Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Visualization: A pathway to enhanced scientific productivity in the expanding missions of Space and Earth Sciences

The movement toward the solution of problems involving large-scale system science, the ever-increasing capabilities of three-dimensional, time-dependent numerical models, and the enhanced capabilities of 'in situ' and remote sensing instruments bring a new era of scientific endeavor that requires an important change in our approach to mission planning and the task of data reduction and analysis. Visualization is at the heart of the requirements for a much-needed enhancement in scientific productivity as we face these new challenges. This article draws a perspective on the problem as it crosses discipline boundaries from solar physics to atmospheric and ocean sciences. It also attempts to introduce visualization as a new approach to scientific discovery and a tool which expedites and improves our insight into physically complex problems. A set of simple illustrations demonstrates a number of visualization techniques and the discussion emphasizes the trial-and-error and search-and-discover modes that are necessary for the techniques to reach their full potential. Further discussions also point to the importance of integrating data access, management, mathematical operations, and visualization into a single system. Some of the more recent developments in this area are reviewed.

Szuszczewicz, E. P.↗

Strain buildup and release, earthquake prediction and selection of VLB sites for the margins of the North Pacific

Microearthquake studies of the southern section of the San Andreas fault system were conducted in order to elucidate the role of known but little studied complications in the fault system which could affect the SAFE measurement. Data reduction from microearthquake studies in Baja California, Mexico, was completed. In addition, styles of deformation on the Alpine fault in New Zealand and on the San Andreas fault were compared. Sections of these faults with comparable physical characteristics seem to deform in a similar manner, indicating that deformation style is controlled by certain fundamental relations and will continue in the future. The geology of eastern New Guinea is also discussed. Deformation in the area is proposed to be related to collision of a series of island arcs with central New Guinea, which is part of the Australian continent. Among other unusual properties, eastern New Guinea contains the highest anomaly of the gravimetrically determined geoid based on GEM 6 and surface gravity data.

Scholz, C. H.↗

Analog Techniques for Measuring the Frequency Response of Linear Physical Systems Excited by Frequency-Sweep Inputs

Data-reduction methods using general-purpose analog computer equipment and compatible testing techniques for determining the frequency response of linear physical systems are examined. The techniques considered may be classed as steady state or transient depending on the method of excitation. The relative merits of periodic, slow sweep, and transient (rapid sweep) forcing functions are discussed and applications are given that relate to dynamic-response tests of aeroelastic systems. Two frequency-sweep-input methods are considered in detail. one case the sweep rate is sufficiently slow that the response is approximately the same as that for steady-state conditions. With this input the frequency response can be evaluated and displayed in real time while the test is in progress. Errors due to treating sweep data as steady state can be eliminated, when desired, by reanalyzing tape-recorded time histories of the input and output as transient rather than as periodic data. In the second method the frequency-response function is deter- mined from the system's transient response to a very rapid sweep input. The purpose of frequency sweep in this case is to provide sufficient harmonic content in the input to overcome noise while keeping the test time as short as possible. tests and limited flight-test data presented herein, it appears that a transient-type rapid-sweep forcing function offers a considerable saving in test time while preserving the accuracy possible with steady-state sinusoidal inputs.

Wilmer H. Reed III↗

SO2 on Venus: A final cross-calibration with Pioneer Venus

In the present reporting period we have met with the Pioneer Venus PI to collaborate on the recalibration of the UV spectrometer of Pioneer Venus. The associated data reduction and analysis activities have been completed. The sensitivity of the UV spectrometer has been steadily declining since orbit insertion of Pioneer Venus in 1978 due to aging of the detector tubes. The sensitivity decline is a strong function of wavelength and the rate of decline is also a function of time. Measures were taken to reduce the light dose received by the instrument to slow down the sensitivity decline. The stellar calibration using the bright UV star Hadar in 1990 indicates that the sensitivity decline may have slowed down more than have been previously estimated. The derived amount of SO2 from Pioneer Venus depends on the accuracy of the absolute sensitivity of the UV spectrometer. The previous cross calibration between IUE and Pioneer Venus led to the use of the same solar flux data for reducing and modelling data from both IUE and Pioneer Venus. The comparison between the 1991 IUE results and the Pioneer Venus stellar calibration carried out in 1990 will allow a more accurate determination of sensitivity decline of the PV UV spectrometer. The result of this comparison will be crucial in determining the trend of SO2 in the Venus atmosphere.

