Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “direct detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Photon counting with intensified charge coupled device (ICCD) – II. Laser induced breakdown spectroscopy (LIBS) spectral measurement

This study explores the application of photon counting (PC) to enhance the resolution of spectra acquired by an intensified charge-coupled device (ICCD) detector, with a focus on analytical atomic emission spectrometry using laser-induced breakdown spectroscopy (LIBS) as a use-case example. It demonstrates that, for spectra obtained with the same spectrometer–ICCD system, PC provides higher spectral resolution compared to conventional analog detector readout. This enhancement is particularly evident in the line wings of spectral peaks, facilitating better discrimination of isotopic peaks in the measured spectra. Although PC does not improve the resolution of an optical spectrometer directly, it rectifies the resolution lost caused by signal spreading in conventional ICCD analog measurement. However, similar to other counting techniques, excessive photons compromise detector linearity due to signal pileup. A correction model is proposed to mitigate the pileup effect, resulting in improved linearity and dynamic range in PC measurements. Additionally, the study reveals unexpected periodic structures in the flatfield image of the ICCD, which cause non-uniform detector gain in conventional analog as well as PC measurement modes and must be addressed for high-precision measurements.

47 OTHER INSTRUMENTATION↗

Determining the bubble nucleation efficiency of low-energy nuclear recoils in superheated C 3 F 8 dark matter detectors

The bubble nucleation efficiency of low-energy nuclear recoils in superheated liquids plays a crucial role in interpreting results from direct searches for weakly interacting massive particle (WIMP) dark matter. Here, the PICO collaboration presents the results of the efficiencies for bubble nucleation from carbon and fluorine recoils in superheated C 3 F 8 from calibration data taken with five distinct neutron spectra at various thermodynamic thresholds ranging from 2.1 to 3.9 keV. Instead of assuming any particular functional forms for the nuclear recoil efficiency, a generalized piecewise linear model is proposed with systematic errors included as nuisance parameters to minimize model-introduced uncertainties. A Markov chain Monte Carlo routine is applied to sample the nuclear recoil efficiency for fluorine and carbon at 2.45 and 3.29 keV thermodynamic thresholds simultaneously. The nucleation efficiency for fluorine was found to be ≥ 50% for nuclear recoils of 3.3 keV (3.7 keV) at a thermodynamic Seitz threshold of 2.45 keV (3.29 keV), and for carbon the efficiency was found to be ≥ 50% for recoils of 10.6 keV (11.1 keV) at a threshold of 2.45 keV (3.29 keV). Simulated datasets are used to calculate a p value for the fit, confirming that the model used is compatible with the data. The fit paradigm is also assessed for potential systematic biases, which although small, are corrected for. Additional steps are performed to calculate the expected interaction rates of WIMPs in the PICO-60 detector, a requirement for calculating WIMP exclusion limits.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ANTARES Constrains a Blazar Origin of Two IceCube PeV Neutrino Events

Context. The source(s) of the neutrino excess reported by the IceCube Collaboration is unknown. The TANAMI Collaboration recently reported on the multiwavelength emission of six bright, variable blazars which are positionally coincident with two of the most energetic IceCube events. Objects like these are prime candidates to be the source of the highest-energy cosmic rays, and thus of associated neutrino emission. Aims. We present an analysis of neutrino emission from the six blazars using observations with the ANTARES neutrino telescope. Methods. The standard methods of the ANTARES candidate list search are applied to six years of data to search for an excess of muons - and hence their neutrino progenitors - from the directions of the six blazars described by the TANAMI Collaboration, and which are possibly associated with two IceCube events. Monte Carlo simulations of the detector response to both signal and background particle fluxes are used to estimate the sensitivity of this analysis for di erent possible source neutrino spectra. A maximum-likelihood approach, using the reconstructed energies and arrival directions of through-going muons, is used to identify events with properties consistent with a blazar origin. Results. Both blazars predicted to be the most neutrino-bright in the TANAMI sample (1653-329 and 1714-336) have a signal flux fitted by the likelihood analysis corresponding to approximately one event. This observation is consistent with the blazar-origin hypothesis of the IceCube event IC 14 for a broad range of blazar spectra, although an atmospheric origin cannot be excluded. No ANTARES events are observed from any of the other four blazars, including the three associated with IceCube event IC20. This excludes at a 90% confidence level the possibility that this event was produced by these blazars unless the neutrino spectrum is flatter than -2.4.

