Improved Sizing of Impact Damage in Composites Based on Thermographic Response

Impact damage in thin carbon fiber reinforced polymer composites often results in a relatively small region of damage at the front surface, with increasing damage near the back surface. Conventional methods for reducing the pulsed thermographic responses of the composite tend to underestimate the size of the back surface damage, since the smaller near surface damage gives the largest thermographic indication. A method is presented for reducing the thermographic data to produce an estimated size for the impact damage that is much closer to the size of the damage estimated from other NDE techniques such as microfocus x-ray computed tomography and pulse echo ultrasonics. Examples of the application of the technique to experimental data acquired on specimens with impact damage are presented. The method is also applied to the results of thermographic simulations to investigate the limitations of the technique.

Winfree, William P.↗

Development of an Indexing Media Filtration System for Long Duration Space Missions

The effective maintenance of air quality aboard spacecraft cabins will be vital to future human exploration missions. A key component will be the air cleaning filtration system which will need to remove a broad size range of particles including skin flakes, hair and clothing fibers, other biological matter, and particulate matter derived from material and equipment wear. In addition, during surface missions any extraterrestrial planetary dust, including dust generated by near-by ISRU equipment, which is tracked into the habitat will also need to be managed by the filtration system inside the pressurized habitat compartments. An indexing media filter system is being developed to meet the demand for long-duration missions that will result in dramatic increases in filter service life and loading capacity, and will require minimal crew involvement. These features may also benefit other closed systems, such as submarines, and remote location terrestrial installations where servicing and replacement of filter units is not practical. The filtration system consists of three stages: an inertial impactor stage, an indexing media stage, and a high-efficiency filter stage, packaged in a stacked modular cartridge configuration. Each stage will target a specific range of particle sizes that optimize the filtration and regeneration performance of the system. An 1/8th scale and full-scale prototype of the filter system have been fabricated and have been tested in the laboratory and reduced gravity environments that simulate conditions on spacecrafts, landers and habitats. Results from recent laboratory and reducegravity flight tests data will be presented.

Filtration↗

Through-Thickness Tensile Properties of Triaxial Braided Composites

The through-thickness strength of triaxial braided composites was measured using thin specimens bonded to metallic tabs. Despite providing reasonable engineering estimates of the bulk properties, some test specimen limitations were noted: For strong epoxies, significant shear and tensile stresses occur and induce failure between the first layer and bond-line; the strains over much of the exterior are ~10% lower than interior strains, which are representative of the nominal state; and failure often occurred near or along the adhesive bond line. These interference were partially overcome by adding a large radius to the gage section. Based on the finite element analysis and experimental measurements, the nominal elastic modulus and Poisson's ratio are E(sub 33) = 10.7 GPa and v(sub 31) = 0.08 for the three triaxial braided composites tested. Strengths vary from 14 to 40 MPa depending on the resin. Relative to the in-plane properties, the through thickness modulus, fracture strength, failure strain, and Poisson's ratio are 1/5th, 1/30th, 1/6th, and 1/4th. Interlaminar failure occurred with varying degrees of fiber tear out along with little damage to axial tows, resulting is a smooth undulating fracture surface. Post cure temperature excursions to 177 deg C (350 deg F) had little effect on elastic constants but reduced the strength E862 based composites severely. The strength of PR520 and 5208 based composites increased.

composite↗

Experimental Observations of Damage States in Unnotched and Notched 3D Orthogonal Woven Coupons Loaded in Tension

This paper describes a series of unnotched and notched tensile tests on two 3D orthogonal woven architectures. Dog bone specimens were used for the unnotched tests, and open-hole specimens were used for the notched tests. For each architecture and test type, two specimens were loaded under monotonic displacement control to failure and two specimens were incrementally loaded to failure in five steps. X-ray computed tomography (CT) was used to characterize the woven architecture and defects on each specimen prior to testing. Digital image correlation (DIC) images were obtained from both sides of the specimen throughout the loading and unloading. Acoustic emission (AE) data were also continuously acquired throughout the loading. For the incremental tests, X-ray CT was used to document the damage progression after each load increment. The damage progression was analyzed based on the results from these three techniques. The results for both architectures and test specimens followed a pattern where matrix cracks formed at the surface perpendicular to the tensile load direction. New surface cracks formed continuously throughout the loading and cracks extended in depth and width. In general, fiber failure was not detected until specimen failure.

