Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “current conservation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Time Matters: A Survival Analysis of Public Electric Vehicle Charging Infrastructure Utilization

The rapid adoption of plug-in electric vehicles (PEVs) places significant demands on public charging infrastructure, making it critical to understand and optimize charger utilization. This study provides one of the most comprehensive analyses of charging behavior to date by applying a survival analysis to a dataset of nearly 16 million level 2 (L2) and direct current (DC) fast charger sessions across the United States from 2017 to 2022. Using Kaplan-Meier curves and log rank tests, our analysis reveals statistically significant and distinct duration patterns influenced by charger type, time of day, and day of the week. We find that L2 charging sessions exhibit high variability tied to venue type, whereas DC sessions are more uniform, typically lasting 30-45 min. This study introduces the operational efficiency score (OES), a metric for standardizing the performance evaluation of charging stations. Our findings offer actionable insights for optimizing charger deployment, developing dynamic pricing strategies to reduce vehicle dwell time, and improving load management for grid operators, ultimately enhancing the efficiency and availability of public charging infrastructure.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost Analysis of Annual and Monthly Net Zero Energy Performance for Multifamily Buildings in the United States

As the United States continues its progress toward sustainable construction, net zero building design is becoming an increasingly important and popular topic. Two definitions of net zero energy performance, monthly and annual, provide different levels of energy autonomy and efficiency within a building. This article analyzes the viability and incremental cost for two-, three-, and four-story multifamily apartment buildings to reach both annual and monthly net zero energy performance throughout four climate zones in the United States using baseline reference buildings that represent current construction practices. Building size plays a large role in determining the capability for a building model to reach annual or monthly net zero. Two-story buildings are capable of reaching annual net zero with an increase in construction cost of about 4.4–5.6%. Three-story buildings in warmer climates can achieve annual net zero with an increase of about 5.1%, but models in colder climates cannot reach annual net zero performance. Four-story buildings cannot achieve net zero, owing to insufficient building area for solar arrays to produce electricity. Monthly net zero energy performance was significantly harder to achieve, with the only case reaching this goal being the two-story Houston based model, at an added cost of 8.2%. Generally speaking, only small buildings in warm climates will be able to achieve monthly net zero without vastly oversizing photovoltaic systems and increasing costs without adequate payback.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Environmental associations of Ophidiomyces ophidiicola , the causative agent of ophidiomycosis in snakes

Emerging pathogenic fungi have become a topic of conservation concern due to declines observed in several host taxa. One emerging fungal pathogen, Ophidiomyces ophidiicola, is well documented as the causative agent of ophidiomycosis, otherwise known as snake fungal disease (SFD). O. ophidiicola has been found to cause disease in a variety of snake species across the United States, including the eastern massasauga (Sistrurus catenatus), a federally threatened rattlesnake species. Most work to date has involved detecting O. ophidiicola for diagnosis of infection through direct sampling of snakes, and attempts to detect O. ophidiicola in the abiotic environment to better understand its distribution, seasonality, and habitat associations are lacking. We collected topsoil and groundwater samples from four macrohabitat types across multiple seasons in northern Michigan at a site where Ophidiomyces infection has been confirmed in eastern massasauga. Using a quantitative PCR (qPCR) assay developed for O. ophidiicola, we detected Ophidiomyces DNA in topsoil but observed minimal to no detection in groundwater samples. Detection frequency did not differ between habitats, but samples grouped seasonally showed higher detection during mid-summer. We found no relationships of detection with hypothesized environmental correlates such as soil pH, temperature, or moisture content. Furthermore, the distribution of Ophidiomyces positive samples across the site was not linked to estimated space use of massasaugas. Our data suggests that season has some effect on the presence of Ophidiomyces. Differences in presence between habitats may exist but are likely more dependent on the time of sampling and currently uninvestigated soil or biotic parameters. These findings build on our understanding of Ophidiomyces ecology and epidemiology to help inform where and when snakes may be exposed to the fungus in the environment.

