Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coverage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

The growth of sulfur adlayers on Au(100)

We have studied the growth of S layers adsorbed on Au(100) with low-energy electron diffraction (LEED), X-ray photoemission spectra (XPS), and scanning tunneling microscope (STM). Three phases of S/Au(100)—(2 × 2), trimer, and c(2 × 4)—are identified; the latter two are not previously reported. A dose of S{sub 2} at 300 K transformed Au(100)-(5 × 20) initially into the (2 × 2) phase and formed the c(2 × 4) phase at a saturation coverage. The STM results show that monolayer Au islands formed during the initial S dose and remained throughout the growth, resulting in a rough c(2 × 4) surface. We show that a highly ordered c(2 × 4) phase can be obtained with a flat (2 × 2) phase as an intermediate step during growth. Based on the evolution of XPS and STM images with varied S{sub 2} dose, the components of S 2p are assigned and structural models for the various S/Au(100) phases are proposed. In the (2 × 2) phase, one S atom resides on a four-fold hollow site in each (2 × 2) unit cell, corresponding to a S coverage of 0.25 ML; in the trimer phase, three S atoms form a trimer residing on a four-fold hollow site in each (2 × 2) unit cell, corresponding to a S coverage of 0.75 ML; in the c(2 × 4) phase, there are five S atoms in each primitive unit cell of c(2 × 4); three of them form a trimer residing on a four-fold hollow site, and the other two form a dimer located on the top of the trimer, corresponding to a nominal S coverage of 1.25 ML. With the proposed structural models, the growth of S on Au(100) at 300 K is described in detail.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electronic growth of Pd(111) nanostructures on MoS 2

Quantum confinement effects can induce the formation of discrete nanostructures with well-defined preferred heights in thin metallic films. In most systems, such electronic growth modes are weak and limited to cryogenic conditions. Recently, however, we have discovered that metals grown upon van der Waals surfaces can exhibit electronic growth at, or even above, room temperature to spontaneously form well-defined and highly stable nanostructures. Here, we explore the initial stages of room temperature deposition of Pd onto MoS 2 . We found that, even for minimal thicknesses, Pd spontaneously formed discrete islands with three atomic layers. The islands maintained this preferred height for nominal coverages below three atomic layers. At higher coverages, the preferred height switched abruptly to six atomic layers. Unlike previous studies using Au or Ag, the islands did not increase laterally with coverage but rather increased in number with lateral size remaining about the same. The preferred heights in Pd/MoS 2 correlate to the Pd Fermi surface topography and are also consistent with thicknesses showing minima in the density of states at the Fermi level, which suggest that the electronic growth modes are the driving factors in these self-assembled Pd nanostructures. The Pd system shows a preference for island nucleation compared to Au and Ag which grow laterally with increasing coverage. Furthermore, this is likely related to differences in bonding at the interface as Pd is typically much more reactive than Ag or Au.

36 MATERIALS SCIENCE↗

The Lick Observatory Supernova Search follow-up program: photometry data release of 70 SESNe

We present BVRI and unfiltered (Clear) light curves of 70 stripped-envelope supernovae (SESNe), observed between 2003 and 2020, from the Lick Observatory Supernova Search follow-up program. Our SESN sample consists of 19 spectroscopically normal SNe Ib, 2 peculiar SNe Ib, six SNe Ibn, 14 normal SNe Ic, 1 peculiar SN Ic, 10 SNe Ic-BL, 15 SNe IIb, 1 ambiguous SN IIb/Ib/c, and 2 superluminous SNe. Our follow-up photometry has (on a per-SN basis) a mean coverage of 81 photometric points (median of 58 points) and a mean cadence of 3.6 d (median of 1.2 d). From our full sample, a subset of 38 SNe have pre-maximum coverage in at least one passband, allowing for the peak brightness of each SN in this subset to be quantitatively determined. We describe our data collection and processing techniques, with emphasis toward our automated photometry pipeline, from which we derive publicly available data products to enable and encourage further study by the community. Using these data products, we derive host-galaxy extinction values through the empirical colour evolution relationship and, for the first time, produce accurate rise-time measurements for a large sample of SESNe in both optical and infrared passbands. By modelling multiband light curves, we find that SNe Ic tend to have lower ejecta masses and lower ejecta velocities than SNe Ib and IIb, but higher 56Ni masses.

