Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “exposure time”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Physical examinations of workers exposed to trichlorotrifluoroethane.

A group of 50 workers, exposed for an average of 2.77 years in an environment, samples of which contained from 46 to 4700 ppm of trichlorotrifluoroethane (Freon 113), was examined. There were no subjective complaints, other than one case of dryness of the skin, referable to this occupational exposure. At this time, it is our opinion that there is no evidence of adverse effects from exposure to trichlorotrifluoroethane under the conditions encountered by these personnel. We believe that continued, periodic, follow-up examinations of these workers will be helpful in further evaluating any possible long-range effects of this material.

Imbus, H. R.↗

ROSAT observation program

In this annual progress report (November 1, 1993 to October 31, 1994), the geminga pulsar was observed by the ROSAT PSPC for 37,000 s in September 1993, in order to make a more detailed study than was previously possible of the pulse profile and two-component spectrum, and to do phase-resolved spectroscopy. This exposure was 2.5 times longer than the original discovery observation. In addition, a shorter 4,000 s exposure was made in October 1992, simultaneously with a GRO observation of Geminga, in order to verify the absolute phasing of the X-ray and gamma-ray peaks. We verified that the spectrum can be described as the sum of two black bodies, whose temperatures are 6 x 10(exp 5) K and 3 - 4 x 10(exp 6) K, with the latter covering 3 x 10(exp -5) the area of the former. The pulse profiles indicate that the intensity of the two emitting regions peak is approximately 90 deg out of phase in rotation, but that the temperatures are otherwise independent of phase. An improved estimate of the distance can be made from the cooler (larger) blackbody component, yielding d = 440 +/- 120 pc. Another program of this report was to obtain PSPC spectra of an important class of Seyfert galaxies which have narrow lines and stron permitted Fe II emission. Sometines called I Zw 1 objects, or narrow-line Seyfert 1s, they are crucial to our understanding of Seyfert classification and models of Seyfert unification. We observed four new objects and, in addition, obtained data on 17 more from the ROSAT archive. A third program combined PSPC and HRI observations of selected Seyfert galaxies which have unusual and variable spectra. The purpose was to disentangle diffuse X-ray emission from the nuclear source, in order to properly interpret the soft X-ray spectral shapes in terms of partial covering and/or warm-absorber models. The targets of the program are NGC 3516, NGC 3227, and NGC 7314. So far, we have only performed a dtailed analysis on NGC 3516. The fourth program of this report is the NGC 1672, the second brightest Seyfert galaxy and one or the original 'composite' Seyfert/starburst galaxies which have evidence for both Seyfert activity and H II regions in their optical spectra. It is one of the lowest luminosity Seyfert 2 galaxies that can be studied in detail.

Halpern, Jules P.↗

Effect of frequency and applied voltage of an atmospheric-pressure dielectric-barrier discharge on breakdown and hydroxyl-radical generation with a liquid electrode

This work examines the effect of the frequency and peak applied voltage on hydroxyl-radical generation in a dielectric-barrier plasma discharge between a metallic needle electrode and one electrode covered with dielectric. The authors examine a system that can expose up to 96 liquid samples in an automated fashion without human intervention beyond setting the initial software configuration. Then, hydroxylradical concentration, measured through coumarin fluorescence, was measured for 5 s plasma exposures generated under different highvoltage conditions with frequencies from 2 to 16 kHz and amplitudes from 4 to 9 kV. Their results show that an increase in frequency and/or applied voltage, within the range prescribed above and the limits of the high-voltage power supply, can yield up to a 150% increase in fluorescence with an equivalent hydroxyl-radical increase. Applications using typical previous methods, such as the Fenton Reaction, are limited in that they continuously generate hydroxyl radicals over millisecond and longer intervals. These results establish the electrical parameters that can now be applied to polymers, like proteins, which show three dimensional structures that are flexible and fluctuate on a microsecond and nanosecond time scale, with hydroxyl-radical generation on this time scale using this device. Additionally, plasma exposures may be optimized for a great variety of proteins, devices and techniques, where hydroxyl-radical generation is of utmost importance, reducing exposure time and potential subjection of samples to harmful side effects.

