Evaluating IMRT and VMAT dose accuracy: Practical examples of failure to detect systematic errors when applying a commonly used metric and action levels

Purpose: This study (1) examines a variety of real-world cases where systematic errors were not detected by widely accepted methods for IMRT/VMAT dosimetric accuracy evaluation, and (2) drills-down to identify failure modes and their corresponding means for detection, diagnosis, and mitigation. The primary goal of detailing these case studies is to explore different, more sensitive methods and metrics that could be used more effectively for evaluating accuracy of dose algorithms, delivery systems, and QA devices.Methods: The authors present seven real-world case studies representing a variety of combinations of the treatment planning system (TPS), linac, delivery modality, and systematic error type. These case studies are typical to what might be used as part of an IMRT or VMAT commissioning test suite, varying in complexity. Each case study is analyzed according to TG-119 instructions for gamma passing rates and action levels for per-beam and/or composite plan dosimetric QA. Then, each case study is analyzed in-depth with advanced diagnostic methods (dose profile examination, EPID-based measurements, dose difference pattern analysis, 3D measurement-guided dose reconstruction, and dose grid inspection) and more sensitive metrics (2% local normalization/2 mm DTA and estimated DVH comparisons).Results: For these case studies, the conventional 3%/3 mm gamma passing rates exceeded 99% for IMRT per-beam analyses and ranged from 93.9% to 100% for composite plan dose analysis, well above the TG-119 action levels of 90% and 88%, respectively. However, all cases had systematic errors that were detected only by using advanced diagnostic techniques and more sensitive metrics. The systematic errors caused variable but noteworthy impact, including estimated target dose coverage loss of up to 5.5% and local dose deviations up to 31.5%. Types of errors included TPS model settings, algorithm limitations, and modeling and alignment of QA phantoms in the TPS. Most of the errors were correctable after detection and diagnosis, and the uncorrectable errors provided useful information about system limitations, which is another key element of system commissioning.Conclusions: Many forms of relevant systematic errors can go undetected when the currently prevalent metrics for IMRT/VMAT commissioning are used. If alternative methods and metrics are used instead of (or in addition to) the conventional metrics, these errors are more likely to be detected, and only once they are detected can they be properly diagnosed and rooted out of the system. Removing systematic errors should be a goal not only of commissioning by the end users but also product validation by the manufacturers. For any systematic errors that cannot be removed, detecting and quantifying them is important as it will help the physicist understand the limits of the system and work with the manufacturer on improvements. In summary, IMRT and VMAT commissioning, along with product validation, would benefit from the retirement of the 3%/3 mm passing rates as a primary metric of performance, and the adoption instead of tighter tolerances, more diligent diagnostics, and more thorough analysis.

