Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron capture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Influence of Prostatic Edema on {sup 131}CS Permanent Prostate Seed Implants: A Dosimetric and Radiobiological Study

Purpose: To study the influence of prostatic edema on postimplant physical and radiobiological parameters using {sup 131}Cs permanent prostate seed implants. Methods and Materials: Thirty-one patients with early prostate cancer who underwent {sup 131}Cs permanent seed implantation were evaluated. Dose-volume histograms were generated for each set of prostate volumes obtained at preimplantation and postimplantion days 0, 14, and 28 to compute quality indices (QIs) and fractional doses at level x (FD{sub x}). A set of equations for QI, FD{sub x}, and biologically effective doses at dose level D{sub x} (BED{sub x}) were defined to account for edema changes with time after implant. Results: There were statistically significant differences found between QIs of pre- and postimplant plans at day 0, except for the overdose index (ODI). QIs correlated with postimplant time, and FD{sub x} was found to increase with increasing postimplant time. With the effect of edema, BED at different dose levels showed less improvement due to the short half-life of {sup 131}Cs, which delivers about 85% of the prescribed dose before the prostate reaches its original volume due to dissipation of edema. Conclusions: Results of the study show that QIs, FD{sub x}, and BEDs at the level of D{sub x} changed from preneedle plans to postimplant plans and have statistically significant differences (p < 0.05), except for the ODI (p = 0.106), which suggests that at the time of {sup 131}C seed implantation, the effect of edema must be accounted for when defining the seed positions, to avoid the possibility of poor dosimetric and radiobiologic results for {sup 131}Cs seed implants.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose Reduction Study in Vaginal Balloon Packing Filled With Contrast for HDR Brachytherapy Treatment;HDR; Uterine cervix cancer; Vaginal balloon packing; Contrast; Monte Carlo

Purpose: Vaginal balloon packing is a means to displace organs at risk during high dose rate brachytherapy of the uterine cervix. We tested the hypothesis that contrast-filled vaginal balloon packing reduces radiation dose to organs at risk, such as the bladder and rectum, in comparison to water- or air-filled balloons. Methods and Materials: In a phantom study, semispherical vaginal packing balloons were filled with air, saline solution, and contrast agents. A high dose rate iridium-192 source was placed on the anterior surface of the balloon, and the diode detector was placed on the posterior surface. Dose ratios were taken with each material in the balloon. Monte Carlo (MC) simulations, by use of the MC computer program DOSXYZnrc, were performed to study dose reduction vs. balloon size and contrast material, including commercially available iodine- and gadolinium-based contrast agents. Results: Measured dose ratios on the phantom with the balloon radius of 3.4 cm were 0.922 {+-} 0.002 for contrast/saline solution and 0.808 {+-} 0.001 for contrast/air. The corresponding ratios by MC simulations were 0.895 {+-} 0.010 and 0.781 {+-} 0.010. The iodine concentration in the contrast was 23.3% by weight. The dose reduction of contrast-filled balloon ranges from 6% to 15% compared with water-filled balloon and 11% to 26% compared with air-filled balloon, with a balloon size range between 1.4 and 3.8 cm, and iodine concentration in contrast of 24.9%. The dose reduction was proportional to the contrast agent concentration. The gadolinium-based contrast agents showed less dose reduction because of much lower concentrations in their solutions. Conclusions: The dose to the posterior wall of the bladder and the anterior wall of the rectum can be reduced if the vaginal balloon is filled with contrast agent in comparison to vaginal balloons filled with saline solution or air.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Moving Toward Focal Therapy in Prostate Cancer: Dual-Isotope Permanent Seed Implants as a Possible Solution

Purpose: To compare the ability of single- and dual-isotope prostate seed implants to escalate biologically effective dose (BED) to foci of disease while reducing prescription dose to the prostate. Methods and Materials: Nine plans, using {sup 125}I, {sup 103}Pd, and {sup 131}Cs alone and in combination were created retrospectively for 2 patients. Ultrasound and MRI/MRS datasets were used for treatment planning. Voxel-by-voxel BED was calculated for single- and dual-isotope plans. Equivalent uniform BED (EUBED) was used to compare plans. The MRS-positive planning target volumes (PTV{sub i}) were delineated along with PTV (prostate + 5 mm), rectum, and urethra. Single-isotope implants, prescribed to conventional doses, were generated to achieve good PTV coverage. The PTV{sub i} were prospectively used to generate implants using mixtures of isotopes. For mixed-radioisotope implants, we also explored the impact on EUBED of lowering prescription doses by 15%. Results: The EUBED of PTV{sub i} in the setting of primary {sup 125}I implant increased 20-66% when {sup 103}Pd and {sup 131}Cs were used compared with {sup 125}I boost. Decreasing prescription dose by 15% in mixed-isotope implants results in a potential 10% reduction in urethral EUBED with preservation of PTV coverage while still boosting PTV{sub i} (up to 80%). When radiobiologic parameters corresponding to more-aggressive disease are assigned to foci, faster-decaying isotopes used in mixed implants have the potential to preserve the equivalent biological effect of mono-isotope implants considering less-aggressive disease distributed in the entire prostate. Conclusions: This is a hypothesis-generating study proposing a treatment paradigm that could be the middle ground between whole-gland irradiation and focal-only treatment. The use of two isotopes concurrent with decreasing the minimal peripheral dose is shown to increase EUBED of selected subvolumes while preserving the therapeutic effect at the level of the gland.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simultaneous {sup 68}Ga-DOTATOC-PET/MRI for IMRT Treatment Planning for Meningioma: First Experience