Wade C Jackson↗

Progress on the Development of a Step Height Sensor for the BOLT Flight Vehicle

This presentation will summarize progress on the development of a step height sensor for the BOLT flight vehicle. Two methods have been proposed to measure the step size in this effort.The first method involves the application of miniaturized camera embedded in the flight vehicle that views the step through a rearward-facing port (shown in Fig. 1a inset). The second method involves the application of a linear fiber optic array bundle to measure the intensity of light reflected back from the aft body step (concept shown in Fig. 1b). Preliminary testing with the miniaturized camera has been performed in the lab and shows that displacements of ≤10 μm can be measured using this method. Final testing with both methods will be performed on the test stand shown in Fig. 1a. This test stand will include a fine adjustment vertical translation stage that will be used to adjust the step height in steps of 1-2 μm. A high-magnification imaging system will also be used to verify the step height. The miniaturized camera and linear fiber optic array bundle will be mounted in one of several port holes with varying degrees of inclination relative to the top surface in the opposing aft-section slab. BOLT flight vehicle details and information on the steps can be found in Ref. [1].

BOLT↗

A study to improve the mechanical properties of silicon carbide ribbon fibers

Preliminary deposition studies of SiC ribbon on a carbon ribbon substrate showed that the dominant strength limiting flaws were at the substrate surface. Procedures for making the carbon ribbon substrate from polyimide film were improved, providing lengths up to 450 meters (1,500 ft.) of flat carbon ribbon substrate 1,900 microns (75 mils) wide by 25 microns (1 mil) thick. The flaws on the carbon ribbon were smaller and less frequent than on carbon ribbon used earlier. SiC ribbon made using the improved substrate, including a layer of pyrolytic graphite to reduce further the severity of substrate surface flaws, showed strength levels up to the 2,068 MPa (300 Ksi) target of the program, with average strength levels over 1,700 MPa (250 Ksi) with coefficient of variation as low as 10% for some runs.

Debolt, H. E.↗

Modeling of the Ablation of Fibrous Materials in the Knudsen Regime

During atmospheric entry of planetary probes, the thermal protection system (TPS) of the probe is exposed to high temperatures under low pressures. In these conditions, carbonous TPS materials undergo gasification in the Knudsen regime leading to mass loss and wall recession called ablation. This work aims to improve the understanding of materiaVenvironment interactions through a study of the coupling between carbon dioxide transport in the Knudsen regime, heterogeneous oxidation of carbon, and sutface recession. A 3D Monte-Carlo simulation tool is used for this study. The fibrous architecture of the materiils, consisting of high porosity random array of carbon fibers, is numerically reproduced on a 3D Cartesian grid. Mass transport in the Knudsen regime from the boundary layer to the surface, and inside this porous material is simulated by random walk. A reaction probability is used to simulate the heterogeneous oxidation reaction. The surface recession is followed by front tracking using a simplified marching cube approach. The output data of the simulations are ablation velocity and dynamic evolution of the material porosity. A parametric study is carried out to analyze the material behavior as a function of Knudsen number for the porous media (length of the mean free path compared to the mean pore diameter) and the intrinsic reactivity of the carbon fibers. The results enable extrapolation of laboratory experimental data to actual entry conditions.

Lachaud, J.↗

Extracting single fiber transverse and shear moduli from off-axis misalignment fiber tensile testing

