Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “drops”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Collective effects of temperature gradients and gravity on droplet coalescence

The interaction and coalescence of small spherical drops in dilute, homogeneous dispersions are considered theoretically under conditions, where drop motion results from gravity settling and thermocapillary migration acting simultaneously. A trajectory analysis is used to predict pairwise collision rates, and population dynamics equations are solved to predict the time evolution of the droplet size distribution. The rate of droplet collisions and growth may be reduced dramatically by antiparallel alignment of the gravitational and thermocapillary velocities. For such antiparallel alignment with the gravitational relative velocity exceeding the thermocapillary relative velocity for two widely separated drops, there is a 'collision-forbidden region' in parameter space. This occurs because the gravitational relative velocity decays more rapidly with decreasing separation distance between the drops than does the thermocapillary relative velocity, and so the resultant relative velocity along the line-of-centers from these two sources combined becomes zero at a finite separation and the drops are unable to collide. As a result, small drops which initially collide and coalesce due to thermocapillary motion will only grow until they reach a critical size for which the oppositely directed gravitational motion balances the thermocapillary motion.

Zhang, Xiaoguang↗

Ground based research in microgravity materials processing

The core activities performed during this time period have been concerned with tracking the TEMPEST experiments on the shuttle with drops of Zr, Ni, and Nb alloys. In particular a lot of Zr drops are being made to better define the recalescence characteristics of that system so that accurate comparisons of the drop tube results with Tempest can be made. A new liner, with minimal reflectivity characteristics, has been inserted into the drop tube in order to improve the recalescence measurements of the falling drops. The first installation to make the geometric measurements to ensure a proper fit has been made. The stovepipe sections are currently in the shop at MSFC being painted with low reflectivity black paint. Work has also continued on setting up the MEL apparatus obtained from Oak Ridge in the down stairs laboratory at the Drop Tube Facilities. Some ground-based experiments on the same metals as are being processed on TEMPEST are planned for the MEL. The flight schedules for the KC-135 experiments are still to be determined in the near future.

Workman, Gary L.↗

Interhemispheric asymmetry of the high-latitude ionospheric convection pattern

The assimilative mapping of ionospheric electrodynamics technique has been used to derive the large-scale high-latitude ionospheric convection patterns simultaneously in both northern and southern hemispheres during the period of January 27 to 29, 1992. When the interplanetary magnetic field (IMF) B(sub z) component is negative, the convection patterns in the southern hemisphere are basically the mirror images of those in the northern hemisphere. The total cross-polar cap potential drops in the two hemispheres are similar. When B(sub z) is positive and absolute value of B(sub y) greater than B(sub z), the convection configurations are mainly determined by B(sub y) and they may appear as normal 'two-cell' patterns in both hemispheres much as one would expect under southward IMF conditions. However, there is a significant difference in the cross-polar-cap potential drop between the two hemispheres, with the potential drop in the southern (summer) hemisphere over 50% larger than that in the northern (winter) hemisphere. As the ratio of absolute value of B(sub y)/B(sub z) decreases (less than one), the convection configuration in the two hemispheres may be significantly different, with reverse convection in the southern hemisphere and weak but disturbed convection in the northern hemisphere. By comparing the convection patterns with the corresponding spectrograms of precipitating particles, we interpret the convection patterns in terms of the concept of merging cells, lobe cells, and viscous cells. Estimates of the ' merging cell' potential drops, that is, the potential ascribed to the opening of the dayside field lines, are usually comparable between the two hemispheres, as they should be. The 'lobe cell' provides a potential between 8.5 and 26 kV and can differ greatly between hemispheres, as predicted. Lobe cells can be significant even for southward IMF, if absolute value of B(sub y) greater than the absolute value of B(sub z). To estimate the potential drop of the 'viscous cells,' we assume that the low-latitude boundary layer is on closed field lines. We find that this potential drop varies from case to case, with a typical value of 10 kV. If the source of these cells is truly a viscous interaction at the flank of the magnetopause, the process is likely spatially and temporally varying rather than steady state.