42 ENGINEERING↗

Chromosome aberrations induced by high-LET radiations

Measurements of chromosome aberrations in peripheral blood lymphocytes are currently the most sensitive and reliable indicator of radiation exposure that can be used for biological dosimetry. This technique has been implemented recently to study radiation exposures incurred by astronauts during space flight, where a significant proportion of the dose is delivered by high-LET particle exposure. Traditional methods for the assessing of cytogenetic damage in mitotic cells collected at one time point after exposure may not be suitable for measuring high-LET radiation effects due to the drastic cell cycle perturbations and interphase cell death induced by this type of exposure. In this manuscript we review the recent advances in methodology used to study high-LET induced cytogenetic effects and evaluate the use of chemically-induced Premature Chromosome Condensation (PCC) as an alternative to metaphase analysis. Published data on the cytogenetic effects of in vitro exposures of high-LET radiation is reviewed, along with biodosimetry results from astronauts after short or long space missions.

ISS Project↗

Irradiation stratigraphy and depositional history of the Apollo 16 double drive tube 60009/10

We report track density frequency distributions, the fraction of high density grains and minimum track densities for 63, 1 mm wide locations in the Apollo 16 double drive tube 60009/10. From these data we conclude that there are seven irradiation strata in the core. Only one buried reworking zone extending from 50-52 cm was found and it was exposed near the surface from 4.5-9 times 10 to the 6th y with a most probable exposure period of 6 times 10 to the 6th y. There is lack of conclusive data that this zone represents a reworking zone in which case the material below 52 cm most probably was exposed in situ for 4.5 times 10 to the 6th y and developed a reworking zone approximately less than 0.5 cm. The present surface of the core has a reworking zone of 12-13 cm which was exposed from 1.3 times 10 to the 7th to 2.5 times 10 to the 8th y. The best estimate for this exposure period remains the value of approximately less than 1.25 times 10 to the 8th y determined by Bogard and Hirsch (1976). The other strata in the core appear to contain mixtures of various soil types and are not related to in situ depositional events.

Blanford, G. E.↗

Thermal Aging Effects on the Yield and Tensile Strength of 9Cr-1Mo-V (Grade 91)

The long-term exposure of 9Cr-1Mo-V (Grade 91) steel to elevated temperature can have a significant effect on reducing its yield and tensile strength. The yield and tensile strength changes, in turn, have potential implications to the assurance of the integrity of components constructed with this material over their design or intended lifetime. The ASME Boiler & Pressure Vessel Code (BPVC), Section III, Division 5 (III-5, high temperature reactors) provides tabulated reduction factors for Grade 91 yield and tensile strength as a function of exposure temperature and time up to 300,000 h. ASME BPVC III-5 s intent to extend these factors to an exposure duration of 500,000 h, the lack of available historic information to support the existing factors, and the recent development of a physics-based prediction model for ASME BPVC application are prime motivation for this study. This work describes results of the conventional time-temperature Hollomon–Jaffe parameter, strength reduction ratio prediction method using an updated, extensive Grade 91 unaged and related aged material strength database. The method, previously used by Oak Ridge National Laboratory in its evaluation of Grade 91 and likely used in development of the existing BPVC III-5 reduction factors, provides strength reduction ratio predictions useful for general component fitness-for-service assessments and for computing BPVC III-5 reduction factors as defined. Specific reduction factors to 500,000 h at 650 °C applicable to ASME BPVC III-5 are computed from the strength reduction ratios.