general↗

Determining the bubble nucleation efficiency of low-energy nuclear recoils in superheated C$_3$F$_8$ dark matter detectors

The bubble nucleation efficiency of low-energy nuclear recoils in superheated liquids plays a crucial role in interpreting results from direct searches for weakly interacting massive particle (WIMP) dark matter. The PICO Collaboration presents the results of the efficiencies for bubble nucleation from carbon and fluorine recoils in superheated C$_3$F$_8$ from calibration data taken with 5 distinct neutron spectra at various thermodynamic thresholds ranging from 2.1 keV to 3.9 keV. Instead of assuming any particular functional forms for the nuclear recoil efficiency, a generalized piecewise linear model is proposed with systematic errors included as nuisance parameters to minimize model-introduced uncertainties. A Markov-Chain Monte-Carlo (MCMC) routine is applied to sample the nuclear recoil efficiency for fluorine and carbon at 2.45 keV and 3.29 keV thermodynamic thresholds simultaneously. The nucleation efficiency for fluorine was found to be $\geq 50\, \%$ for nuclear recoils of 3.3 keV (3.7 keV) at a thermodynamic Seitz threshold of 2.45 keV (3.29 keV), and for carbon the efficiency was found to be $\geq 50\, \%$ for recoils of 10.6 keV (11.1 keV) at a threshold of 2.45 keV (3.29 keV). Simulated data sets are used to calculate a p-value for the fit, confirming that the model used is compatible with the data. The fit paradigm is also assessed for potential systematic biases, which although small, are corrected for. Additional steps are performed to calculate the expected interaction rates of WIMPs in the PICO-60 detector, a requirement for calculating WIMP exclusion limits.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstruction of events recorded with the surface detector of the Pierre Auger Observatory

Cosmic rays arriving at Earth collide with the upper parts of the atmosphere, thereby inducing extensive air showers. When secondary particles from the cascade arrive at the ground, they are measured by surface detector arrays. We describe the methods applied to the measurements of the surface detector of the Pierre Auger Observatory to reconstruct events with zenith angles less than $60^\circ$ using the timing and signal information recorded using the water-Cherenkov detector stations. In addition, we assess the accuracy of these methods in reconstructing the arrival directions of the primary cosmic ray particles and the sizes of the induced showers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser Range and Bearing Finder with No Moving Parts

A proposed laser-based instrument would quickly measure the approximate distance and approximate direction to the closest target within its field of view. The instrument would not contain any moving parts and its mode of operation would not entail scanning over of its field of view. Typically, the instrument would be used to locate a target at a distance on the order of meters to kilometers. The instrument would be best suited for use in an uncluttered setting in which the target is the only or, at worst, the closest object in the vicinity; for example, it could be used aboard an aircraft to detect and track another aircraft flying nearby. The proposed instrument would include a conventional time-of-flight or echo-phase-shift laser range finder, but unlike most other range finders, this one would not generate a narrow cylindrical laser beam; instead, it would generate a conical laser beam spanning the field of view. The instrument would also include a quadrant detector, optics to focus the light returning from the target onto the quadrant detector, and circuitry to synchronize the acquisition of the quadrant-detector output with the arrival of laser light returning from the nearest target. A quadrant detector constantly gathers information from the entire field of view, without scanning; its output is a direct measure of the position of the target-return light spot on the focal plane and is thus a measure of the direction to the target. The instrument should be able to operate at a repetition rate high enough to enable it to track a rapidly moving target. Of course, a target that is not sufficiently reflective could not be located by this instrument. Preferably, retroreflectors should be attached to the target to make it sufficiently reflective.

Bryan, Thomas C.↗

First Search for Dark Sector e+e- Explanations of the MiniBooNE Anomaly at MicroBooNE

The MiniBooNE anomaly has puzzled the neutrino physics community for over two decades. MicroBooNE has previously searched for anomalous electron and photon excesses as potential explanations but the mystery persists. In this poster, we present the first direct test of dark sector models in which dark neutrinos scatter, then decay into e+e− pairs and missing energy, mimicking the MiniBooNE signal. These models have recently emerged as compelling candidates that evade existing constraints. Using 6.87×1020 protons-on-target in the Booster Neutrino Beam, we select forward-going, coherently produced e+e− events in the MicroBooNE detector. We observe 95 events against a constrained background prediction of 69.7±17.3. We set the world's first direct limits on this class of dark sector models, excluding at 95% CL the majority of parameter space viable as a solution to the MiniBooNE anomaly.