61 RADIATION PROTECTION AND DOSIMETRY↗

NASA Tech Briefs, May 2011

Topics covered include: 1) Method to Estimate the Dissolved Air Content in Hydraulic Fluid; 2) Method for Measuring Collimator-Pointing Sensitivity to Temperature Changes; 3) High-Temperature Thermometer Using Cr-Doped GdAlO3 Broadband Luminescence; 4)Metrology Arrangement for Measuring the Positions of Mirrors of a Submillimeter Telescope; 5) On-Wafer S-Parameter Measurements in the 325-508-GHz Band; 6) Reconfigurable Microwave Phase Delay Element for Frequency Reference and Phase-Shifter Applications; 7) High-Speed Isolation Board for Flight Hardware Testing; 8) High-Throughput, Adaptive FFT Architecture for FPGA-Based Spaceborne Data Processors; 9) 3D Orbit Visualization for Earth-Observing Missions; 10) MaROS: Web Visualization of Mars Orbiting and Landed Assets; 11) RAPID: Collaborative Commanding and Monitoring of Lunar Assets; 12) Image Segmentation, Registration, Compression, and Matching; 13) Image Calibration; 14) Rapid ISS Power Availability Simulator; 15) A Method of Strengthening Composite/Metal Joints; 16) Pre-Finishing of SiC for Optical Applications; 17) Optimization of Indium Bump Morphology for Improved Flip Chip Devices; 18) Measuring Moisture Levels in Graphite Epoxy Composite Sandwich Structures; 19) Marshall Convergent Spray Formulation Improvement for High Temperatures; 20) Real-Time Deposition Monitor for Ultrathin Conductive Films; 21) Optimized Li-Ion Electrolytes Containing Triphenyl Phosphate as a Flame-Retardant Additive; 22) Radiation-Resistant Hybrid Lotus Effect for Achieving Photoelectrocatalytic Self-Cleaning Anticontamination Coatings; 23) Improved, Low-Stress Economical Submerged Pipeline; 24) Optical Fiber Array Assemblies for Space Flight on the Lunar Reconnaissance Orbiter; 25) Local Leak Detection and Health Monitoring of Pressurized Tanks; 26) Dielectric Covered Planar Antennas at Submillimeter Wavelengths for Terahertz Imaging; 27) Automated Cryocooler Monitor and Control System; 28) Broadband Achromatic Phase Shifter for a Nulling Interferometer; 29) Super Dwarf Wheat for Growth in Confined Spaces; 30) Fine Guidance Sensing for Coronagraphic Observatories; 31) Single-Antenna Temperature- and Humidity-Sounding Microwave Receiver; 32) Multi-Wavelength, Multi-Beam, and Polarization-Sensitive Laser Transmitter for Surface Mapping; 33) Optical Communications Link to Airborne Transceiver; 34) Ascent Heating Thermal Analysis on Spacecraft Adaptor Fairings; 35) Entanglement in Self-Supervised Dynamics; 36) Prioritized LT Codes; 37) Fast Image Texture Classification Using Decision Trees; 38) Constraint Embedding Technique for Multibody System Dynamics; 39) Improved Systematic Pointing Error Model for the DSN Antennas; 40) Observability and Estimation of Distributed Space Systems via Local Information-Exchange Networks; 41) More-Accurate Model of Flows in Rocket Injectors; 42) In-Orbit Instrument-Pointing Calibration Using the Moon as a Target; 43) Reliability of Ceramic Column Grid Array Interconnect Packages Under Extreme Temperatures; 44) Six Degrees-of-Freedom Ascent Control for Small-Body Touch and Go; and 45) Optical-Path-Difference Linear Mechanism for the Panchromatic Fourier Transform Spectrometer.

Source record↗

Multiple-copy state discrimination: Thinking globally, acting locally

We theoretically investigate schemes to discriminate between two nonorthogonal quantum states given multiple copies. We consider a number of state discrimination schemes as applied to nonorthogonal, mixed states of a qubit. In particular, we examine the difference that local and global optimization of local measurements makes to the probability of obtaining an erroneous result, in the regime of finite numbers of copies N, and in the asymptotic limit as N{yields}{infinity}. Five schemes are considered: optimal collective measurements over all copies, locally optimal local measurements in a fixed single-qubit measurement basis, globally optimal fixed local measurements, locally optimal adaptive local measurements, and globally optimal adaptive local measurements. Here an adaptive measurement is one in which the measurement basis can depend on prior measurement results. For each of these measurement schemes we determine the probability of error (for finite N) and the scaling of this error in the asymptotic limit. In the asymptotic limit, it is known analytically (and we verify numerically) that adaptive schemes have no advantage over the optimal fixed local scheme. Here we show moreover that, in this limit, the most naive scheme (locally optimal fixed local measurements) is as good as any noncollective scheme except for states with less than 2% mixture. For finite N, however, the most sophisticated local scheme (globally optimal adaptive local measurements) is better than any other noncollective scheme for any degree of mixture.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determining Magnetic Field Directions and Omni-directional Fluxes of Particles from STPSat-6 ZPS Plasma Measurements

This report summarizes our recent data derivation efforts on STPSat-6 ZPS plasma measurements, presenting final outcomes. We begin by outlining the methodology developed to determine local magnetic field directions from measured directional intensities of ~20 keV ions, leveraging symmetry in particles’ pitch-angle distributions, and the determined field directions over a storm period are shown with errors analyzed through comparison with NOAA GOES measurements. Next, we further assess the validity of the method and quantify its overall high performance while acknowledging certain caveats. Finally, given local magnetic field directions and ZPS data, we explain how omni-directional fluxes of particles can be derived from ZPS measurements with limited directional coverage, and estimate the related errors under several theoretical scenarios. The methods developed in this study can be applied for processing and augmenting ZPS data for the next, and the insights gained here can also inform instrument design in the future.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Estimating Sea Surface Salinity and Wind Using Combined Passive and Active L-Band Microwave Observations

