Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diffraction pattern”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Effects of Kapton Sample Cell Windows on the Detection Limit of Smectite: Implications for CheMin on the Mars Science Laboratory Mission

The CheMin instrument on the Mars Science Laboratory (MSL) rover Curiosity is an X-ray diffraction (XRD) and X-ray fluorescence (XRF) instrument capable of providing the mineralogical and chemical compositions of rocks and soils on the surface of Mars. CheMin uses a microfocus X-ray tube with a Co target, transmission geometry, and an energy-discriminating X-ray sensitive CCD to produce simultaneous 2-D XRD patterns and energy-dispersive X-ray histograms from powdered samples. CheMin has two different window materials used for sample cells -- Mylar and Kapton. Instrument details are provided elsewhere. Fe/Mg-smectite (e.g., nontronite) has been identified in Gale Crater, the MSL future landing site, by CRISM spectra. While large quantities of phyllosilicate minerals will be easily detected by CheMin, it is important to establish detection limits of such phases to understand capabilities and limitations of the instrument. A previous study indicated that the (001) peak of smectite at 15 Ang was detectable in a mixture of 1 wt.% smectite with olivine when Mylar is the window material for the sample cell. Complications arise when Kapton is the window material because Kapton itself also has a diffraction peak near 15 Ang (6.8 deg 2 Theta). This study presents results of mineral mixtures of smectite and olivine to determine smectite detection limits for Kapton sample cells. Because the intensity and position of the smectite (001) peak depends on the hydration state, we also analyzed mixtures with "hydrated" and "dehydrated"h smectite to examine the effects of hydration state on detection limits.

Achilles, C. N.↗

Microfracture-pore structure characterization and water-rock interaction in three lithofacies of the Lower Eagle Ford Formation

The microfracture-pore structures and water-rock interactions of eight samples of three typical lithofacies (three limestone, three wackestone, and two mudstone) from the Lower Eagle Ford Formation have been investigated using an integrated methodology. The methods used were X-ray diffraction (XRD), total organic carbon (TOC) content, pyrolysis, thin-section petrography, scanning electron microscopy (SEM), mercury intrusion porosimetry (MIP), spontaneous water imbibition, and water vapor & nitrogen physisorption. Petrophysical properties such as organic richness, maturity, mineral composition, types and patterns of microfractures and pores, porosity, pore-throat size distribution, pore size distribution, pore connectivity, water adsorption and desorption behavior were determined from these methods, and the results compared among the three lithofacies. For example, the three limestone EAS samples and three wackestone DM samples show a low porosity range from 2.02–3.35%, whereas the two mudstone VRU samples exhibit a much large average porosity of 11.7% by MIP results. Nitrogen physisorption results show that pore size distributions have a good similarity in N2 adsorption volume for the samples with similar lithology. Microfractures are morphologically divided into seven types, with their definitions & pictorial examples presented and possible formation mechanisms proposed. In addition, the water vapor physisorption behavior and their controlling factors are discussed. Here, the water adsorption capacity shows a positive relationship (R 2 = 0.90) with clay content and a negative relationship (R 2 = 0.99) with carbonate content. In general, this integrated study of microfracture-pore structure characterization and water-rock interaction provides some insights of water vapor adsorption behavior in different lithofacies and whether microfractures could be an important pathway for fluid flow.

58 GEOSCIENCES↗

Controllable Planar Optical Focusing System

An optical device has a first metasurface disposed over a substrate. A high-contrast pattern of the first metasurface is operable for modifying, over a first phase profile, a phase front of an incident light beam. A second metasurface, is disposed over a plane parallel to the first metasurface with a second high-contrast pattern and operable for shaping, over a second phase profile, the modified phase front of the incident light beam into a converging spherical phase front. A spacer layer, in which the modified phase front of the incident light beam diffracts, is disposed in a controllably changeable separation between the first and second metasurfaces. Controllably changing the separation between the first and the second metasurfaces by a first distance correspondingly changes the position of the focus point of the converging spherical phase front by a second distance significantly greater than the first distance.