Lick Observatory↗

Base Station Antenna Uptilt Optimization for Cellular-Connected Drone Corridors

Reliable wireless coverage in drone corridors is critical to enable a connected, safe, and secure airspace. To support beyond visual line of sight (BVLOS) operations of aerial vehicles in a drone corridor, cellular base stations (BSs) can serve as a convenient infrastructure as they are widely deployed to provide seamless wireless coverage. However, antennas in the existing cellular networks are down-tilted to optimally serve their ground users, which results in coverage holes at higher altitudes when they are used to serve drones. In this paper, we consider the use of additional uptilted antennas at each cellular BS and optimize the uptilt angle to maximize the wireless coverage probability across a given drone corridor. Through numerical results, we can characterize the optimal value of the antenna uptilt angle for a given antenna pattern as well as the minimum/maximum altitudes of the drone corridor.

42 ENGINEERING↗

Upgrades to the Thomson Scattering Diagnostic on the Lithium Tokamak eXperiment-Beta (LTX-$β$)

We describe the upgrades to the Thomson scattering (TS) diagnostic on the Lithium Tokamak eXperiment-beta (LTX- β ) to provide complete radial coverage of the plasma. LTX- β is a spherical tokamak with plasma limited at a major radius of R = 14 cm and R = 66 cm. Flat temperature profiles with peaked density were observed in LTX- β using an existing multipoint TS diagnostic with radial coverage of the plasma core. There is a need for more comprehensive core and edge TS measurements to thoroughly examine beam fueling, beam heating, and transport under low recycling conditions with liquid lithium walls and a lower collisionality scrape-off layer (SOL). The core TS set up provides plasma profiles from R = 40–60 cm. To extend the TS diagnostic coverage: 1) we added a TS viewing optics to cover the SOL region at five radial points from R = 57–64 cm, and 2) another TS viewing optics in the HFS region from R = 15–45 cm to obtain TS data from ten radial positions while making use of the original laser beam. The main focus of this article is on the new HFS TS setup that is equipped with better-matched collection optics located in the horizontal midplane where the laser polarization lies and views from a scattering angle of 130°–150° with respect to the laser path. A set of unequal-length Y-branched fiber bundles transports the TS light from two radial points to each polychromator. The new HFS view is better matched in spot size, scattering angle, and throughput to the laser and polychromators and has new V-grooved style viewing dumps. The new HFS TS view, along with the core and SOL TS views, will provide a full radial measurement coverage from R = 15–64 cm to explore the flat temperature profiles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparing traditional and Bayesian approaches to ecological meta‐analysis

Abstract Despite the wide application of meta‐analysis in ecology, some of the traditional methods used for meta‐analysis may not perform well given the type of data characteristic of ecological meta‐analyses. We reviewed published meta‐analyses on the ecological impacts of global climate change, evaluating the number of replicates used in the primary studies ( n i ) and the number of studies or records ( k ) that were aggregated to calculate a mean effect size. We used the results of the review in a simulation experiment to assess the performance of conventional frequentist and Bayesian meta‐analysis methods for estimating a mean effect size and its uncertainty interval. Our literature review showed that n i and k were highly variable, distributions were right‐skewed and were generally small (median n i = 5, median k = 44). Our simulations show that the choice of method for calculating uncertainty intervals was critical for obtaining appropriate coverage (close to the nominal value of 0.95). When k was low (<40), 95% coverage was achieved by a confidence interval (CI) based on the t distribution that uses an adjusted standard error (the Hartung–Knapp–Sidik–Jonkman, HKSJ), or by a Bayesian credible interval, whereas bootstrap or z distribution CIs had lower coverage. Despite the importance of the method to calculate the uncertainty interval, 39% of the meta‐analyses reviewed did not report the method used, and of the 61% that did, 94% used a potentially problematic method, which may be a consequence of software defaults. In general, for a simple random‐effects meta‐analysis, the performance of the best frequentist and Bayesian methods was similar for the same combinations of factors ( k and mean replication), though the Bayesian approach had higher than nominal (>95%) coverage for the mean effect when k was very low ( k < 15). Our literature review suggests that many meta‐analyses that used z distribution or bootstrapping CIs may have overestimated the statistical significance of their results when the number of studies was low; more appropriate methods need to be adopted in ecological meta‐analyses.