Several L-band microwave radiometer and radar missions have been, or will be, operating in space for land and ocean observations. These include the NASA Aquarius mission and the Soil Moisture Active Passive (SMAP) mission, both of which use combined passive/ active L-band instruments. Aquarius s passive/active L-band microwave sensor has been designed to map the salinity field at the surface of the ocean from space. SMAP s primary objectives are for soil moisture and freeze/thaw detection, but it will operate continuously over the ocean, and hence will have significant potential for ocean surface research. In this innovation, an algorithm has been developed to retrieve simultaneously ocean surface salinity and wind from combined passive/active L-band microwave observations of sea surfaces. The algorithm takes advantage of the differing response of brightness temperatures and radar backscatter to salinity, wind speed, and direction, thus minimizing the least squares error (LSE) measure, which signifies the difference between measurements and model functions of brightness temperatures and radar backscatter. The algorithm uses the conjugate gradient method to search for the local minima of the LSE. Three LSE measures with different measurement combinations have been tested. The first LSE measure uses passive microwave data only with retrieval errors reaching 1 to 2 psu (practical salinity units) for salinity, and 1 to 2 m/s for wind speed. The second LSE measure uses both passive and active microwave data for vertical and horizontal polarizations. The addition of active microwave data significantly improves the retrieval accuracy by about a factor of five. To mitigate the impact of Faraday rotation on satellite observations, the third LSE measure uses measurement combinations invariant under the Faraday rotation. For Aquarius, the expected RMS SSS (sea surface salinity) error will be less than about 0.2 psu for low winds, and increases to 0.3 psu at 25 m/s wind speed for warm waters (25 C). To achieve the required 0.2 psu accuracy, the impact of sea surface roughness (e.g. wind-generated ripples) on the observed brightness temperature has to be corrected to better than one tenth of a degree Kelvin. With this algorithm, the accuracy of retrieved wind speed will be high, varying from a few tenths to 0.6 m/s. The expected direction accuracy is also excellent (less than 10 ) for mid to high winds, but degrades for lower speeds (less than 7 m/s).

Yueh, Simon H.↗

Cosmological parameters degeneracies and non-Gaussian halo bias

We study the impact of the cosmological parameters uncertainties on the measurements of primordial non-Gaussianity through the large-scale non-Gaussian halo bias effect. While this is not expected to be an issue for the standard ΛCDM model, it may not be the case for more general models that modify the large-scale shape of the power spectrum. We consider the so-called local non-Gaussianity model, parametrized by the f{sub NL} non-Gaussianity parameter which is zero for a Gaussian case, and make forecasts on f{sub NL} from planned surveys, alone and combined with a Planck CMB prior. In particular, we consider EUCLID- and LSST-like surveys and forecast the correlations among f{sub NL} and the running of the spectral index α{sub s}, the dark energy equation of state w, the effective sound speed of dark energy perturbations c{sup 2}{sub s}, the total mass of massive neutrinos M{sub ν} = Σm{sub ν}, and the number of extra relativistic degrees of freedom N{sub ν}{sup rel}. Neglecting CMB information on f{sub NL} and scales k > 0.03h/Mpc, we find that, if N{sub ν}{sup rel} is assumed to be known, the uncertainty on cosmological parameters increases the error on f{sub NL} by 10 to 30% depending on the survey. Thus the f{sub NL} constraint is remarkable robust to cosmological model uncertainties. On the other hand, if N{sub ν}{sup rel} is simultaneously constrained from the data, the f{sub NL} error increases by ∼ 80%. Finally, future surveys which provide a large sample of galaxies or galaxy clusters over a volume comparable to the Hubble volume can measure primordial non-Gaussianity of the local form with a marginalized 1-σ error of the order Δf{sub NL} ∼ 2−5, after combination with CMB priors for the remaining cosmological parameters. These results are competitive with CMB bispectrum constraints achievable with an ideal CMB experiment.