Purpose: To evaluate intensity-modulated radiotherapy (IMRT) treatment planning based on simultaneous positron-emission tomography and magnetic resonance imaging (PET/MRI) of meningioma. Methods and Materials: A meningioma patient was examined prior to radiotherapy with dedicated planning computed tomography (CT), MRI, PET/CT with gallium-68-labeled DOTATOC ({sup 68}Ga-DOTATOC), and simultaneous {sup 68}Ga-DOTATOC-PET/MRI. The first gross target volume (GTV) was defined based on a combination of separate MR and {sup 68}Ga-DOTATOC-PET/CT imaging (GTV{sub PET/CT+MR}). Then, the simultaneous PET/MR images were used to delineate a second GTV (GTV{sub PET/MR}) by following exactly the same delineation strategy. After an isotropic expansion of those volumes by a 4-mm safety margin, the resulting planning target volumes (PTVs) were compared by calculating the intersection volume and the relative complements. A cross-evaluation of IMRT plans was performed, where the treatment plan created for the PTV{sub PET/CT+MR} was applied to the PET/MR-based PTV{sub PET/MR}. Results: Generally, target volumes for IMRT treatment planning did not differ between MRI plus {sup 68}Ga-DOTATOC-PET/CT and simultaneous PET/MR imaging. Only in certain regions of the GTV were differences observed. The overall volume of the PET/MR-based PTV was approximately the same as that obtained from PET/CT data. A small region of infiltrative tumor growth next to the main tumor mass was better visualized with combined PET/MR due to smaller PET voxel sizes and improved recovery. An IMRT treatment plan was optimized for the PTV{sub PET/CT+MR}. The evaluation of this plan with respect to the PTV{sub PET/MR} showed parts of the target volume that would not have received the full radiation dose after delineation of the tumor, based on simultaneous PET/MR. Conclusion: This case showed that differences in target volumes delineated on the basis of separate MR and PET/CT and simultaneous PET/MR may be observed that can have significant consequences for an effectively applied radiotherapy treatment plan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose Constraint for Minimizing Grade 2 Rectal Bleeding Following Brachytherapy Combined With External Beam Radiotherapy for Localized Prostate Cancer: Rectal Dose-Volume Histogram Analysis of 457 Patients

Purpose: To determine the rectal tolerance to Grade 2 rectal bleeding after I-125 seed brachytherapy combined with external beam radiotherapy (EBRT), based on the rectal dose-volume histogram. Methods and Materials: A total of 458 consecutive patients with stages T1 to T3 prostate cancer received combined modality treatment consisting of I-125 seed implantation followed by EBRT to the prostate and seminal vesicles. The prescribed doses of brachytherapy and EBRT were 100 Gy and 45 Gy in 25 fractions, respectively. The rectal dosimetric factors were analyzed for rectal volumes receiving >100 Gy and >150 Gy (R100 and R150) during brachytherapy and for rectal volumes receiving >30 Gy to 40 Gy (V30-V40) during EBRT therapy in 373 patients for whom datasets were available. The patients were followed from 21 to 72 months (median, 45 months) after the I-125 seed implantation. Results: Forty-four patients (9.7%) developed Grade 2 rectal bleeding. On multivariate analysis, age (p = 0.014), R100 (p = 0.002), and V30 (p = 0.001) were identified as risk factors for Grade 2 rectal bleeding. The rectal bleeding rate increased as the R100 increased: 5.0% (2/40 patients) for 0 ml; 7.5% (20/267 patients) for >0 to 0.5 ml; 11.0% (11/100 patients) for >0.5 to 1 ml; 17.9% (5/28 patients) for >1 to 1.5 ml; and 27.3% (6/22 patients) for >1.5 ml (p = 0.014). Grade 2 rectal bleeding developed in 6.4% (12/188) of patients with a V30 {<=}35% and in 14.1% (26/185) of patients with a V30 >35% (p = 0.02). When these dose-volume parameters were considered in combination, the Grade 2 rectal bleeding rate was 4.2% (5/120 patients) for a R100 {<=}0.5 ml and a V30 {<=}35%, whereas it was 22.4% (13/58 patients) for R100 of >0.5 ml and V30 of >35%. Conclusion: The risk of rectal bleeding was found to be significantly volume-dependent in patients with prostate cancer who received combined modality treatment. Rectal dose-volume analysis is a practical method for predicting the risk of development of Grade 2 rectal bleeding.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiosensitization of Human Cervical Cancer Cells by Inhibiting Ribonucleotide Reductase: Enhanced Radiation Response at Low-Dose Rates

