Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy systems integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Model Predictive Control for a Grid-interactive Efficient Thermal Storage-integrated Heat Pump System

Building heating and cooling systems can be used to overcome the mismatch between the intermittent supply of renewable power and the fluctuating demand for electricity. A novel underground thermal energy storage integrated with a dual-source heat pump has been proposed to mitigate the mismatch while meeting the thermal demand of buildings efficiently. Conventional thermostat control with heuristic rules cannot provide intelligent decisions to maximize the thermal efficiency and flexibility of the proposed system. Advanced control strategies like model predictive control (MPC) have provided a new paradigm for grid-interactive efficient building operation with the advancement of computation and sensing. This study developed an MPC for the proposed system to provide grid service for Demand Side Management and minimize the operating cost of building owners. A control-oriented dynamic model of the proposed system has been developed. Given an objective function and proper constraints, an optimization problem is formulated to determine the optimal control strategy of the system. Dynamic Programming is adopted to solve the optimization problem. A rule-based control (RBC) is also developed to achieve similar goals. Short-term simulations are conducted to compare the system performance resulting from the two controls. The simulation results indicate that the MPC performs more intelligently than the RBC in charging thermal energy storage and selecting heat pump sources by taking advantage of the predicted cooling demands of the building and the performance of the integrated system. As a result, the MPC could save energy and reduce operating costs compared with the RBC. A case study shows that, for a 3-day operation, the MPC saves 36.9% energy and reduces 38.5% operating cost compared with the RBC.

Shi, Liang↗

Scalable Risk Assessment of Rare Events in Power Systems With Uncertain Wind Generation and Loads

Risk assessment of rare events has become increasingly important in power system planning and operation with the increasing integration of renewable energy and the presence of system uncertainties. However, quantifying the risk posed by rare events via the traditional method, i.e., Monte Carlo sampling (MCS), incurs substantial computational expense stemming from the vast ensemble of power flow simulations. To accelerate the assessment, this paper proposes a Deep Neural Network (DNN)-kernelized vector-valued Gaussian Process (VVGP) approach with excellent computational efficiency while maintaining high accuracy. Consequently, serving as a surrogate model for the power flow solver, the DNN-kernelized VVGP enables significantly faster but accurate risk assessment compared to the power flow solver. The developed surrogate model evaluates low-order N - k events that contain more than 90% instances by adeptly capturing the topological features while the high-order N - k events are assessed via a power flow solver, thereby striking a balance between computational efficiency and uncertainty quantification accuracy. Moreover, the model incorporates a Support Vector Machine (SVM) classifier to resample concerning low-probability tail events to counteract the biases potentially introduced during the DNN-kernelized VVGP evaluations. Simulations conducted on the modified IEEE 24-bus, 118-bus, and European 1354-bus systems demonstrate that the proposed method maintains the accuracy benchmark set by MCS while significantly reducing computational demands in large-scale power systems as compared to other state-of-the-art methods.

17 WIND ENERGY↗

Insights for Canadian electricity generation planning from an integrated assessment model: Should we be more cautious about hydropower cost overruns?

Hydropower accounts for approximately 60% of electricity generation in Canada, with growth expected in the coming decades as part of renewable energy transitions; however, frequent cost overruns threaten the viability of this growth. Here, using the integrated assessment model GCAM, we develop an endogenous representation of hydropower for Canada that accounts for market dynamics, thus permitting analysis of hydropower competition with other electricity generation technologies, both with and without cost overruns. Results show that modelling hydropower resources endogenously increases Canadian hydropower deployment relative to an assumption of fixed hydropower production, from 417 to 495 TWh annually by 2050. In scenarios that apply cost overruns at historical levels, hydropower loses market share to more easily scalable technologies like wind power. When including high cost overrun assumptions, the model determines that hydropower falls from about 73% to 65% of Canadian electricity generation by 2050, while wind power increases from about 8% to 11%. Countries may be better able to achieve electrification and renewable energy targets at lower cost by avoiding large-scale, overrun-prone hydropower and nuclear generation projects. Model results support that cost overruns are important considerations for policy decisions related to electricity sector development in Canada and elsewhere.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Towards a Techno-Economic Analysis of PCM Integrated Hybrid HVAC Systems

