Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flooring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Spatial distribution of internal heat gains: A probabilistic representation and evaluation of its influence on cooling equipment sizing in large office buildings

Internal heat gains from occupants, lighting, and plug loads are significant components of the space cooling load in an office building. Internal heat gains vary with time and space. The spatial diversity is significant, even for spaces with the same function in the same building. The stochastic nature of internal heat gains makes determining the peak cooling load to size air-conditioning systems a challenge. The traditional conservative practice of considering the largest internal heat gain among spaces and applying safety factors overestimates the space cooling load, which leads to oversized air-conditioning equipment and chiller plants. In this study, a field investigation of several large office buildings in China led to the development of a new probabilistic approach that represents the spatial diversity of the design internal heat gain of each tenant as a probability distribution function. In a large office building, a central chiller plant serves all air handling units (AHUs), with each AHU serving one or more floors of the building. Therefore, the spatial diversity should be considered differently when the peak cooling loads to size the AHUs and chillers are calculated. Finally, the proposed approach considers two different levels of internal heat gains to calculate the peak cooling loads and size the AHUs and chillers in order to avoid oversizing, improve the overall operating efficiency, and thus reduce energy use.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Predicting the performance of radiant technologies in attics: Reducing the discrepancies between attic specific and whole-building energy models

The use of radiant technology in attics aims to reduce the radiation component of heat transfer between the attic floor and roof decks, gables, and eaves. Recently, it has been shown that EnergyPlus underestimates the savings using radiant technologies in attic spaces. The aim of this study is to understand why EnergyPlus underestimates the performance of radiant technologies and provide a solution strategy that works within the current capabilities of EnergyPlus. The analysis uses three attic energy models as a baseline for comparison for EnergyPlus. Potential reasons for the discrepancies between the attic specific energy models and EnergyPlus are isolated and individually tested. A solution strategy is proposed using the Energy Management System (EMS) capabilities within EnergyPlus. This solution strategy produces similar results to the other attic specific energy models. This paper shows that the current capabilities of EnergyPlus are sufficient to simulate radiant technologies in attics. The methodology showcased in this paper serves as a guide for engineers and researchers who would like to predict the performance radiant technology in attics using the whole building energy software, EnergyPlus.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building commissioning costs and savings across three decades and 1500 North American buildings

B.V. Building commissioning (Cx) is a process for assuring efficient building operations that can be applied to new construction and existing buildings, resulting in energy and non-energy benefits. Quantifying the benefits of commissioning is challenging, but a 2009 study of 643 commercial buildings provided a solid initial data set to which we added 839 additional buildings for a significantly expanded and updated meta-analysis representing 34.7 million square meters (373 million square feet) of floor area. Since 2009 the commissioning industry has continued to grow, driven by building codes, utility programs, and rising awareness of commissioning benefits. In parallel, building controls have become more sophisticated, and analytics software has emerged to assist with commissioning. We find that delivery mechanism and market segment are key determinants of outcomes, although significant and cost-effective savings are found across the spectrum. Median primary energy savings for Cx projects in existing buildings ranged from 5 percent for those conducted under utility programs, 9 percent for monitoring-based commissioning utility programs (i.e., augmented with submetering and diagnostics), and 14 percent for Cx projects outside of utility programs. Across all project types, median savings ranged from 3 percent for the lodging market segment to 16 percent for public order and safety facilities. Outcomes did not vary significantly by building size or by market segment. Energy savings are rarely estimated for new construction commissioning. We found that the median costs of Cx were lower for the 2018 sample than for the 2009 sample—$\$$2.85 per square meter ($\$$0.26 per square foot) for existing buildings (a 33 percent reduction) and $\$$8.78 per square meter ($\$$0.82 per square foot) for new construction (a reduction of almost 50 percent). The median simple payback time for existing buildings was 1.7 years, with a 25th–75th percentile range of 0.8–3.5 years. Overall, this article summarizes these and other key findings, and discusses how the 2018 data reflects shifts in commissioning practice and outcomes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A method to generate heating and cooling schedules based on data from connected thermostats