79 ASTRONOMY AND ASTROPHYSICS↗

Stochastic tensor contraction for quantum chemistry

Many computational methods in ab initio quantum chemistry are formulated in terms of high-order tensor contractions, whose cost determines the size of system that can be studied. We introduce stochastic tensor contraction to perform such operations with greatly reduced cost, and present its application to the gold-standard quantum chemistry method, coupled cluster theory with up to perturbative triples. For total energy errors more stringent than chemical accuracy, we reduce the computational scaling to that of mean-field theory, while starting to approach the mean-field absolute cost, thereby challenging the existing cost-to-accuracy landscape. Benchmarks against state-of-the-art local correlation approximations further show that we achieve an order-of-magnitude improvement in both total computation time and error, with significantly reduced sensitivity to system dimensionality and electron delocalization. We conclude that stochastic tensor contraction is a powerful computational primitive to accelerate a wide range of quantum chemistry.

Chemical Physics (physics.chem-ph)↗

Region Spherical Harmonic Magnetic Modeling from Near-Surface and Satellite-Altitude Anomlaies

The compiled near-surface data and satellite crustal magnetic measured data are modeled with a regionally concentrated spherical harmonic presentation technique over Australia and Antarctica. Global crustal magnetic anomaly studies have used a spherical harmonic analysis to represent the Earth's magnetic crustal field. This global approach, however is best applied where the data are uniformly distributed over the entire Earth. Satellite observations generally meet this requirement, but unequally distributed data cannot be easily adapted in global modeling. Even for the satellite observations, due to the errors spread over the globe, data smoothing is inevitable in the global spherical harmonic presentations. In addition, global high-resolution modeling requires a great number of global spherical harmonic coefficients for the regional presentation of crustal magnetic anomalies, whereas a lesser number of localized spherical coefficients will satisfy. We compared methods in both global and regional approaches and for a case where the errors were propagated outside the region of interest. For observations from the upcoming Swarm constellation, the regional modeling will allow the production a lesser number of spherical coefficients that are relevant to the region of interest

Modeling↗

Electronic structure calculations with the Tran-Blaha modified Becke-Johnson Density Functional

We report a series of calculations testing the predictions of the Tran-Blaha functional for the electronic structure and magnetic properties of condensed systems. We find a general improvement in the properties of semiconducting and insulating systems, relative to calculations with standard generalized gradient approximations, although this is not always by the same mechanism as other approaches such as the quasiparticle GW method. In ZnO the valence bands are narrowed and the band gap is increased to a value in much better agreement with experiment. The Zn d states do not move to higher binding energy as they do in local-density approximation+U calculations. The functional is effective for systems with hydride anions, where correcting self-interaction errors in the 1s state is important. Similarly, it correctly opens semiconducting gaps in the alkaline-earth hexaborides. It correctly stabilizes an antiferromagnetic insulating ground state for the undoped cuprate parent CaCuO{sub 2}, but seriously degrades the agreement with experiment for ferromagnetic Gd relative to the standard local-spin-density approximation and generalized gradient approximations. This is due to positioning of the minority-spin 4f states at too low an energy. Conversely, the position of the La 4f conduction bands of La{sub 2}O{sub 3} is in reasonable accord with experiment as it is with standard functionals. The functional narrows the Fe d bands of the parent compound LaFeAsO of the iron high-temperature superconductors while maintaining the high Fe spectral weight near the Fermi energy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effective Local Geometry Descriptor for 29Si NMR Q4 Anisotropy

The nuclear shielding anisotropy, ζ, is a useful nuclear magnetic resonance (NMR) shielding tensor parameter in describing the extent of electron cloud distortion about an atom. Despite the advantages afforded by NMR in structural characterization, the relationship between ζ and local structure of an atom in high-symmetry environments, such as Si-Q 4 sites, is poorly understood. Here, we use a data-driven approach combining random forest feature ranking and the Sure Independence Screening and Sparsifying Operator (SISSO) approach to derive a simple and accurate geometric descriptor for ζ with a root-mean-squared prediction error of 6.77 ppm and an R 2 of 0.761. We then apply this descriptor to describe the local geometric distortion of zeolites Sigma-2 and silica-ZSM-5 whose chemical shift anisotropy tensor has been reported. We envision that this geometric descriptor will allow for structural description and refinement in previously difficult-to-describe materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of CT on Rails With Electronic Portal Imaging for Positioning of Prostate Cancer Patients With Implanted Fiducial Markers

