Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flexure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Signal propagation in reversible digital mechanics

Digital mechanics explores information processing through binary, mechanical circuits. This work demonstrates a flexural, mechanical integrated circuit (m-IC) that achieves reversible, non-reciprocal signal propagation through integrated AND logic and memory. Our approach exploits sequential bistable transitions with symmetric energy wells, tunable stiffness, impedance matching, and AND gate non-linearity, to enable signal propagation, repeatability, and reversibility. We present a generalized model of logic kinematics and energetics, validated experimentally, to study energy flows, quantify energetic limits, and identify operating regimes for reversible logic. Macro-scale experiments confirm propagation dynamics, and new fabrication methods extend the architecture to micro-scale devices. By achieving controlled, reversible signal transmission across interconnected logic and memory, this work establishes a scalable platform for robust mechanical computing and adaptive sensing.

Johnson, Hilary A. [Lawrence Livermore National La↗

High frequency columnar silicon microresonators for mass detection

A simple but effective technological scheme for the fabrication of high frequency silicon columnar microresonators is presented. With the proposed technique the dimensions of the microresonators are controlled on a scale of at least 1 {mu}m. Characterization of the mechanical properties of silicon columns gave resonant frequencies of the lowest flexural mode of 3-7 MHz with quality factors of up to 2500 in air and {approx}8800 under vacuum condition. Columnar microresonators were operated as mass balance with a sensitivity of 1 Hz/fg. A mass detection limit of 25 fg was deduced from experiments.

36 MATERIALS SCIENCE↗

A Comparison Among Plastic Deformation Capacities of RC Members According to International Codes

The aim is to compare plastic deformation capacities of flexure-controlled reinforced concrete members, as predicted by the Italian Seismic Code, Eurocode 8 and FEMA356. For completeness, recent studies in the literature are also referred to. The comparison is pursued in context with a nonlinear static analysis run on 2D frame structures. This allows to assess whether and to which extent plastic deformation capacities may be affected by variations in those quantities, such as shear span and/or axial load, depending on which plastic deformation capacities are generally given.0.

58 GEOSCIENCES↗

Evaluating the Dynamic Characteristics of Retrofitted RC Beams

The aim of this experimental study was to investigate the relationship between the damage and changes in dynamic characteristics of reinforced concrete members strengthened with Carbon Fiber Reinforced Polymer (CFRP). Modal analysis is a popular non-destructive method for evaluating health of structural systems. A total of 8 reinforced concrete beams with similar dimensions were made using concrete with two different compressive strengths and reinforcement ratios. Monotonic loading was applied with four-point-bending setup in order to generate different damage levels in the specimens while dynamic testing was conducted to monitor the changes in dynamic characteristics of the specimens. In order to investigate the effect of CFRP on static and dynamic properties of specimens, some of the beams were loaded to half of their ultimate load carrying capacity and then were retrofitted using composite laminates with different configuration. Retrofitted specimens demonstrated elevated load carrying capacity, higher flexural stiffness and lower displacement ductility. By increasing the damage level in specimens, frequencies of the beams were decreased and after strengthening these values were improved significantly. The intensity of the damage level in each specimen affects the shape of its mode as well. Fixed points and curvatures of mode shapes of beams tend to move toward the location of the damage in each case.

36 MATERIALS SCIENCE↗

Influence of shear in the non-linear analysis of RC members

The purpose of this study is to develop an analytical model characterized by a beam-column finite element which is able to reproduce the non-linear flexural-shear behavior of RC structures. The paper shows a brief description of the finite element formulation, the theory used for modeling the constitutive relationship and the scheme of the algorithm, transformed in a computer program, which was developed for implementing the theoretical model. Finally it illustrates a comparison with available experimental results for the calibration and validation of the model and a study on the influence of the non-linear shear response.