Arbabi, Amir↗

Controllable Planar Optical Focusing System

An optical device has a first metasurface. A high-contrast pattern of the first metasurface is operable for modifying, over a first phase profile, a phase front of an incident light beam. A second metasurface, is disposed over a plane parallel to the first metasurface with a second high-contrast pattern and operable for shaping, over a second phase profile, the modified phase front of the incident light beam into a converging spherical phase front. A spacer layer, in which the modified phase front of the incident light beam diffracts, is disposed in a controllably changeable separation between the first and second metasurfaces. Controllably changing the separation between the first and the second metasurfaces by a first distance correspondingly changes the position of the focus point of the converging spherical phase front by a second distance.

Arbabi, Amir↗

OLEDs on planarized light outcoupling-enhancing structures in plastic

Light extraction from OLEDs remains a challenge. While consumer demand for OLEDs in display technology continues to grow as prices decline, commercial use of OLEDs in solid state lighting (SSL) applications is lagging due to low light extraction, which results in low efficiency. Previous studies have been directed toward increasing the light extraction factor η out , but cost effective approaches that will enable high throughput and potential upscaling, as well as elucidation of the extraction process, are still lagging. One promising approach is the use of buried light extraction enhancing patterns that are planarized with a high refractive index (RI) layer. When adding substrate mode extracting means, the highest external quantum efficiencies (EQEs) were achieved using a complex approach of planarized vacuum nano holes. Here we present η out -enhancing planarized extraction structures (PES) in plastic. While plastic substrates currently present long-term stability issues and other drawbacks, as we show, they provide a tool for simple, inexpensive, and rapid generation of various enhancing structures that importantly can be transferred to the preferred rigid and flexible glass substrates. Moreover, plastic substrates are attractive for biomedical applications. The successful structures we present are easily scalable periodic corrugations, e.g., with pitch a ~ 4.25 µm and pitch/depth ratio a/h ~2.4 planarized by a layer of RI ~1.9, resulting in maximal EQEs exceeding 60% for a green OLED and 48.5% for a white OLED. Comparable increased EQEs were achieved for structures with a ~ 15 and 16 µm, and a/h ~ 2.1 and 4, respectively. Enhanced extraction was also observed with a very simply fabricated quasiperiodic nanohole array, and surprisingly, with a random shallow design. The latter is at variance with simulations based on diffraction only. Results are discussed in terms of a, h, and structural parameters together with scattering matrix simulations to assess the effect of various PES parameters and the nanoparticle-embedded planarizing layer on η out . The experiments and simulations indicate contributions of diffraction, reflection, and scattering to EQE enhancement.

36 MATERIALS SCIENCE↗

Fabrication of Fiber Optic Grating Apparatus and Method

An apparatus and method for forming a Bragg grating on an optical fiber using a phase mask to diffract a beam of coherent energy and a lens combined with a pair of mirrors to produce two symmetrical virtual point sources of coherent energy in the plane of the optical fiber. The two virtual light sources produce an interference pattern along the optical fiber. In a further embodiment, the period of the pattern and therefore the Bragg wavelength grating applied to the fiber is varied with the position of the optical fiber relative the lens.