Pappalardo, Paula↗

Assessing biogeographic survey gaps in bacterial diversity knowledge: A global synthesis of freshwaters

Freshwaters account for 0.8% of Earth's surface area, yet support >10% of known plant and animal species making them disproportionately biodiverse. Modern molecular techniques have begun to reveal microbial diversity, but application of these approaches to address global microbial biogeography is relatively unknown in freshwaters. Our aim was to identify gaps in microbial data coverage along climatic and landscape disturbance gradients and among terrestrial biomes and hydrographic regions for all freshwater ecosystems and three freshwater habitat types: lakes and reservoirs (lentic); streams and rivers (lotic); and wetlands. We reviewed literature on microbial diversity in freshwaters surveyed using 16S ribosomal RNA sequencing which identify microbial taxa. We georeferenced survey locations and used a geographic information system to identify and map gaps in survey coverage using open-source data for climate, landscape disturbance, terrestrial biomes, and freshwater ecoregions. In our study, we compiled 3,425 georeferenced survey locations reported from 963 studies. Streams were surveyed most frequently (60.8% of survey locations), followed by lakes (33.5%) and wetlands (5.6%). Surveys were concentrated in North America, central and western Europe, and Southeast Asia; 35% of freshwater ecoregions were surveyed at least once across freshwater habitat types, whereas 23%, 23%, and 12% were surveyed at least once for lentic, lotic, and wetland habitat types, respectively. The climatic gap analysis indicated coverage is high for temperate regions but lacking in the tropics and Arctic, particularly for wetland ecosystems. Our assessment revealed high climatic coverage of freshwater microbial diversity knowledge, but expansive ecoregional gaps attributable to biased sampling near research institutions in North America, western Europe, and China. Future surveys should target ecoregions in Africa, South America, Central Asia, Australia, and Antarctica. An essential next step will be to curate and disseminate sequencing efforts to facilitate the study of processes driving global diversity patterns.

16S rRNA↗

High-throughput sequencing of the chloroplast and mitochondrion of Chlamydomonas reinhardtii to generate improved de novo assemblies, analyze expression patterns and transcript speciation, and evaluate diversity among laboratory strains and wild isolates

Chlamydomonas reinhardtii is a unicellular chlorophyte alga that is widely studied as a reference organism for understanding photosynthesis, sensory and motile cilia, and for development of an algal-based platform for producing biofuels and bio-products. Its highly repetitive, ~205-kbp circular chloroplast genome and ~15.8-kbp linear mitochondrial genome were sequenced prior to the advent of high-throughput sequencing technologies. Here, high coverage shotgun sequencing was used to assemble both organellar genomes de novo. These new genomes correct dozens of errors in the prior genome sequences and annotations. Gen-ome sequencing coverage indicates that each cell contains on average 83 copies of the chloroplast genome and 130 copies of the mitochondrial genome. Using protocols and analyses optimized for organellar tran-scripts, RNA-Seq was used to quantify their relative abundances across 12 different growth conditions. Forty-six percent of total cellular mRNA is attributable to high expression from a few dozen chloroplast genes. RNA-Seq data were used to guide gene annotation, to demonstrate polycistronic gene expression, and to quantify splicing of psaA and psbA introns. In contrast to a conclusion from a recent study, we found that chloroplast transcripts are not edited. Unexpectedly, cytosine-rich polynucleotide tails were observed at the 3’-end of all mitochondrial transcripts. A comparative genomics analysis of eight laboratory strains and 11 wild isolates of C. reinhardtii identified 2658 variants in the organellargenomes, which is 1/10th as much genetic diversity as is found in the nucleus.