36 MATERIALS SCIENCE↗

DEM Measurements of Moving UV Features in Prominences

Multi-thermal features with speeds of 5-70 km/s perpendicular to the line of sight are common in the prominences which showed traceable motions. These speeds are noticeably higher than the typical speeds of 5-20 km/s observed in H-alpha data from "quiet" prominences and are more typical of "activated" prominences in which H-alpha blob speeds of up to 40 km/s have been reported. In order to make a more quantitative determination of the thermal properties of the moving features seen in the UV, we use the SOHO Cororial Diagnostic Spectrometer to take a time series of exposures from a single pointing position, providing a measurement of spectral line properties as a function of time and position along the slit. The resulting observations in lines of O III, O IV, O V, Ne IV, Ne V, Ne VI, and Ne VII allow us to calculate the differential emission measure of moving features and provide a test of models of flows in prominences.

Oegerle, William↗

Prominence Energetics Measured with SOHO/SUMER and TRACE

The mechanisms by which solar prominences are filled with plasma are still undetermined. In this study we perform a quantitative analysis of the thermal properties of moving features in prominences in order to put constraints on models of prominence formation and dynamics. In order to make such measurements of the quickly moving features seen in prominences in the W we use the SOHO/SUMER spectrograph to take a time series of exposures from a single pointing position, providing a measurement of spectral line properties as a function of time and position along the slit. temperatures from 80,000 - 1.6 million K. These measurements are combined with TRACE movies in transition region and coronal temperature bands to obtain more complete information concerning prominence structure and motions. The resulting observations allow us to analyze the thermal and kinetic energy of the moving prominence sources as functions of time.

Kucera, T.↗

Thermal Properties of Moving UV Features in Prominences

Multi-thermal features with speeds of 5-70 kilometers per second perpendicular to the line of sight are common in the prominences which showed traceable motions. These speeds are noticeably higher than the typical speeds of 5-20 kilometers per second observed in H-alpha data from "quiet" prominences and are more typical of "activated" prominences in which H-alpha blob speeds of up to 40 kilometers per second have been reported. In order to make a more quantitative determination of the thermal properties of the moving features seen in the UV, we use the SOHO instruments SUMER and CDS to take a time series of exposures from a single pointing position, providing a measurement of spectral line properties as a function of time and position along the slit. The resulting observations in lines spectral lines in a range of "transition region" temperatures allow us to analyze the thermal properties of the moving prominence sources as a function of time.

Kucera, Therese A.↗

Thermal Properties of Prominence Motions as Observed in the UV

The mechanisms by which solar prominences are filled with plasma are still undetermined. In this study we perform a quantitative analysis of the thermal properties of moving features in prominences in order to put constraints on models of prominence formation and dynamics. In order to make such measurements of quickly moving features seen in prominences in the UV we use the SOHO instruments SUMER and CDS to take a time series of exposures at a single pointing position, providing a measurement of spectral line properties as a function of time and position along the slit. The resulting observations in spectral lines in a range of 'transition region' temperatures allow us to analyze the thermal properties of the moving prominence sources as a function of time.

Kucera, T.↗

Thermal and Kinetic Properties of Motions in a Prominence Activation and Nearby Loop

We perform a quantitative analysis of the thermal properties of a prominence activation and motions in a nearby loop. In order to make measurements of the quickly moving features seen in prominences in the UV we use the SOHO/SUMER spectrograph to take a time series of exposures from a single pointing position, providing a measurement of spectral line properties as a function of time and position along the slit. The lines observed cover a broad range of temperatures from 80,000 - 1.6 million K. These measurements are combined with TRACE movies in transition region and coronal temperature bands to obtain more complete information concerning prominence structure and motions. The resulting observations allow us to analyze the thermal and kinetic energy of the moving sources as functions of time. The loop and prominence are most apparent in lines formed at temperatures below 250,000 K. We find that in most cases the temperature distribution of plasma in a moving feature changes relatively little over time periods of about 20 minutes.

