage system usually needs to query cell performance through fast response models. In this study, two computationally efficient models are introduced: a physics-based analytical flow battery model (EZBattery), and a machine learning operator model (Deep Operator Network, denoted by DeepONet). Both models can provide cell performance near instantly, and prediction accuracy was systematically examined on an application of evaluating the performances of a 780 cm 2 aqueous organic redox flow battery (AORFB), using potential anolyte candidates in dihydroxyphenazine (DHP)-based family of organic materials. A validated computationally expansive 3-dimensional multi-physics finite element model by COMSOL was used as the ground truth and provided the training data set for the DeepONet. 1280 samples were generated with 10 properties to mimic the different possible anolyte candidates, and the cell performances were evaluated under 10 different combined operating conditions. The accuracy comparisons for the two computationally efficient models show that both models can provide comparable accuracy in predicting cell charging/discharging voltage curves. DeepONet can provide slightly higher overall accuracy than EZBattery with faster calculation speed, but highly relies on the training dataset. EZBattery does not need a training dataset and can provide interpretable physics-based explanations of the results, while being more flexible to adjust to adapt any different cell designs, flow battery architectures, and electrolyte materials.

Analytical model↗

Stanford Thermal Earth Model for the Conterminous United States

Provided here are various forms of the Stanford Thermal Earth Model, as well as the data and methods used for its creation. The predictions produced by this model were visualized in two-dimensional spatial maps across the modeled depths (0-7 km) for the conterminous United States. The thermal earth model is made available as an application programming interface (API) and as feature layers on ArcGIS, which are both provided via links below. A data-driven spatial interpolation algorithm based on physics-informed graph neural networks was used to develop these national temperature-at-depth maps. The model satisfied the three-dimensional heat conduction law by predicting subsurface temperature, surface heat flow, and rock thermal conductivity. Many physical quantities, including bottomhole temperature, depth, geographic coordinates, elevation, sediment thickness, magnetic anomaly, gravity anomaly, gamma-ray flux of radioactive elements, seismicity, and electric conductivity were used as model inputs. Surface heat flow, temperature, and thermal conductivity predictions were constructed for depths of 0-7 km at an interval of 1 km with spatial resolution of 18 km2 per grid cell. The model showed superior temperature, surface heat flow and thermal conductivity mean absolute errors of 4.8C, 8.1 mW/m2 and 0.07 W/(C-m), respectively..

15 GEOTHERMAL ENERGY↗

Osteoblasts respond to pulsatile fluid flow with short-term increases in PGE(2) but no change in mineralization

Although there is no consensus as to the precise nature of the mechanostimulatory signals imparted to the bone cells during remodeling, it has been postulated that deformation-induced fluid flow plays a role in the mechanotransduction pathway. In vitro, osteoblasts respond to fluid shear stress with an increase in PGE(2) production; however, the long-term effects of fluid shear stress on cell proliferation and differentiation have not been examined. The goal of this study was to apply continuous pulsatile fluid shear stresses to osteoblasts and determine whether the initial production of PGE(2) is associated with long-term biochemical changes. The acute response of bone cells to a pulsatile fluid shear stress (0.6 +/- 0.5 Pa, 3.0 Hz) was characterized by a transient fourfold increase in PGE(2) production. After 7 days of static culture (0 dyn/cm(2)) or low (0.06 +/- 0.05 Pa, 0.3 Hz) or high (0.6 +/- 0.5 Pa, 3.0 Hz) levels of pulsatile fluid shear stress, the bone cells responded with an 83% average increase in cell number, but no statistical difference (P > 0.53) between the groups was observed. Alkaline phosphatase activity per cell decreased in the static cultures but not in the low- or high-flow groups. Mineralization was also unaffected by the different levels of applied shear stress. Our results indicate that short-term changes in PGE(2) levels caused by pulsatile fluid flow are not associated with long-term changes in proliferation or mineralization of bone cells.