ftsH↗

Growth of ordered SrO layers on Si(100) using metal-organic surface reactions

The formation of ordered alkaline earth metal-oxide layers on Si(100) through metal-organic surface reactions has been investigated. Strontium oxide layers were deposited on a thin (1.0{+-}0.2 nm) SiO{sub 2} layer grown on Si(100) using a saturation coverage of the {beta}-diketonate precursor bis(2,2,6,6-tetramethyl-3,5-heptanedionato)strontium [Sr(thd){sub 2}] followed by reaction with H{sub 2}O. Oxide desorption at high temperatures (>800 deg. C) leads to an ordered strontium layer on the silicon surface. Auger electron spectroscopy, x-ray photoelectron spectroscopy, Rutherford backscattering spectrometry, and low-energy electron diffraction have been used to investigate the progress of the reaction. The data show a Sr/Si(100) surface with 3x order and a Sr coverage of (0.9{+-}0.1)x10{sup 14}/cm{sup 2}. The observed metal coverage and ordering are explained by the saturation of the adsorbed metal-organic layer due to steric interactions that limit the adsorbed coverage. The results are promising for alternative methods to fabricate epitaxial oxides on silicon substrates.

36 MATERIALS SCIENCE↗

X-ray photoelectron spectroscopy study of para-substituted benzoic acids chemisorbed to aluminum oxide thin films

A series of para-substituted, halogenated (F, Cl, Br, and I) benzoic acid monolayers were prepared on the native oxide of aluminum surfaces by solution self-assembly and spin-coating techniques. The monolayers were characterized by x-ray photoelectron spectroscopy (XPS) and water contact angles. Several general trends are apparent. First, the polarity of the solvent is critical to monolayer formation. Protic polar solvents produced low coverage monolayers; in contrast, nonpolar solvents produced higher coverage monolayers. Second, solution deposition yields a higher surface coverage than spin coating. Third, the thickness of the monolayers determined from XPS suggests the plane of the aromatic ring is perpendicular to the surface with the carboxylate functional group most likely binding in a bidentate chelating geometry. Fourth, the saturation coverage (∼2.7 × 10{sup 14} molecules cm{sup −2}) is independent of the para-substituent.

36 MATERIALS SCIENCE↗

Attenuator design for organs at risk in total body irradiation using a translation technique

Total body irradiation (TBI) is an efficient part of the treatment for malignant hematological diseases. Dynamic TBI techniques provide great advantages (e.g., dose homogeneity, patient comfort) while overcoming treatment room space restrictions. However, with dynamic techniques come additional organs at risk (OAR) protection challenges. In most dynamic TBI techniques, lead attenuators are used to diminish the dose received by the OARs. The purpose of this study was to characterize the dose deposition under various shapes of attenuators in static and dynamic treatments. This characterization allows for the development of a correction method to improve attenuator design in dynamic treatments. The dose deposition under attenuators at different depths in dynamic treatment was compared with the static situation based on two definitions: the coverage areas and the penumbra regions. The coverage area decreases with depth in dynamic treatment while it is stable for the static situation. The penumbra increases with depth in both treatment modes, but the increasing rate is higher in the dynamic situation. Since the attenuator coverage is deficient in the dynamic treatment mode, a correction method was developed to modify the attenuator design in order to improve the OAR protection. The correction method is divided in two steps. The first step is based on the use of elongation charts, which provide appropriate attenuator coverage and acceptable penumbra for a specific depth. The second point is a correction method for the thoracic inclination, which can introduce an orientation problem in both static and dynamic treatments. This two steps correction method is simple to use and personalized to each patient's anatomy. It can easily be adapted to any dynamic TBI techniques.