Small diameter (<100 μm) fibers (e.g. carbon fibers, Kevlar, and fiberglass) and wires (e.g. ultrafine copper and aluminum wires) are frequently used in many different engineering applications, such as for light weighting structures, electromagnetic shielding for aircraft/infrastructure/EVs, vibration damping, biological sensors, aerospace electrical devices, and electric windings just to name a few. Due to the manufacturing process, the fibers and wires are pulled and stretched to produce a preferential alignment. Therefore, thin fibers and wires typically display different properties along the length of the fiber as opposed to their cross section and many fibers/wires are considered transversely isotropic. The axial properties of fibers/wires can be ascertained via tensile testing of single-filaments or fiber tows, but the radial properties require much more effort to measure. Knowing these properties is important for the accurate prediction of micromechanical models and manipulation of fibers during micromanufacturing. In this paper, a new technique was developed to determine the transverse/shear moduli and strength of a material by conducting tensile tests of the material at increasing misalignment angles from the tensile axis. Due to the transversely isotropic nature of the material, the transverse/shear moduli and strength influence the experimental results recorded by the test machine to different degrees based on the amount of misalignment in the test setup. An equation was derived to determine the influence of each of the material properties based on the misalignment angle by manipulating the stiffness matrix for transversely isotropic materials using the transformation matrices. Then, curve fitted coefficients were used to identify the material properties. Here, the strengths were similarly determined by curve fitting an off-axis Tsai-Hill failure criteria to determine the influence of transverse, shear, and tensile strengths based on the complex loading condition provided by the off-axis tensile test. Zoltek Panex 35 carbon fibers were used to demonstrate this new technique and the determined properties were then compared to those obtained from nanoindentation and from literature. Fracture surfaces provide insight into the different failure mechanisms at various misalignment angles.

36 MATERIALS SCIENCE↗

Method and apparatus for white-light dispersed-fringe interferometric measurement of corneal topography

An novel interferometric apparatus and method for measuring the topography of aspheric surfaces, without requiring any form of scanning or phase shifting. The apparatus and method of the present invention utilize a white-light interferometer, such as a white-light Twyman-Green interferometer, combined with a means for dispersing a polychromatic interference pattern, using a fiber-optic bundle and a disperser such as a prism for determining the monochromatic spectral intensities of the polychromatic interference pattern which intensities uniquely define the optical path differences or OPD between the surface under test and a reference surface such as a reference sphere. Consequently, the present invention comprises a snapshot approach to measuring aspheric surface topographies such as the human cornea, thereby obviating vibration sensitive scanning which would otherwise reduce the accuracy of the measurement. The invention utilizes a polychromatic interference pattern in the pupil image plane, which is dispersed on a point-wise basis, by using a special area-to-line fiber-optic manifold, onto a CCD or other type detector comprising a plurality of columns of pixels. Each such column is dedicated to a single point of the fringe pattern for enabling determination of the spectral content of the pattern. The auto-correlation of the dispersed spectrum of the fringe pattern is uniquely characteristic of a particular optical path difference between the surface under test and a reference surface.