NASA Discipline Musculoskeletal↗

Multigrid Acceleration of Time-Accurate Navier-Stokes Calculations

A numerical scheme to solve the unsteady Navier-Stokes equations is described. The scheme is fully implicit in time and is unconditionally stable (at least for first- and second-order discretizations of the physical time derivatives). With unconditional stability, the choice of the time step is based on the physical phenomena to be resolved rather than limited by numerical stability. This is especially important for high Reynolds number viscous flows, where the spatial variation of grid cell size can be as much as six orders of magnitude. A multigrid-multiblock, steady-state, three-dimensional Navier-Stokes solver, TLNS3D, was modified to iteratively invert the equations at each physical time step. The implementation of this procedure in TLNS3D is discussed. The implications of applying several popular turbulence models to unsteady flow are also considered. Numerical results are presented to show the application of the scheme to various two-dimensional turbulent flows. The results of a three-dimensional laminar flow calculation are also given.

Melson, N. Duane↗

Computed Flow Through An Artificial Heart Valve

Report discusses computations of blood flow through prosthetic tilting disk valve. Computational procedure developed in simulation used to design better artificial hearts and valves by reducing or eliminating following adverse flow characteristics: large pressure losses, which prevent hearts from working efficiently; separated and secondary flows, which causes clotting; and high turbulent shear stresses, which damages red blood cells. Report reiterates and expands upon part of NASA technical memorandum "Computed Flow Through an Artificial Heart and Valve" (ARC-12983). Also based partly on research described in "Numerical Simulation of Flow Through an Artificial Heart" (ARC-12478).

Rogers, Stewart E.↗

Soluble Protein Analysis using a Compact Bench-top Flow Cytometer

Future space exploration missions will require analytical technology capable of providing both autonomous medical care to the crew and investigative capabilities to researchers. While several promising candidate technologies exist for further development, flow cytometry is an attractive technology as it offers both crew health (blood cell count, leukocyte differential, etc.) and a wide array of biochemistry and immunology assays. research settings, the application of this technique to soluble protein analysis is also possible. Proteomic beads using fluorescent dyes for optical encoding were used to monitor six cytokines simultaneously in cell medium of cell cultures in stationary and rotating cell culture systems. The results of this work demonstrate that a compact flow cytometer, such as a system proposed for space flight, can detect a variety of soluble proteins for crew health and biotechnology experiments during long-term missions.

Pappas, Dimitri↗

Effect of convection on osteoblastic cell growth and function in biodegradable polymer foam scaffolds

Culture of seeded osteoblastic cells in three-dimensional osteoconductive scaffolds in vitro is a promising approach to produce an osteoinductive material for repair of bone defects. However, culture of cells in scaffolds sufficiently large to bridge critical-sized defects is a challenge for tissue engineers. Diffusion may not be sufficient to supply nutrients into large scaffolds and consequently cells may grow preferentially at the periphery under static culture conditions. Three alternative culturing schemes that convect media were considered: a spinner flask, a rotary vessel, and a perfusion flow system. Poly(DL-lactic-co-glycolic acid) (PLGA) foam discs (12.7 mm diameter, 6.0 mm thick, 78.8% porous) were seeded with osteoblastic marrow stromal cells and cultured in the presence of dexamethasone and L-ascorbic acid for 7 and 14 days. Cell numbers per foam were found to be similar with all culturing schemes indicating that cell growth could not be enhanced by convection, but histological analysis indicated that the rotary vessel and flow system produced a more uniform distribution of cells throughout the foams. Alkaline phosphatase (ALP) activity per cell was higher with culture in the flow system and spinner flask after 7 days, while no differences in osteocalcin (OC) activity per cell were observed among culturing methods after 14 days in culture. Based on the higher ALP activity and better cell uniformity throughout the cultured foams, the flow system appears to be the superior culturing method, although equally important is the fact that in none of the tests did any of the alternative culturing techniques underperform the static controls. Thus, this study demonstrates that culturing techniques that utilize fluid flow, and in particular the flow perfusion system, improve the properties of the seeded cells over those maintained in static culture.

NASA Discipline Cell Biology↗