Internet-connected thermostats are a promising new source of temperature and operational data in homes because they record inside temperatures, setpoints, and HVAC runtimes every five minutes. Over 20 million Internet-connected thermostats have already been installed in American homes. Data from about 20,000 connected thermostats were collected and organized by climate zone, number of occupants, floor area, and day type. A method was developed to create up to 40 representative temperature schedules which, together, can more accurately capture the diversity of heating and cooling behaviors. These results are suitable for input into schedules for building energy simulation models. This information enables more realistic simulations of American heating and cooling behavior, leading to more accurate estimates of energy consumption and savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coupling thermal energy storage with a thermally anisotropic building envelope for building demand-side management across various US climate conditions

Here, the thermally anisotropic building envelope (TABE) is a novel active building envelope that enhances energy efficiency and thermal comfort in buildings by transferring heat and cold between building envelopes and hydronic loops. When coupled with thermal energy storage (TES) units, the TABE + TES enables the storage of both heat and cold energy captured by the TABE roof or exterior walls. This stored energy can be later released by the TABE floor for indoor heating and cooling, benefiting both the grid and the end user. This paper evaluates the merits of TABE + TES for building demand-side management across various US climate conditions, focusing on peak load shaving, annual energy savings, and cost savings under time-of-use (TOU) electric rate schedules. Simulations were conducted by integrating time-of-day–informed, rule-based control strategies in MATLAB, TABE components and TES units in COMSOL Multiphysics, and whole-building energy analysis in EnergyPlus. A case study using the US Department of Energy’s prototype single-family detached house model in Birmingham, Alabama; Los Angeles, California; Oak Ridge, Tennessee; and Denver, Colorado, showed that the TABE + TES system achieved (1) 70 % peak load shaving in Los Angeles and Denver and 20 % in Birmingham and Oak Ridge; (2) significant peak electricity savings of 351–497 kWh, reducing peak energy consumption by 38 %–78 %; and (3) annual heating cost savings of 0.79 $\$$/m2–1.17 $\$$/m 2 and cooling cost savings of 0.60 $\$$/m 2 –1.17 $\$$/m 2 using a normal utility rate or low-TOU rate. The benefits of employing the TABE + TES system are even more significant under high TOU rates.

25 ENERGY STORAGE↗

Field evaluation of zone temperature response to control actions in cooling systems of small and medium-sized office buildings

The response of zone temperature to control actions in heating, ventilation, and air conditioning (HVAC) systems, known as zone temperature response, has been a central focus of building control research owing to its crucial role in determining control performance. However, existing studies often overlook the representativeness of the buildings being studied, resulting in unclear generalizations. In addition, those studies tend to focus on a single aspect of the response. Furthermore, this paper provides the first comprehensive characterization of zone temperature response applicable to a clearly defined building sector—small and medium-sized office (SMO) buildings (<5000 m 2 ) in the US. Specifically, two representative SMO buildings, selected based on the US Department of Energy’s commercial prototype buildings, were studied. Field tests were conducted over a 2-month period during summer, and the collected data were analyzed with two key metrics—delay time and nonlinearity index—to quantify zone temperature response, capturing both short- and long-term patterns. Beyond this quantitative characterization, the analysis reveals that the HVAC system type, rather than factors like floor area or zone location, is the primary determinant of the zone temperature response. Drawing on the field test results, we recommend that building control strategies monitor zone temperatures at intervals shorter than 10 minutes, configure controls independently for VAV- and RTU-served zones, and implement nonlinear methods at the zone level—particularly for VAV zones—rather than across the entire building.

Building control↗

Conditional distribution estimation of building characteristics with diffusion models for urban energy modeling