Ying Wang↗

Cytometer on a Chip

A cytometer now under development exploits spatial sorting of sampled cells on a microarray chip followed by use of grating-coupled surface-plasmon-resonance imaging (GCSPRI) to detect the sorted cells. This cytometer on a chip is a prototype of contemplated future miniature cytometers that would be suitable for rapidly identifying pathogens and other cells of interest in both field and laboratory applications and that would be attractive as alternatives to conventional flow cytometers. The basic principle of operation of a conventional flow cytometer requires fluorescent labeling of sampled cells, stringent optical alignment of a laser beam with a narrow orifice, and flow of the cells through the orifice, which is subject to clogging. In contrast, the principle of operation of the present cytometer on a chip does not require fluorescent labeling of cells, stringent optical alignment, or flow through a narrow orifice. The basic principle of operation of the cytometer on a chip also reduces the complexity, mass, and power of the associated laser and detection systems, relative to those needed in conventional flow cytometry. Instead of making cells flow in single file through a narrow flow orifice for sequential interrogation as in conventional flow cytometry, a liquid containing suspended sampled cells is made to flow over the front surface of a microarray chip on which there are many capture spots. Each capture spot is coated with a thin (.50-nm) layer of gold that is, in turn, coated with antibodies that bind to cell-surface molecules characteristic of the cell species of interest. The multiplicity of capture spots makes it possible to perform rapid, massively parallel analysis of a large cell population. The binding of cells to each capture spot gives rise to a minute change in the index of refraction at the surface of the chip. This change in the index of refraction is what is sensed in GCSPRI, as described briefly below. The identities of the various species in a sample of cells is spatially encoded in the chip by the pattern of capture spots. The number of cells of a particular species is determined from the magnitude of the GCSPRI signal from that spot. GCSPRI as used here can be summarized as follows: The cytometer chip is fabricated with a diffraction grating on its front surface. The chip is illuminated with a light emitting diode (LED) from the front. By proper choice of grating parameters and of the wavelength and the angle of incidence of a laser beam, laser light can be made to be coupled into an electromagnetic mode that resonates with surface plasmons and thus couples light into surface plasmons. Coupling of light into a surface plasmon at a given location reduces the amount of incident light reflected from that location. A change in the index of refraction at the surface of a capture spot gives rise to a change in the resonance condition. Depending on the specific design, the change in the index of refraction could manifest itself as a brightening or darkening, a change in the wavelength needed to excite the plasmon at a given angle of incidence, or a change in the angle of incidence needed to excite the plasmon at a given wavelength. Whereas a multiwavelength laser system with multichannel detection would be needed to detect multiple species in conventional flow cytometry, it suffices to use an LED and a single detector channel in the GCSPRI approach: this contributes significantly to reductions in cost, complexity, size, mass, and power. GCSPRI cytometer chips could be made of plastic and could be mass-produced cheaply by use of molding and other methods adopted from the manufacture of digital video disks. These methods are amenable to a high degree of miniaturization: such additional features as fluidic channels, reaction chambers, and fluid-coupling ports could readily be incorporated into the chips, without incurring substantial additional costs.

Fernandez, Salvador M.↗

Cytometer on a Chip

A cytometer now under development exploits spatial sorting of sampled cells on a microarray chip followed by use of grating-coupled surface-plasmon-resonance imaging (GCSPRI) to detect the sorted cells. This cytometer on a chip is a prototype of contemplated future miniature cytometers that would be suitable for rapidly identifying pathogens and other cells of interest in both field and laboratory applications and that would be attractive as alternatives to conventional flow cytometers. The basic principle of operation of a conventional flow cytometer requires fluorescent labeling of sampled cells, stringent optical alignment of a laser beam with a narrow orifice, and flow of the cells through the orifice, which is subject to clogging. In contrast, the principle of operation of the present cytometer on a chip does not require fluorescent labeling of cells, stringent optical alignment, or flow through a narrow orifice. The basic principle of operation of the cytometer on a chip also reduces the complexity, mass, and power of the associated laser and detection systems, relative to those needed in conventional flow cytometry. Instead of making cells flow in single file through a narrow flow orifice for sequential interrogation as in conventional flow cytometry, a liquid containing suspended sampled cells is made to flow over the front surface of a microarray chip on which there are many capture spots. Each capture spot is coated with a thin (approximately 50-nm) layer of gold that is, in turn, coated with antibodies that bind to cell-surface molecules characteristic of one the cell species of interest. The multiplicity of capture spots makes it possible to perform rapid, massively parallel analysis of a large cell population. The binding of cells to each capture spot gives rise to a minute change in the index of refraction at the surface of the chip. This change in the index of refraction is what is sensed in GCSPRI, as described briefly below. The identities of the various species in a sample of cells is spatially encoded in the chip by the pattern of capture spots. The number of cells of a particular species is determined from the magnitude of the GCSPRI signal from that spot. GCSPRI as used here can be summarized as follows: The cytometer chip is fabricated with a diffraction grating on its front surface. The chip is illuminated with a light emitting diode (LED) from the front. By proper choice of grating parameters and of the wavelength and the angle of incidence of a laser beam, laser light can be made to be coupled into an electromagnetic mode that resonates with surface plasmons and thus couples light into surface plasmons. Coupling of light into a surface plasmon at a given location reduces the amount of incident light reflected from that location. A change in the index of refraction at the surface of a capture spot gives rise to a change in the resonance condition. Depending on the specific design, the change in the index of refraction could manifest itself as a brightening or darkening, a change in the wavelength needed to excite the plasmon at a given angle of incidence, or a change in the angle of incidence needed to excite the plasmon at a given wavelength. Whereas a multiwavelength laser system with multichannel detection would be needed to detect multiple species in conventional flow cytometry, it suffices to use an LED and a single detector channel in the GCSPRI approach: this contributes significantly to reductions in cost, complexity, size, mass, and power. GCSPRI cytometer chips could be made of plastic and could be mass-produced cheaply by use of molding and other methods adopted from the manufacture of digital video disks. These methods are amenable to a high degree of miniaturization: such additional features as fluidic channels, reaction chambers, and fluid-coupling ports could readily be incorporated into the chips, without incurring substantial additional costs.