Hochberg, Eric B.↗

Shadowgraph Study of Gradient Driven Fluctuations

A fluid or fluid mixture, subjected to a vertical temperature and/or concentration gradient in a gravitational field, exhibits greatly enhanced light scattering at small angles. This effect is caused by coupling between the vertical velocity fluctuations due to thermal energy and the vertically varying refractive index. Physically, small upward or downward moving regions will be displaced into fluid having a refractive index different from that of the moving region, thus giving rise to the enhanced scattering. The scattered intensity is predicted to vary with scattering wave vector q, as q(sup -4), for sufficiently large q, but the divergence is quenched by gravity at small q. In the absence of gravity, the long wavelength fluctuations responsible for the enhanced scattering are predicted to grow until limited by the sample dimensions. It is thus of interest to measure the mean-squared amplitude of such fluctuations in the microgravity environment for comparison with existing theory and ground based measurements. The relevant wave vectors are extremely small, making traditional low-angle light scattering difficult or impossible because of stray elastically scattered light generated by optical surfaces. An alternative technique is offered by the shadowgraph method, which is normally used to visualize fluid flows, but which can also serve as a quantitative tool to measure fluctuations. A somewhat novel shadowgraph apparatus and the necessary data analysis methods will be described. The apparatus uses a spatially coherent, but temporally incoherent, light source consisting of a super-luminescent diode coupled to a single-mode optical fiber in order to achieve extremely high spatial resolution, while avoiding effects caused by interference of light reflected from the various optical surfaces that are present when using laser sources. Results obtained for a critical mixture of aniline and cyclohexane subjected to a vertical temperature gradient will be presented. The sample was confined between two horizontal parallel sapphire plates with a vertical spacing of 1 mm. The temperatures of the sapphire plates were controlled by independent circulating water loops that used Peltier devices to add or remove heat from the room air as required. For a mixture with a temperature gradient, two effects are involved in generating the vertical refractive index gradient, namely thermal expansion and the Soret effect, which generates a concentration gradient in response to the applied temperature gradient. For the aniline/cyclohexane system, the denser component (aniline) migrates toward the colder surface. Consequently, when heating from above, both effects result in the sample density decreasing with altitude and are stabilizing in the sense that no convective motion occurs regardless of the magnitude of the applied temperature gradient. The Soret effect is strong near a binary liquid critical point, and thus the dominant effect is due to the induced concentration gradient. The results clearly show the divergence at low q and the predicted gravitational quenching. Results obtained for different applied temperature gradients at varying temperature differences from the critical temperature, clearly demonstrate the predicted divergence of the thermal diffusion ratio. Thus, the more closely the critical point is approached, the smaller becomes the temperature gradient required to generate the same signal. Two different methods have been used to generate pure concentration gradients. In the first, a sample cell was filled with a single fluid, ethylene glycol, and a denser miscible fluid, water, was added from below thus establishing a sharp interface to begin the experiment. As time went on the two fluids diffused into each other, and large amplitude fluctuations were clearly observed at low q. The effects of gravitational quenching were also evident. In the second method, the aniline/cyclohexane sample was used, and after applying a vertical temperature gradient for several hours, the top and bottom temperatures were set equal and the thermal gradient died on a time scale of seconds, leaving the Soret induced concentration gradient in place. Again, large-scale fluctuations were observed and died away slowly in amplitude as diffusion destroyed the initial concentration gradient.

Cannell, David↗

Distributed Magnetic Field and Temperature Monitoring for Superconducting Radio Frequency Cavities

The overall objective of the proposed Phase I program was to design, construct and demonstrate a fiber optic sensing system capable of providing temperature and magnetic field measurements with an enhanced spatial resolution that can be implemented over a large surface area (cryomodules) to survey superconducting radio frequency cavities and magnets. A magnetic field sensor capable of detecting fluxes on the order of 1 μT is required to detect the distribution of trapped flux on the cavity surface. A unique distributed magnetic field sensor was successfully designed and constructed to demonstrate the detection of magnetic fluxes less than 500 nT. The sensor leveraged the ultra-high sensitivity of Sentek’s picoDAS to measure the magnetostriction induced vibrations in a commercially available Metglas 2605 SC ribbon that was in physical contact with sensing fiber. Static magnetic fields were detected by applying an alternating current a copper wire proximate to the Metglas 2605SC ribbon to create an AC bias magnetic field. In an alternative approach, an AC bias magnetic field was applied to a special magnetic field sensing fiber with Metglas 2605SC cladding successfully detect a magnetic field flux of a 3 μT. Exhaustive testing was performed to characterize the dependency of sensor response on the direction of the applied magnetic field. Although the special sensing fiber based magnetic field sensor did not exhibit an observable dependence on the direction of the magnetic field, the Metglas 2605SC ribbon sensor exhibited a clear directional dependence. A wide variety of polymer materials were evaluated to enhance the temperature response of an FBG based sensor at cryogenic temperatures. The processing and performance challenges provided the motivation to develop a new simple cryogenic temperature sensor that uses a commercially available fiber optic splice protector. The EVA hot melt tube that becomes adhered to the optical fiber and the polyolefin outer tube that shrinks upon heating in the fusion splicer heater provide the high thermal expansion coefficient necessary to impart a significant strain on the FBG when exposed to cryogenic temperatures. The temperature sensitivity (Δ𝜆𝐵𝑟𝑎𝑔𝑔~ 62 𝑝𝑝𝑚/℃) of the FBG-based sensor was on par with the best reported to date. The simple design, use of readily available cost-effective materials, and well-established processing techniques lends this approach to the creation of hundreds to thousands of temperature sensors on one single optical fiber length. The inherently small form factor also allows for co-location with the distributed magnetic field sensor. In preparation for field testing of the prototype sensing system at the Jefferson Labs in potential Phase II program, several different cable designs were evaluated to package the sensors. The preliminary successful demonstration of fully functional sensing cables provides the foundation for subsequent development efforts to advance the Technology Readiness Level of the technology. The technical feasibility of the proposed approach was successfully demonstrated in this Phase I effort.

