Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

ALMACAL I: FIRST DUAL-BAND NUMBER COUNTS FROM A DEEP AND WIDE ALMA SUBMILLIMETER SURVEY, FREE FROM COSMIC VARIANCE

We have exploited ALMA calibration observations to carry out a novel, wide, and deep submillimeter (submm) survey, almacal. These calibration data comprise a large number of observations of calibrator fields in a variety of frequency bands and array configurations. By gathering together data acquired during multiple visits to many ALMA calibrators, it is possible to reach noise levels which allow the detection of faint, dusty, star-forming galaxies (DSFGs) over a significant area. In this paper, we outline our survey strategy and report the first results. We have analyzed data for 69 calibrators, reaching depths of ∼25 μ Jy beam{sup −1} at sub-arcsec resolution. Adopting a conservative approach based on ≥5 σ detections, we have found 8 and 11 DSFGs in ALMA bands 6 and 7, respectively, with flux densities S {sub 1.2} m {sub m} ≥ 0.2 mJy. The faintest galaxies would have been missed by even the deepest Herschel surveys. Our cumulative number counts have been determined independently at 870 μ m and 1.2 mm from a sparse sampling of the astronomical sky, and are thus relatively free of cosmic variance. The counts are lower than reported previously by a factor of at least 2×. Future analyses will yield large, secure samples of DSFGs with redshifts determined via the detection of submm spectral lines. Uniquely, our strategy then allows for morphological studies of very faint DSFGs—representative of more normal star-forming galaxies than conventional submm galaxies—in fields where self-calibration is feasible, yielding milliarcsecond spatial resolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Neutron counting and gamma spectroscopy with PVT detectors.

Radiation portals normally incorporate a dedicated neutron counter and a gamma-ray detector with at least some spectroscopic capability. This paper describes the design and presents characterization data for a detection system called PVT-NG, which uses large polyvinyl toluene (PVT) detectors to monitor both types of radiation. The detector material is surrounded by polyvinyl chloride (PVC), which emits high-energy gamma rays following neutron capture reactions. Assessments based on high-energy gamma rays are well suited for the detection of neutron sources, particularly in border security applications, because few isotopes in the normal stream of commerce have significant gamma ray yields above 3 MeV. Therefore, an increased count rate for high-energy gamma rays is a strong indicator for the presence of a neutron source. The sensitivity of the PVT-NG sensor to bare {sup 252}Cf is 1.9 counts per second per nanogram (cps/ng) and the sensitivity for {sup 252}Cf surrounded by 2.5 cm of polyethylene is 2.3 cps/ng. The PVT-NG sensor is a proof-of-principal sensor that was not fully optimized. The neutron detector sensitivity could be improved, for instance, by using additional moderator. The PVT-NG detectors and associated electronics are designed to provide improved resolution, gain stability, and performance at high-count rates relative to PVT detectors in typical radiation portals. As well as addressing the needs for neutron detection, these characteristics are also desirable for analysis of the gamma-ray spectra. Accurate isotope identification results were obtained despite the common impression that the absence of photopeaks makes data collected by PVT detectors unsuitable for spectroscopic analysis. The PVT detectors in the PVT-NG unit are used for both gamma-ray and neutron detection, so the sensitive volume exceeds the volume of the detection elements in portals that use dedicated components to detect each type of radiation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of Rayleigh-Taylor Instability: Statistics on Rising Bubbles and Falling Spikes

The analysis of coherent structures in Rayleigh-Taylor simulations is a challenging task as the lack of a precise definition of these structures is compounded by the massive size of the datasets. In an earlier work, we used techniques from image analysis to count these coherent structures in two high-resolution simulations, one a large-eddy simulation with 30 terabytes of analysis data, and the other a direct numerical simulation with 80 terabytes of analysis data. Our analysis indicated that there were four distinct regimes in the process of the mixing of the two fluids, starting from the initial linear stage, followed by the non-linear stage with weak turbulence, the mixing transition stage, and the final stage of strong turbulence. In this paper, we extend our earlier work to focus on only the rising bubbles and the falling spikes. We first consider different ways in which we can constrain the bubble and spike definitions and then extract various statistics on them. Our results on the rising bubble and falling spike counts again show that there are four regimes in the process of fluid mixing, each characterized by an integer-valued slope. Further, the average bubble heights and spike depths are related to similar results obtained using a threshold-based definition. Finally, the ratio of the rising bubbles to all bubbles is very similar in character to the ratio of the falling spikes to all spikes, with near constant values over part of the simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

RFe{sub 2}Mg{sub x}Al{sub 8−x} (R=La–Nd and Sm; x≈0.8): Flux synthesis, structure, magnetic and electrical properties