Understanding current energy consumption behavior in communities is critical for informing future energy use decisions and enabling efficient energy management. Urban energy models, which are used to simulate these energy use patterns, require large datasets with detailed building characteristics for accurate outcomes. However, such detailed characteristics at the individual building level are often unknown and costly to acquire, or unavailable. Through this work, we propose using a generative modeling approach to generate realistic building attributes to fill in the data gaps and finally provide complete characteristics as inputs to energy models. Our model learns complex, building-level patterns from training on a large-scale residential building stock model containing 2.2 million buildings. We employ a tabular diffusion-based framework that is designed to handle heterogeneous (discrete and continuous) features in tabular building data, such as occupancy, floor area, heating, cooling, and other equipment details. We develop a capability for conditional diffusion, enabling the imputation of missing building characteristics conditioned on known attributes. We conduct a comprehensive validation of our conditional diffusion model, firstly by comparing the generated conditional distributions against the underlying data distribution, and secondly, by performing a case study for a Baltimore residential region, showing the practical utility of our approach. Our work is one of the first to demonstrate the potential of generative modeling to accelerate building energy modeling workflows.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Determinants of residential electricity consumption: Using smart meter data to examine the effect of climate, building characteristics, appliance stock, and occupants' behavior

We propose a method to examine structural and behavioral determinants of residential electricity consumption, by developing separate models for daily maximum (peak) and minimum (idle) consumption. We apply our method on a data set of 1628 households' electricity consumption. The results show that weather, location and floor area are among the most important determinants of residential electricity consumption. In addition to these variables, number of refrigerators and entertainment devices (e.g., VCRs) are among the most important determinants of daily minimum consumption, while number of occupants and high-consumption appliances such as electric water heaters are the most significant determinants of daily maximum consumption. Installing double-pane windows and energy-efficient lights helped to reduce consumption, as did the energy-conscious use of electric heater. Acknowledging climate change as a motivation to save energy showed correlation with lower electricity consumption. Households with individuals over 55 or between 19 and 35 years old recorded lower electricity consumption, while pet owners showed higher consumption. Contrary to some previous studies, we observed no significant correlation between electricity consumption and income level, home ownership, or building age. Some otherwise energy-efficient features such as energy-efficient appliances, programmable thermostats, and insulation were correlated with slight increase in electricity consumption. (C) 2013 Elsevier Ltd. All rights reserved.

Kavousian, A↗

How will United States commercial building energy use be impacted by IPCC climate scenarios?

Climate change and anthropogenically-forced shift of weather in the future will impact energy use and resilience of both the built environment and the electric grid. The aim of this analysis is to understand how future climate scenarios will impact electricity and natural gas use of commercial buildings in the United States. Here, this study analyzes this impact for 2030, 2045, and 2100 using Representative Concentration Pathways (RCP) scenarios defined in Intergovernmental Panel on Climate Change (IPCC) Assessment Report 5. The large, gridded simulation of meteorological variables for RCPs 2.6, 4.5, 6.0, and 8.5 are selected and downscaled to make available hourly Future Meteorological Year (FMY) weather files for use and improvement in subsequent studies. High performance computing resources use these FMYs to simulate commercial prototype buildings in every American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE) climate zone of the United States (US), and results are scaled to nation-wide energy use using conditioned floor area multipliers. The analysis is conducted without speculating the physical and performance traits of future buildings or the grid characteristics. This analysis quantifies the impact of climate change on source electrical and natural gas usage for commercial buildings in the United States over the next 80 years. If US commercial floorspace remained constant, total energy use by 2100 is predicted between an 1.75% decrease under the greatest emission scenario (8.5) and a 1.76% increase under the lowest emission scenario (2.6). When adjusted for anticipated urban growth by 2100, the predicted range is 65% increase (8.5) and 71% increase (2.6). Under a global temperature rise climate scenario, the warmest US climate zones will see a large increases in electricity use derived from space cooling while the coldest US climate zones will see significant decreases in natural gas use caused by the decrease in heating necessary. While climate change may ultimately require adaptations of the built environment to withstand its effects and because the United States is a country that requires more heating than cooling, from a building energy perspective, climate change (average temperature rise) is a net energy saver for the United States.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermally induced cracking on the massive concrete structure of the NSLS II synchrotron and its engineering remediation