43 PARTICLE ACCELERATORS↗

Textile-Grade Carbon Fiber-Reinforced Polycarbonate Composites: Effect of Epoxy Sizing

In this work, epoxy-sized textile-grade polyacrylonitrile (PAN) carbon fiber (TCF) with 450 K filaments (CFTF, ORNL) was reinforced in the polycarbonate (PC) matrix using a compression molding technique. The epoxy sizing effect on the surface, thermal, and mechanical properties of TCF–PC was investigated. X-ray photoelectron spectroscopy and Fourier transform infrared spectroscopy results of the TCF–PC composite show the absence of an oxirane group (epoxy-sized TCF), which suggests a covalent bond formation between the oxirane ring and carbonyl groups from TCF and PC. Dynamic mechanical analysis results confirm a strong immobilized interface (b > 1) present between TCF and PC. The tensile, flexure, compression, and interlaminar shear strength of TCF–PC composites were 323 ± 53, 371 ± 31, 397 ± 87, and 36 ± 3 MPa, correspondingly. The fracture analysis through scanning electron microscopy shows good wettability between TCF and the PC matrix which validates the results obtained from surface and thermal characterization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fiber-Optic Sensor Would Detect Movements Of Shaft

Fiber-optic sensor senses both rotational speed and axial displacement of shaft in motor, pump, or other rotating machine. Does not require magnetic materials, notches, or grooves in shaft. Required modification of shaft is etching or plating surface to make ring black around half circumference and reflective around other half along short length at one end or some other convenient location. Triangular bundle of sending and receiving optical fibers aimed at black/reflective ring on shaft. Frequency and amplitude of output pulses of fiber-optic probe indicates rotational frequency and axial position of shaft.

Roschak, Edmund J.↗

Prediction of Chemical Vapor Deposition Rates on Monofilaments and Its Implications for Fiber Properties

Deposition rates are predicted in a cylindrical upflow reactor designed for chemical vapor deposition (CVD) on monofilaments. Deposition of silicon from silane in a hydrogen carrier gas is chosen as a relevant example. The effects of gas and surface chemistry are studied in a two-dimensional axisymmetric flow field for this chemically well-studied system. Model predictions are compared to experimental CVD rate measurements. The differences in some physical and chemical phenomena between such small diameter (about 150 microns) fiber substrates and other typical CVD substrates are highlighted. The influence of the Soret mass transport mechanism is determined to be extraordinarily significant. The difficulties associated with the accurate measurement and control of the fiber temperature are discussed. Model prediction sensitivities are investigated with respect to fiber temperatures, fiber radii, Soret transport, and chemical kinetic parameters. The implications of the predicted instantaneous rates are discussed relative to the desired fiber properties for both the batch and the continuous processes.

Gokoglu, S. A.↗

Energy-efficient carbon capture from industrial point sources via commercially available green solvent and hollow fiber membrane contactors

Solvent-based absorption systems have emerged in the carbon capture space due to their high absorption capacities, reusability, and favorable energy requirements. Using diethyl sebacate as a solvent for pre- and post-combustion carbon capture has advantages over other solvents, including high hydrophobicity, low viscosity, low vapor pressure, high CO 2 solubility, high CO 2 selectivity, and being commercially available in large quantities. Despite these advantageous properties, the use of diethyl sebacate as a solvent for post-combustion carbon capture has not been studied in detail. To examine the capability of diethyl sebacate, a scalable, energy-efficient, hollow fiber membrane (microporous polypropylene and polyvinylidene fluoride) contactor (HFMC)-based process with low-cost and high surface area is investigated. A purity of 95.3 % CO 2 with 46 % recovery in one absorption stage was achieved, with a permeate flux over one magnitude greater than using a deep eutectic solvent in the same system. Technoeconomic analysis determined a ∼ 0.8 GJ per ton of CO 2 at a processing cost of ∼$93 per ton of CO 2 . Results from this work underscore the potential for utilizing green solvents in HFMC-based separation processes for effective carbon capture and provide a pathway towards practical deployment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