Kucera, Therese↗

Prominence and Cool Loop Energetics Measured in the UV, EUV, and H-alpha

We investigate the thermal and dynamic properties of moving features in a prominence jet, a approx. 10(exp 5)K loop near a prominence channel, and an erupting prominence. In order to make measurements of the quickly moving features seen in prominences in the UV we use the SOHO/SUMER spectrograph to take a time series of exposures from a single pointing position, providing a measurement of spectral line properties as a function of time and position along the slit. The lines observed cover a broad range of temperatures from 80,000 - 1.6 million K. These measurements are combined with TRACE movies in transition region and coronal temperature bands and with ground based H-alpha data to obtain more complete information concerning prominence structure and motions. The resulting observations allow us perform DEM analysis and to calculate limits on densities, pressures, and the thermal and kinetic energies of the moving sources.

Kucera, Therese A.↗

A Simplified Diagnostic Method for Elastomer Bond Durability

A simplified method has been developed for determining bond durability under exposure to water or high humidity conditions. It uses a small number of test specimens with relatively short times of water exposure at elevated temperature. The method is also gravimetric; the only equipment being required is an oven, specimen jars, and a conventional laboratory balance.

White, Paul↗

Flux Sensor Measurement and Calibration Requirements for High-Intensity Heat Flux Applications: A Trade Study

Stakeholders of CSP and non-CSP high-intensity broadband flux measurements were surveyed and interviewed to obtain flux sensor design and calibration requirements. Existing sensor technologies and existing calibration facilities were then compared against this standard. Stakeholders require a flux sensor designed for >5,000 kW/m2 flux measurements, >1,000 life cycles, <500 ms response time, >60-minute exposure at maximum flux, and <5% measurement uncertainty. Stakeholders also require a sensor with minimal cost, short procurement lead time, and a high-intensity broadband flux calibration. Commercial CSP stakeholders primarily rely on infrared (IR) temperature measurements of receiver equipment to control CSP plant process operation, whereas CSP research and development (R&D) and non-CSP stakeholders rely on accurate flux gauge measurements for a variety of applications. It was determined that existing flux sensor technologies and calibration facilities do not comprehensively meet stakeholder needs. This study suggests a more robust circular foil gauge with a high-intensity solar flux calibration comprehensively meets stakeholder flux measurement needs. Improved circular foil gauge designs and an improved flux sensor calibration facility are discussed.

McLaughlin, Luke (ORCID:0000000303711310)↗

Quantification of contaminants associated with LDEF

The quantification of contaminants on the Long Duration Exposure Facility (LDEF) and associated hardware or tools is addressed. The purpose of this study was to provide a background data base for the evaluation of the surface of the LDEF and the effects of orbital exposure on that surface. This study necessarily discusses the change in the distribution of contaminants on the LDEF with time and environmental exposure. Much of this information may be of value for the improvement of contamination control procedures during ground based operations. The particulate data represents the results of NASA contractor monitoring as well as the results of samples collected and analyzed by the authors. The data from the tapelifts collected in the Space Shuttle Bay at Edwards Air Force Base and KSC are also presented. The amount of molecular film distributed over the surface of the LDEF is estimated based on measurements made at specific locations and extrapolated over the surface area of the LDEF. Some consideration of total amount of volatile-condensible materials available to form the resultant deposit is also presented. All assumptions underlying these estimates are presented along with the rationale for the conclusions. Each section is presented in a subsection for particles and another for molecular films.

Crutcher, E. R.↗

Time Course of Effects of Carbon Dioxide Exposure on Physical and Cognitive Performance in a Simulated Surface Extravehicular Activity Contingency Scenario