Basque, Vincent Marc [Edinburgh U.] (ORCID:0000000↗

Design and simulation of a muon detector to characterize geological overburden

This study presents the design, construction, and simulation of a mobile muon detector tailored for geological overburden characterization. The detector employs plastic scintillator paddles with silicon photomultipliers (SiPMs) and a QuarkNet data acquisition system, offering a portable solution suitable for remote field deployment. The simulator’s modular aluminum frame allows for adjustable geometry and directional sensitivity, while its battery system supports over a week of autonomous operation. Preliminary experimental tests confirmed that its muon flux measurements were consistent with theoretical expectations. A comprehensive simulation framework using Geant4 and CORSIKA was developed to model detector response and overburden effects. Analytical and Monte Carlo methods were used to assess quadrant resolution and infer muon directionality. This work lays the foundation for future overburden mapping and supports the development of reconstruction algorithms for geological applications.

72 - PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of MODIS Solar Diffuser On-orbit Degradation

MODIS reflective solar bands (RSB) are calibrated on-orbit by a solar diffuser (SD) and a solar diffuser stability monitor (SDSM). The SD bi-directional reflectance factor (BRF) was characterized pre-launch by the instrument vendor using reference samples traceable to NIST reflectance standards. Its on-orbit degradation is regularly monitored by the SDSM. It consists of a solar integration sphere (SIS) with 9 filtered detectors with wavelengths ranging from 0.41 to 0.94 micrometer, a rotating mirror assembly, and an electronics module. During each SD/SDSM calibration, the SDSM views the sunlight directly and the sunlight diffusely reflected from the SD panel. The time series of SDSM measurements (ratio of the SD view response to the Sun view response) is used to compute the SD BRF degradation at each SDSM detector wavelength. Since launch Terra MODIS has operated for more than seven years and Aqua for nearly five years. The SD panel on each MODIS instrument has experienced noticeable degradation with the largest changes observed in the VIS spectral region. Following a brief description of the MODIS RSB calibration methodology and SD/SDSM operational activities, this paper illustrates the SD on-orbit degradation results for both Terra and Aqua MODIS. It discusses the impacts on the SD RF degradation due to sensor operational conditions and SD solar exposure time. For Aqua MODIS, operated under the same conditions, the SD annual degradation rate is approximately 2.9% at 0.41 micrometers, 1.6% at 0.47 micrometers, and less than 1.1% at wavelengths above 0.53 micrometers. For Terra MODIS, however, an SD door (SDD) related anomaly in May 2003 had led to a decision to keep the SDD permanently at its open position. Since then its SD has experienced a much faster SD degradation rate.

Xiong, X.↗

Nonequilibrium dynamics of two-level systems directly after cryogenic alternating bias

Two-level systems (TLSs) are a dominant decoherence mechanism in superconducting qubits, microwave kinetic inductance detectors, and quantum dots. TLSs are tunneling states commonly found in amorphous materials and interfaces, which interact electromechanically, leading to energy loss. Fluctuations in the frequency of the TLSs are a significant problem for qubit operation and force recalibration every few hours. In this study, we probe the effect of alternating bias at cryogenic temperatures on TLSs in a purpose-built LC oscillator. When an in situ alternating bias is applied, the steady-state spectra of the TLSs disappear. Spectroscopy reveals transient behavior, in which the TLS frequency fluctuates on the order of minutes. Thermal cycling above 10 K reverses these effects, restoring the TLS spectrum to its original state. Importantly, the intrinsic loss tangent of the LC oscillator remains unchanged before and after the application of the alternating bias. We propose that the disappearance of the steady-state spectrum is caused by nonequilibrium energy buildup from strain in the oxide film introduced by the pulsed voltage-bias sequence. Understanding this nonequilibrium energy could shed light on TLS fluctuations and reduce the calibration requirements for qubits.