Purpose: The objective of this investigation was to measure the agreement between in-room computed tomography (CT) on rails and electronic portal image (EPI) radiography. Methods and Materials: Agreement between the location of the center of gravity (COG) of fiducial markers (FMs) on CT and EPI images was determined in phantom studies and a patient cohort. A secondary analysis between the center of volume (COV) of the prostate on CT and the COG of FMs on CT and EPI was performed. Agreement was defined as the 95% probability of a difference of {<=}3.0 mm between images. Systematic and random errors from CT and EPI are reported. Results: From 8 patients, 254 CT and EPI pairs were analyzed. FMs were localized to within 3 mm on CT and EPI images 96.9% of the time in the left-right (LR) plane, 85.8% superior-inferior (SI), and 89% anterior-posterior (AP). The differences between the COV on CT and the COG on EPI were not within 3 mm in any plane: 87.8% (LR), 64.2% (SI), and 70.9% (AP). The systematic error varied from 1.2 to 2.9 mm (SI) and 1.8-2.9 mm (AP) between the COG on EPI and COV on CT. Conclusions: Considerable differences between in-room CT and EPI exist. The phantom measurements showed slice thickness affected the accuracy of localization in the SI plane, and couch sag that occurs at the CT on rails gantry could not be totally corrected for in the AP plane. Other confounding factors are the action of rotating the couch and associated time lag between image acquisitions (prostate motion), EPI image quality, and outlining uncertainties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Global Aerodynamic Modeling Using Automated Local Model Networks in Real Time

A novel method is presented for automated real-time global aerodynamic modeling using local model networks, known as Smoothed Partitioning with Localized Trees in Real Time (SPLITR), as part of NASA’s Learn-to-Fly technology development initiative. The global nonlinear aerodynamics are partitioned into several local regions known as cells, with the dimension, location, and timing of each partition automatically selected based on a residual characterization procedure, under the constraints of real-time operation. Regression trees represent the successive partitioning of the global flight envelope and describe the evolution of the cell structure. Recursive equation-error least-squares parameter estimation in the time domain is used to estimate a model that represents the local aerodynamics in each region, so that it can be updated independently with non-contiguous data in the range of each cell over time. A weighted superposition of these piecewise local models across the flight envelope forms a global nonlinear model that also accurately captures the local aerodynamics. The SPLITR approach is demonstrated using both simulation and flight data, and the results are analyzed in terms of model predictive capabilities as well as interpretability. The results show that SPLITR can be used to automatically partition complex nonlinear aerodynamic behavior, produce an accurate model, and provide valuable physical insight into the local and global aerodynamics.

Weinstein, Rose↗

Effect of Immobilization and Performance Status on Intrafraction Motion for Stereotactic Lung Radiotherapy: Analysis of 133 Patients

Purpose: To assess intrafractional geometric accuracy of lung stereotactic body radiation therapy (SBRT) patients treated with volumetric image guidance. Methods and Materials: Treatment setup accuracy was analyzed in 133 SBRT patients treated via research ethics board-approved protocols. For each fraction, a localization cone-beam computed tomography (CBCT) scan was acquired for soft-tissue registration to the internal target volume, followed by a couch adjustment for positional discrepancies greater than 3 mm, verified with a second CBCT scan. CBCT scans were also performed at intrafraction and end fraction. Patient positioning data from 2047 CBCT scans were recorded to determine systematic ({Sigma}) and random ({sigma}) uncertainties, as well as planning target volume margins. Data were further stratified and analyzed by immobilization method (evacuated cushion [n = 75], evacuated cushion plus abdominal compression [n = 33], or chest board [n = 25]) and by patients' Eastern Cooperative Oncology Group performance status (PS): 0 (n = 31), 1 (n = 70), or 2 (n = 32). Results: Using CBCT internal target volume was matched within {+-}3 mm in 16% of all fractions at localization, 89% at verification, 72% during treatment, and 69% after treatment. Planning target volume margins required to encompass residual setup errors after couch corrections (verification CBCT scans) were 4 mm, and they increased to 5 mm with target intrafraction motion (post-treatment CBCT scans). Small differences (<1 mm) in the cranial-caudal direction of target position were observed between the immobilization cohorts in the localization, verification, intrafraction, and post-treatment CBCT scans (p < 0.01). Positional drift varied according to patient PS, with the PS 1 and 2 cohorts drifting out of position by mid treatment more than the PS 0 cohort in the cranial-caudal direction (p = 0.04). Conclusions: Image guidance ensures high geometric accuracy for lung SBRT irrespective of immobilization method or PS. A 5-mm setup margin suffices to address intrafraction motion. This setup margin may be further reduced by strategies such as frequent image guidance or volumetric arc therapy to correct or limit intrafraction motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Uranian aurora and its relationship to the magnetosphere