Stern, S. Alan↗

Investigation of the external flow analysis for density measurements at high altitude

The results of analysis performed on the external flow around the shuttle orbiter nose regions at the Shuttle Upper Atmosphere Mass Spectrometer (SUMS) inlet orifice are presented. The purpose of the analysis is to quantitatively characterize the flow conditions to facilitate SUMS flight data reduction and subsequent determination of orbiter aerodynamic force coefficients in the hypersonic rarefied flow regime. Experimental determination of aerodynamic force coefficients requires accurate simultaneous measurement of forces (or acceleration) and dynamic pressure along with independent knowledge of density and velocity. The SUMS provides independent measurement of dynamic pressure; however, it does so indirectly and requires knowledge of the relationship between measured orifice conditions and the dynamic pressure which can only be determined on the basis of molecule or theory for a winged configuration. Monte Carlo direct simulation computer codes were developed for both the flow field solution at the orifice and for the internal orifice flow. These codes were used to study issues associated with geometric modeling of the orbiter nose geometry and the modeling of intermolecular collisions including rotational energy exchange and a preliminary analysis of vibrational excitation and dissociation effects. Data obtained from preliminary simulation runs are presented.

Bienkowski, G. K.↗

A long-range laser velocimeter

A long-range laser velocimeter (LV) developed for remote operation from within the flow fields of large wind tunnels is described. Emphasis is placed on recent improvements in optical hardware as well as recent additions to data acquisition and processing techniques. The method used for data reduction of photon resolved signals is outlined in detail, and measurement accuracy is discussed. To study the performance of the LV and verify the measurement accuracy, laboratory measurements were made in the flow field of a 10-cm-diameter, 30-m/s axisymetric jet. The measured velocity and turbulence intensity surveys are compared with measurements made with a hot-wire anemometer. Additionally, the LV was used during the flow calibration of the 80-ft x 120-ft wind tunnel to measure the test-section boundary-layer thickness at the maximum wind tunnel speed of 51.5 m/s. The requirements and techniques used to seed the flow are discussed, and boundary-layer surveys of mean velocity and turbulence intensity of the streamwise component and the component normal to the surface are presented. The streamwise component of mean velocity is compared with data obtained with a total pressure rake.

Reinath, Michael S.↗

Progress in the measurement of SSME turbine heat flux with plug-type sensors

Data reduction was completed for tests of plug-type heat flux sensors (gauges) in a turbine blade thermal cycling tester (TBT) that is located at NASA/Marshall Space Flight Center, and a typical gauge is illustrated. This is the first time that heat flux has been measured in a Space Shuttle Main Engine (SSME) Turbopump Turbine environment. The development of the concept for the gauge was performed in a heat flux measurement facility at Lewis. In this facility, transient and steady state absorbed surface heat flux information was obtained from transient temperature measurements taken at points within the gauge. A schematic of the TBT is presented, and plots of the absorbed surface heat flux measured on the three blades tested in the TBT are presented. High quality heat flux values were measured on all three blades. The experiments demonstrated that reliable and durable gauges can be repeatedly fabricated into the airfoils. The experiment heat flux data are being used for verification of SSME analytical stress, boundary layer, and heat transfer design models. Other experimental results and future plans are also presented.