Thermal end uses dominate building energy consumption and are a major driver of peak demand. As heating is electrified, peak electrical power required will surge, prompting a need for innovative HVAC system designs and controls.These designs must incorporate novel technologies at the component level and new integration techniques at the system level. One such possibility involves the addition of thermal energy storage (TES) in heating and cooling equipment using a phase change material (PCM) heat exchanger. Here, thermal energy storage via phase change can be used to shift the HVAC system loads to times of lower electricity cost, reduced carbon intensity, and greater energy efficiency. Most of the current utilization of PCM in buildings involves passive components. By actively controlling when heat is stored and released from PCM, we can optimize the building HVAC system to cost-effectively meet consumer needs with the flexibility to draw on renewable energy resources when they are abundant and available. While this combination of technologies is promising in theory, simulation-based evaluation of a prototype can be difficult due to the modeling requirements at the component level and the large number of possible configurations and operating modes at the system level. To conduct this evaluation, we use the Modelica language for modeling and simulation because it enables users to represent the important physics of the problem, interchange and rearrange components in an efficient manner, and implement a range of control configurations. In this work, we considered three case studies: a portable building, a large commercial retail store, and a multifamily residential apartment unit. Each of these employs a different system design, ranging from a single package vertical unit incorporating PCM to a central plant with independent heat pump, evaporative cooling, and thermal energy storage components. This paper describes the technologies in question, presents modeling at the component and system levels, and demonstrates building energy and demand charge cost savings with local time-of-use tariffs in a hot-dry climate.

Helmns, Dre↗

Mobility Data and Models Informing Smart Cities

This presentation explores the interactions of Emerging Technology, Changing Urban Environments, and Urban Travel Behavior on Mobility and Energy Impacts. Key findings include quantifying impacts of emerging mobility, access and infrastructure associated with new mobility choices and services in urban areas. The results demonstrate new data collection methods and capabilities to understand and identify key levers to improve energy productivity of future mobility systems and of quickly evolving MaaS and COVID-19 contexts to monitor rapidly shifting urban mobility patterns. Under development are mode choice models for new modes versus traditional modes. Initial estimates are developed on the potential of workforce mobility strategies in shaping future energy-efficient mobility system impacts. For mode replacement and workforce mobility, this presentation offers observability into the changes in number of transactions per mode, after ride-hailing/TNC/MaaS introduction and in origins of workforce to enable user need-driven reimagining of efficient mobility systems: Seattle (SEA-TAC) airport: for every 100 new TNC transactions for ground transportation, ~27% replaced transit, 35% replaced parking, 17% replaced car rentals, and 21% replaced taxis. Similarly, at Denver International (DEN), ride-hailing transactions replaced transit, parking, car rental and taxis at a rate of 34.7%, 39.0%, 16.6%, and 9.7%, respectively. A workforce mobility tool, analysis/visualization techniques, and capabilities to understand and identify key job commute needs, new choices in access to job opportunities, and affordability aspects as levers to improve energy productivity of future integrated urban mobility systems.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Defining a Use Case for the ADMS Test Bed: Fault Location, Isolation, and Service Restoration with Distributed Energy Resources