Fernandez, Salvador M.↗

Effects of deposition and annealing conditions on the crystallisation of NiTi thin films by e-beam evaporation

This Letter demonstrates the effects of deposition and annealing conditions on the crystallisation of nickel–titanium (NiTi) thin films deposited by the e-beam evaporation. NiTi thin films of 0.5 μm thick are fabricated on P-type (110) silicon substrates using the e-beam evaporation technique. We find that with the characterisations using the X-ray diffraction method, the results indicate that low e-beam deposition rate and argon employed annealing procedures can be beneficial to the formation of NiTi crystalline structure. Additionally, the as-deposited NiTi thin films without annealing procedures are amorphous, when deposited on the substrates at low temperatures. The differential scanning calorimetry studies show NiTi thin films formed by the e-beam evaporation are Ni-rich. Furthermore, SEM images illustrate that high-precision patterned NiTi thin film microstructures can be fabricated by combining with the e-beam evaporation and lift-off resist methods, without any wet or dry etching procedures. The proposed fabrication process for NiTi thin film microstructures shows great potential for application in shape memory alloy medical devices, as well as the micro-robotics.

36 MATERIALS SCIENCE↗

Automated classification of big X-ray diffraction data using deep learning models

Abstract In current in situ X-ray diffraction (XRD) techniques, data generation surpasses human analytical capabilities, potentially leading to the loss of insights. Automated techniques require human intervention, and lack the performance and adaptability required for material exploration. Given the critical need for high-throughput automated XRD pattern analysis, we present a generalized deep learning model to classify a diverse set of materials’ crystal systems and space groups. In our approach, we generate training data with a holistic representation of patterns that emerge from varying experimental conditions and crystal properties. We also employ an expedited learning technique to refine our model’s expertise to experimental conditions. In addition, we optimize model architecture to elicit classification based on Bragg’s Law and use evaluation data to interpret our model’s decision-making. We evaluate our models using experimental data, materials unseen in training, and altered cubic crystals, where we observe state-of-the-art performance and even greater advances in space group classification.

Chemistry↗

In situ measurement and modelling of the growth and length scale of twins in α -uranium

Twinning is an important deformation mechanism in crystalline materials. Twins nucleate, then grow, forming a discrete pattern of deformation bands with a certain thickness. The mechanism for twin growth is not completely understood. We present a simple phase field model which captures the physics of twin growth and reproduces the details observed during in situ electron backscatter diffraction experiments on α-uranium. The interaction between residual dislocations at twin interfaces and mobile dislocations in untwinned regions increases the stress needed for twin growth. This is described by a nonlocal term in the proposed constitutive equations: the nucleation stress of a twin increases proportionally to the twin phase field in a neighborhood. Competition between slip and twinning favors the nucleation of a new twin rather than the growth of a preexisting twin. The phase field model is coupled with a crystal plasticity finite element solver that includes the plastic deformation due to twinning. Simulations are able to reproduce the number of twins and their thicknesses as a function of the strain observed during in situ electron backscatter diffraction experiments. The stress-strain curve is also reproduced. This comparison allows the values of the nucleation stress and the interaction strength between residual and mobile dislocations to be found. It also gives an estimation of the density of residual dislocations that is consistent with the observed twin thickness. Finally, this model can be applied to understand microstructural effects in materials using twinning as a strengthening mechanism.