Liebert, Curt H.↗

Millstone Hill radar: Capabilities for S/T observations

During the past several years, the 440-MHz radar at Millstone Hill has been modified to detect coherent echoes from clear-air turbulence in the stratosphere/troposphere (S/T) over the altitude range 4-25 km. Two distinct modes of data acquisition have been developed, and data reduction programs have been completed for one of these modes. This mode (I-mode) transmits a 10 microsec (1.5 km) pulse on the fully steerable antenna. Typically, the antenna is set at a low elevation angle (e.g., 15 deg.) to reduce the altitude resolution to approximately 1 km., and power spectra are collected at some 40 range gates. The antenna may be scanned in azimuth to obtain the total wind vector, held fixed to monitor wave motion, or scanned in elevation to monitor the horizontal extent of the turbulent activity. This steerability gives Millstone a flexible system to focus on localized events, such as lee waves or convective storms. An additional advantage at low elevations is the relatively large Doppler shift of the signal, since the LOS velocity contains a large component of the horizontal velocity. This shift separates the turbulence signal sufficiently far from the ground clutter to allow the spectral moments to be readily inferred. Some 500 hours of S/T I-mode data have been reduced to geophysical parameters, and reside on a data base at Millstone Hill.

Loriot, G. B.↗

Solar-B X-ray Telescope (XRT) Concept Study Report

The X-ray observations from the Yohkoh SXT provided the greatest step forward in our understanding of the solar corona in nearly two decades. Expanding on the accomplishments of Yohkoh, we believe that the scientific objectives of the Solar-B mission are achieved with a significantly improved X-ray telescope (XRT) similar to the SXT. The Solar-B XRT will have twice the spatial resolution and a broader temperature response, while building on the knowledge gained from the successful Yohkoh mission. We present the scientific justification for this view, discuss the instrumental requirements that flow from the scientific objectives, and describe the instrumentation to meet these requirements. We then provide a detailed discussion of the design activities carried out during Phase A, noting the conclusions that were reached in terms of their implications for the detailed design activities which are now commencing. Details of the instrument that have changed as a result of the Phase A studied are specifically noted, and areas of concern going into Phase B are highlighted. XRT is a grazing-incidence (GI) modified Wolter I X-ray telescope, of 35cm inner diameter and 2.7m focal length. The 2048x2048 back-illuminated CCD (now an ISAS responsibility) has 13.5 micron pixels, corresponding to 1.0 arcsec and giving full Sun field of view. This will be the highest resolution GI X-ray telescope ever flown for Solar coronal studies, and it has been designed specifically to observe both the high and low temperature coronal plasma. A small optical telescope provides visible light images for co-alignment with the Solar-B optical and EUV instruments. The XRT science team is working in close cooperation with our Japanese colleagues in the design and construction of this instrument. All of the expertise and resources of the High Energy and Solar/Stellar Divisions of the Center for Astrophysics are being made available to this program, and our team will carry its full share of responsibility for mission operations, data reduction and education and public outreach. All aspects of the XRT design were reviewed during Phase A. The study focussed particularly on those aspects that have the greatest affect on instrument performance and extended lifetime, on the image quality error budget, and on the camera (mechanical and electrical) interface and the instrument mounting interfaces. The present instrument design differs in some details from that originally proposed. Selection of the XRT for Phase A study was contingent upon the removal of the camera and its associated electronics, and the acceptance of a stringent cost cap. The removal of the electronics left the XRT without control electronics for the instrument mechanisms. A mechanism controller was therefore added. The removal of the camera resulted in major complications to the integration and test plan. After many discussions, it was decided that the system would be less expensive, and the risk of unacceptable performance lower, if we include a focus mechanism. The remainder of the XRT design baseline matches the proposed configuration. Data requirements for the XRT are driven by the science plans, which are based on the physical processes in the solar outer atmosphere. Discussions to date of the XRT observing plan, both alone and in conjunction with the other Solar-B instruments, shows that the XRT needs 2 Gbits of on-board storage, at least one circulating buffer of 640 Mbits, and twelve 10- minute downlinks per day in order to carry out its required programs.