Single crystals of Mg-substituted CeFe{sub 2}Al{sub 8} type intermetallics RFe{sub 2}Mg{sub x}Al{sub 8–x} (R=La–Nd and Sm; x≤1) were grown by reacting iron and rare earth metals in 1:1 Mg/Al mixed flux. The structure features mono-capped and bi-capped trigonal prismatic FeAl{sub 6} units. Electronic structure calculations indicate that magnesium substitution reduces the valence electron count, shifting the Fermi level away from a pseudo-gap. This changes the electronic nature of the cerium analog; the previously reported ternary CeFe{sub 2}Al{sub 8} shows strong hybridization between the cerium states and the conduction electrons, resulting in no magnetic moment on Ce atoms. On the other hand, magnetic susceptibility measurements on CeFe{sub 2}Mg{sub x}Al{sub 8–x} indicates a localized moment on cerium. The newly synthesized Pr, Nd and Sm analogs exhibit antiferromagnetic ordering at 2.8 K, 7.8 K and 12 K respectively. Solid state {sup 27}Al NMR of LaFe{sub 2}Mg{sub x}Al{sub 8–x} exhibits a broad Knight shift at ~1200 ppm, consistent with the metallic behavior shown by electrical resistivity data. - Graphical abstract: Mg substitution into CeFe{sub 2}Al{sub 8} modifies cerium valence due to changing valence electron count. - Highlights: • RFe{sub 2}Mg{sub x}Al{sub 8−x} (R=La–Nd, Sm) grow as large crystals from reactions in Mg/Al flux. • Products are magnesium-substituted variants of CeFe{sub 2}Al{sub 8}, with CaCo{sub 2}Al{sub 8} structure. • Ce magnetic moment in CeFe{sub 2}Mg{sub x}Al{sub 8−x} varies from that in CeFe{sub 2}Al{sub 8} due to VEC change. • Antiferromagnetic ordering observed for Pr, Nd, Sm analogs of RFe{sub 2}Mg{sub x}Al{sub 8−x}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dilaton EFT framework for lattice data

We develop an effective-field-theory (EFT) framework to analyze the spectra emerging from lattice simulations of a large class of confining gauge theories. Simulations of these theories, for which the light-fermion count is not far below the critical value for transition to infrared conformal behavior, have indicated the presence of a remarkably light singlet scalar particle. We incorporate this particle by including a scalar field in the EFT along with the Nambu-Goldstone bosons (NGB’s), and discuss the application of this EFT to lattice data. We highlight the feature that data on the NGB’s alone can tightly restrict the form of the scalar interactions. As an example, we apply the framework to lattice data for an SU(3) gauge theory with eight fermion flavors, concluding that the EFT can describe the data well.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effects of High Count Rate and Gain Shift on Isotope Identification Algorithms

Spectroscopic gamma-ray detectors are used for many research applications, as well as Homeland Security screening applications. Sodium iodide (NaI) scintillator crystals coupled with photomultiplier tubes (PMTs) provide medium-resolution spectral data about the surrounding environment. NaI based detectors, paired with spectral identification algorithms, are often effective in identifying sources of interest by isotope. However, intrinsic limitations exist for NaI systems because of gain shifts and spectral marring (e.g., loss of resolution and count-rate saturation) at high count rates. These effects are hardware dependent, and have strong effects on the radioisotopic identification capability of these systems. In this work, the effects of high count rate on the capability of isotope identification algorithms are explored. It is shown that a small gain shift of a few tens of keV is sufficient to disturb identification. The onset of this and other spectral effects are estimated for several systems., and a mechanism for mitigating these effects by estimating and correcting for them is implemented and evaluated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HERSCHEL-ATLAS GALAXY COUNTS AND HIGH-REDSHIFT LUMINOSITY FUNCTIONS: THE FORMATION OF MASSIVE EARLY-TYPE GALAXIES

Exploiting the Herschel Astrophysical Terahertz Large Area Survey Science Demonstration Phase survey data, we have determined the luminosity functions (LFs) at rest-frame wavelengths of 100 and 250 {mu}m and at several redshifts z {approx}> 1, for bright submillimeter galaxies with star formation rates (SFRs) {approx}> 100 M{sub Sun} yr{sup -1}. We find that the evolution of the comoving LF is strong up to z Almost-Equal-To 2.5, and slows down at higher redshifts. From the LFs and the information on halo masses inferred from clustering analysis, we derived an average relation between SFR and halo mass (and its scatter). We also infer that the timescale of the main episode of dust-enshrouded star formation in massive halos (M{sub H} {approx}> 3 Multiplication-Sign 10{sup 12} M{sub Sun }) amounts to {approx}7 Multiplication-Sign 10{sup 8} yr. Given the SFRs, which are in the range of 10{sup 2}-10{sup 3} M{sub Sun} yr{sup -1}, this timescale implies final stellar masses of the order of 10{sup 11}-10{sup 12} M{sub Sun }. The corresponding stellar mass function matches the observed mass function of passively evolving galaxies at z {approx}> 1. The comparison of the statistics for submillimeter and UV-selected galaxies suggests that the dust-free, UV bright phase is {approx}> 10{sup 2} times shorter than the submillimeter bright phase, implying that the dust must form soon after the onset of star formation. Using a single reference spectral energy distribution (SED; the one of the z Almost-Equal-To 2.3 galaxy SMM J2135-0102), our simple physical model is able to reproduce not only the LFs at different redshifts >1 but also the counts at wavelengths ranging from 250 {mu}m to Almost-Equal-To 1 mm. Owing to the steepness of the counts and their relatively broad frequency range, this result suggests that the dispersion of submillimeter SEDs of z > 1 galaxies around the reference one is rather small.