58 GEOSCIENCES↗

CARBON FIBRE COMPOSITE MATERIALS PRODUCED BY GAMMA RADIATION INDUCED CURING OF EPOXY RESINS

It is well known that ionizing radiation can initiate polymerization of suitable monomers for many applications. In this work an epoxy difunctional monomer has been used as matrix of a carbon fibre composite in order to produce materials through gamma radiation, for aerospace and advanced automotive applications. Radiation curing has been performed at different absorbed doses and, as comparison, also thermal curing of the same monomer formulations has been done. Furthermore some irradiated samples have been also subjected to a post irradiation thermal curing in order to complete the polymerization reactions. The properties of the cured materials have been studied by moisture absorption isotherms, dynamic mechanical thermal analysis and mechanical flexural tests.

36 MATERIALS SCIENCE↗

Cancellation of environmental effects in resonant mass sensors based on resonance mode and effective mass

A novel technique is developed to cancel the effect of environmental parameters, e.g., temperature and humidity, in resonant mass sensing. Utilizing a single resonator, the environmental cancellation is achieved by monitoring a pair of resonant overtones and the effective sensed mass in those overtones. As an eminent advantage, especially compared to dual-mode temperature compensation techniques, the presented technique eliminates any need for previously measured look-up tables or fitting the measurement data. We show that a resonant cantilever beam is an appropriate platform for applying this technique, and derive an analytical expression to relate the actual and effective sensed masses on a cantilever beam. Thereby, it is shown that in applying the presented technique successfully, the effective sensed masses must not be the same in the investigated pair of resonance overtones. To prove the feasibility of the proposed technique, flexural resonance frequencies of a silicon cantilever are measured before and after loading with a strip of photoresist. Applying the presented technique shows significant reductions in influence of environmental parameters, with the temperature and humidity coefficients of frequency being improved from -19.5 to 0.2 ppm deg. C{sup -1} and from 0.7 to -0.03 ppm %RH{sup -1}, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A laser interferometer for measuring straightness and its position based on heterodyne interferometry

Not only the magnitude but also the position of straightness errors are of concern to users. However, current laser interferometers used for measuring straightness seldom give the relative position of the straightness error. To solve this problem, a laser interferometer for measuring straightness and its position based on heterodyne interferometry is proposed. The optical configuration of the interferometer is designed and the measurement principle is analyzed theoretically. Two experiments were carried out. The first experiment verifies the validity and repeatability of the interferometer by measuring a linear stage. Also, the second one for measuring a flexure-hinge stage demonstrates that the interferometer is capable of nanometer measurement accuracy. These results show that this interferometer has advantages of simultaneously measuring straightness error and the relative position with high precision, and a compact structure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative assessment of sample stiffness and sliding friction from force curves in atomic force microscopy

It has long been recognized that the angular deflection of an atomic force microscope (AFM) cantilever under ''normal'' loading conditions can be profoundly influenced by the friction between the tip and the surface. It is shown here that a remarkably quantifiable hysteresis occurs in the slope of loading curves whenever the normal flexural stiffness of the AFM cantilever is greater than that of the sample. This situation arises naturally in cantilever-on-cantilever calibration, but also when trying to measure the stiffness of nanomechanical devices or test structures, or when probing any type of surface or structure that is much more compliant along the surface normal than in transverse directions. Expressions and techniques for evaluating the coefficient of sliding friction between the cantilever tip and sample from normal force curves, as well as relations for determining the stiffness of a mechanically compliant specimen are presented. The model is experimentally supported by the results of cantilever-on-cantilever spring constant calibrations. The cantilever spring constants determined here agree with the values determined using the NIST electrostatic force balance within the limits of the largest uncertainty component, which had a relative value of less than 2.5%. This points the way for quantitative testing of micromechanical and nanomechanical components, more accurate calibration of AFM force, and provides nanotribologists access to information about contact friction from normal force curves.