general physics↗

Evaluation of simulated HPGe detector efficiencies in OpenMC compared to MCNP

In late 2023, the open-source radiation transport code OpenMC introduced a pulse-height tally (PHT) feature, enabling users to track the total energy deposited by individual photons in OpenMC cells. This function represents an important improvement of the OpenMC code because it allows users to simulate the response function of a gamma detector without relying on closed-source alternatives. Despite this, limited work has been published evaluating OpenMC as a radiation transport code for simulating gamma spectroscopy experiments. This study attempts to demonstrate the usefulness of OpenMC in this space by directly comparing its PHT output to MCNP (a trusted industry-standard Monte Carlo code). In the first half of this study, a radiation transport experiment is described in which a detector with a complex internal geometry is exposed to various gamma-emitting isotopes ( 133 Ba, 137 Cs, and 60 Co) over a range of distances. The setup of this experiment was modeled in MCNP with sufficient detail to capture the efficiency characteristics of a high purity germanium (HPGe) detector for the primary gammas of each isotope. After good agreement between the MCNP model and experiment was achieved, an identical model was produced in OpenMC to allow direct comparison between the full energy peak (FEP) values produced in OpenMC and MCNP. The results show strong agreement between OpenMC and MCNP across the full range of tested energies, with each model’s FEP values typically within 2% of each other and most FEP areas within 4% of experimental data. Worse agreement was seen between the Monte Carlo codes and experiment below 300 keV (an expected result). For the 662 keV line of 137 Cs, both codes were found in poor agreement with experiment and each other over the full range of distances tested (possibly indicating an error with the 137 Cs experimental data). Ignoring the anomalous results of the 662 keV line, all other data show good qualitative and quantitative agreement between MCNP and OpenMC. This result demonstrates the accuracy of OpenMC’s PHT feature for spectroscopic applications in which detector efficiency is a primary concern.

07 - ISOTOPES AND RADIATION SOURCES↗

Unusually Strong Near‐Infrared Photoluminescence of Highly Transparent Bulk InSe Flakes

Abstract Bulk γ‐InSe has a direct bandgap of 1.24 eV, which corresponds to near infrared wavelengths ( λ = 1.0 µm) useful in optoelectronic applications from biometric detectors to silicon photonics. However, its potential for optoelectronic applications is largely untapped due in part to the lack of quantitative studies of its optical properties. Here, the unusually low absorptance and high photoluminescence quantum efficiency of single‐crystalline InSe flakes with thickness in the hundreds of nanometers are studied. InSe emits brightly at room temperature from its direct bandgap with a peak photoluminescence quantum yield (PLQY) of 20%, despite displaying indirect bandgap like low absorption coefficient due to the symmetry of its crystal structure. By performing pump‐dependent PLQY measurements, the radiative and nonradiative recombination coefficients are extracted, including the Shockley‐Read‐Hall and Auger coefficients. Finally, a proof‐of‐concept alternating current electroluminescent device at low temperature is demonstrated to show the promise of InSe in optoelectronic technology such as highly transparent, bright NIR light sources.

Geng, Jamie↗

Demonstration of event position reconstruction based on diffusion in the NEXT-white detector

Noble element time projection chambers are a leading technology for rare event detection in physics, such as for dark matter and neutrinoless double beta decay searches. Time projection chambers typically assign event position in the drift direction using the relative timing of prompt scintillation and delayed charge collection signals, allowing for reconstruction of an absolute position in the drift direction. In this paper, alternate methods for assigning event drift dis tance via quantification of electron diffusion in a pure high pressure xenon gas time projection chamber are explored. Data from the NEXT-White detector demonstrate the ability to achieve good position assignment accuracy for both high and low-energy events. Using point-like energy deposits from 83m Kr calibration electron captures (E ~ 45 keV), the position of origin of low-energy events is determined to 2 cm precision with bias < 1 mm. A convolutional neural network approach is then used to quantify diffusion for longer tracks (E ≥ 1.5 MeV), from radiogenic electrons, yielding a precision of 3 cm on the event barycenter. The precision achieved with these methods indicates the feasibility energy calibrations of better than 1% FWHM at Q ββ in pure xenon, as well as the potential for event fiducialization in large future detectors using an alternate method that does not rely on primary scintillation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charged-particle production as a function of the relative transverse activity classifier in pp, p–Pb, and Pb–Pb collisions at the LHC