79 ASTRONOMY AND ASTROPHYSICS↗

Effects of high count rate and gain shift on isotope identification algorithms

Spectroscopic gamma-ray detectors are used for many research, industrial, and homeland- security applications. Thallium-doped sodium iodide, (NaI(Tl)), scintillation crystals coupled to photomultiplier tubes provide medium-resolution spectral data about the surrounding environment. NaI(Tl)-based detectors, paired with spectral identification algorithms, are often effective for identifying gamma-ray sources by isotope. However, intrinsic limitations for NaI(Tl) systems exist, including gain shifts and spectral marring (e.g., loss of resolution and count-rate saturation) at high count rates. These effects are hardware dependent and have strong effects on the radioisotopic identification capability of NaI(Tl)-based systems. In this work, the effects of high count rate on the response of isotope-identification algorithms are explored. It is shown that a small gain shift of a few tens of keV is sufficient to disturb identification. The onset of this and other spectral effects is estimated for NaI(Tl) crystals, and a mechanism for mitigating these effects by estimating and correcting for them is implemented and evaluated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uncertainties of Mayak urine data

For internal dose calculations for the Mayak worker epidemiological study, quantitative estimates of uncertainty of the urine measurements are necessary. Some of the data consist of measurements of 24h urine excretion on successive days (e.g. 3 or 4 days). In a recent publication, dose calculations were done where the uncertainty of the urine measurements was estimated starting from the statistical standard deviation of these replicate mesurements. This approach is straightforward and accurate when the number of replicate measurements is large, however, a Monte Carlo study showed it to be problematic for the actual number of replicate measurements (median from 3 to 4). Also, it is sometimes important to characterize the uncertainty of a single urine measurement. Therefore this alternate method has been developed. A method of parameterizing the uncertainty of Mayak urine bioassay measmements is described. The Poisson lognormal model is assumed and data from 63 cases (1099 urine measurements in all) are used to empirically determine the lognormal normalization uncertainty, given the measurement uncertainties obtained from count quantities. The natural logarithm of the geometric standard deviation of the normalization uncertainty is found to be in the range 0.31 to 0.35 including a measurement component estimated to be 0.2.

61 RADIATION PROTECTION AND DOSIMETRY↗

Retrieval of energy spectra for all flavours of neutrinos from core-collapse supernova with multiple detectors

ABSTRACT We present a new method by which to retrieve energy spectrum for all falvours of neutrinos from core-collapse supernova (CCSN). In the retrieval process, we do not assume any analytic formulas to express the energy spectrum of neutrinos but rather take a direct way of spectrum reconstruction from the observed data; the singular value decomposition algorithm with a newly developed adaptive energy-gridding technique is adopted. We employ three independent reaction channels having different flavour sensitivity to neutrinos. Two reaction channels, inverse beta decay on proton and elastic scattering on electrons, from a water Cherenkov detector such as Super-Kamiokande (SK) and Hyper-Kamiokande (HK), and a charged current reaction channel with Argon from the Deep Underground Neutrino Experiment (DUNE) are adopted. Given neutrino oscillation models, we iteratively search the neutrino energy spectra at the CCSN source until they provide the consistent event counts in the three reaction channels. We test the capability of our method by demonstrating the spectrum retrieval to a theoretical neutrino data computed by our recent three-dimensional CCSN simulation. Although the energy spectrum with either electron-type or electron-type antineutrinos at the CCSN source has relatively large error compared to that of other species, the joint analysis with HK + DUNE or SK + DUNE will provide precise energy spectrum of all flavours of neutrinos at the source. Finally, we discuss perspectives for improvements of our method by using neutrino data of other detectors.