FY 2026 Midyear Report: Seismic Monitoring of Underground Vibration Sources Using Distributed Acoustic Sensing and Seismometers

Safeguards-relevant temporal changes in underground facilities can be observed using geophysical monitoring techniques. Seismic waves, in particular, provide valuable insights into subsurface activities and can serve as an important tool for detecting anomalous events that may indicate containment breaches at geological repositories. This midyear report summarizes ongoing efforts to automatically and rapidly detect and locate anomalous vibration signals that could be indicative of potential containment breaches. Previous work during FY25 focused on compiling continuous seismic datasets from two underground sites and developing a database of continuous waveforms and ground-truth event data derived from multiple sensing modalities. Building on this foundation, we are adapting anomaly detection and geolocation algorithms to explore methods for monitoring underground activities using two relatively low-maintenance sensing technologies: a dense surface geophone array deployed at the Pleasant Gap mine in Pennsylvania, and a three-dimensional fiber-optic cable array for distributed acoustic sensing (DAS) installed in the subsurface at the Sanford Underground Research Facility (SURF) in South Dakota. This report summarizes work conducted during the first two quarters of FY26, during which we refined a dynamic power spectral density (PSD)-based detector, applied it independently to each geophone station, and then combined the per‑station detections with density-based spatial clustering of applications with noise (DBSCAN) to cluster events and produce spatial maps over a nine‑day interval. In addition, we outline plans for a field trial at the Waste Isolation Pilot Plant (WIPP) in New Mexico to compare traditional seismic monitoring approaches with DAS techniques and to evaluate the benefits of combined data analysis. Activities during the past two quarters have included the preparation and submission of a Field Test Plan to WIPP for approval, as well as submission to headquarters for review and feedback.

58 GEOSCIENCES↗

Off-axis tensile properties and fracture in a unidirectional graphite/polyimide composite (Celion 6000/PMR 15)

Tensile properties of unidirectional Celion 6000 graphite/PMR 15 polyimide composites prepared by hot molding and cold molding processes were measured at room temperature and 316 C, the upper use temperature of the polyimide resin, at both 45 and 90 deg to the fiber axis. The resulting fractures were characterized by scanning electron microscopy and materialographic techniques. Variation in tensile properties with processing history occurred in the elastic modulus and strain to failure for specimens loaded at 90 deg at 316 C, and in the fracture stress, and hence the in-plane shear stress, for those loaded at 45 deg at room temperature. Significant plastic deformation was observed in the 45 deg orientation at 316 C for material produced by both processing methods. In general, fracture occurred by both failure within the matrix and at the fiber-matrix interface; the degree of interfacial failure increased with temperature. Secondary cracking below the primary fracture surface was also observed.

Harper, J.↗

Evaluation of the split cantilever beam for Mode 3 delamination testing

A test rig for testing a thick split cantilever beam for scissoring delamination (mode 3) fracture toughness was developed. A 3-D finite element analysis was conducted on the test specimen to determine the strain energy release rate, G, distribution along the delamination front. The virtual crack closure technique was used to calculate the G components resulting from interlaminar tension, GI, interlaminar sliding shear, GII, and interlaminar tearing shear, GIII. The finite element analysis showed that at the delamination front no GI component existed, but a GII component was present in addition to a GIII component. Furthermore, near the free edges, the GII component was significantly higher than the GIII component. The GII/GIII ratio was found to increase with delamination length but was insensitive to the beam depth. The presence of GII at the delamination front was verified experimentally by examination of the failure surfaces. At the center of the beam, where the failure was in mode 3, there was significant fiber bridging. However, at the edges of the beam where the failure was in mode 3, there was no fiber bridging and mode 2 shear hackles were observed. Therefore, it was concluded that the split cantilever beam configuration does not represent a pure mode 3 test. The experimental work showed that the mode 2 fracture toughness, GIIc, must be less than the mode 3 fracture toughness, GIIIc. Therefore, a conservative approach to characterizing mode 3 delamination is to equate GIIIc to GIIc.

Martin, Roderick H.↗