59 BASIC BIOLOGICAL SCIENCES↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Microgrid design and multi-year dispatch optimization under climate-informed load and renewable resource uncertainty

Microgrids are an increasingly popular solution to provide energy resilience in response to increasing grid dependency and the growing impacts of climate change on grid operations. However, existing microgrid models do not currently consider the uncertain and long-term impacts of climate change when determining a set of design and operational decisions to minimize long-term costs or meet a resilience threshold. In this paper, we develop a novel scenario generation method that accounts for the uncertain effects of (i) climate change on variable renewable energy availability, (ii) extreme heat events on site load, and (iii) population and electrification trends on load growth. Additionally, we develop a two-stage stochastic programming extension of an existing microgrid design and dispatch optimization model to obtain uncertainty-informed and climate-resilient energy system decisions that minimizes long-term costs. Use of sample average approximation to validate our two case studies illustrates that the proposed methodology produces high-quality solutions that add resilience to systems with existing backup generation while reducing expected long-term costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Review and Analysis of Heat Transfer Correlations For Horizontal Pseudocritical CO 2 Heat Exchanger Applications

There is significant interest in the development of supercritical carbon dioxide (sCO 2 ) power cycles because of the potential for smaller and more energy efficient systems than a steam Rankine cycle. Heat exchanger designs typically use empirical correlations, but the applicability of these correlations near the CO 2 critical point is a potential issue. Though numerous correlations have been proposed in the literature, there are some disagreements when it comes to the accuracy. The current work recognizes the role of thermophysical properties, and its impacts on the heat transfer correlations and cycle efficiency. Heat transfer correlations proposed for horizontal flow inside circular pipes were analyzed with the help of numerical simulations. Steady state RANS simulations were performed using SST k-w turbulence model to evaluate the Nusselt number empirical correlations. It was found that the most of correlations (except Yoon) produced a Nusselt number that differed significantly with the one predicted numerically. Some of the correlations were developed for pure forced convection regime and as mentioned in Lin et al. do not account for mixed convection or free convection effects. Based on the limited observation, it appears that Yoon et al. predictions match well with the numerically predicted Nusselt Numbers. However, further analysis is required understand the applicability of various correlations and is contingent on accurate measurements or predictions of wall temperature profiles in the axial and the circumferential directions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Low Environmental Impact Distributed Scroll Booster Technology for Supermarket Refrigeration

A distributed scroll booster refrigeration system is proposed as an alternative for current refrigeration systems used in supermarket applications. The distributed scroll booster system is configured to enable the use of low-pressure refrigerants such as R-1234yf, which has a global warming potential (GWP) of less than 1, in a cycle configuration that employs a two-stage compression process. This scroll booster system is comprised of medium-temperature compressors (high stage) coupled with low-temperature compressors (low stage). This two-stage system architecture allows both low-temperature and medium-temperature refrigerated display cases to be integrated in the same system. By design, this system reduces the refrigerant charge, produces higher efficiencies (two-stage compression), uses existing components minimizing cost impact, and will be able to use ultra-low GWP class A2L (low toxicity and low flammability) refrigerants such as R-1234yf when standards and building codes are updated (expected by 2025).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Influence of the Bulk Resistivity on Silicon Heterojunction Solar Cells and Module Reliability

Recent developments in industry on surface passivation open the possibility of using less doped substrates in silicon solar cells. In this report we investigate how the bulk resistivity affects the performance of silicon cells and the reliability of modules. Herein, n- and p-type silicon heterojunction cells with bulk resistivities between 3 and 15 000 Ωcm are studied. We measure the current–voltage characteristics of n-type cells across the resistivity range, and we find comparable responses to illumination intensities between 0.1 and 1 suns. The cells with bulk resistivities over 1000 Ωcm show breakdown voltages larger than -1000 V, almost two orders of magnitude higher than in typical commercial cells. Although modules have bypass-diodes to prevent cells from going into breakdown, higher breakdown voltages can improve the reliability of modules in case of bypass-diode failure and reduce the module cost by easing the number of bypass-diodes required. Finally, the cells have been submitted to light soaking. The float-zone p-type cells with bulk resistivities over 10 000 Ωcm are less sensitive to light-induced degradation than cells with bulk resistivities below 10 Ωcm. The former show to recover few hours after light soaking, while the latter recover only after dark annealing.