61 RADIATION PROTECTION AND DOSIMETRY↗

A characterization of robust radiation therapy treatment planning methods-from expected value to worst case optimization

Purpose: To characterize a class of optimization formulations used to handle systematic and random errors in radiation therapy, and to study the differences between the methods within this class. Methods: The class of robust methods that can be formulated as minimax stochastic programs is studied. This class generalizes many previously used methods, ranging between optimization of the expected and the worst case objective value. The robust methods are used to plan intensity-modulated proton therapy (IMPT) treatments for a case subject to systematic setup and range errors, random setup errors with and without uncertain probability distribution, and combinations thereof. As reference, plans resulting from a conventional method that uses a margin to account for errors are shown. Results: For all types of errors, target coverage robustness increased with the conservativeness of the method. For systematic errors, best case organ at risk (OAR) doses increased and worst case doses decreased with the conservativeness. Accounting for random errors of fixed probability distribution resulted in heterogeneous dose. The heterogeneities were reduced when uncertainty in the probability distribution was accounted for. Doing so, the OAR doses decreased with the conservativeness. All robust methods studied resulted in more robust target coverage and lower OAR doses than the conventional method. Conclusions: Accounting for uncertainties is essential to ensure plan quality in complex radiation therapy such as IMPT. The utilization of more information than conventional in the optimization can lead to robust target coverage and low OAR doses. Increased target coverage robustness can be achieved by more conservative methods.

60 APPLIED LIFE SCIENCES↗

Dose-shaping using targeted sparse optimization

Purpose: Dose volume histograms (DVHs) are common tools in radiation therapy treatment planning to characterize plan quality. As statistical metrics, DVHs provide a compact summary of the underlying plan at the cost of losing spatial information: the same or similar dose-volume histograms can arise from substantially different spatial dose maps. This is exactly the reason why physicians and physicists scrutinize dose maps even after they satisfy all DVH endpoints numerically. However, up to this point, little has been done to control spatial phenomena, such as the spatial distribution of hot spots, which has significant clinical implications. To this end, the authors propose a novel objective function that enables a more direct tradeoff between target coverage, organ-sparing, and planning target volume (PTV) homogeneity, and presents our findings from four prostate cases, a pancreas case, and a head-and-neck case to illustrate the advantages and general applicability of our method.Methods: In designing the energy minimization objective (E{sub tot}{sup sparse}), the authors utilized the following robust cost functions: (1) an asymmetric linear well function to allow differential penalties for underdose, relaxation of prescription dose, and overdose in the PTV; (2) a two-piece linear function to heavily penalize high dose and mildly penalize low and intermediate dose in organs-at risk (OARs); and (3) a total variation energy, i.e., the L{sub 1} norm applied to the first-order approximation of the dose gradient in the PTV. By minimizing a weighted sum of these robust costs, general conformity to dose prescription and dose-gradient prescription is achieved while encouraging prescription violations to follow a Laplace distribution. In contrast, conventional quadratic objectives are associated with a Gaussian distribution of violations, which is less forgiving to large violations of prescription than the Laplace distribution. As a result, the proposed objective E{sub tot}{sup sparse} improves tradeoff between planning goals by 'sacrificing' voxels that have already been violated to improve PTV coverage, PTV homogeneity, and/or OAR-sparing. In doing so, overall plan quality is increased since these large violations only arise if a net reduction in E{sub tot}{sup sparse} occurs as a result. For example, large violations to dose prescription in the PTV in E{sub tot}{sup sparse}-optimized plans will naturally localize to voxels in and around PTV-OAR overlaps where OAR-sparing may be increased without compromising target coverage. The authors compared the results of our method and the corresponding clinical plans using analyses of DVH plots, dose maps, and two quantitative metrics that quantify PTV homogeneity and overdose. These metrics do not penalize underdose since E{sub tot}{sup sparse}-optimized plans were planned such that their target coverage was similar or better than that of the clinical plans. Finally, plan deliverability was assessed with the 2D modulation index.Results: The proposed method was implemented using IBM's CPLEX optimization package (ILOG CPLEX, Sunnyvale, CA) and required 1-4 min to solve with a 12-core Intel i7 processor. In the testing procedure, the authors optimized for several points on the Pareto surface of four 7-field 6MV prostate cases that were optimized for different levels of PTV homogeneity and OAR-sparing. The generated results were compared against each other and the clinical plan by analyzing their DVH plots and dose maps. After developing intuition by planning the four prostate cases, which had relatively few tradeoffs, the authors applied our method to a 7-field 6 MV pancreas case and a 9-field 6MV head-and-neck case to test the potential impact of our method on more challenging cases. The authors found that our formulation: (1) provided excellent flexibility for balancing OAR-sparing with PTV homogeneity; and (2) permitted the dose planner more control over the evolution of the PTV's spatial dose distribution than conventional objective functions. In particular, E{sub tot}{sup sparse}-optimized plans for the pancreas case and head-and-neck case exhibited substantially improved sparing of the spinal cord and parotid glands, respectively, while maintaining or improving sparing for other OARs and markedly improving PTV homogeneity. Plan deliverability for E{sub tot}{sup sparse}-optimized plans was shown to be better than their associated clinical plans, according to the two-dimensional modulation index.Conclusions: These results suggest that our formulation may be used to improve dose-shaping and OAR-sparing for complicated disease sites, such as the pancreas or head and neck. Furthermore, our objective function and constraints are linear and constitute a linear program, which converges to the global minimum quickly, and can be easily implemented in treatment planning software. Thus, the authors expect fast translation of our method to the clinic where it may have a positive impact on plan quality for challenging disease sites.