36 MATERIALS SCIENCE↗

Nanometer-scale structure differences in the myofilament lattice spacing of two cockroach leg muscles correspond to their different functions

ABSTRACT Muscle is highly organized across multiple length scales. Consequently, small changes in the arrangement of myofilaments can influence macroscopic mechanical function. Two leg muscles of a cockroach have identical innervation, mass, twitch responses, length–tension curves and force–velocity relationships. However, during running, one muscle is dissipative (a ‘brake’), while the other dissipates and produces significant positive mechanical work (bifunctional). Using time-resolved X-ray diffraction in intact, contracting muscle, we simultaneously measured the myofilament lattice spacing, packing structure and macroscopic force production of these muscles to test whether structural differences in the myofilament lattice might correspond to the muscles' different mechanical functions. While the packing patterns are the same, one muscle has 1 nm smaller lattice spacing at rest. Under isometric stimulation, the difference in lattice spacing disappeared, consistent with the two muscles' identical steady-state behavior. During periodic contractions, one muscle undergoes a 1 nm greater change in lattice spacing, which correlates with force. This is the first identified structural feature in the myofilament lattice of these two muscles that shares their whole-muscle dynamic differences and quasi-static similarities.

Tune, Travis Carver↗

Ionization-Based Optical Structures for the Control of Short-Pulse Lasers (Full LDRD Report)

High-power lasers require enormous beam sizes to avoid optics damage; without plasma control of light, future higher-power systems will have prohibitive costs. The laser-induced formation of ionization patterns in gases provides an opportunity to manipulate the spatial and temporal properties of femtosecond to picosecond beams with precise control at high intensity, providing a path towards compact multi-petawatt lasers. In this project, we proposed new concepts of diffractive optics elements relying on ionization-based structures, including a holographic lens and a compression grating. The theoretical characterization of these optical elements was supported by particle-in-cell simulations. Experiments have been carried out to achieve reflective elements (i.e., plasma-based gratings) that demonstrated high robustness and efficiencies on the order of 50%, which validates the feasibility of our new concepts and paves the way for future plasma-based high-power laser systems.

47 OTHER INSTRUMENTATION↗

Asynchronous domain dynamics and equilibration in layered oxide battery cathode

To improve lithium-ion battery technology, it is essential to probe and comprehend the microscopic dynamic processes that occur in a real-world composite electrode under operating conditions. The primary and secondary particles are the structural building blocks of battery cathode electrodes. Their dynamic inconsistency has profound but not well-understood impacts. In this research, we combine operando coherent multi-crystal diffraction and optical microscopy to examine the chemical dynamics in local domains of layered oxide cathode. Our results not only pinpoint the asynchronicity of the lithium (de)intercalation at the sub-particle level, but also reveal sophisticated diffusion kinetics and reaction patterns, involving various localized processes, e.g., chemical onset, reaction front propagation, domains equilibration, particle deformation and motion. These observations shed new lights onto the activation and degradation mechanisms of state-of-the-art battery cathode materials.

25 ENERGY STORAGE↗

Spin canting and lattice symmetry in La 2 CuO 4

While the dominant magnetic interaction in La 2 CuO 4 is superexchange between nearest-neighbor Cu moments, the pinning of the spin direction depends on weak anisotropic effects associated with spin-orbit coupling. The symmetry of the octahedral tilt pattern allows an out-of-plane canting of the Cu spins, which is compensated by an opposite canting in nearest-neighbor layers. A strong magnetic field applied perpendicular to the planes can alter the spin canting pattern to induce a weak ferromagnetic phase. In light of recent evidence that the lattice symmetry is lower than originally assumed, we take another look at the nature of the field-induced spin-rotation transition. Comparing low-temperature neutron diffraction intensities for several magnetic Bragg peaks measured in fields of 0 and 14 T, we find that a better fit is provided by a model in which spins rotate within both neighboring planes but by different amounts, resulting in a noncollinear configuration. Finally, this model allows a more consistent relationship between lattice symmetry and spin orientation at all Cu sites.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Chirality in the Kagome Metal CsV 3 ⁢Sb 5