Lu, G.↗

Tectonic plates, D (double prime) thermal structure, and the nature of mantle plumes

It is proposed that subducting tectonic plates can affect the nature of thermal mantle plumes by determining the temperature drop across a plume source layer. The temperature drop affects source layer stability and the morphology of plumes emitted from it. Numerical models are presented to demonstrate how introduction of platelike behavior in a convecting temperature dependent medium, driven by a combination of internal and basal heating, can increase the temperature drop across the lower boundary layer. The temperature drop increases dramatically following introduction of platelike behavior due to formation of a cold temperature inversion above the lower boundary layer. This thermal inversion, induced by deposition of upper boundary layer material to the system base, decays in time, but the temperature drop across the lower boundary layer always remains considerably higher than in models lacking platelike behavior. On the basis of model-inferred boundary layer temperature drops and previous studies of plume dynamics, we argue that generally accepted notions as to the nature of mantle plumes on Earth may hinge on the presence of plates. The implication for Mars and Venus, planets apparently lacking plate tectonics, is that mantle plumes of these planets may differ morphologically from those of Earth. A corollary model-based argument is that as a result of slab-induced thermal inversions above the core mantle boundary the lower most mantle may be subadiabatic, on average (in space and time), if major plate reorganization timescales are less than those acquired to diffuse newly deposited slab material.

Lenardic, A.↗

Comparison of High Aspect Ratio Cooling Channel Designs for a Rocket Combustion Chamber

An analytical investigation on the effect of high aspect ratio (height/width) cooling channels, considering different coolant channel designs, on hot-gas-side wall temperature and coolant pressure drop for a liquid hydrogen cooled rocket combustion chamber, was performed. Coolant channel design elements considered were: length of combustion chamber in which high aspect ratio cooling was applied, number of coolant channels, and coolant channel shape. Seven coolant channel designs were investigated using a coupling of the Rocket Thermal Evaluation code and the Two-Dimensional Kinetics code. Initially, each coolant channel design was developed, without consideration for fabrication, to reduce the hot-gas-side wall temperature from a given conventional cooling channel baseline. These designs produced hot-gas-side wall temperature reductions up to 22 percent, with coolant pressure drop increases as low as 7.5 percent from the baseline. Fabrication constraints for milled channels were applied to the seven designs. These produced hot-gas-side wall temperature reductions of up to 20 percent, with coolant pressure drop increases as low as 2 percent. Using high aspect ratio cooling channels for the entire length of the combustion chamber had no additional benefit on hot-gas-side wall temperature over using high aspect ratio cooling channels only in the throat region, but increased coolant pressure drop 33 percent. Independent of coolant channel shape, high aspect ratio cooling was able to reduce the hot-gas-side wall temperature by at least 8 percent, with as low as a 2 percent increase in coolant pressure drop. The design with the highest overall benefit to hot-gas-side wall temperature and minimal coolant pressure drop cooling can now be done in relatively short periods of time with multiple iterations.

Wadel, Mary F.↗

Combustion of Unconfined Droplet Clusters in Microgravity

Combustion experiments using arrays of droplets seek to provide a link between single droplet combustion phenomena and the behavior of complex spray combustion systems. Both single droplet and droplet array studies have been conducted in microgravity to better isolate the droplet interaction phenomena and eliminate or reduce the confounding effects of buoyancy-induced convection. In most experiments involving droplet arrays, the droplets are supported on fibers to keep them stationary and close together before the combustion event. The presence of the fiber, however, disturbs the combustion process by introducing a source of heat transfer and asymmetry into the configuration. As the number of drops in a droplet array increases, supporting the drops on fibers becomes less practical because of the cumulative effect of the fibers on the combustion process. To eliminate the effect of the fiber, several researchers have conducted microgravity experiments using unsupported droplets. Jackson and Avedisian investigated single, unsupported drops while Nomura et al. studied droplet clouds formed by a condensation technique. The overall objective of this research is to extend the study of unsupported drops by investigating the combustion of well-characterized drop clusters in a microgravity environment. Direct experimental observations and measurements of the combustion of droplet clusters would fill a large gap in our current understanding of droplet and spray combustion and provide unique experimental data for the verification and improvement of spray combustion models. In this work, the formation of drop clusters is precisely controlled using an acoustic levitation system so that dilute, as well as dense clusters can be created and stabilized before combustion in microgravity is begun. This paper describes the design and performance of the 1-g experimental apparatus, some preliminary 1-g results, and plans for testing in microgravity.