36 MATERIALS SCIENCE↗

Mirror profile optimization for nano-focusing KB mirror

A KB focusing mirror width profile has been optimized to achieve nano-focusing for the nano-imaging end-station ID22NI at the ESRF. The complete mirror and flexure bender assembly has been modeled in 3D with finite element analysis using ANSYS. Bender stiffness, anticlastic effects and geometrical non-linear effects have been considered. Various points have been studied: anisotropy and crystal orientation, stress in the mirror and bender, actuator resolution and the mirror-bender adhesive bonding... Extremely high performance of the mirror is expected with residual slope error smaller than 0.6 {mu}rad, peak-to-valley, compared to the bent slope of 3000 {mu}rad.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Thrust stand for vertically oriented electric propulsion performance evaluation

A variation of a hanging pendulum thrust stand capable of measuring the performance of an electric thruster operating in the vertical orientation is presented. The vertical orientation of the thruster dictates that the thruster must be horizontally offset from the pendulum pivot arm, necessitating the use of a counterweight system to provide a neutrally stable system. Motion of the pendulum arm is transferred through a balance mechanism to a secondary arm on which deflection is measured. A noncontact light-based transducer is used to measure displacement of the secondary beam. The members experience very little friction, rotating on twisting torsional pivots with oscillatory motion attenuated by a passive, eddy-current damper. Displacement is calibrated using an in situ thrust calibration system. Thermal management and self-leveling systems are incorporated to mitigate thermal and mechanical drifts. Gravitational force and torsional spring constants associated with flexure pivots provide restoring moments. An analysis of the design indicates that the thrust measurement range spans roughly four decades, with the stand capable of measuring thrust up to 12 N for a 200 kg thruster and up to approximately 800 mN for a 10 kg thruster. Data obtained from calibration tests performed using a 26.8 lbm simulated thruster indicated a resolution of 1 mN on 100 mN level thrusts, while those tests conducted on a 200 lbm thruster yielded a resolution of roughly 2.5 mN at thrust levels of 0.5 N and greater.

42 ENGINEERING↗

6.5 kW, Yb:YAG Ceramic Thin Disk Laser

The operation of a 1030 nm, single, thin disk laser which produced 6.5 kW of laser output power with 57 percent slope efficiency is reported. The Yb:YAG ceramic gain element is 200 {mu}m thick, bonded to a 1 mm, undoped, ceramic YAG cap. The gain element is pumped by diodes at 940 nm. The maximum incident pump intensity was 5 kW/cm{sup 2}, which yielded an output intensity of 2.6 kW/cm{sup 2} of multimode laser radiation. Rigrod analysis suggests that the laser operates with inhomogeneous gain saturation. This is attributed to the enhanced, spatial-hole-burning effect when the gain element is adjacent to a mirror. The pump threshold and output intensities were independent of pump spot size, which validates area scaling. Observed thermal lensing contributions include thermal-expansion-induced disk flexure, pump-edge-induced temperature profile and a strong thermal imprint of the cooling nozzle due to the direct jet impingement on the high reflection (HR) coated side. Weak absorption of the 1030 nm intracavity intensity in the undoped cap and/or the anti-reflection (AR) coating led to excess heating that limited the extracted power intensity. These results suggest ceramic Yb:YAG can be scaled to higher powers using optimized thin disk elements and improved disk thermal management techniques.

36 MATERIALS SCIENCE↗

Analytical model of the temperature dependent properties of microresonators immersed in a gas

A comprehensive theoretical model of microresonators immersed in a viscous gas of varying temperature is presented and verified by experiments. Analytical expressions for both the temperature dependent resonant frequency and quality factor of the first flexural eigenmode were derived extending Sader's theory of viscous damping to small temperature variations. The model provides useful implications for the thermal stabilization of microresonators immersed in a gas as well as for the reduction in the influence of the temperature dependent gas properties on the resonant frequency. Finally, an analytical expression is deduced for the mass detection capability of a microresonator that undergoes temperature variations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Durability of waste glass flax fiber reinforced mortar

The main concern for natural fibre reinforced mortar composites is the durability of the fibres in the alkaline environment of cement. The composites may undergo a reduction in strength as a result of weakening of the fibres by a combination of alkali attack and fibre mineralisation. In order to enhance the durability of natural fiber reinforced cement composites several approaches have been studied including fiber impregnation, sealing of the matrix pore system and reduction of matrix alkalinity through the use of pozzolanic materials. In this study waste glass powder was used as a pozzolanic additive to improve the durability performance of flax fiber reinforced mortar (FFRM). The durability of the FFRM was studied by determining the effects of ageing in water and exposure to wetting and drying cycles; on the microstructures and flexural behaviour of the composites. The mortar tests demonstrated that the waste glass powder has significant effect on improving the durability of FFRM.