Advanced distribution management systems (ADMS) integrate multiple enterprise-level functions into a single platform and offer advanced applications such as fault location, isolation, and service restoration (FLISR), to utilities to meet their operational needs for a modernized grid. These applications need to operate reliably even as distributed energy resource (DER) penetration increases on distribution systems. The ADMS test bed at the National Renewable Energy Laboratory offers utilities and vendors the opportunity to evaluate the performance of such advanced applications on distribution feeders of the future and to understand their potential benefits for a specific utility. This is done through defining use cases that address specific questions. This paper presents the definition of a use case on the performance of a commercially-available FLISR application on a feeder of an electric cooperative with DERs. After experiments are completed, results from this use case will be disseminated to the electric utility and research community to improve understanding of the challenges and benefits that DERs present to ADMS applications and the operation of a modernized grid.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Marine energy supported multi-energy system planning and operation optimization for sustainable coastal community

The growing need for sustainable energy solutions in coastal areas necessitates the development of integrated systems that leverage abundant marine resources. In this study, a standalone Marine Energy Supported Multi-Energy System (MRE-MES) is designed for sustainable coastal community development, utilizing renewable marine resources, including offshore wind, wave, and solar energy, to address the energy needs of electricity, heat, freshwater, and hydrogen. The proposed MRE-MES incorporates a co-optimization model that simultaneously balances capacity planning and operational efficiency to minimize costs and environmental impacts. The system is tested under different renewable energy penetration levels and demand uncertainties, using a two-stage stochastic programming to account for variability in renewable resources and consumption needs. The experimental results indicate that in the optimal system capacity configuration, the percentage of total renewable energy generation is around 80 %, with or without capacity limitation constraints on PV, water tank, and hydrogen storage. Compared to the worst-case scenario in Monte Carlo experiments, two-stage stochastic optimization results in a more robust decision that effectively mitigates the risks posed by future uncertain demand conditions. In conclusion, the findings highlight the viability of marine energy for providing a resilient, comprehensive energy solution to coastal communities.

Capacity planning↗

Optimal, Reliable Building-Integrated Energy Storage (Cooperative Research and Development Final Report)

The team will advance the commercial readiness of behind-the-meter (BTM) energy storage (ES) systems by employing health-conscious controls that guarantee lifetime and optimize the ES system's value stream when integrated with onsite renewable energy generation. Specifically, the team will develop ES controls that increase the net present value (NPV) of photovoltaics (PV) by 50% in markets where net-metering policies are being replaced by variable electricity pricing structures. The team will also reduce the risk of achieving a 10-year ES warranty lifetime by at least one order of magnitude. The successful two-year project will develop the controls and system enabling Eaton to commercialize the technology by 2021. The developments achieved through this project may enable wide scale adoption of stationary energy storage benefitting the public.

25 ENERGY STORAGE↗

Assessment of the polygeneration approach in wastewater treatment plants for enhanced energy efficiency and green hydrogen/ammonia production

Wastewater treatment plants (WWTPs) offer opportunities to optimize resource utilization and enhance energy efficiency. Here, this study provides a comprehensive analysis of using the polygeneration approach in WWTPs to reduce grid energy dependence, optimize energy distribution, and utilize surplus energy for hydrogen (H 2 ) and ammonia (NH 3 ) production. Several models were employed, including photovoltaic (PV) cells, parabolic trough collectors (PTCs), steam methane reforming, and polymer electrolyte membranes, to assess the feasibility of this approach. Three scenarios were evaluated and compared: Scenario 1 (Baseline) represents the current situation, Scenario 2 maximizes the Net Present Value (NPV), and Scenario 3 minimizes NH 3 production costs. Real data from As-Samra WWTP in Jordan was used to accurately assess the feasibility of each scenario. The results show that Scenario 2 offers the highest profitability and efficiency, with a NPV of 87.48 million USD and an annual NH 3 production of 15,417 tons, reducing both grid dependency and biogas fuel consumption. Both Scenarios 2 and 3 demonstrate the ability to meet thermal demands efficiently while generating significant revenue from NH 3 production. Scenario 3, in particular, achieves competitive H 2 and NH 3 production costs. Environmentally, Scenario 2 significantly reduces annual greenhouse gas emissions by 12.66 kilotons of CO 2eq , with near-zero carbon intensity for thermal energy due to solar reliance. In conclusion, the polygeneration approach offers a promising pathway for WWTPs to achieve greater sustainability, economic gains, and reduced environmental impact, providing valuable insights for decision-makers.