Synchrotron accelerator facilities such as the NSLS II require extreme stability, both transient (short-term) and quasi-static (long-term) to achieve the desired resolution performance. Consequently, even μm-level movements, particularly differential movements between locations in the concrete structure supporting the accelerator electron beam lattice (storage ring) or high sensitivity experiments (experimental floor) will lead to serious degradation of its performance. Differential settlement in the overall structure or structural movement exceeding anticipated levels will inevitably degrade the performance and will require intervention. Presented in this paper are the design philosophy of the NSLS II ring structure favoring a monolithic ring, the observed cracking behavior of the young NSLS II concrete following casting and in combination with extreme ambient temperature fluctuation, the results of a non-linear, high-fidelity numerical analysis used to emulate the observed cracking and establish the driving mechanism, the numerical analysis-based identification of the crack-arresting solution and finally the implementation of the remediation solution and the long-term performance of the adopted engineering solution. The multi-stage process revealed that computational methods such as non-linear finite element methods have the potential of providing engineering guidance even when complex structures and in combination with non-linear materials, such as steel reinforcement and concrete are involved.

42 ENGINEERING↗

Evaluating project level investment trends for the U.S. ESCO industry: 1990–2017

Energy efficiency is widely recognized as a cost-effective strategy to meet energy demand. The U.S. energy service company (ESCO) industry generates significant energy savings and other benefits through installing and maintaining energy efficiency, renewable and other types of projects. In this study, we evaluate factors that may explain trends in the economic performance of U.S. ESCO projects by analyzing project level data for ~7000 U.S. ESCO industry projects. We find that real project investment levels normalized for floor area have increased over time in ESCO projects across market segments. However, the dollar value of energy savings and other reported benefits have not kept pace with increases in real project investment levels over time. The latter have increased 100%–500% in various market segments from 1990 to 2017. We conduct an econometric analysis to decompose the drivers of these underlying trends. Number of measures and a changing mix of conservation measures are the primary factors that correlate with the long-term increase in project investment levels. However, our analysis is only able to account for less than 50% of the increase in real investment levels. Finally, we discuss additional factors, and conclude discussing policy implications and outlining long-term research needs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Assessing electrification readiness in U.S. single-family homes based on a nationwide survey of electrical panel capacities

Electrification of residential buildings is a key strategy for increasing the use of renewable energy sources. Central to this transition is understanding the capacity of existing electrical infrastructure—specifically electrical panels—to safely and effectively manage increased electricity demands from electrification technologies. However, comprehensive nationwide data on electrical panel capacities in U.S. single-family homes is currently lacking. To address this gap, we conducted a nationwide survey of single-family homes, collecting detailed data on electrical panel capacities, breaker slot availability, major electric and gas appliances, electrical panel models, and home characteristics such as construction year and floor area. Photographic documentation was used to verify electrical panel data and appliance information. Results show that approximately 60% of surveyed homes have electrical panels rated at ≥200 amperes (A), indicating that a significant portion of the existing housing stock can accommodate additional electric loads. However, 31% of homes possess panels rated at ≤100 A, potentially restricting their ability to adopt new electric appliances without significant upgrades. Panel capacities positively correlate with both home size and construction year, with newer and larger homes generally better suited for electrification. Homes with higher-capacity panels tend to have fewer gas appliances, reflecting a gradual shift toward electric technologies. Conversely, homes with lower-capacity panels frequently rely on multiple gas appliances, highlighting substantial electrification challenges. Additionally, approximately 3% of surveyed homes had potentially hazardous electrical panel models, emphasizing important safety considerations in the residential electrification process. Our findings underscore the need for targeted policies, financial incentives, and infrastructure investments designed specifically to address infrastructural and safety barriers, particularly in older and smaller homes, to support equitable and efficient electrification across the U.S. residential sector.

Gul, Sadia↗

An observational study of the potential for human exposures to pet-borne diazinon residues following lawn applications