61 RADIATION PROTECTION AND DOSIMETRY↗

A stochastic model for tumor geometry evolution during radiation therapy in cervical cancer

Purpose: To develop mathematical models to predict the evolution of tumor geometry in cervical cancer undergoing radiation therapy. Methods: The authors develop two mathematical models to estimate tumor geometry change: a Markov model and an isomorphic shrinkage model. The Markov model describes tumor evolution by investigating the change in state (either tumor or nontumor) of voxels on the tumor surface. It assumes that the evolution follows a Markov process. Transition probabilities are obtained using maximum likelihood estimation and depend on the states of neighboring voxels. The isomorphic shrinkage model describes tumor shrinkage or growth in terms of layers of voxels on the tumor surface, instead of modeling individual voxels. The two proposed models were applied to data from 29 cervical cancer patients treated at Princess Margaret Cancer Centre and then compared to a constant volume approach. Model performance was measured using sensitivity and specificity. Results: The Markov model outperformed both the isomorphic shrinkage and constant volume models in terms of the trade-off between sensitivity (target coverage) and specificity (normal tissue sparing). Generally, the Markov model achieved a few percentage points in improvement in either sensitivity or specificity compared to the other models. The isomorphic shrinkage model was comparable to the Markov approach under certain parameter settings. Convex tumor shapes were easier to predict. Conclusions: By modeling tumor geometry change at the voxel level using a probabilistic model, improvements in target coverage and normal tissue sparing are possible. Our Markov model is flexible and has tunable parameters to adjust model performance to meet a range of criteria. Such a model may support the development of an adaptive paradigm for radiation therapy of cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-19A-07: Dosimetric Comparison of HDR Plesiotherapy and Electron Beam Therapy for Superficial Lesions

Purpose: Large superficial (skin, soft tissue sarcoma) lesions located on curved areas are hard to treat with electrons. The Freiburg Flap (Nucletron, Netherlands) is a flexible mesh style surface which can be easily shaped to fit curved surfaces for reproducible HDR fraction delivery. To understand the fundamental dosimetric differences, a dosimetric comparison was made between HDR plesiotherapy (Freiburg applicator for lesions over 4cm) and external electron beam radiotherapy over cases with varying target curvature (both stylized and clinical cases). Methods: Four stylized cases with variable complexity were created using artificial DICOM axial CT slices and RT structures (a square and three curved structures on a 4.5cm radius cylinder). They were planned using Oncentra v4.3 and exported to Pinnacle v9.6 for electrons planning. The HDR source dwell positions were optimized for the best coverage of the targets using graphical optimization. Electron treatment plans were created in Pinnacle using the same CT and RT structures of three HDR cases with surface lesions previously treated with the Freiburg flap. The En face electron plans used 6-12 MeV electrons and 0.5–1 cm bolus was added to increase surface dose. The electron plans were prescribed to an isodose line to conform to the target. Results: For all lesions, the average target dose coverage was similar (D90ave of 100% for HDR vs 101% for electrons). For lesions with high curvature, the HDR coverage was better (D90 102% vs D90 97% for electron). For all cases, adjacent structures high dose region was lower for HDR than electrons (D1cc 100% for HDR vs D1cc 111% for electrons). Conclusion: HDR plesiotherapy offers excellent target conformity for superficial targets similar to electrons. However, for lesions with complex curved surfaces, HDR has the advantage to achieve better dose distributions using graphical optimization to spare adjacent normal tissue while maximizing target coverage.