Ruff, G. A.↗

Experimental Measurements of Spreading of Volatile Liquid Droplets

Based on the laser shadowgraphic system used by the first author of the present paper, a simple optical system, which combined the laser shadowgraphy and the direct magnified-photography, has been developed to measure the contact angle, the spreading speed, and the evaporation rate. Additionally, the system can also visualize thermocapillary convection inside of a sessile drop simultaneously. The experimental results show that evaporation/condensation and thermocapillary convection in the sessile drop induced by the evaporation strongly affects the wetting and spreading of the drop. Condensation always promotes the wetting and spreading of the drop. Evaporation may increase or decrease the contact angle of the evaporating sessile drops, depending on the evaporation rate. The thermocapillary convection in the drop induced by the evaporation enhances the effects of evaporation to suppress the spreading.

Zhang, Neng-Li↗

Droplet Vaporization In A Levitating Acoustic Field

Combustion experiments using arrays of droplets seek to provide a link between single droplet combustion phenomena and the behavior of complex spray combustion systems. Both single droplet and droplet array studies have been conducted in microgravity to better isolate the droplet interaction phenomena and eliminate or reduce the effects of buoyancy-induced convection. In most experiments involving droplet arrays, the droplets are supported on fibers to keep them stationary and close together before the combustion event. The presence of the fiber, however, disturbs the combustion process by introducing a source of heat transfer and asymmetry into the configuration. As the number of drops in a droplet array increases, supporting the drops on fibers becomes less practical because of the cumulative effect of the fibers on the combustion process. To eliminate the effect of the fiber, several researchers have conducted microgravity experiments using unsupported droplets. Jackson and Avedisian investigated single, unsupported drops while Nomura et al. studied droplet clouds formed by a condensation technique. The overall objective of this research is to extend the study of unsupported drops by investigating the combustion of well-characterized drop clusters in a microgravity environment. Direct experimental observations and measurements of the combustion of droplet clusters would provide unique experimental data for the verification and improvement of spray combustion models. In this work, the formation of drop clusters is precisely controlled using an acoustic levitation system so that dilute, as well as dense clusters can be created and stabilized before combustion in microgravity is begun. While the low-gravity test facility is being completed, tests have been conducted in 1-g to characterize the effect of the acoustic field on the vaporization of single and multiple droplets. This is important because in the combustion experiment, the droplets will be formed and levitated prior to ignition. Therefore, the droplets will begin to vaporize in the acoustic field thus forming the "initial conditions" for the combustion process. Understanding droplet vaporization in the acoustic field of this levitator is a necessary step that will help to interpret the experimental results obtained in low-gravity.

Ruff, G. A.↗

Fixed Packed Bed Reactors in Reduced Gravity

We present experimental data on flow pattern transitions, pressure drop and flow characteristics for cocurrent gas-liquid flow through packed columns in microgravity. The flow pattern transition data indicates that the pulse flow regime exists over a wider range of gas and liquid flow rates under microgravity conditions compared to 1-g and the widely used Talmor map in 1-g is not applicable for predicting the transition boundaries. A new transition criterion between bubble and pulse flow in microgravity is proposed and tested using the data. Since there is no static head in microgravity, the pressure drop measured is the true frictional pressure drop. The pressure drop data, which has much smaller scatter than most reported 1-g data clearly shows that capillary effects can enhance the pressure drop (especially in the bubble flow regime) as much as 200% compared to that predicted by the single phase Ergun equation. The pressure drop data are correlated in terms of a two-phase friction factor and its dependence on the gas and liquid Reynolds numbers and the Suratman number. The influence of gravity on the pulse amplitude and frequency is also discussed and compared to that under normal gravity conditions. Experimental work is planned to determine the gas-liquid mass transfer coefficients. Because of enhanced interfacial effects, we expect the gas-liquid transfer coefficients k(L)a and k(G)a (where a is the gas-liquid interfacial area) to be higher in microgravity than in normal gravity at the same flow conditions. This will be verified by gas absorption experiments, with and without reaction in the liquid phase, using oxygen, carbon dioxide, water and dilute aqueous amine solutions. The liquid-solid mass transfer coefficient will also be determined in the bubble as well as the pulse flow regimes using solid benzoic acid particles in the packing and measuring their rate of dissolution. The mass transfer coefficients in microgravity will be compared to those in normal gravity cocurrent flow to determine the mass transfer enhancement and propose new mass transfer correlations for two-phase gas-liquid flows through packed beds in microgravity.