INTRODUCTION Carbon dioxide (CO 2 ) is a metabolic byproduct produced by humans that must be scrubbed from the atmosphere by environmental control and life support systems in space vehicles and spacesuits to prevent buildup. Current nominal CO 2 limits are set by NASA Standard 3001, however, limits during contingency situations are not specified. The purpose of this study was to characterize and quantify the physiological, cognitive, and self-assessed symptom and performance metrics as a function of inspired CO 2 (P I CO 2 ) during a simulated 1-hour contingency lunar EVA scenario in virtual reality (VR). METHODS Fifteen healthy subjects completed 7 simulated EVA scenarios walking on a passive treadmill for one hour breathing dry, ambient air mixed with added CO 2 in a blind, counterbalanced manner (P I CO 2 : 0, 5, 10, 15, 20, 25, 30 mmHg) simulating a 2.0 km contingency EVA walkback to a habitat on the lunar surface in the event of a CO 2 scrubber malfunction. Subjects were immersed in a Lunar VR environment and asked to maintain their walking speed between 2.1 km/h and an upper limit individually calibrated to a fixed metabolic workload of 1.3 L/min of O 2 consumption, and performed periodic cognitive tasks and continuous cardiopulmonary measurements. Self-assessments of symptoms and task performance were measured via verbal Likert-scale survey at the onset of the walkback and at 10-minute intervals thereafter. RESULTS The time course of cardiopulmonary, cognitive, and self-reported responses at each level of P I CO 2 will be presented. All 15 subjects were able to complete the 1-hr walk back task at all CO 2 levels. Physiological responses were rapid, typically within 1 to 5 minutes. No effects of time were detected for cognitive measures. Symptomatic ratings of headache, shortness of breath, and fatigue demonstrated a time-course development, reaching asymptote after 40 minutes of CO 2 exposure. DISCUSSION These findings will inform the posture of risk associated with CO 2 exposure on human health and performance during microgravity and planetary surface operations, This will help inform decisions related to space suit and environmental life support hardware requirements and EVA operational limits for contingency extravehicular activity (EVA) scenarios.

carbon dioxide↗

Evaluation of Subetadex-α-methyl, a Polyanionic Cyclodextrin Scaffold, as a Medical Countermeasure against Fentanyl and Related Opioids

Subetadex-α-methyl (SBX-Me), a modified, polyanionic cyclodextrin scaffold, has been evaluated for its utilization as a medical countermeasure (MCM) to neutralize the effects of fentanyl and related opioids. Initial in vitro toxicity assays demonstrate that SBX-Me has a nontoxic profile, comparable to the FDA-approved cyclodextrin-based drug Sugammadex. Pharmacokinetic analysis showed rapid clearance of SBX-Me with an elimination half-life of ~7.4 h and little accumulation in major organs. SBX-Me was also evaluated for its ability to counteract the effects of fentanyl, carfentanil, and remifentanil in rats. Recovery times in rats exposed to sublethal fentanyl doses were found to be shorter when treated with SBX-Me after opioid exposure. The recovery times were reduced from ~35 to ~17 min for fentanyl, ~172 to ~59 min for carfentanil, and ~18 to ~12 min for remifentanil. SBX-Me increased the elimination half-life for fentanyl and remifentanil from 5.37 to 6.42 h and 8.24 to 9.74 h, respectively. These data support SBX-Me as a solid platform from which further research can be launched for the development of a MCM against the effects of fentanyl and its analogs. Furthermore, the data suggests that SBX-Me and other analogs are attractive candidates as broad spectrum opioids targeting MCMs.

Chemistry↗

Charged Current Coherent Pion Production Cross-Section Measurement at MicroBooNE

Coherent pion production, characterized by a neutrino interacting with an entire nucleus without breaking it apart, results in a forward-going muon, pion, and a low-momentum recoil nucleus. By leveraging an improved understanding of particle identification and background parameterization, we aim to achieve a new level of sensitivity to coherent interactions at low neutrino energy. The outcome of this analysis will contribute to ongoing efforts to model neutrino nucleus interactions accurately in neutrino oscillation studies and beyond Standard Model searches in MicroBooNE and future experiments, such as DUNE. We present progress towards a measurement of charged current coherent pion production cross-section on argon with the MicroBooNE liquid argon time projection chamber detector. This measurement will use MicroBooNE's full dataset collected from the Booster Neutrino Beam with a total exposure of \( 1.3 \times 10^{21} \) protons-on-target and average neutrino energy of 0.8 GeV.

Hussain, Adil [Kansas State U.]↗