Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dc”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Improved DC Gun Insulator Assembly

Many user fa­cil­i­ties such as syn­chrotron ra­di­a­tion light sources and free elec­tron lasers re­quire ac­cel­er­at­ing struc­tures that sup­port elec­tric fields of 10-100 MV/m, es­pe­cial­ly at the start of the ac­cel­er­a­tor chain where ce­ram­ic in­su­la­tors are used for very high gra­di­ent DC guns. These in­su­la­tors are dif­fi­cult to man­u­fac­ture, re­quire long com­mis­sion­ing times, and often ex­hib­it poor re­li­a­bil­i­ty. Two tech­ni­cal ap­proach­es to solv­ing this prob­lem will be in­ves­ti­gat­ed. First­ly, in­vert­ed ce­ram­ics offer so­lu­tions for re­duced gra­di­ents be­tween the elec­trodes and ground. An in­vert­ed de­sign will be pre­sent­ed for 350 kV, with max­i­mum gra­di­ents in the range of 5-10 MV/m. Sec­ond­ly, novel ce­ram­ic man­u­fac­tur­ing pro­cess­es will be stud­ied, in order to pro­tect triple junc­tion lo­ca­tions from emis­sion, by ap­ply­ing a coat­ing with a bulk re­sis­tiv­i­ty. The pro­cess­es for cre­at­ing this coat­ing will be op­ti­mized to pro­vide pro­tec­tion as well as be used to coat a ce­ram­ic with an ap­pro­pri­ate gra­di­ent in bulk re­sis­tiv­i­ty from the vac­u­um side to the air side of an HV stand­off ce­ram­ic cylin­der. Ex­am­ple in­su­la­tor de­signs are being com­put­er mod­elled, and in­su­la­tor sam­ples are being man­u­fac­tured and test­ed

43 PARTICLE ACCELERATORS↗

Enhanced Bottom Anode Monitoring in DC Electric Arc Furnaces Using Fiber-Optic Sensors

A pin style bottom anode employs conductive steel rods that serve as the pathway for the high electrical power through rammed refractory at the bottom of a DC Electric Arc Furnace (EAF). Anode wear during operation is important to monitor, as anode replacement is expensive and impacts EAF productivity. Liquid steel penetration into the un-sintered refractory layer can result from rapid electrical power ramp-up, dips in furnace temperature, or operating the anode for too long between EAF campaigns. In extreme cases, the liquid steel may penetrate the bottom of the furnace when anode wear progresses too close to the bottom shell, which is extremely dangerous and must be avoided. The current state of the art for monitoring bottom anode wear employs thermocouples imbedded in the anode pins at points in the anode. However, this approach is not sensitive enough to detect localized damage to the anode, especially when cracking occurs. Here, the present work utilizes fiber optic sensors to monitor the health of the anode, by creating a real-time spatially distributed temperature map of the anode. Unlike the traditional thermocouples, these sensors can be mounted at significantly greater depths, provide distributed temperature measurements, and can withstand temperatures of up to 900°C. Additionally, they are able to perform temperature measurements with a spatial resolution of 1.3 mm at a 5 Hz acquisition rate, providing unprecedented high-density real time monitoring of anode health and increasing the efficiency, and safety of EAF operation.

Bottom Anode↗

Impact of Cyber Attacks on High Voltage DC Transmission Damping Control

Electric grids have evolved to being a huge cyberphysical system (CPS) that combines intelligent electronic devices (IEDs), computing resources, communication networks and electricity infrastructures. The wide attack surface and increasing dependence on communication make power systems vulnerable to cyber attacks. This paper studies the impact of cyber attacks on high voltage DC (HVDC) transmission oscillation damping control. Three kinds of cyber attack models are considered: timing attack , replay attack, and false data injection attack. The attacks are applied to the HVDC damping controller, which requires widearea measurements and long-distance communication. A modified IEEE New England 39-Bus AC-HVDC system is used as the test system. Simulation results have shown that all three kinds of attacks are capable of driving the AC-HVDC system into swing or unstable conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wave Energy Power Take-off Validation with a Hydraulicly Actuated Rotary Dynamometer and a Bi-Directional High-Power DC Supply

There are many organizations working towards the commercialization of wave energy converter technologies and are advancing their designs through the technology readiness levels (TRLs). A critical step before the field deployment of prototype wave energy converters is the validation of the subsystems and components that are contained in the wave energy converter through laboratory testing and performance characterization. In 2021, the National Renewable Energy Laboratory (NREL) developed and demonstrated a system for testing power takeoffs (PTO) with a low-speed, high-torque dynamometer and a grid-tied high-power DC power source and sink before field deployment. The hydraulic dynamometer allows for the simulation of PTO actuation from wave motion and is capable of a wide range of wave periods and heights which are represented as various speeds and torques from the dynamometer. The high-power bidirectional power supply allows for hardware in the loop and controller in the loop testing to be conducted on WEC power electronics. This presentation was made to describe the methods used by NREL research staff to test all components and sub-systems in the PTO of a novel wave energy converter before field deployment.

dynamometer↗

Complete genome sequence of Dehalogenimonas lykanthroporepellens type strain (BL-DC-9T) and comparison to Dehalococcoides strains

Dehalogenimonas lykanthroporepellens is the type species of the genus Dehalogenimonas, which belongs to a deeply branching lineage within the phylum Chloroflexi. This strictly anaerobic, mesophilic, non spore forming, Gram negative staining bacterium was first isolated from chlorinated solvent contaminated groundwater at a Superfund site located near Baton Rouge, Louisiana, USA. D. lykanthroporepellens was of interest for genome sequencing for two reasons: (a) its unusual ability to couple growth with reductive dechlorination of environmentally important polychlorinated aliphatic alkanes and (b) its phylogenetic position distant from previously sequenced bacteria. The 1,686,510 bp circular chromosome of strain BL-DC-9{sup T} contains 1,720 predicted protein coding genes, 47 tRNA genes, a single large subunit rRNA (23S-5S) locus, and a single, orphan, small unit rRNA (16S) locus.

54 ENVIRONMENTAL SCIENCES↗

Aerosynthesis: Growths of Vertically Aligned Carbon Nanofibers with Air DC Plasma

Vertically aligned carbon nanofibers (VACNF) have been synthesized in a mixture of acetone and air using catalytic DC plasma enhanced chemical vapor deposition. Typically, ammonia or hydrogen is used as etchant gas in the mixture to remove carbon that otherwise passivates the catalyst surface and impedes growth. Our demonstration of using air as the etchant gas opens up a possibility that ion etching could be sufficient to maintain the catalytic activity state during synthesis. It also demonstrates the path toward growing VACNFs in open atmosphere.

Kodumagulla, A↗

High-pass RF coaxial filter rejects dc and low frequency signals

A low-loss RF filter element for coaxial transmission provides dc isolation and eliminates low frequency signals. The characteristic impedance of the transmission line is not affected, as the design permits direct connection of the filter to the line.

Bailey, J. W.↗

Variable load automatically tests dc power supplies

Continuously variable load automatically tests dc power supplies over an extended current range. External meters monitor current and voltage, and multipliers at the outputs facilitate plotting the power curve of the unit.

Burke, H. C., Jr.↗

Tester periodically registers dc amplifier characteristics

Motor-driven switcher-recorder periodically registers the zero drift and gain drift signals of a dc amplifier subjected to changes in environment. A time coding method is used since several measurements are shared on a single recorder trace.

Cree, D.↗