Purpose: To test whether pharmacologic inhibition of ribonucleotide reductase (RNR) by 3-aminopyridine-2-carboxaldehyde thiosemicarbazone (3-AP, NSC no. 663249) enhances radiation sensitivity during low-dose-rate ionizing radiation provided by a novel purpose-built iridium-192 cell irradiator. Methods and Materials: The cells were exposed to low-dose-rate radiation (11, 23, 37, 67 cGy/h) using a custom-fabricated cell irradiator or to high-dose-rate radiation (330 cGy/min) using a conventional cell irradiator. The radiation sensitivity of human cervical (CaSki, C33-a) cancer cells with or without RNR inhibition by 3-AP was evaluated using a clonogenic survival and an RNR activity assay. Alteration in the cell cycle distribution was monitored using flow cytometry. Results: Increasing radiation sensitivity of both CaSki and C33-a cells was observed with the incremental increase in radiation dose rates. 3-AP treatment led to enhanced radiation sensitivity in both cell lines, eliminating differences in cell cytotoxicity from the radiation dose rate. RNR blockade by 3-AP during low-dose-rate irradiation was associated with low RNR activity and extended G{sub 1}-phase cell cycle arrest. Conclusions: We conclude that RNR inhibition by 3-AP impedes DNA damage repair mechanisms that rely on deoxyribonucleotide production and thereby increases radiation sensitivity of human cervical cancers to low-dose-rate radiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Scatter Contribution and Distance Error by Iterative Methods for Strength Determination of HDR {sup 192}Ir Brachytherapy Source

High-dose rate (HDR) {sup 192}Ir brachytherapy sources are commonly used for management of malignancies by brachytherapy applications. Measurement of source strength at the hospital is an important dosimetry requirement. The use of 0.6-cm{sup 3} cylindrical ionization chamber is one of the methods of measuring the source strength at the hospitals because this chamber is readily available for beam calibration and dosimetry. While using the cylindrical chamber for this purpose, it is also required to determine the positioning error of the ionization chamber, with respect to the source, commonly called a distance error (c). The contribution of scatter radiation (M{sub s}) from floor, walls, ceiling, and other materials available in the treatment room also need to be determined accurately so that appropriate correction can be applied while calculating the source strength from the meter reading. Iterative methods of Newton-Raphson and least-squares were used in this work to determine scatter contribution in the experimentally observed meter reading (pC/s) of a cylindrical ionization chamber. Monte Carlo simulation was also used to cross verify the results of the least-squares method. The experimentally observed, least-squares calculated and Monte Carlo estimated values of meter readings from HDR {sup 192}Ir brachytherapy source were in good agreement. Considering procedural simplicity, the method of least-squares is recommended for use at the hospitals to estimate values of f (constant of proportionality), c, and M{sub s} required to determine the strength of HDR {sup 192}Ir brachytherapy sources.

07 ISOTOPE AND RADIATION SOURCES↗

A Study of Experimental Measurements of Dosimetric Parameters in HDR IR-192 Source

Thermoluminescent dosimeters have been used to perform dosimetry measurements for the widely used Ir-192 microSelectron-HDR source with an improved polystyrene phantom. Radial dose functions and anisotropy functions, main parameters of 2D dose-rate formalism from the TG-43U1 protocol, have been obtained experimentally. Measurement results are compared with that of the Monte Carlo calculations reported, and no difference has been found between them.

