Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data acquisition systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

System Acquires Data On Reactivities Of Foams

Data-acquisition and -plotting system, called DAPS(TM), developed enabling accurate and objective determination of physical properties related to reactivities of polyurethane and polyisocyanurate foams. Automated, computer-controlled test apparatus that acquires data on rates of rise, rise profiles, exothermic temperatures, and internal pressures of foams prepared from both manual and machine-mixed batches. Data used to determine minute differences between reaction kinetics and exothermic profiles of foam formulations, properties of end products which are statistically undifferentiated.

Walls, Joe T.↗

Acquisition of and Access to Research Omics Data

Omics data are essential for understanding the myriad and complex effects of space environments on humans. To assure maximum benefit from these kinds of data, the NASA Human Research Program Data Management Plan stipulates that human omics data should be archived within and accessed through the NASA Life Sciences Portal (NLSP). The NLSP has the capability to acquire and provision access to omics (and other kinds of) research results for individual and ad-hoc groups of subjects at the direction of institutional review boards, or other authorizing bodies or individuals, per institutional, program and investigation-specific policies and procedures. However, because some single-subject omics data, like CT scans and other kinds of large, complex biomedical data, could be used to identify heretofore unknown risks to the subject’s health, or, in certain cases, be used to identify a subject, NASA Policy Directive 7170.1 describes various policies regarding the management of and access to “research genetic testing” data, which includes many kinds of omics data. For example, NPD 7170.1 prohibits access to human research genetic data by NASA personnel who make employment decisions for the subjects from whom the data were obtained. To meet the objective of acquiring research omics data for NLSP in compliance with the policies in NPD 7170.1 and other applicable NASA policies, we designed NOMADS (the NLSP Omics Multimodal Acquisition of Data System), a new component that supports the transfer of large research data files, including research genetic testing data, using one of several different transfer mechanisms. The choice of mechanism is made by the submitter of the data, with guiding information from the system, and is likely to often be determined in large part by the nature and source location of the data. For example, for small files where the source data files are not already stored in a cloud storage system, users are likely to prefer to transfer their data to the NLSP via a web browser. Conversely, for large sets of files already organized and stored in a cloud storage system, users may opt for NOMAD’s cloud-to-cloud transfer method. All omics datasets targeted for the NASA Life Sciences Data Archive must pass a variety of quality checks to ensure data integrity and adherence to the standards defined by the LSDA Data Submission Guidelines (DSG) (see https://nlsp.nasa.gov/explore/lsdahome/datasubmit). These include requirements that data are consistent with open standards established by the omics community. Non-compliant data will not be accepted however archivists are available to advise submitters on how to revise data submissions and re-submit until compliance is achieved. Following compliance with the LSDA DSG, omics data next undergo a variety of additional quality checks to ensure the data meet omics community standards. Domain specific Omics data quality control tools and techniques are continually evolving and linked to the advancements in omics assays utilized and thus, the tools and techniques utilized by the LSDA for data quality control and validation will need to be sustained accordingly. All human omics data will be access controlled according to the policies described above, and requiring IRB approval for any additional access grants once the data are acquired (including access for analysis using the NLSP workspace tools).

Omics↗

Acquisition of and Access to Research Omics Data

Omics data are essential for understanding the myriad and complex effects of space environments on humans. To assure maximum benefit from these kinds of data, the NASA Human Research Program Data Management Plan stipulates that human omics data should be archived within and accessed through the NASA Life Sciences Portal (NLSP). The NLSP has the capability to acquire and provision access to omics (and other kinds of) research results for individual and ad-hoc groups of subjects at the direction of institutional review boards, or other authorizing bodies or individuals, per institutional, program and investigation-specific policies and procedures. However, because some single-subject omics data, like CT scans and other kinds of large, complex biomedical data, could be used to identify heretofore unknown risks to the subject’s health, or, in certain cases, be used to identify a subject, NASA Policy Directive 7170.1 describes various policies regarding the management of and access to “research genetic testing” data, which includes many kinds of omics data. For example, NPD 7170.1 prohibits access to human research genetic data by NASA personnel who make employment decisions for the subjects from whom the data were obtained. To meet the objective of acquiring research omics data for NLSP in compliance with the policies in NPD 7170.1 and other applicable NASA policies, we designed NOMADS (the NLSP Omics Multimodal Acquisition of Data System), a new component that supports the transfer of large research data files, including research genetic testing data, using one of several different transfer mechanisms. The choice of mechanism is made by the submitter of the data, with guiding information from the system, and is likely to often be determined in large part by the nature and source location of the data. For example, for small files where the source data files are not already stored in a cloud storage system, users are likely to prefer to transfer their data to the NLSP via a web browser. Conversely, for large sets of files already organized and stored in a cloud storage system, users may opt for NOMAD’s cloud-to-cloud transfer method. All omics datasets targeted for the NASA Life Sciences Data Archive must pass a variety of quality checks to ensure data integrity and adherence to the standards defined by the LSDA Data Submission Guidelines (DSG) (see https://nlsp.nasa.gov/explore/lsdahome/datasubmit). These include requirements that data are consistent with open standards established by the omics community. Non-compliant data will not be accepted however archivists are available to advise submitters on how to revise data submissions and re-submit until compliance is achieved. Following compliance with the LSDA DSG, omics data next undergo a variety of additional quality checks to ensure the data meet omics community standards. Domain specific Omics data quality control tools and techniques are continually evolving and linked to the advancements in omics assays utilized and thus, the tools and techniques utilized by the LSDA for data quality control and validation will need to be sustained accordingly. All human omics data will be access controlled according to the policies described above, and requiring IRB approval for any additional access grants once the data are acquired (including access for analysis using the NLSP workspace tools).