42 ENGINEERING↗

Low-voltage syngas synthesis via BPM electrolysis of CO 2 capture and aldehyde solution

A bipolar membrane electrolyzer coupling bicarbonate electrolysis with formaldehyde oxidation directly produces syngas (H 2 : CO = 1) at 1.7 V and 200 mA cm −2 with 200% combined Faradaic efficiency. We demonstrate an electrochemical syngas production platform that couples bicarbonate electrolysis with formaldehyde oxidation in a bipolar membrane electrode assembly. This strategy doubles syngas (CO + H 2 ) throughput compared to conventional CO 2 electrolysis by generating CO at the cathode and H 2 at the anode. The system achieves a full-cell voltage of 1.7 V while operating at an industrially relevant current density of 200 mA cm −2 . The system maintained a combined Faradaic efficiency of 200% over 8 hours. The process produces syngas with a 1 : 1 H 2 : CO ratio, aligning with downstream requirements for Fischer–Tropsch synthesis. We further investigated how Cu anode active sites and electrolyte composition affect formaldehyde oxidation activity. Our integrated electrolytic system reduces levelized energy by 45–61% relative to conventional electrochemical syngas production platforms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On-Chip Batteries as Distributed Energy Sources in Heterogeneous 2.5D/3D Integrated Circuits

Energy efficiency in digital systems faces challenges due to the constraints imposed by small-scale transistors. Moreover, the growing demand for portable consumer electronics necessitates the use of compact energy sources. To address these challenges, heterogeneous 3D IC technology has emerged as a promising solution for the former. Regarding the latter, we propose the concept of distributed batteries within a heterogeneous 3D IC. This approach involves utilizing multiple smaller batteries with different specifications among different modules of 3D ICs. This approach optimizes performance and overcomes limitations associated with both 3D ICs and conventional power delivery methods. Distributed batteries play a vital role in effectively managing the heat generated by energy sources and modules within a 3D IC. Furthermore, they contribute to achieving a uniform distribution of heat throughout the entire structure, which ultimately ensures the optimal performance of the batteries and modules. The simulation results indicate a 40 percent enhancement in achieving a more even distribution of generated heat. Additionally, the proposed distributed battery techniques improve power delivery, enhance reliability, and enable optimized voltage regulation while improving efficiency. In addition to the primary benefits, alternative configurations of the proposed approach can offer extra energy storage capacity and act as efficient electromagnetic shields, resulting in an impressive reduction of external electromagnetic noises by 60 dB.

47 OTHER INSTRUMENTATION↗

Integration of 5G and Time Sensitive Networks in Fossil Energy Generation Systems: A Case Study

Precise timing and data transmission within stringent time constraints are critical for numerous applications, such as robotics, virtual and augmented reality, industrial automation, energy and medical business, and various other sectors. Time-sensitive networks (TSN) and fifth-generation wireless communications (5G) are crucial for industrial communications, enabling convergent communication for various services using a common network core. Applications that are time-sensitive and require deterministic communications with low latency fall into this category, such as generation plant systems. This paper presents a simulated model of 5G-TSN for a fossil power plant based on the wired network parameters implemented in situ. Metrics analysis, comparison and future work are presented. © 2024 IEEE.