61 RADIATION PROTECTION AND DOSIMETRY↗

Anisotropy Characterization of I-125 Seed with Attached Encapsulated Cobalt Chloride Complex Contrast Agent Markers for MRI-Based Prostate Brachytherapy

We have developed a novel MRI marker for prostate brachytherapy. The purpose of this study was to evaluate the changes in anisotropy when cobalt chloride complex contrast agent encapsulated contrast agent markers (C4-ECAM) were placed adjacent to an iodine-125 (I-125) titanium seed, and to verify that the C4-ECAMs were visible on magnetic resonance imaging (MRI) after radiation exposure. Two C4-ECAMs were verified to be MRI visible in a phantom before radiation exposure. The C4-ECAMs were then attached to each end of a 12.7-U (10-mCi) I-125 titanium seed in a polymer tube. Anisotropy was measured and analyzed with the seed alone and with attached C4-ECAMs by suspending thermoluminescent dosimeters in a water phantom in 2 circles surrounding the radioactive source with radius of 1 or 2 cm. A T1-weighted MRI evaluation of C4-ECAMs was then performed after exposure to the amount of radiation typically delivered during 1 month of prostate brachytherapy. Measured values of the anisotropy function F(r, {theta}) for the I-125 seed with and without the C4-ECAMs were mutually statistically indistinguishable (standard error of the mean <4.2%) and agreed well with published TG-43 values for the bare seed. As expected, the anisotropy function {phi}{sub an}(r) for the 2 datasets (with and without C4-ECAMs) derived from the measured F(r, {theta}) did not exhibit statistically measurable difference. Both datasets showed agreement with the published TG-43 {phi}{sub an}(r) for the bare seed. The C4-ECAMs were well visualized by MRI after 1 month of radiation exposure. There were no changes in anisotropy when the C4-ECAMs were placed next to an I-125 radioactive seed, and the C4-ECAMs were visualized after radiation exposure.

61 RADIATION PROTECTION AND DOSIMETRY↗

Predicting thermophysical properties of molten salts in the MgCl 2 -NaCl-KCl-LiCl system with a shell-model potential

Ternary eutectic salts composed of MgCl 2 , NaCl, and KCl, referred to as MNK salts, have recently emerged as promising candidates as high-temperature heat transfer fluids and thermal energy storage media. Here we performed classical molecular dynamics (MD) simulations to predict the densities, specific heat capacities, viscosities, and ionic self-diffusivities for MNK salts over a wide temperature range. The impact of LiCl additive on their thermophysical properties was also investigated. To capture the electronic polarization of Cl anions by neighboring cations, we developed a novel shell-model potential using the force-matching method and a dataset of ab initio calculated interatomic forces. Our extensive MD simulations predict structure and properties for pure salts and binary/ternary salt mixtures in the MgCl 2 -NaCl-KCl-LiCl system in overall good agreement with available experimental and theoretical data, which corroborates the accuracy and reliability of our developed potential.

36 MATERIALS SCIENCE↗

Nuclear Data Sheets for A = 113

This evaluation for A = 113 updates one by J. Blachot, (2005Bl05), published in Nuclear Data Sheets 104, 791 (2005)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Data Sheets for A = 121

The 2000 Nuclear Data Sheets for A = 121 by T. Tamura, with literature cutoff date of July 1,1999 has been updated. The experimental results from various decays and reactions for A=121 mass chain have been compiled and evaluated. The nuclides covered in this evaluation are from {sup 121}Rh to {sup 121}Pr. The data are summarized and presented, together with adopted level schemes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Data Sheets for A = 168

Nuclear structure data pertaining to all nuclei with mass A=168 (Tb, Dy, Ho, Er, Tm, Yb, Lu, Hf, Ta, W, Re, Os, Ir, Pt) have been evaluated and incorporated into the ENSDF data file. This evaluation supersedes the previous publication (V.S. Shirley, Nuclear Data Sheets 71, 261 (1994) (literature cutoff date July 1993)) and subsequent ENSDF file revisions for Tb and Dy (C. Baglin, literature cutoff date of 15 June 1999) and Hf (B. Singh, literature cutoff date of 30 April 2001), and includes literature available by 15 June 2010. Since the above evaluations, the first excited states in {sup 168}Pt have been identified (1998Ki20, 2009Go16) and {alpha} decay from {sup 172}Hg has been observed (2009Sa27, 2004Ke06, 1999Se14). New levels in {sup 168}Dy have been excited using the {sup 170}Er({sup 82}Se,{sup 84}Kr{gamma}) reaction (2010So03). (HI,xn{gamma}) studies have significantly expanded our knowledge of level structure in {sup 168}Lu (1999Ka17, 2002Ha33), {sup 168}Ta (2008QiZZ), {sup 168}Yb (1995Fi01), {sup 168}Tm (2007CaZW), {sup 168}Hf (2009Ya21), {sup 168}Os (2001Jo11, 2009Od02) and, for {sup 168}Tm, important information has come also from (d,2n{gamma}) and ({alpha},n{gamma}) reactions (1995Si20). Revised decay schemes are available following new studies of {sup 168}Hf {epsilon} decay (6.7 min) (1997Ba26), {sup 168}Lu {epsilon} decay (1999Ba65), {sup 168}Ta {epsilon} decay (2007Mc08) and {sup 172}Au {alpha} decay (2009Ha42). Significant new information for {sup 168}Er is available from (p,t) (2006Bu09), (d,p) and (t,d) (1996Ma50), ({gamma},{gamma}') (1996Ma18), (136Xe, X{gamma}) (2010Dr02), ({sup 238}U,{sup 238}U{sup '{gamma}}) (2003Wu07) and (n,n{sup '{gamma}}) (1998Be20, 1998Be62) reactions, and the availability of {gamma}{gamma} coin data (1994Ju02, 1996Gi09) for the (n,{gamma}) E=thermal reaction has resulted in some significant level scheme revisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Data Sheets for A=182