Motil, Brian J.↗

Fixed Packed Bed Reactors in Reduced Gravity

We present experimental data on flow pattern transitions, pressure drop and flow characteristics for cocurrent gas-liquid flow through packed columns in microgravity. The flow pattern transition data indicates that the pulse flow regime exists over a wider range of gas and liquid flow rates under microgravity conditions compared to 1-g and the widely used Talmor map in 1-g is not applicable for predicting the transition boundaries. A new transition criterion between bubble and pulse flow in microgravity is proposed and tested using the data. Since there is no static head in microgravity, the pressure drop measured is the true frictional pressure drop. The pressure drop data, which has much smaller scatter than most reported 1-g data clearly shows that capillary effects can enhance the pressure drop (especially in the bubble flow regime) as much as 200% compared to that predicted by the single phase Ergun equation. The pressure drop data are correlated in terms of a two-phase friction factor and its dependence on the gas and liquid Reynolds numbers and the Suratman number. The influence of gravity on the pulse amplitude and frequency is also discussed and compared to that under normal gravity conditions. Experimental work is planned to determine the gas-liquid and liquid-solid mass transfer coefficients. Because of enhanced interfacial effects, we expect the gas-liquid transfer coefficients kLa and kGa (where a is the gas-liquid interfacial area) to be higher in microgravity than in normal gravity at the same flow conditions. This will be verified by gas absorption experiments, with and without reaction in the liquid phase, using oxygen, carbon dioxide, water and dilute aqueous amine solutions. The liquid-solid mass transfer coefficient will also be determined in the bubble as well as the pulse flow regimes using solid benzoic acid particles in the packing and measuring their rate of dissolution. The mass transfer coefficients in microgravity will be compared to those in normal gravity cocurrent flow to determine the mass transfer enhancement and propose new mass transfer correlations for two-phase gas-liquid flows through packed beds in microgravity.

Motil, Brian J.↗

Evaluation of Open Cell Foam Heat Transfer Enhancement for Liquid Rocket Engine

As NASA pursues the exploration mission, advanced propulsion for the next generation of spacecraft will be needed. These new propulsion systems will require higher performance and increased durability, despite current limitations on materials. A break-through technology is needed in the thrust chamber. In this paper the idea of using a porous metallic foam is examined for its potential cooling enhancement capabilities. The goal is to increase the chamber wall cooling without creating an additional pressure drop penalty. A feasibility study based on experiments at laboratory-scale conditions was performed and analysis at rocket conditions is underway. In the experiment, heat transfer and pressure drop data were collected using air as the coolant in a copper or nickel foam filled annular channel. The foam-channel performance was evaluated based on comparison with conventional microchannel cooling passages under equal pressure drop conditions. The heat transfer enhancement of the foam channel over the microchannel ranges from 130% to 172%. The enhancement is relatively independent of the pressure drop and increases with decreasing pore size. A direct numerical simulation model of the foam heat exchange has been built. The model is based on the actual metal foam microstructure of thin ligaments (0.2- 0.3 mm in diameter) that form a network of interconnected open-cells. The cell dimension is around 2 mm. The numerical model was built using the FLUENT CFD code. Comparison of the pressure drop results predicted by the current model with those experimental data of Leong and Jin [8] shows favorable comparisons. Pressure drop predictions have been made using hydrogen as a coolant at typical rocket conditions. Conjugate heat transfer analysis using the foam filled channel is planned for the future.

Chung, J. N.↗

Magnetic Clouds at/near the 2007 - 2009 Solar Minimum: Frequency of Occurrence and Some Unusual Properties