Golub, Leon↗

Characterization of the Edge Crack Torsion (ECT) Test for Mode III Fracture Toughness Measurement of Laminated Composites

The edge crack torsion (ECT) test is designed to initiate mode III delamination growth in composite laminates. An ECT specimen is a rectangular laminate, containing an edge delamination at the laminate mid-plane. Torsion load is applied to the specimens, resulting in relative transverse shear sliding of the delaminated faces. The test data reduction schemes are intended to yield initiation values of critical mode III strain energy release rate, G(sub IIIc), that are constant with delamination length. The test has undergone several design changes during its development. The objective of this paper was to determine the suitability of the current ECT test design as a mode III fracture test. To this end, ECT tests were conducted on specimens manufactured from IM7/8552 and specimens made from S2/8552 tape laminates. Several specimens, each with different delamination lengths are tested. Detailed, three-dimensional finite element analyses of the specimens were performed. The analysis results were used to calculate the distribution of mode I, mode II, and mode III strain energy release rate along the delamination front. The results indicated that mode III-dominated delamination growth would be initiated from the specimen center. However, in specimens of both material types, the measured values of G(sub IIIc) exhibited significant dependence on delamination length. Furthermore, there was a large amount of scatter in the data. Load-displacement response of the specimens exhibited significant deviation from linearity before specimen failure. X-radiographs of a sample of specimens revealed that damage was initiated in the specimens prior to failure. Further inspection of the failure surfaces is required to identify the damage and determine that mode III delamination is initiated in the specimens.

Ratcliffe, James G.↗

Generation and reduction of the data for the Ulysses gravitational wave experiment

A procedure for the generation and reduction of the radiometric data known as REGRES is described. The software is implemented on a HP-1000F computer and was tested on REGRES data relative to the Voyager I spacecraft. The REGRES data are a current output of NASA's Orbit Determination Program. The software package was developed in view of the data analysis of the gravitational wave experiment planned for the European spacecraft Ulysses.

Agresti, R.↗

MGGPOD: a Monte Carlo Suite for Modeling Instrumental Line and Continuum Backgrounds in Gamma-Ray Astronomy

Intense and complex instrumental backgrounds, against which the much smaller signals from celestial sources have to be discerned, are a notorious problem for low and intermediate energy gamma-ray astronomy (approximately 50 keV - 10 MeV). Therefore a detailed qualitative and quantitative understanding of instrumental line and continuum backgrounds is crucial for most stages of gamma-ray astronomy missions, ranging from the design and development of new instrumentation through performance prediction to data reduction. We have developed MGGPOD, a user-friendly suite of Monte Carlo codes built around the widely used GEANT (Version 3.21) package, to simulate ab initio the physical processes relevant for the production of instrumental backgrounds. These include the build-up and delayed decay of radioactive isotopes as well as the prompt de-excitation of excited nuclei, both of which give rise to a plethora of instrumental gamma-ray background lines in addition t o continuum backgrounds. The MGGPOD package and documentation are publicly available for download. We demonstrate the capabilities of the MGGPOD suite by modeling high resolution gamma-ray spectra recorded by the Transient Gamma-Ray Spectrometer (TGRS) on board Wind during 1995. The TGRS is a Ge spectrometer operating in the 40 keV to 8 MeV range. Due to its fine energy resolution, these spectra reveal the complex instrumental background in formidable detail, particularly the many prompt and delayed gamma-ray lines. We evaluate the successes and failures of the MGGPOD package in reproducing TGRS data, and provide identifications for the numerous instrumental lines.