Omics↗

Modular Biometric Monitoring System

A modular system for acquiring biometric data includes a plurality of data acquisition modules configured to sample biometric data from at least one respective input channel at a data acquisition rate. A representation of the sampled biometric data is stored in memory of each of the plurality of data acquisition modules. A central control system is in communication with each of the plurality of data acquisition modules through a bus. The central control system is configured to control communication of data, via the bus, with each of the plurality of data acquisition modules.

Chmiel, Alan J.↗

The NASA Tracking and Data Relay Satellite System and its impact on spacecraft support in the space transportation system era

The space tracking, data acquisition and communication network systems and capabilities available to NASA are discussed, with emphasis on the Tracking and Data Relay Satellite System (TDRSS). Scheduled to come into operation in 1983, TDRSS will be the prime support system for communication with the Space Shuttle, Spacelab, and the automated spacecraft to be launched into earth orbit by the Space Transportation System. TDRSS will consist of two specialized data relay satellites in geosynchronous orbit, about 130 deg apart; each TDRSS spacecraft has a three-axis stabilized configuration, with sun-oriented solar panels, and will weigh about 2200 kg at launch. The NASA Spaceflight Tracking and Data Network, currently used to support 30-40 spacecraft per day, is described, and plans for changes in the network are discussed. The 26 antennas of the network will be consolidated into an expanded Deep Space Network, after TDRSS is in operation.

Smylie, R. E.↗

A functional video-based anthropometric measuring system

A high-speed anthropometric three dimensional measurement system using the Selcom Selspot motion tracking instrument for visual data acquisition is discussed. A three-dimensional scanning system was created which collects video, audio, and performance data on a single standard video cassette recorder. Recording rates of 1 megabit per second for periods of up to two hours are possible with the system design. A high-speed off-the-shelf motion analysis system for collecting optical information as used. The video recording adapter (VRA) is interfaced to the Selspot data acquisition system.

Nixon, J. H.↗

Electric Six Degree of Freedom Installation Timelapse (Six Degree of Freedom Dynamic Test System)

The Six-degree-of-freedom Dynamic Test System (SDTS) is a short-range real-time motion based testing platform. Its primary use at NASA/JSC has been for development and qualification testing of docking systems, robotic assisted berthing mechanisms, and dynamic attachment systems. The SDTS is a closed-loop force feedback system that can simulate on-orbit contact dynamics between two vehicles utilizing the actual mechanical interfaces for testing. The facility is controlled by interconnected computers running real-time simulation software that takes measured contact forces, integrates the equations of motion in real time, and provide those states back into the motion table. This infrastructure can also be used for non-mating applications such as relative position sensor testing/evaluations. The SDTS facility provides a superstructure for mounting test articles, multiple test sensors, an intercom network for voice communications, and a synchronized timing system for data acquisition that includes HD video. This time-lapse video shows the buildup and testing of a modern electric actuation system created by Mikrolar, Inc. at the Johnson Space Center. This motion base will replace the current hydraulic actuator system, which is been in use since the 1970s, for all-future NASA testing. Once the system goes through customization to provide JSC’s unique closed-loop environment, the facility will help certify docking system and attach mechanisms on the ground before we send the first woman and the next man to the lunar surface

hexapod↗

Assessment of Operation of EMK21 MEMS Silicon Oscillator Over Wide Temperature Range