This study examined the potential for pet dogs to be an important pathway for transporting diazinon residues into homes and onto its occupants following residential lawn applications. The primary objectives were to investigate the potential exposures of occupants and their pet dogs to diazinon after an application to turf at their residences and to determine if personal contacts between occupants and their pet dogs resulted in measurable exposures. It was conducted from April to August 2001 before the Agency phased out all residential uses of diazinon in December 2004. Six families and their pet dogs were recruited into the study. Monitoring was conducted at pre-, 1, 2, 4, and 8 days post-application of a commercial, granular formulation of diazinon to the lawn by the homeowner. Environmental samples collected included soil, indoor air, carpet dust, and transferable residues from lawns and floors. Samples collected from the pet dogs consisted of paw wipes, fur clippings, and transferable residues from the fur by a technician or child wearing a cotton glove(s). First morning void (FMV) urine samples were collected from each child and his/her parent on each sampling day. Diazinon was analyzed in all samples, except urine, by GC-MS. The metabolite 2-isopropyl-4-methyl-6-hydroxypyrimidine (IMPy) was analyzed in the urine samples by HPLC-MS/MS. Mean airborne residues of diazinon on day 1 post-application were at least six times higher in both the living rooms (235{+-}267 ng/m{sup 3}) and children's bedrooms (179{+-}246 ng/m{sup 3}) than at pre-application. Mean loadings of diazinon in carpet dust samples were at least 20 times greater on days 2, 4, and 8 post-application than mean loadings (0.03{+-}0.04 ng/cm{sup 2}) at pre-application. The pet dogs had over 900 times higher mean loadings of diazinon residues on their paws on day 1 post-application (88.1{+-}100.1 ng/cm{sup 2}) compared to mean loadings (<0.09 ng/cm{sup 2}) at pre-application. The mean diazinon loadings on the fur clippings were at least 14 times higher on days 1, 2, 4, and 8 post-application than mean loadings (0.8{+-}0.4 ng/cm{sup 2}) at pre-application. For transferable residues from dog fur, the mean loadings of diazinon on the technician's cotton glove samples were the lowest before application (0.04{+-}0.08 ng/cm{sup 2}) and the highest on day 1 post-application (10.4{+-}23.9 ng/cm{sup 2}) of diazinon to turf. Urinary IMPy concentrations for the participants ranged from <0.3 to 5.5 ng/mL before application and <0.3-12.5 ng/mL after application of diazinon. The mean urinary IMPy concentrations for children or adults were not statistically different (p>0.05) at pre-application compared to post-application of diazinon to turf. The results showed that the participants and their pet dogs were likely exposed to low levels of diazinon residues from several sources (i.e., air, dust, and soil), through several pathways and routes, after lawn applications at these residences. Lastly, the pet dog appears to be an important pathway for the transfer and translocation of diazinon residues inside the homes and likely exposed occupants through personal contacts (i.e., petting)

60 APPLIED LIFE SCIENCES↗

Surface dust wipes are the best predictors of blood leads in young children with elevated blood lead levels

Background: As part of the only national survey of lead in Australian children, which was undertaken in 1996, lead isotopic and lead concentration measurements were obtained from children from 24 dwellings whose blood lead levels were ≥15 µg/dL in an attempt to determine the source(s) of their elevated blood lead. Comparisons were made with data for six children with lower blood lead levels (<10 µg/dL). Methods: Thermal ionisation and isotope dilution mass spectrometry were used to determine high precision lead isotopic ratios ({sup 208}Pb/{sup 206}Pb, {sup 207}Pb/{sup 206}Pb and {sup 206}Pb/{sup 204}Pb) and lead concentrations in blood, dust from floor wipes, soil, drinking water and paint (where available). Evaluation of associations between blood and the environmental samples was based on the analysis of individual cases, and Pearson correlations and multiple regression analyses based on the whole dataset. Results and discussion: The correlations showed an association for isotopic ratios in blood and wipes (r=0.52, 95% CI 0.19–0.74), blood and soil (r=0.33, 95% CI −0.05–0.62), and blood and paint (r=0.56, 95% CI 0.09–0.83). The regression analyses indicated that the only statistically significant relationship for blood isotopic ratios was with dust wipes (B=0.65, 95% CI 0.35–0.95); there were no significant associations for lead concentrations in blood and environmental samples. There is a strong isotopic correlation of soils and house dust (r=0.53, 95% CI 0.20–0.75) indicative of a common source(s) for lead in soil and house dust. In contrast, as with the regression analyses, no such association is present for bulk lead concentrations (r=−0.003, 95% CI −0.37–0.36), the most common approach employed in source investigations. In evaluation of the isotopic results on a case by case basis, the strongest associations were for dust wipes and blood. -- Highlights: • Children with elevated blood lead ≥15 µg/dL compared with a group with <10 µg/dL. • High precision lead isotopic ratios in blood, house dust wipes, soil, water, paint. • Associations for isotopic measures of blood and dust, blood and soil, blood and paint. • Regressions gave significance for isotopic measures of blood/dust and dust/soil.