Nuclear spectroscopic information for known nuclides of mass number 182 (Lu,Hf,Ta,W,Re,Os,Ir,Pt,Au,Hg, Tl,Pb) with Z=71 to 82 and N=111 to 100 have been evaluated and presented together with adopted energies and J{pi} of levels in these nuclei. No excited state data are yet available for {sup 182}Lu, while only limited structure information is available for {sup 182}Pb and {sup 182}Tl. Rotational band structures are known for {sup 182}Hg and {sup 182}Au but spin-parity assignments remain largely tentative. The decays of {sup 182}Lu, {sup 182}Hg, {sup 182}Au and {sup 182}Tl are not well established. The {sup 182}Hf isotope is of geophysical and astrophysical interest. This evaluation supersedes previous full evaluations of A=182 published by 1988Fi05 and 1975Sc13, and a selected (mainly high-spin) update of A=182 published by 1995Si04.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Data Sheets for A = 50

The experimental nuclear spectroscopic data for known nuclides of mass number 50 (Cl,Ar,K,Ca,Sc,Ti,V, Cr,Mn,Fe,Co,Ni) have been evaluated and presented together with Adopted properties for levels and {gamma} rays. This evaluation has been carried out about 15 years after the previous one by Thomas Burrows (1995Bu29). Except for {sup 50}Sc and {sup 50}V, extensive new data have become available for all the other nuclides in the intervening years. The data for {sup 50}Sc and {sup 50}V have also been checked again in detail and several changes made. No data are yet available for excited states in {sup 50}Cl, {sup 50}Ar and {sup 50}Ni. This work supersedes earlier evaluations (1995Bu29, 1990Bu18, 1984Al29, 1976Au07) of A=50 nuclides.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Data Sheets for A = 71

The evaluated spectroscopic data are presented for experimentally known nuclides of mass 71 (Mn,Fe,Co,Ni,Cu,Zn,Ga,Ge,As,Se,Br,Kr). Excited-state data are nonexistent for {sup 71}Mn, {sup 71}Fe, {sup 71}Co and {sup 71}Kr. Significant new data have been added since the last evaluation of A=71 nuclides by M. Bhat (1993Bh02). Excited states are now known in {sup 71}Ni and {sup 71}Cu, and enhanced information about high-spin excitations is available for {sup 71}Ga, {sup 71}As and {sup 71}Br. The decay schemes of radioactive isotopes {sup 71}Mn and {sup 71}Fe are not known at all, and those for {sup 71}Co, {sup 71m}Ni and {sup 71}Kr are not known well. For the decay of {sup 71}Cu, {sup 71g}Ni, and {sup 71}Br, extensive data are available, but in the opinion of the evaluators the decay schemes still seem incomplete. This work supersedes earlier full evaluations of A=71 published by 1988Bh01, 1979Ke06 and 1973Al33, and the last one published in 'update' mode by 1993Bh02.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Data Sheets for A = 125

The 1999 evaluation for A = 125 mass chain (1999Ka26) has been revised using experimental results from decays and reactions. Adopted values for the level and decay properties are tabulated. Inconsistencies and discrepancies are noted.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Data Sheets for A = 207

Evaluated nuclear structure and decay data for all nuclei within the A=207 mass chain are presented. The experimental data are evaluated and best values for level and gamma-ray energies, quantum numbers, lifetimes, gamma-ray intensities, and other nuclear properties are recommended. Inconsistencies and discrepancies that exist in the literature are noted. This work supersedes the earlier evaluation by M.J. Martin (1993Ma73), published in Nuclear Data Sheets70, 315 (1993).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