Using x-ray photoelectron diffraction (XPD) and angle-resolved photoemission spectroscopy, we study photoemission intensity changes related to changes in the geometric and electronic structure in the kagome metal CsV 3 ⁢Sb 5 upon transition to an unconventional charge density wave (CDW) state. The XPD patterns reveal the presence of a chiral atomic structure in the CDW phase. Furthermore, using circularly polarized x-rays, we have found a pronounced nontrivial circular dichroism in the angular distribution of the valence band photoemission in the CDW phase, indicating a chirality of the electronic structure. This observation is consistent with the proposed orbital loop current order. In view of a negligible spontaneous Kerr signal in recent magneto-optical studies, the results suggest an antiferromagnetic coupling of the orbital magnetic moments along the 𝑐 axis. Here, while the inherent structural chirality may also induce circular dichroism, the observed asymmetry values seem to be too large in the case of the weak structural distortions caused by the CDW.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-Bandwidth Frequency Selective Surfaces for Near Infrared Filtering: Design and Optimization

Frequency selective surfaces are widely used in the microwave and millimeter wave regions of the spectrum for filtering signals. They are used in telecommunication systems for multi-frequency operation or in instrument detectors for spectroscopy. The frequency selective surface operation depends on a periodic array of elements resonating at prescribed wavelengths producing a filter response. The size of the elements is on the order of half the electrical wavelength, and the array period is typically less than a wavelength for efficient operation. When operating in the optical region, diffraction gratings are used for filtering. In this regime the period of the grating may be several wavelengths producing multiple orders of light in reflection or transmission. In regions between these bands (specifically in the infrared band) frequency selective filters consisting of patterned metal layers fabricated using electron beam lithography are beginning to be developed. The operation is completely analogous to surfaces made in the microwave and millimeter wave region except for the choice of materials used and the fabrication process. In addition, the lithography process allows an arbitrary distribution of patterns corresponding to resonances at various wavelengths to be produced. The design of sub-millimeter filters follows the design methods used in the microwave region. Exacting modal matching, integral equation or finite element methods can be used for design. A major difference though is the introduction of material parameters and thicknesses that may not be important in longer wavelength designs. This paper describes the design of multi- bandwidth filters operating in the 1-5 micrometer wavelength range. This work follows on a previous design. In this paper extensions based on further optimization and an examination of the specific shape of the element in the periodic cell will be reported. Results from the design, manufacture and test of linear wedge filters built using microlithographic techniques and used in spectral imaging applications will be presented.

Cwik, Tom↗

Multi-Bandwidth Frequency Selective Surfaces for Near Infrared Filtering: Design and Optimization

Frequency selective surfaces are widely used in the microwave and millimeter wave regions of the spectrum for filtering signals. They are used in telecommunication systems for multi-frequency operation or in instrument detectors for spectroscopy. The frequency selective surface operation depends on a periodic array of elements resonating at prescribed wavelengths producing a filter response. The size of the elements is on the order of half the electrical wavelength, and the array period is typically less than a wavelength for efficient operation. When operating in the optical region, diffraction gratings are used for filtering. In this regime the period of the grating may be several wavelengths producing multiple orders of light in reflection or transmission. In regions between these bands (specifically in the infrared band) frequency selective filters consisting of patterned metal layers fabricated using electron beam lithography are beginning to be developed. The operation is completely analogous to surfaces made in the microwave and millimeter wave region except for the choice of materials used and the fabrication process. In addition, the lithography process allows an arbitrary distribution of patterns corresponding to resonances at various wavelengths to be produced. The design of sub-millimeter filters follows the design methods used in the microwave region. Exacting modal matching, integral equation or finite element methods can be used for design. A major difference though is the introduction of material parameters and thicknesses tha_ may not be important in longer wavelength designs. This paper describes the design of multi-bandwidth filters operating in the I-5 micrometer wavelength range. This work follows on previous design [1,2]. In this paper extensions based on further optimization and an examination of the specific shape of the element in the periodic cell will be reported. Results from the design, manufacture and test of linear wedge filters built using micro-lithographic techniques and used ir spectral imaging applications will be presented.

Cwik, Tom↗