14 SOLAR ENERGY↗

Increasing the Number of Installed Residential Heat Pump Water Heaters in the USA Through Improved Technology and Utility Programs

Heat pump water heaters (HPWHs) offer an efficient alternative to electric resistance water heaters, but they suffer from limited market penetration. This paper reviews the current state of HPWHs in the USA, focusing on technology developments and programs to increase adoption. What technological improvements are needed to make HPWHs a good fit in more homes? Additionally, what are the best ways of promoting HPWHs to consumers? Improved communication and controls will allow HPWHs to provide demand response and follow dynamic utility rates. To enable fuel-switching, HPWHs are being developed that only need a standard 120V outlet. Split HPWHs can alleviate the cooling and noise that limit the use of HPWHs in small homes, multifamily buildings, and cold climates. Additionally, new utility programs aim to train installers and provide incentives to distributors to increase the number of HPWHs installed. Some utilities offer novel incentive programs that have led to increased customer uptake. Those advances, coupled with improved controls for load shifting and new products such as split HPWHs and HPWHs that can run on 120V power, may finally move the market forward.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost Analysis Framework for Comparing AC and DC Design Alternatives for Building Electrical Distribution Systems

In recent years, in response to the changing nature of building load, direct current (DC) distribution systems for buildings have been proposed as alternatives to traditional alternating current (AC) systems. DC distribution offers a closer match to the types of loads and generation sources found in modern buildings, the majority of which use DC electricity internally either natively or as a power conditioning stage. The proposed benefits of DC distribution compared to AC distribution within buildings include higher efficiency, lower installation cost, lower operating cost, higher reliability, improved communication and control, and simplicity. Most recent DC distribution research has focused on quantifying the efficiency advantage of DC distribution over AC distribution. However, energy savings alone do not guarantee cost savings; a more complete cost accounting is required to establish financial benefit. This report provides a framework for cost analysis and comparison of building electrical distribution systems, including common variants for both AC and DC distribution systems. The framework includes all major cost categories, including up-front costs (capital, installation labor, soft costs) and long-term costs (energy, operations and maintenance).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Learning-based CO 2 concentration prediction: Application to indoor air quality control using demand-controlled ventilation

There have been increasing concerns over the air quality inside buildings as high levels of bio-effluents can cause nausea, dizziness, headaches, and fatigue to the people working in those spaces. First published in 2004 as Standard 62.1, ASHRAE Standard 62.2-2019 requires highly occupied spaces to implement heating, ventilation, and air conditioning (HVAC) that can dilute contaminants produced by occupants. In this regard, occupant-centric ventilation control has been regarded as an effective practice to maintain a satisfactory indoor air quality (IAQ) when dealing with highly variable occupancy environments. However, few established models in current literature and practice consider dynamic occupancy behavior and adaptive IAQ control. To address this gap, a dynamic indoor CO2 model is constructed using machine learning algorithms to forecast CO2concentrations across a range of forecasting horizons. Herein, we tuned and compared six state-of-the-algorithms—including Support Vector Machine, Ada Boost, Random Forest, Gradient Boosting, Logistic Regression, and Multilayer Perceptron. The algorithms’ performances are validated using CO 2 and historical meteorological data collected from a campus classroom with a variable occupancy rate. Simulation results showed that Multilayer Perceptron can strongly predict the volatile CO 2 behavior and also outperforms other algorithms in terms of accuracy. Furthermore, a control strategy capable of modeling and detecting dynamic patterns of CO 2 level is utilized to modulate the ventilation rate in real-time and also reduce the energy consumption. The proposed controller reduced the HVAC fan’s energy consumption by 51.4% and provide ventilation as needed per the ASHRAE standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Robotics for Systems Integration in Buildings: Pilot Study of Viable Approaches to Install Hygrothermal and Rigid Electrical Systems