01 COAL, LIGNITE, AND PEAT↗

A Novel Hollow Fiber Membrane Reactor for High Purity H 2 Generation from Thermal Catalytic NH 3 Decomposition (Final Report)

Ammonia (NH 3 ), as a promising carbon neutral liquid fuel (CNLF) and an effective H 2 source, can be synthesized from air and water (N 2 extracted from air and H 2 from water) using renewable energy sources. To produce H 2 as an intermediate, it is essential to develop effective and economic NH 3 decomposition technologies. We have been developing an innovative hollow fiber membrane reactor for high purity H 2 generation from thermal catalytic NH 3 decomposition. The objective of the proposed research is to fabricate a compact and robust prototype with high energy efficiency (>80%) to deliver high purity (>99%) H2 at high rate per volume (>0.15 g H 2 /h/cm 3 ) from NH3 decomposition at low temperature (<450 °C) and high conversion (>99%). Our overall technical approach is to effectively combine an active catalyst for NH 3 decomposition with a selective H 2 membrane separation process in a novel, compact modular system to generate high purity H 2 and simultaneously achieve high NH 3 conversion and optimize the entire system energy efficiency. This novel integrated membrane reactor design, together with low-cost, highly active Ru-based catalyst, makes it most appropriate for the project objective. The proposed applied research and development work, therefore, represents an innovative and transformational solution to H 2 generation from thermal catalytic NH 3 decomposition. During the course of our research we i) synthesized and characterized ruthenium(Ru)-based catalysts, evaluated their catalytic performance for NH 3 decomposition and optimized the catalyst composition and performance based on machine learning, ii) prepared SAPO-34, MFI membranes on α-alumina hollow fibers and measured their performance for H 2 /N 2 , H 2 /N 2 /NH 3 separation and evaluated carbon molecular sieve (CMS) and Pd/Ag membranes for H 2 /N 2 , H 2 /N 2 /NH 3 separation at different conditions, iii) designed and evaluated several types of membrane reactors for H 2 production from NH 3 decomposition, and iv) evaluated the H 2 delivery cost base on catalysts development, membrane development and membrane reactor. For 3,1,12 RuYK catalyst, H 2 productivity of 6.35 mmol/min/gcat with NH 3 conversion of 95~98% was achieved at 5 bar and 400 °C; for SAPO-34 membrane, the best membrane showed H 2 permeance of 7.56×10 -7 mol/(m 2 ∙s∙Pa) and H 2 /N 2 selectivity of 23.1 at 20 °C; For CMS and Pd/Ag membranes, both showed superior stability for 71%H 2 /24%N 2 /5%NH 3 mixture separation at 450 °C and 7 bar for over 120 h; for the membrane reactor, high H 2 purity of >99.99% with NH 3 conversion of >99.4% were achieved in Pd/Ag membrane reactor at 450 °C, and the NH 3 concentration was always below 10 ppb in H 2 product. The H 2 generation rate was calculated to be as high as 0.47 g/h/cm 3 and the energy efficiency was calculated to be 88%. The membrane reactor showed superior stability for over 370 h and high H 2 purity, H 2 production rate and NH 3 conversion. Based on calculation, the H 2 delivery cost can be as low as $3.66/kg.

08 HYDROGEN↗

Cybersecurity Technical Assistance Capabilities Overview [Slides]

Electric grids around the world are undergoing rapid structural and operational change, making it more important than ever to understand evolving risks and improve grid resilience and security against natural and human disruptions. Through tailored technical assistance, NREL is working with partners to support the secure and resilient deployment of energy systems and address grid integration challenges.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Exploring the Grid Value of Offshore Wind Energy in Oregon

The significant offshore wind energy potential of Oregon faces several challenges, including a power grid which was not developed for the purpose of transmitting energy from the ocean. The grid impacts of the energy resource are considered through the lenses of (i) resource complementarity with Variable Renewable Energy resources; (ii) correlations with load profiles from the four balancing authorities with territory in Oregon; and (iii) spatial value to regional and coastal grids as represented through a production cost model of the Western Interconnection. The capacity implications of the interactions between offshore wind and the historical east-to-west power flows of the region are discussed. The existing system is shown to accommodate more than two gigawatts of offshore wind interconnections with minimal curtailment. Through three gigawatts of interconnection, transmission flows indicate a reduction of coastal and statewide energy imports as well as minimal statewide energy exports.

17 WIND ENERGY↗