Weidenspointner, G.↗

Preston Probe Calibrations at High Reynolds Number

The overall goal of the research effort is to study the performance of two Preston probes designed by NASA Langley Research Center across an unprecedented range of Reynolds number (based on friction velocity and probe diameter), and perform an accurate calibration over the same Reynolds number range. Using the Superpipe facility in Princeton, two rounds of experiments were performed. In each round of experiments for each Reynolds number, the pressure gradient, static pressure from the Preston probes and the total pressure from the Preston probes were measured. In the first round, 3 Preston probes having outer diameters of 0.058 inches, 0.083 inches and 0.203 inches were tested over a large range of pipe Reynolds numbers. Two data reduction methods were employed: first, the static pressure measured on the Preston probe was used to calculate P (modified Preston probe configuration), and secondly, the static pressure measured at the reference pressure tap was used to calculate P (un-modified Preston probe configuration). For both methods, the static pressure was adjusted to correspond with the static pressure at the Preston probe tip using the pressure gradient. The measurements for Preston probes with diameters of 0.058 inches, and 0.083 inches respectively were performed in the test pipe before it was polished a second time. Therefore, the measurements at high pipe Reynolds numbers may have been affected by roughness. In the second round of experiments the 0.058 inches and 0.083 inches diameter, un-modified probes were tested after the pipe was polished and prepared to ensure that the surface was smooth. The average velocity was estimated by assuming that the connection between the centerline velocity and the average velocity was known, and by using a Pitot tube to measure the centerline velocity. A preliminary error estimate suggests that it is possible to introduce a 1% to 2% error in estimating the average velocity using this approach. The evidence on the errors attending the second data set is somewhat circumstantial, and the measurements have not been repeated using a better approach, it seems probable that the correlation given applies to un-modified Preston probes over the range 6.4 less than x* less than 11.3.

Smits, Alexander J.↗

Investigation of Injector Slot Geometry on Curved-Diffuser Aerodynamic Performance

The Compressor Branch vision is to be recognized as world-class leaders in research for fluid mechanics of compressors. Its mission is to conduct research and develop technology to advance the state of the art of compressors and transfer new technology to U.S. industries. Maintain partnerships with U.S. industries, universities, and other government organizations. Maintain a balance between customers focused and long range research. Flow control comprises enabling technologies to meet compression system performance requirements driven by emissions and fuel reduction goals (e.g., in UEET), missions (e.g., access-to-space), aerodynamically aggressive vehicle configurations (e.g., UAV and future blended wing body configurations with highly distorted inlets), and cost goals (e.g., in VAATE). The compression system requirements include increased efficiency, power-to-weight, and adaptability (i.e., robustness in terms of wide operability, distortion tolerance, and engine system health and reliability). The compressor flow control task comprises efforts to develop, demonstrate, and transfer adaptive flow control technology to industry to increase aerodynamic loading at current blade row loss levels, to enable adaptive1 y wide operability, and to develop plant models for adaptive compression systems. In this context, flow control is the controlled modification of a flow field by a deliberate means beyond the natural (uncontrolled) shaping of the solid surfaces that define the principal flow path. The objective of the compressor flow control task is to develop and apply techniques that control circulation, aerodynamic blockage, and entropy production in order to enhance the performance and operability of compression systems for advanced aero-propulsion applications. This summer I would be working with a curved-diffuser because it simulates what happens with flow in the stator blades in the compressor. With this experiment I will be doing some data analysis and parametric study of the injector slot geometries to get the best aerodynamic performance of it. This includes some data reduction, redesign and fast prototyping of the injector nozzle.