Electronic control systems, data-acquisition instrumentation, and microprocessors require accurate timing signals for proper operation. Traditionally, ceramic resonators and crystal oscillators provided this clock function for the majority of these systems. Over the last few years, MEMS (Micro-Electro-Mechanical Systems) resonator-based oscillators began to surface as commercial-off-the-shelf (COTS) parts by a few companies. These quartz-free, miniature silicon devices could easily replace the traditional crystal oscillators in providing the timing/clock function for many digital and analog circuits. They are reported to provide stable output frequency, offer great tolerance to shock and vibration, and are immune to electro-static discharge [ 1-2]. In addition, they are encapsulated in compact lead-free packages and cover a wide frequency range (1 MHz to 125 MHz). The small size of the MEMS oscillators along with their thermal stability make them ideal candidates for use in space exploration missions. Limited data, however, exist on the performance and reliability of these devices under operation in applications where extreme temperatures or thermal cycling swings, which are typical of space missions, are encountered. This report presents the results of the work obtained on the evaluation of an Ecliptek Corporation MEMS silicon oscillator chip under extreme temperatures.

Patterson, Richard L.↗

LV software for supersonic flow analysis

The NASA Lewis Research Center (LeRC) maintains a leadership position in research into advanced aerospace propulsion systems. For the next generation of aircraft, engine designs continue to involve complex, high-speed flows. Performing the detailed flow diagnostics to properly evaluate these designs requires advanced instrumentation to probe these highly turbulent flows. The hostile flow environment often requires nonintrusive measurement techniques such as the laser velocimeter (LV). Since the LV is a proven instrument for nonintrusive flow measurement, it can provide quantitative velocity data with minimal interference to the flow. Based on anticipated flow conditions, laser velocimeter systems were procured from TSI, Inc. The initial system utilized counter processor technology, but later procurements this past year include a more advanced, correlator-based processor, which significantly improves the overall LV performance. To meet the needs of advanced research into propulsion, this instrument must be integrated into an existing VAX/VMS computer system for data acquisition, processing, and presentation. The work done under this grant before this period concentrated on developing the software required to setup and acquire data from the TSI MI-990 multichannel interface, and the RMR 1989 rotating machinery resolver. With the basis established for controlling the operation of the LV system, software development this past year shifted in emphasis from instrumentation control and data acquisition to data analysis and presentation. The progress of the program is reported.

Bell, William A.↗

Interactive signal analysis and ultrasonic data collection system user's manual

The interactive signal analysis and ultrasonic data collection system (ECHO1) is a real time data acquisition and display system. ECHO1 executed on a PDP-11/45 computer under the RT11 real time operating system. Extensive operator interaction provided the requisite parameters to the data collection, calculation, and data modules. Data were acquired in real time from a pulse echo ultrasonic system using a Biomation Model 8100 transient recorder. The data consisted of 2084 intensity values representing the amplitude of pulses transmitted and received by the ultrasonic unit.

Smith, G. R.↗

Preliminary design package for solar heating and hot water system

Two prototype solar heating and hot water systems for use in single-family dwellings or commercial buildings were designed. Subsystems included are: collector, storage, transport, hot water, auxiliary energy, and government-furnished site data acquisition. The systems are designed for Yosemite, California, and Pueblo, Colorado. The necessary information to evaluate the preliminary design for these solar heating and hot water systems is presented. Included are a proposed instrumentation plan, a training program, hazard analysis, preliminary design drawings, and other information about the design of the system.

Source record↗

Implications of Dynamic Pressure Transducer Mounting Variations on Measurements in Pyrotechnic Test Apparatus

Accurate dynamic pressure measurements are often difficult to make within small pyrotechnic devices, and transducer mounting difficulties can cause data anomalies that lead to erroneous conclusions. Delayed initial pressure response followed by data ringing has been observed when using miniaturized pressure transducer mounting adapters required to interface transducers to small test chambers. This delayed pressure response and ringing, combined with a high data acquisition rate, has complicated data analysis. This paper compares the output signal characteristics from different pressure transducer mounting options, where the passage distance from the transducer face to the pyrotechnic chamber is varied in length and diameter. By analyzing the data and understating the associated system dynamics, a more realistic understanding of the actual dynamic pressure variations is achieved. Three pressure transducer mounting configurations (elongated, standard, and face/flush mount) were simultaneously tested using NASA standard initiators in closed volume pressure bombs. This paper also presents results of these pressure transducer mounting configurations as a result of a larger NASA Engineering and Safety Center pyrovalve test project. Results from these tests indicate the improved performance of using face/flush mounted pressure transducers in this application. This type of mounting improved initial pressure measurement response time by approximately 19 s over standard adapter mounting, eliminating most of the lag time; provided a near step-function type initial pressure increase; and greatly reduced data ringing in high data acquisition rate systems. The paper goes on to discuss other issues associated with the firing and instrumentation that are important for the tester to understand.