36 MATERIALS SCIENCE↗

Theoretical and experimental studies of combined therapy of tumours with application of ultrasound

The article presents novel method of combined therapy of superficial tumours based on excitation of ultrasonic waves in tumour tissues by means of ring-shaped waveguide with subsequent radiotherapy and results of its theoretical and experimental studies. Harmonic analysis of forced flexural vibration of the waveguide using ANSYS software and APDL (ANSYS Parametric Design Language) was implemented for determination of waveguide geometric parameters providing its resonance for the given excitation frequency. The developed finite element model accounts for interaction between the waveguide and tumour tissue as well as initial prestressing of tissue radially compressed by the waveguide. Resonant curves of the waveguide in terms of its thickness and diameter are calculated and presented. Experimental studies were performed in vivo on white rats with inoculated sarcoma M-1 tumours. Treatment was performed using ultrasound with frequency 22-23 kHz and intensity about 2 W/cm{sup 2}. Ultrasonic treatment was proved to be an efficient modifier of radiotherapy.

60 APPLIED LIFE SCIENCES↗

Three-dimensional vector electrochemical strain microscopy

Three-dimensional vector imaging of bias-induced displacements of surfaces of ionically conductive materials using electrochemical strain microscopy (ESM) is demonstrated for model polycrystalline LiCoO2surface. We demonstrate that resonance enhanced imaging using band excitation detection can be performed both for out-of-plane and in-plane response components at flexural and torsional resonances of the cantilever, respectively. The image formation mechanism in vector ESM is analyzed and relationship between measured signal and grain orientation is discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Photochemical deterioration of the organic/metal contacts in organic optoelectronic devices

We study the effect of exposure to light on a wide range of organic/metal contacts that are commonly used in organic optoelectronic devices and found that irradiation by light in the visible and UV range results in a gradual deterioration in their electrical properties. This photo-induced contact degradation reduces both charge injection (i.e., from the metal to the organic layer) and charge extraction (i.e., from the organic layer to the metal). X-ray photoelectron spectroscopy (XPS) measurements reveal detectable changes in the interface characteristics after irradiation, indicating that the photo-degradation is chemical in nature. Changes in XPS characteristics after irradiation suggests a possible reduction in bonds associated with organic-metal complexes. Measurements of interfacial adhesion strength using the four-point flexure technique reveal a decrease in organic/metal adhesion in irradiated samples, consistent with a decrease in metal-organic bond density. The results shed the light on a new material degradation mechanism that appears to have a wide presence in organic/metal interfaces in general, and which likely plays a key role in limiting the stability of various organic optoelectronic devices such as organic light emitting devices, organic solar cells, and organic photo-detectors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A two-axis in-plane motion measurement system based on optical beam deflection

Measurement of in-plane motion with high resolution and large bandwidth enables model-identification and real-time control of motion-stages. This paper presents an optical beam deflection based system for measurement of in-plane motion of both macro- and micro-scale motion stages. A curved reflector is integrated with the motion stage to achieve sensitivity to in-plane translational motion along two axes. Under optimal settings, the measurement system is shown to theoretically achieve sub-angstrom measurement resolution over a bandwidth in excess of 1 kHz and negligible cross-sensitivity to linear motion. Subsequently, the proposed technique is experimentally demonstrated by measuring the in-plane motion of a piezo flexure stage and a scanning probe microcantilever. For the former case, reflective spherical balls of different radii are employed to measure the in-plane motion and the measured sensitivities are shown to agree with theoretical values, on average, to within 8.3%. For the latter case, a prototype polydimethylsiloxane micro-reflector is integrated with the microcantilever. The measured in-plane motion of the microcantilever probe is used to identify nonlinearities and the transient dynamics of the piezo-stage upon which the probe is mounted. These are subsequently compensated by means of feedback control.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