Magnetic clouds (MCs) have been identified for the period 2007 2009 (at/near the recent solar minimum) from Wind data, then confirmed through MC parameter fitting using a force-free model. A dramatic increase in the frequency of occurrence of these events took place from the two early years of 2007 (with five MCs) and 2008 (one MC) compared to 2009 (12 MCs). This pattern approximately mirrors the occurrence-frequency profile that was observed over a three-year interval 12 years earlier, with eight events in 1995, four in 1996, and 17 in 1997, but decreased overall by a factor of 0.62 in number. However, the average estimated axial field strength taken over all of the 18 events of 2007 - 2009 (called the "recent period" here) was only 11.0 nT, whereas |BO| for the 29 events of 1995 - 1997 (called the "earlier period" ) was 16.5 nT. This 33% average drop in |BO| is more or less consistent with the decreased three-year average interplanetary magnetic field intensity between these two periods, which shows a 23% drop. In the earlier period, the MCs were clearly of mixed types but predominantly of the South-to-North type, whereas those in the recent period are almost exclusively the North-to-South type; this change is consistent with global solar field changes predicted by Bothmer and Rust (Geophys. Monogr. Ser. 99, 139, 1997). As we have argued in earlier work (Lepping and Wu, J. Geophys. Res. 112, A10103, 2007), this change should make it possible to carry out (accurate short-term) magnetic storm forecasting by predicting the latter part of an MC from the earlier part, using a good MC parameter-fitting model with real-time data from a spacecraft at L1, for example. The recent set s average duration is 15.2 hours, which is a 27% decrease compared to that of the earlier set, which had an average duration of 20.9 hours. In fact, all physical aspects of the recent MC set are shown to drop with respect to the earlier set; e.g., as well as the average internal magnetic field drop, the recent set had a somewhat low average speed of 379 km/s (5% drop), and the average diameter had a 24% drop. Hence, compared to the earlier set, the recent set consists of events that are smaller, slightly slower, and weaker in every respect (and fewer in number), but in a relative sense the two three-year sets have similar frequency-of-occurrence profiles. It is also interesting that the two sets have almost the same average axial inclinations, i.e., axial latitude approx. = 31deg (in GSE). These MC characteristics are compared to relevant solar features and their changes. A preliminary assessment of the statistics on possible shocks and pressure pulses upstream of these recent MCs yields the following: About 28% of the MCs, at most, had shocks, and 33% had shocks and/or pressure pulses. These are low values, since typically the percentage of cases with shocks is about 50%, and the percentage with shocks and/or pressure pulses is usually about 75%.

Lepping. R. P.↗

Characterization of Rapid Charging Events Due to Sheath Capacitance and Impact on the International Space Station Plasma Hazard Process

During an Extravehicular Activity (EVA), if the Extravehicular Mobility Unit (EMU) makes galvanic contact with the International Space Station (ISS), a negative Floating Potential (FP) can lead to an arcing hazard when it exceeds -45.5 V, and a positive FP can produce a DC current high enough to stimulate the astronaut’s muscles (5 mA), and also cause a hazard. The Boeing Space Environments team developed and utilizes a Plasma Interaction Model (PIM) in order to calculate the ISS FP based on the plasma environment, ISS velocity, geomagnetic field, solar array and ISS orientation, and solar array regulation to support EVA planning operations. Presently, the model excludes the sheath capacitance, resulting in the total potential drop being across the dielectric surface of the vehicle. Data from the Floating Potential Measurement Unit (FPMU) show this assumption to be generally true. However, Rapid Charging Events (RCE) are often observed in the FPMU data at eclipse exit when the electron number density, Ne, is low (less than 5(sub e)10 m (exp-3)). During these events, the FP can rise more than 40 V in one to five seconds. There is then a relaxation phase where the FP drops back to the normal FP values. The PIM model is not capable of producing these RCEs. It was thought that the inclusion of the sheath in PIM could improve the charging predictions, particularly as related to RCEs. A parametric study was performed to determine what portion of the measured FP is across the sheath for a range of Ne experienced by the ISS, and if the inclusion of the sheath in PIM is necessary. Results show that the potential drop across the sheath is negligible at times when the N(sub e) is greater than 1(sub e)11 m-3. However, there appears to be a transitional region between 1(sub e)10 m(exp -3) and 1(sub e)11 m(exp -3) where the sheath capacitance becomes more significant. During those conditions the potential drop across the sheath can be larger than the potential drop across the dielectric for short periods (1-5 seconds). These results agree remarkably well with measurements made by the FPMU. The inclusion of the sheath explains why high charging measurements occur when the Ne is low at eclipse exit and even times when the solar arrays are not a significant driver (i.e., potentials often rise as the ISS flies through spread-F). Results also show that the RCEs are not a safety concern because the potential drop across the dielectric surface does not exceed -45.5 V. In that case, the EMU would not arc. This gives high confidence in the low probability of an arcing hazard occurring.