54 ENVIRONMENTAL SCIENCES↗

Characterization and flux assessment of airborne phthalates released from polyvinyl chloride consumer goods

Highlights: • Enhanced levels of semi-volatile organic compounds (SVOCs) can affect human health. • The major SVOCs like phthalates are released into indoor by many sources like plasticizers. • This study investigated the emission characteristics of diverse phthalates from plastic/rubber products. • Emission behavior of phthalates is described in relation to several key variables, e.g., types of PVC. The concentrations and fluxes of airborne phthalates were measured from five types of polyvinyl chloride (PVC) consumer products (vinyl flooring, wallcovering, child's toy, yoga mat, and edge protector) using a small chamber (impinger) system. Airborne phthalates released from each of those PVC samples were collected using sorbent (Tenax TA) tubes at three temperature control intervals (0, 3, and 6 h) under varying temperature conditions (25, 40, and 90 °C). A total of 11 phthalate compounds were quantified in the five PVC products examined in this study. To facilitate the comparison of phthalate emissions among PVC samples, their flux values were defined for total phthalates by summing the average fluxes of all 11 phthalates generated during the control period of 6 h. The highest flux values were seen in the edge protector sample at all temperatures (0.40 (25 °C), 9.65 (40 °C), and 75.7 μg m{sup −2} h{sup −1} (90 °C)) of which emission was dominated by dibutyl isophthalate. In contrast, the lowest fluxes were found in wallcovering (0.01 (25 °C) and 0.05 μg m{sup −2} h{sup −1} (40 °C)) and child's toy (0.23 μg m{sup −2} h{sup −1} (90 °C)) at each temperature level. The information regarding phthalate composition and emission patterns varied dynamically with type of PVC sample, controlled temperature, and duration of control.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of NOx emissions of a retrofitted Euro 5 passenger car for the Horizon prize “Engine retrofit”

Highlights: • Many studies report diesel vehicles emitting more than 4 times the type approval NO{sub x} in real driving conditions. • One solution is retrofitting them, but there is no legislative background for passenger cars. • The Horizon 2020 prize for the “Engine Retrofit for Clean Air” aims at reducing the pollution in cities. • A Euro 5 retrofitted vehicle showed significant reductions over test cycles, but small at the cold start phases. • In some high speed conditions NH{sub 3} and N{sub 2}O were measured. The Horizon 2020 prize for the “Engine Retrofit for Clean Air” aims at reducing the pollution in cities by spurring the development of retrofit technology for diesel engines. A Euro 5 passenger car was retrofitted with an under-floor SCR (Selective Catalytic Reduction) for NO{sub x} catalyst in combination with a solid ammonia based dosing system as the NO{sub x} reductant. The vehicle was tested both on the road and on the chassis dynamometer under various test cycles and ambient temperatures. The NO{sub x} emissions were reduced by 350–1100 mg/km (60–85%) in the laboratory depending on the test cycle and engine conditions (cold or hot start), except at type approval conditions. The reduction for cold start urban cycles was < 75 mg/km (< 15%). The on road and laboratory tests were inline. In some high speed conditions significant increase of ammonia (NH{sub 3}) and nitrous oxide (N{sub 2}O) were measured. No effect was seen on other pollutants (hydrocarbons, carbon monoxide and particles). The results of the present study show that retrofitting high emitting vehicles can significantly reduce vehicle NO{sub x} emissions and ultimately pollution in cities.