About 32 h of Voyager Ultraviolet Spectrometer (UVS) observations of Uranus H2 band airglow emission (875 less than or equal to lambda less than or equal to 1115 A) have been analyzed using the singular value decomposition (SVD) approach to inversion, producing an intensity map showing aurora at both magnetic poles. An H Lyman alpha aurora may also be present but is difficult to separate from scattered solar and local interstellar medium components. SVD analysis of variance shows that the intensity estimate is significantly larger than the error estimate over both Uranographic poles and part of the equatorial region, fortuitously including both magnetic polar regions. The Goddard Space Flight Center Q(sub 3) magnetic field model correctly predicts that the aurora should be larger in area and emit more power at the weaker N magnetic pole than at the stronger S magnetic pole. However, the auroral emissions are quite localized in magnetic longitude and so do not form complete auroral ovals. The brightest auroral emission at each magnetic pole is confined to a range of approximately 90 deg of magnetic longitude centered on the magnetotail direction, at moderate magnetic L parameter (5 less than or equal to L less than or equal to 10), but some emission at each pole is distributed over a range of more than 180 deg of longitude. The magnetic longitudes of the aurora are completely inconsistent with the 'windshield wiper' effect for either ions or electrons, indicating that some other effect, such as rapid depletion of the population of precipitating particles of highly localized strong pitch-angle diffusion, may be acting to localize emission. The low apparent L of the precipitating particles indicates that their energies may be less than or equal to 10 keV. Hence magnetospheric convection is likely to be important, and thus particles exciting the aurora may not remain on constant L shells. The precipitating particles may be a relatively low-energy population at high L that is heated to aurora-exciting energy by adiabatic compression during convection to low L. We estimate that the total auroral power output at H Lyman alpha and shorter wavelengths is about 3 x 10(exp 9) to 7 x 10(exp 9) W, requiring about 10 times that much power for excitation.

Herbert, Floyd↗

A Particle-in-Cell Method for Plasmas with a Generalized Momentum Formulation, Part II: Enforcing the Lorenz Gauge Condition

In a previous paper Christlieb et al. (A particle-in-cell method for plasmas with a generalized momentum formulation, part I: Model formulation, 2024), we developed a new particle-in-cell (PIC) method for the relativistic Vlasov–Maxwell system in which the electromagnetic fields and the equations of motion for the particles were cast in terms of scalar and vector potentials through a Hamiltonian formulation. This new method evolved the potentials under the Lorenz gauge using integral equation methods. New methods to construct spatial derivatives of the potentials that converge at the same rates as the fields were also presented. The new particle method was compared against standard explicit discretizations, including the well-known FDTD-PIC method, for a range of applications involving sheaths and particle beams. Here, this paper extends this new class of methods by focusing on the enforcement the Lorenz gauge condition in both exact and approximate forms using co-located meshes. A time-consistency property of the proposed field solver for the vector potential form of Maxwell’s equations is established, which is shown to preserve the equivalence between the semi-discrete Lorenz gauge condition and the analogous semi-discrete continuity equation. Using this property, we present three methods to enforce a semi-discrete gauge condition. The first method introduces an update for the continuity equation that is consistent with the discretization of the Lorenz gauge condition. Both the finite difference and spectral implementations satisfy this discrete gauge condition to machine precision. The second approach we propose enforces a semi-discrete continuity equation using the boundary integral solution to the field equations. The potential benefit of this approach is that it eliminates spatial derivatives that appear on the particle data, namely the current density, which is often calculated by linear combinations of low-order spline basis functions. This method is ideally suited to boundary integral equation methods that invert multi-dimensional operators without dimensional splitting techniques and will be the subject of future work. The third approach introduces a gauge correcting method that makes direct use of the gauge condition to modify the scalar potential and uses local maps for both the charge and current densities. This results in a gauge error, as the maps do not enforce the continuity equation. The vector potential coming from the current density is taken to be exact, and using the Lorenz gauge, we compute a correction to the scalar potential that makes the two potentials satisfy the gauge condition. This method also enforces the gauge condition to machine precision. We demonstrate two of the proposed methods in the context of periodic domains. Problems defined on bounded domains, including those with complex geometric features remain an ongoing effort. However, this work shows that it is possible to design computationally efficient methods that can effectively enforce the Lorenz gauge condition in a non-staggered PIC formulation.