Dibbern, Andreas↗

The Results of Dynamic Data Acquisition During Mars Pathfinder Prototype Airbag Drop Testing

The Mars Pathfinder mission, scheduled for launch in December 1996, will use an airbag system to safely deliver a lander to the Martian surface.The airbag landing system has undergone a comprehensive test program during its evolution from initial design phase to final qualification and acceptance testing. This paper outlines the test approach used in the airbag development program, describes the data acquisition system used to obtain and evaluate airbag performance data, and presents test results.

airbags Mars Mars Pathfinder Mars lander data acqu↗

Nuclear Science Symposium, 25th, and Symposium on Nuclear Power Systems, 10th, Washington, D.C., October 18-20, 1978, Proceedings

Detectors of various types are discussed, taking into account drift chambers, calorimetry, multiwire proportional chambers, signal processing, the use of semiconductors, and photo/optical applications. Circuits are considered along with instrumentation for space, nuclear medicine instrumentation, data acquisition and systems, environmental instrumentation, reactor instrumentation, and nuclear power systems. Attention is given to a new approach to high accuracy gaseous detectors, the current status of electron mobility and free-ion yield in high mobility liquids, a digital drift chamber digitizer system, the stability of oxides in high purity germanium, the quadrant photomultiplier, and the theory of imaging with a very limited number of projections.

Source record↗

Results of the recent precipitation static flight test program on the Navy P-3B antisubmarine aircraft

Severe precipitation static problems affecting the communication equipment onboard the P-3B aircraft were recently studied. The study was conducted after precipitation static created potential safety-of-flight problems on Naval Reserve aircraft. A specially designed flight test program was conducted in order to measure, record, analyze, and characterize potential precipitation static problem areas. The test program successfully characterized the precipitation static interference problems while the P-3B was flown in moderate to extreme precipitation conditions. Data up to 400 MHz were collected on the effects of engine charging, precipitation static, and extreme cross fields. These data were collected using a computer controlled acquisition system consisting of a signal generator, RF spectrum and audio analyzers, data recorders, and instrumented static dischargers. The test program is outlined and the computer controlled data acquisition system is described in detail which was used during flight and ground testing. The correlation of test results is also discussed which were recorded during the flight test program and those measured during ground testing.

Whitaker, Mike↗

Adaptation of solar sounding rocket payloads for Shuttle

The advent of the Shuttle will permit small solar sounding rocket class payloads to be used for orbital applications as a sub satellite. Solutions to such problems as thermal protection, deployment and retrieval and Shuttle bay storage will be presented. Adapting sounding rocket hardware such as solar telescopes, solar attitude control systems and data acquisition modules along with extending power and control gas requirements is discussed. This resulting hardware may be used either in a sounding rocket or Shuttle payload. This paper will combine the solar sounding rocket quick reaction, low cost techniques with the Shuttle Transportation System.

Windsor, R. M.↗

MAC to VAX Connectivity: Heartrate Spectral Analysis System

The heart rate Spectral Analysis System (SAS) acquires and analyzes, in real-time, the Space Shuttle onboard electrocardiograph (EKG) experiment signals, calculates the heartrate, and applies a Fast Fourier Transformation (FFT) to the heart rate. The system also calculates other statistical parameters such as the 'mean heart rate' over specific time period and heart rate histogram. This SAS is used by NASA Principal Investigators as a research tool to determine the effects of weightlessness on the human cardiovascular system. This is also used to determine if Lower Body Negative Pressure (LBNP) is an effective countermeasure to the orthostatic intolerance experienced by astronauts upon return to normal gravity. In microgravity, astronauts perform the LBNP experiment in the mid deck of the Space Shuttle. The experiment data are downlinked by the orbiter telemetry system, then processed and analyzed in real-time by the integrated Life Sciences Data Acquisition (LSDS) - Spectral Analysis System. The data system is integrated within the framework of two different computer systems, VAX and Macintosh (Mac), using the networking infrastructure to assist the investigators in further understanding the most complex machine on Earth--the human body.

Rahman, Hasan H.↗