Measurements of charged-particle production in pp, p–Pb, and Pb–Pb collisions in the toward, away, and transverse regions with the ALICE detector are discussed. These regions are defined event-by-event relative to the azimuthal direction of the charged trigger particle, which is the reconstructed particle with the largest transverse momentum $(p^{trig}_T)$ in the range 8 < $p^{trig}_T$< 15 GeV/c. The toward and away regions contain the primary and recoil jets, respectively; both regions are accompanied by the underlying event (UE). In contrast, the transverse region perpendicular to the direction of the trigger particle is dominated by the so-called UE dynamics, and includes also contributions from initial- and final-state radiation. The relative transverse activity classifier, $R_T = N^T_{ch}/\langle N^T_{ch}\rangle$, is used to group events according to their UE activity, where $N^T_{ch}$ is the charged-particle multiplicity per event in the transverse region and $\langle N^T_{ch}\rangle$ is the mean value over the whole analysed sample. The energy dependence of the R T distributions in pp collisions at $\sqrt{s_{NN}}$ = 2.76, 5.02, 7, and 13 TeV is reported, exploring the Koba-Nielsen-Olesen (KNO) scaling properties of the multiplicity distributions. The first measurements of charged-particle p T spectra as a function of R T in the three azimuthal regions in pp, p–Pb, and Pb–Pb collisions at $\sqrt{s_{NN}}$ = 5.02 TeV are also reported. Data are compared with predictions obtained from the event generators PYTHIA 8 and EPOS LHC. This set of measurements is expected to contribute to the understanding of the origin of collective-like effects in small collision systems (pp and p–Pb).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Calorimetric classification of track-like signatures in liquid argon TPCs using MicroBooNE data

The MicroBooNE liquid argon time projection chamber located at Fermilab is a neutrino experiment dedicated to the study of short-baseline oscillations, the measurements of neutrino cross sections in liquid argon, and to the research and development of this novel detector technology. Accurate and precise measurements of calorimetry are essential to the event reconstruction and are achieved by leveraging the TPC to measure deposited energy per unit length along the particle trajectory, with mm resolution. We describe the non-uniform calorimetric reconstruction performance in the detector, showing dependence on the angle of the particle trajectory. Such non-uniform reconstruction directly affects the performance of the particle identification algorithms which infer particle type from calorimetric measurements. This work presents a new particle identification method which accounts for and effectively addresses such non-uniformity. The newly developed method shows improved performance compared to previous algorithms, illustrated by a 93.7% proton selection efficiency and a 10% muon mis-identification rate, with a fairly loose selection of tracks performed on beam data. The performance is further demonstrated by identifying exclusive final states in ν μ CC interactions. While developed using MicroBooNE data and simulation, this method is easily applicable to future LArTPC experiments, such as SBND, ICARUS, and DUNE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Visual light flash phenomenon, part C

The Apollo 16 mission provided the opportunity to obtain additional data on the characteristics and frequency of the light flashes and also provided the first opportunity to obtain a direct physical record of incident cosmic ray particles with the Apollo light flash moving emulsion detector (ALFMED). The ALFMED is an electromechanical device that is worn on the head like a helmet and supports cosmic radiation-sensitive emulsions around the head of the test subject. Two light flash observation sessions were conducted during the mission: one during translunar coast and the second during transearth coast. Characteristics of the light flashes observed and reported by the Apollo crew members were generally similar to those reported on previous missions. Analyses of the ALFMED emulsion plates are proceeding as scheduled, although results are not yet available. The ALFMED results should provide conclusive evidence establishing the correlation, if any, between the incident cosmic ray particles and the perception of light flashes as reported by Apollo crew members.

Richard E. Benson↗

Multiwire proportional chamber development

The development of large area multiwire proportional chambers, to be used as high resolution spatial detectors in cosmic ray experiments is described. A readout system was developed which uses a directly coupled, lumped element delay-line whose characteristics are independent of the MWPC design. A complete analysis of the delay-line and the readout electronic system shows that a spatial resolution of about 0.1 mm can be reached with the MWPC operating in the strictly proportional region. This was confirmed by measurements with a small MWPC and Fe-55 X-rays. A simplified analysis was carried out to estimate the theoretical limit of spatial resolution due to delta-rays, spread of the discharge along the anode wire, and inclined trajectories. To calculate the gas gain of MWPC's of different geometrical configurations a method was developed which is based on the knowledge of the first Townsend coefficient of the chamber gas.

Doolittle, R. F.↗