97 MATHEMATICS AND COMPUTING↗

How Accurate Is Density Functional Theory at Predicting Dipole Moments? An Assessment Using a New Database of 200 Benchmark Values

We present that dipole moments are a simple, global measure of the accuracy of the electron density of a polar molecule. Dipole moments also affect the interactions of a molecule with other molecules as well as electric fields. To directly assess the accuracy of modern density functionals for calculating dipole moments, we have developed a database of 200 benchmark dipole moments, using coupled cluster theory through triple excitations, extrapolated to the complete basis set limit. This new database is used to assess the performance of 88 popular or recently developed density functionals. The results suggest that double hybrid functionals perform the best, yielding dipole moments within about 3.6-4.5% regularized RMS error versus the reference values - which is not very different from the 4% regularized RMS error produced by coupled cluster singles and doubles. Many hybrid functionals also perform quite well, generating regularized RMS errors in the 5-6% range. Lastly, some functionals, however, exhibit large outliers, and local functionals in general perform less well than hybrids or double hybrids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Commissioning Procedures for Mechanical Precision and Accuracy in a Dedicated LINAC

Mechanical precision measurements are fundamental procedures for the commissioning of a dedicated LINAC. At our Radioneurosurgery Unit, these procedures can be suitable as quality assurance routines that allow the verification of the equipment geometrical accuracy and precision. In this work mechanical tests were performed for gantry and table rotation, obtaining mean associated uncertainties of 0.3 mm and 0.71 mm, respectively. Using an anthropomorphic phantom and a series of localized surface markers, isocenter accuracy showed to be smaller than 0.86 mm for radiosurgery procedures and 0.95 mm for fractionated treatments with mask. All uncertainties were below tolerances. The highest contribution to mechanical variations is due to table rotation, so it is important to correct variations using a localization frame with printed overlays. Mechanical precision knowledge would allow to consider the statistical errors in the treatment planning volume margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

RESIDUAL HUBBLE-BUBBLE EFFECTS ON SUPERNOVA COSMOLOGY

Even in a universe that is homogeneous on large scales, local density fluctuations can imprint a systematic signature on the cosmological inferences we make from distant sources. One example is the effect of a local underdensity on supernova cosmology. Also known as a Hubble-bubble, it has been suggested that a large enough underdensity could account for the supernova magnitude-redshift relation without the need for dark energy or acceleration. Although the size and depth of the underdensity required for such an extreme result is extremely unlikely to be a random fluctuation in an on-average homogeneous universe, even a small underdensity can leave residual effects on our cosmological inferences. It is these small underdensities that we consider here. In this paper, we show that there remain systematic shifts in our cosmological parameter measurements, even after excluding local supernovae that are likely to be within any small Hubble-bubble. We study theoretically the low-redshift cutoff typically imposed by supernova cosmology analyses and show that a low-redshift cut of z {sub 0} {approx} 0.02 may be too low based on the observed inhomogeneity in our local universe. Neglecting to impose any low-redshift cutoff can have a significant effect on the cosmological parameters derived from supernova data. A slight local underdensity, just 30% underdense with scale 70 h {sup -1} Mpc, causes an error in the inferred cosmological constant density {Omega}{sub {Lambda}} of {approx}4%. Imposing a low-redshift cutoff reduces this systematic error but does not remove it entirely. A residual systematic shift of 0.99% remains in the inferred value {Omega}{sub {Lambda}} even when neglecting all data within the currently preferred low-redshift cutoff of 0.02. Given current measurement uncertainties, this shift is not negligible and will need to be accounted for when future measurements yield higher precision.

79 ASTRONOMY AND ASTROPHYSICS↗