60 APPLIED LIFE SCIENCES↗

SU-E-T-170: Evaluation of Rotational Errors in Proton Therapy Planning of Lung Cancer

Purpose: To investigate the impact of rotational (roll, yaw, and pitch) errors in proton therapy planning of lung cancer. Methods: A lung cancer case treated at our center was used in this retrospective study. The original plan was generated using two proton fields (posterior-anterior and left-lateral) with XiO treatment planning system (TPS) and delivered using uniform scanning proton therapy system. First, the computed tomography (CT) set of original lung treatment plan was re-sampled for rotational (roll, yaw, and pitch) angles ranged from −5° to +5°, with an increment of 2.5°. Second, 12 new proton plans were generated in XiO using the 12 re-sampled CT datasets. The same beam conditions, isocenter, and devices were used in new treatment plans as in the original plan. All 12 new proton plans were compared with original plan for planning target volume (PTV) coverage and maximum dose to spinal cord (cord Dmax). Results: PTV coverage was reduced in all 12 new proton plans when compared to that of original plan. Specifically, PTV coverage was reduced by 0.03% to 1.22% for roll, by 0.05% to 1.14% for yaw, and by 0.10% to 3.22% for pitch errors. In comparison to original plan, the cord Dmax in new proton plans was reduced by 8.21% to 25.81% for +2.5° to +5° pitch, by 5.28% to 20.71% for +2.5° to +5° yaw, and by 5.28% to 14.47% for −2.5° to −5° roll. In contrast, cord Dmax was increased by 3.80% to 3.86% for −2.5° to −5° pitch, by 0.63% to 3.25% for −2.5° to −5° yaw, and by 3.75% to 4.54% for +2.5° to +5° roll. Conclusion: PTV coverage was reduced by up to 3.22% for rotational error of 5°. The cord Dmax could increase or decrease depending on the direction of rotational error, beam angles, and the location of lung tumor.

60 APPLIED LIFE SCIENCES↗

SU-E-T-224: Is Monte Carlo Dose Calculation Method Necessary for Cyberknife Brain Treatment Planning?

Purpose: To study the dosimetric difference resulted in using the pencil beam algorithm instead of Monte Carlo (MC) methods for tumors adjacent to the skull. Methods: We retrospectively calculated the dosimetric differences between RT and MC algorithms for brain tumors treated with CyberKnife located adjacent to the skull for 18 patients (total of 27 tumors). The median tumor sizes was 0.53-cc (range 0.018-cc to 26.2-cc). The absolute mean distance from the tumor to the skull was 2.11 mm (range - 17.0 mm to 9.2 mm). The dosimetric variables examined include the mean, maximum, and minimum doses to the target, the target coverage (TC) and conformality index. The MC calculation used the same MUs as the RT dose calculation without further normalization and 1% statistical uncertainty. The differences were analyzed by tumor size and distance from the skull. Results: The TC was generally reduced with the MC calculation (24 out of 27 cases). The average difference in TC between RT and MC was 3.3% (range 0.0% to 23.5%). When the TC was deemed unacceptable, the plans were re-normalized in order to increase the TC to 99%. This resulted in a 6.9% maximum change in the prescription isodose line. The maximum changes in the mean, maximum, and minimum doses were 5.4 %, 7.7%, and 8.4%, respectively, before re-normalization. When the TC was analyzed with regards to target size, it was found that the worst coverage occurred with the smaller targets (0.018-cc). When the TC was analyzed with regards to the distance to the skull, there was no correlation between proximity to the skull and TC between the RT and MC plans. Conclusions: For smaller targets (< 4.0-cc), MC should be used to re-evaluate the dose coverage after RT is used for the initial dose calculation in order to ensure target coverage.

60 APPLIED LIFE SCIENCES↗