The Industrialized Construction Innovation (ICI) team at the National Renewable Energy Laboratory (NREL) has been exploring the use of robotics to integrate hygrothermal, mechanical, electrical, and plumbing systems in prefabricated building assemblies (off-site construction) and 3D-printed buildings (on-site construction). Such multisystem integration tasks often require specialized robots and custom end effectors to handle a range of rigid and nonrigid building components. This paper begins with a brief overview of the current state of robotics in construction, followed by a pilot study exploring the use of robotics to integrate a simple prototype multitrade wall assembly composed of structural studs, hygrothermal layer, wall finishing, and electrical fixtures. The study was funded by the US Department of Energy's (DOE's) Advanced Materials and Manufacturing Technologies Office (AMMTO). Insights about the implementation of design for manufacturing and assembly (DfMA) principles in designing the prototype wall for robotic assembly, and selection of appropriate robotic end-effector hardware to handle these components are included. Detailed comparison of computational toolpath simulations of the robotic assembly process and real-life demonstration of the same are presented. Finally, limitations and lessons learned from this study are included, along with future research recommendations for robotic assembly of more complex multitrade assemblies, including potential scenarios such as robotic outfitting of facilities in extraterrestrial environments.

advanced manufacturing↗

Electrochemical-assisted leaching of active materials from lithium ion batteries

The development of a circular economy for lithium-ion batteries (LIB) is essential to realize decarbonization and an electrified energy market. However, the current commercial operations that recover valuable constituents from LIBs require significant energy and reagents, which create toxic emissions and additional waste. We report an electrochemical-based method for leaching valuable metals from the active materials of mixed shredded LIBs. In this process, the use electrons, as green reagent, allows the use and regeneration of Fe 2+ in low concentrations as substitute for hydrogen peroxide as a reducing agent. Leaching in a membrane separated two-compartment electrochemical cell contributes to decrease the acid requirements as H+ can be generated electrochemically. With this design, leaching efficiencies over 96% for the active metals (Li, Co, Mn, and Ni) were demonstrated at pulp densities up to 240 g/L. Copper present in the active material is electrowon and recovered separately. Preliminary cost analyses demonstrate ca. 80% reduction in energy and chemical costs as compared to traditional hydrometallurgical routes.

25 ENERGY STORAGE↗

Pathways of clean energy heating electrification programs for reducing carbon emissions in Northwest China

We report clean energy heating electrification programs provide a promising way to reduce carbon emissions from fossil fuel combustion and consumption. This work studies the cost competitiveness of clean energy heating technologies under three dynamic mechanisms: investment costs, subsidy policies, and operating costs with real data. It provides key insights into the cost competitiveness of the different heating technologies deployed in different areas, as well as their sensitivity to the three dynamic mechanisms. The results show that currently, the distinct heating programs are more cost-efficient in the urban area with existing heating networks. The average payback period of all district clean energy heating programs in the urban area is 14.9 years, while that of the individual clean heating programs is 24.7 years. The individual heating programs are becoming increasingly cost-competitive with the incentive mechanisms, especially the electricity pricing mechanisms. Moreover, individual heating technologies present remarkable advantages on flexibility and sustainability in the long run. According to the technology diffusion model proposed in this paper, the individual clean heating programs will occupy more than 50% of the market share in 2050 under the comprehensive effect of CAPEX, government subsidies, and OPEX. The real-world results and analysis render references to shape the pathway of clean energy heating electrification in Northwest China and other regions with a similar situation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development and Application of Schema Based Occupant-Centric Building Performance Metrics

Occupant behavior can significantly influence the operation and performance of buildings. Many occupant-centric key performance indicators (KPIs) rely on having accurate counts of the number of occupants in a building, which is very different to how occupancy information is currently collected in the majority of buildings today. To address this gap, the authors develop a standardized methodology for the calculation of percent space utilization for buildings, which is formulated with respect to two prevalent operational data schemas: the Brick Schema and Project Haystack. The methodology is scalable across different levels of spatial granularity and irrespective of sensor placement. Moreover, the methods are intended to make use of typical occupancy sensors that capture presence level occupancy and not counts of people. Since occupant-hours is a preferable metric to use in KPI calculations, a method to convert between percent space utilization and occupant-hours using the design occupancy for a space is also developed. The methodology is demonstrated on a small commercial office space in Boulder, Colorado using data collected between June 2018 and February 2019. A multiple linear regression is performed that shows strong evidence for a relationship between building energy consumption and percent space utilization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enabling thermal efficiency improvement and waste heat recovery using liquid air harnessed from offshore renewable energy sources