plasma environment↗

Computational Icing Risk Analysis of the D8 "Double Bubble" Aircraft

A computational icing risk analysis utilizing LEWICE3D was performed for the D8 Double Bubble aircraft. A variety of discrete drop sizes spanning the Appendix C and O regimes were simulated. For computational efficiency a 50-bin global discretization was produced and projected onto the distributions of interest, eliminating redundant simulations. The trajectory and impingement characteristics for discrete drop diameters were analyzed to help understand the behavior of the water drops in the presence of a complex flow field. The collection efficiency results for the discrete drop diameters were then weighted by their contributions to the total water content of six different continuous distributions and subsequently superposed to approximate these curves. Results indicate that significant variation in impingement exists as a function of drop diameter for complex wing body geometries, and that current discretization practices may be insufficient to accurately predict water collection on certain regions of the aircraft. Results also indicate that the Appendix O distributions, specifically those with considerable water content at large drops, generates water collection patterns that are markedly different from distributions representative of Appendix C.

icing↗

Computational Icing Risk Analysis of the D8 "Double Bubble" Aircraft

A computational icing risk analysis utilizing LEWICE3D was performed for the D8 Double Bubble aircraft. A variety of discrete drop sizes spanning the Appendix C and O regimes were simulated. For computational efficiency a 50-bin global discretization was produced and projected onto the distributions of interest, eliminating redundant simulations. The trajectory and impingement characteristics for discrete drop diameters were analyzed to help understand the behavior of the water drops in the presence of a complex flow field. The collection efficiency results for the discrete drop diameters were then weighted by their contributions to the total water content of six different continuous distributions and subsequently superposed to approximate these curves. Results indicate that significant variation in impingement exists as a function of drop diameter for complex wing body geometries, and that current discretization practices may be insufficient to accurately predict water collection on certain regions of the aircraft. Results also indicate that the Appendix O distributions, specifically those with considerable water content at large drops, generates water collection patterns that are markedly different from distributions representative of Appendix C.

Porter, Christopher E.↗

Bimodal SLD Ice Accretion on Swept NACA 0012 Airfoil Models

An ice shape database has been created to document ice accretions on a swept 15-inch chord NACA0012 model and a swept 36-inch chord NACA0012 airfoil model resulting from an exposure to a Supercooled Large Drop (SLD) icing cloud with a bimodal drop size distribution. The ice shapes created were documented with photographs, laser scanned surface measurements over a section of the model span, and measurement of the ice mass over the same section of each accretion. The icing conditions were based on a series of reference conditions that were previously used to generate ice shapes on these models. Drop distribution effects were evaluated by using the same IRT icing conditions except with either monomodal or bimodal drop distributions. Ice shapes resulting from the bimodal distribution as well as from equivalent monomodal drop size distributions were obtained and compared. Results indicate that the ice shapes and mass values from the monomodal and bimodal drop size distributions were the same within the range of repeatability for the conditions tested in this campaign.

Icing↗

Bimodal SLD Ice Accretion on a CRM Midspan Wing Section Model

An ice shape database has been created to document ice accretions on a 65 per cent scale version of the mid-span section of the Common Research Model resulting from an exposure to a Supercooled Large Drop (SLD) icing cloud with a bimodal drop size distribution. The ice shapes created were documented with photographs, laser scanned surface measurements over a section of the model span, and measurement of the ice mass over the same section of each accretion. Drop distribution effects were evaluated by using the same IRT icing conditions except with either monomodal or bimodal drop distributions. Ice shapes resulting from the bimodal distribution as well as from equivalent monomodal drop size distributions were obtained and compared. Results indicate that the ice shapes resulting from the monomodal and bimodal drop size distributions had equivalent mass and volume, as expected with this approach. Note: No audio portion for this record, additionally slide 9 has a playable video but must be downed in order to view.

Icing↗

Some microphysical features of coastal and inland fogs.

Radiation fogs sampled at Los Angeles were found to possess low visibilities, high liquid water content (LWC), relatively small drops, narrow peaked drop-size distributions, and high concentrations of micron sized haze droplets. Typical characteristics of valley fogs observed at Elmira, N.Y., were low visibilities, moderately high LWC, low concentrations of haze droplets, and similar drop size distributions to those measured in Los Angeles. On the other hand, advection fogs observed in Vandenberg were characterized by less severe visibilities, low LWC, large drops in a broad drop-size distribution, and very low haze nucleus concentrations.

Mack, E. J.↗