54 ENVIRONMENTAL SCIENCES↗

Organic sulfur fluxes and geomorphic control of sulfur isotope ratios in rivers

Pyrite oxidation plays a critical role in the relationship between weathering and climate, and its impact on the global carbon cycle has previously been constrained through inversion models utilizing observations of river sulfate ($SO^{2–}_{4}$) and its 34 S/ 32 S isotope ratio (δ 34 S SO4 ). However, measurements from some rivers have suggested that SSO4 can be substantially impacted by processes such as microbial sulfate reduction and/or sulfur assimilation and cycling, rather than simply reflecting a weighted mixture of lithologic sulfur sources. To study the prevalence and controls on $SO^{2–}_{4}$ transformations, in this study we measured dissolved major element concentrations and δ 34 S SO4 in river water samples from throughout western Iceland. Our analyses focused on samples from a small catchment hosting the Efri Haukadalsá river, a system with relatively uniform and isotopically constrained basaltic bedrock. We also measured sediment δ 34 S and sulfur speciation using sulfur K-edge X-ray absorption spectroscopy on sediment and vegetation samples from this catchment. Values of dissolved δ 34 S SO4 in the Efri Haukadalsá ranged from 2.5‰ to 23.7‰ and had a linear relationship with Cl – /$SO^{2–}_{4}$ ratios, indicating that $SO^{2–}_{4}$ predominantly derived from basalt weathering and meteoric precipitation. The lower δ 34 S SO4 values were found in fluvial valleys with V-shaped cross sections, while higher values of δ 34 S SO4 occurred in U-shaped, glacially eroded valleys with thick alluvial fills blanketing the valley floor. Spectroscopic observations identified organic sulfur phases in suspended river sediment, floodplain deposits, and vegetation. Mass balance calculations quantified the organic sulfur flux as less than 10% of $SO^{2–}_{4}$ export, and sediment δ 34 S values were comparable to river δ 34 S SO4 . We interpreted these isotopic and chemical patterns as reflecting differences in the availability of unweathered bedrock across the Efri Haukadalsá catchment, with V-shaped valleys having greater access to fresh sulfide-bearing minerals than alluviated U-shaped valleys; this interpretation is in contrast to one in which the elevated δ 34 S SO4 values reflect fractionation during sulfur transformations along alluvial reaches. These results validated the application of river inversion models for constraining weathering fluxes and affirmed that pyrite oxidation globally, even in the presence of river sulfur cycling, modulates the abundance of atmospheric carbon dioxide.

54 ENVIRONMENTAL SCIENCES↗

Earthquake-triggered submarine canyon flushing transfers young terrestrial and marine organic carbon into the deep sea

Submarine canyons transfer substantial amounts of sediment and organic carbon (OC) into the deep ocean, nourishing deep-sea ecosystems and contributing to the global carbon cycle through OC burial and sequestration. Tracking lateral OC transport through submarine canyon systems is challenged by the deep-ocean setting, difficulties with constraining episodic depositional events, and the need to assess the composition and age of marine and terrestrial organic matter. We apply innovative parallel ramped pyrolysis oxidation accelerator mass spectrometry and pyrolysis-gas chromatography-mass spectrometry with isotope analyses to track OC age and sources in the 2016 Kaikoura earthquake-triggered, canyon-flushing event that deposited along >1300 km of a submarine canyon-channel system, offshore Aotearoa New Zealand. Specifically, these techniques allow us to determine the ages, sources, and partitioning of OC within the Kaikoura turbidite deposit and test hypotheses of how submarine canyon systems contribute to lateral OC flux and burial. Our results show that, despite considerable canyon floor erosion, substantial amounts of young OC were flushed into the deep sea, with relatively little (~2%) pre-Holocene OC contributions. Even without a direct connection between rivers and submarine canyons, most (~55%) of the OC in the Kaikoura event bed is from terrestrial sources. However, the deposit also contains substantial amounts (~22%) of marine-derived OC and ~23% of the material is of unassignable origin. Particle sorting imparts variability on the age and composition of OC within turbidite deposits and along the turbidity current flow path. Terrestrial-derived OC is preferentially older than marine-derived OC and concentrated in coarser particle sizes found more commonly at the deposit base and in proximal settings. Young, marine-derived OC is concentrated at the surface of the deposits and tends to be enriched in finer particle sizes. Such OC partitioning in turbidites supports the relevance of depositional models for predicting and quantifying distribution of OC in deep-sea deposits. Earthquake-triggered, canyon flushing events and resulting turbidites enhance OC burial efficiency and can sequester OC effectively, contributing an important carbon sink to the sedimentary carbon cycle.

54 ENVIRONMENTAL SCIENCES↗