Silva, Odlanier↗

Interchangeable end effector tools utilized on the PFMA

An instrumented task board, used for measuring forces applied by the Protoflight Manipulator Arm (PFMA) to the task board, was fabricated and delivered to Marshall Space Flight Center. SRS Technologies phased out the existing IBM compatible data acquisition system, used with a instrumented task board, and integrated the force measuring electronic hardware in with the Macintosh II data acquisition system. The purpose of this change was to acquire all data with the same time tag, allowing easier and more accurate data reduction in addition to real-time graphics. A three-dimensional optical position sensing system for determining the location of the PFMA's end effect or in reference to the center of the instrumented task board was also designed and delivered under. An improved task board was fabricated which included an improved instrumented beam design. The modified design of the task board improved the force/torque measurement system by increasing the sensitivity, reliability, load range and ease of maintenance. A calibration panel for the optical position system was also designed and fabricated. The calibration method developed for the position sensors enhanced the performance of the sensors as well as simplified the installation and calibration procedures required. The modifications made under this effort expanded the capabilities of the task board system. The system developed determines the arm's position relative to the task board and measures the signals to the joints resulting from the operator's control signals in addition to the task board forces. The software and hardware required to calculate and record the position of the PFMA during the performance of tasks with the instrumented task board were defined, designed and delivered to MSFC. PFMA joint input signals can be measured from a breakout box to evaluate the sensitivity or response of the arm operation to control commands. The data processing system provides the capability for post processing of time-history graphics and plots of the PFMA positions, the operator's actions, and the PFMA servo reactions in addition to realtime force and position sensor data presentation.

Cody, Joe↗

A 28 nm multiply-accumulate ASIC architecture for on-chip data compression in MHz frame rate X-ray and electron pixel detectors

Modern X-ray detector systems urgently require compact, efficient, and fast data compression schemes to handle the transmission of big data from pixel arrays, enabling frame rates in the MHz regime. Here, in this work, a data compression ASIC that implements a streaming fixed-length lossy compression scheme is introduced and analyzed, proving the feasibility and benefits of on-chip compression. The compression scheme utilizes a vector matrix product logic, which performs a number of floating-point multiplications, additions, and accumulations. The logic is verified, synthesized, and shown to fit in the area resource available for the X-ray detector under study, which comprises 192 × 168 pixels each of 12-bit width, and having a total area of 20 mm× 20 mm, about 2 mm× 20 mm of which are available for the digital logic. Several system architectures, precisions, and compression ratios ranging from 100 to 250 were analyzed to pave the way for on-chip fixed-length compression (e.g., principal component analysis, singular value decomposition) and data reduction (e.g., azimuthal integration) for X-ray and electron detectors.

Data compression↗

Revised astrometric calibration of the Gemini Planet Imager

We present a revision to the astrometric calibration of the Gemini Planet Imager (GPI), an instrument designed to achieve the high contrast at small angular separations necessary to image substellar and planetary-mass companions around nearby, young stars. We identified several issues with the GPI data reduction pipeline (DRP) that significantly affected the determination of the angle of north in reduced GPI images. As well as introducing a small error in position angle measurements for targets observed at small zenith distances, this error led to a significant error in the previous astrometric calibration that has affected all subsequent astrometric measurements. We present a detailed description of these issues and how they were corrected. We reduced GPI observations of calibration binaries taken periodically since the instrument was commissioned in 2014 using an updated version of the DRP. These measurements were compared to observations obtained with the NIRC2 instrument on Keck II, an instrument with an excellent astrometric calibration, allowing us to derive an updated plate scale and north offset angle for GPI. This revised astrometric calibration should be used to calibrate all measurements obtained with GPI for the purposes of precision astrometry.

79 ASTRONOMY AND ASTROPHYSICS↗

Hypergraph Analytics of Domain Name System Relationships

We report on the use of novel mathematical methods in hypergraph analytice over a large quantity of DNS data. Hypergraphs generalize graphs, as used in network science, to better model complex multiway relations in cyber data. Specifically, casting DNS data from Georgia Tech's ActiveDNS repository as hypergraphs allows us to fully represent the interactions between {\em collections} of domains and IP addresses. To facilitate large-scale analytics, we fielded an analytical pipeline of two capabilities. HyperNetX (HNX) is a Python package for the exploration and visualization of hypergraphs, acting as a frontend. For the backend, the Chapel HyperGraph Library (CHGL) is a library for high performance hypergraph analytics written in the exascale programming language Chapel. CHGL was used to process gigascale DNS data, performing compute-intensive calculations for data reduction and segmentation. Identified portions are then sent to HNX for both exploratory analysis and knowledge discovery targeting known tactics, techniques, and procedures.

Joslyn, Cliff A.↗