A novel approach using decoupled processes to harness offshore renewable energy, from marine hydrokinetics, ocean waves, wind, and solar to produce liquid air, is presented here. Offshore renewables interconnection using submarine medium- and high-voltage direct current technologies are used to produce liquid air that can be transported to end-use locations using repurposed liquefied natural gas tankers. Two important possibilities arise from using the proposed technology. The first possibility allows the integration with conventional thermal cycles to improve efficiency. This approach can be used to leverage efficiencies of thermal systems that have already reached a plateau in the maximum achievable efficiency via design and operation optimization. The second possibility is related to the incorporation of low temperature cycles to recover waste heat from other thermal processes. This is important considering that waste heat accounts for more than 60% of the consumed energy in the United States. A detailed technical description of the complete cycle from cryogen generation to end-use of energy is provided. Estimation of efficiency enhancement for thermal plants using liquid air including waste heat recovery is presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Continuum Correlations from CFD-DEM Modeling of Conduction Heat Transfer in Granular Flows

Heat transfer between a surface and flowing particles is analyzed to improve the accuracy of continuum models for wall-to-bed heat transfer in a fluidized bed. Discrete element modeling (DEM) is used to model a fluidized bed heat exchanger where heat enters the system through a heated wall. The DEM heat transfer predictions are validated against published experimental work (Brewster et al., 2024) with less than 15% error. In previous work by Morris et al. (2015), a continuum model was developed using data from high-fidelity DEM simulations of chute flows. In the current study, the continuum model is extended and validated for fluidized beds. The sensitivity of the continuum heat transfer model parameters, which was not quantified in previous studies, is also investigated. It is observed that for a given particle with specific properties, e.g. the particle size, roughness, and conduction lens radius, the continuum correlation developed for heat transfer from a heated boundary to the particle bed depends mainly on the solid fraction or porosity of the particle bed for a given fluid. The new continuum heat transfer model is then validated over a wide range of superficial velocities via comparisons to both discrete element and experimental data. It is shown that this correlation is valid for a large range of particle flow conditions from chute flows to fluidized beds with less than 10% error as compared to DEM predictions.

14 SOLAR ENERGY↗

Results of the 2018 Wood Stove Design Challenge

The 2018 Wood Stove Design Challenge was an international design competition which sought to identify top performing residential wood stoves based on automation. To prepare for the event, the Northeast States for Coordinated Air Use Management (NESCAUM) developed a testing protocol that challenged the stoves by testing them in more field-like conditions—capturing emissions from start-up, reloading a stove, and the use of larger piece sizes. Flue gas emissions were measured using a combination of in-stack and novel dilution sampling methods, as the event occurred on the National Mall in Washington D.C. in a non-laboratory setting. Particulate matter (PM), carbon monoxide (CO), carbon dioxide (CO2), and methane (CH4) were measured from three stoves in real-time. A combustion efficiency was also calculated for each stove in real-time. Measured PM emission rates ranged between 1.8 and 8.0 g/hr for all stoves and operating conditions, with the highest emissions being measured during cold start in all cases. The test average PM emission rates were 2.4, 4.0, and 2.4 g/hr for stoves A, B, and C, respectively. Results showed emissions measured during transient operations, which are often excluded in current certification methods, can be significantly higher than steady-state periods—echoing other studies and highlighting the importance of testing in various operational modes for more realistic emission estimates. Additionally, the stoves had overall CO emission rates of 48.8, 284.8, and 100.8 g/hr, for stoves A, B and C, respectively. Calculated PM and CO emission factors overall were low considering the testing protocol sought to follow more challenging yet realistic practices in terms of fuel loading and operating procedures. The overall estimated combustion efficiency for stoves A, B, and C was 85%, 78%, 76%, respectively and in all cases was lowest during the cold start period.This report details the successfully proposed and assembled instrumentation that was relatively portable for field-site testing and the results of the emissions measurements for the 2018 Wood Stove Design Challenge competition. Overall, the repeatability of each stove was favorable with coefficients of variation (COV) ranging from 7 to 15% for measured PM concentrations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