79 ASTRONOMY AND ASTROPHYSICS↗

Diffuse γ-ray emission from misaligned active galactic nuclei

Active galactic nuclei (AGNs) with jets seen at small viewing angles are the most luminous and abundant objects in the γ-ray sky. AGNs with jets misaligned along the line of sight appear fainter in the sky but are more numerous than the brighter blazars. We calculate the diffuse γ-ray emission due to the population of misaligned AGNs (MAGNs) unresolved by the Large Area Telescope (LAT) on the Fermi Gamma-ray Space Telescope (Fermi). A correlation between the γ-ray luminosity and the radio-core luminosity is established and demonstrated to be physical by statistical tests, as well as compatible with upper limits based on Fermi-LAT data for a large sample of radio-loud MAGNs. We constrain the derived γ-ray luminosity function by means of the source-count distribution of the radio galaxies detected by the Fermi-LAT. We finally calculate the diffuse γ-ray flux due to the whole MAGN population. Our results demonstrate that MAGNs can contribute from 10% up to nearly the entire measured isotropic gamma-ray background. We evaluate a theoretical uncertainty on the flux of almost an order of magnitude.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigation of EMIC wave scattering as the cause for the BARREL 17 January 2013 relativistic electron precipitation event: A quantitative comparison of simulation with observations

Electromagnetic ion cyclotron (EMIC) waves were observed at multiple observatory locations for several hours on 17 January 2013. During the wave activity period, a duskside relativistic electron precipitation (REP) event was observed by one of the Balloon Array for Radiation belt Relativistic Electron Losses (BARREL) balloons and was magnetically mapped close to Geostationary Operational Environmental Satellite (GOES) 13. We simulate the relativistic electron pitch angle diffusion caused by gyroresonant interactions with EMIC waves using wave and particle data measured by multiple instruments on board GOES 13 and the Van Allen Probes. We show that the count rate, the energy distribution, and the time variation of the simulated precipitation all agree very well with the balloon observations, suggesting that EMIC wave scattering was likely the cause for the precipitation event. The event reported here is the first balloon REP event with closely conjugate EMIC wave observations, and our study employs the most detailed quantitative analysis on the link of EMIC waves with observed REP to date.

58 GEOSCIENCES↗

Note: Spectrometer with multichannel photon-counting detector for beam emission spectroscopy in magnetic fusion devices

A spectrometer based on a linear array photomultiplier tube (PMT) has been developed and calibrated. A 0.635 m focal length Czerny-Turner monochromator combined with a coupling optics provides an image of a narrow 0.5 nm spectral range with a resolution of 0.015 nm/channel on a 32-anode PMT. The system aims at spectroscopy of D{sub α} or H{sub α} lines emitted by a diagnostic atomic beam in a plasma (primarily a motional Stark effect diagnostics). To record a low photon flux of ∼10{sup 6} s{sup −1} per channel with the time resolution of 100 μs, a pulse counting approach has been used. Wideband amplifiers scale single-electron pulses and transmit them to a digital data processing core hardwired in a programmable logic matrix. Calibrations have shown that the aberration-limited instrument function fits to a single detector channel of 1 mm width. Pilot results of passive measurements of D{sub α} light emission from the plasma confined in a magnetic trap are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lower limits on the anisotropy of the extragalactic gamma-ray background implied by the 2FGL and 1FHL catalogs

In principle, the angular anisotropy in the extragalactic gamma-ray background (EGRB) places severe constraints upon putative populations of unresolved gamma-ray point sources. Existing estimates of the EGRB anisotropy have been constructed by excising known point sources, e.g., taken from the First or Two Year Fermi-LAT Source Catalog (1FGL or 2FGL, respectively) and statistically analyzing the residual gamma-ray sky maps. We perform an independent check of the EGRB anisotropy limits by comparing the values obtained from the 1FGL-masked sky maps to the signal implied by sources that lie below the 1FGL detection threshold in the more sensitive 2FGL and 1FHL (First Fermi-LAT catalog of >10 GeV sources). As such, our analysis provides an internal consistency check of implications for source counts and spectral index distributions of gamma-ray bright active galactic nuclei obtained from Fermi-LAT data. Based on this, we find evidence for substantially larger anisotropies than those previously reported at energies above 5 GeV, where BL Lac objects are likely to provide the bulk of their contribution to the EGRB. This uncertainty in the EGRB anisotropy cautions against using it as an independent constraint for the high-redshift gamma-ray universe. Moreover, this would suggest that contrary to previous claims, smooth extensions of the resolved point-source population may be able to simultaneously explain both the isotropic and anisotropic components of the EGRB.

79 ASTRONOMY AND ASTROPHYSICS↗

Application of pixel array detectors at x-ray synchrotrons.

Pixel array detectors have only recently been seriously used at x-ray synchrotrons. We describe the application of a digital pixel array detector (Pilatus100k) to a variety of synchrotron experiments at the Advanced Photon Source at Argonne National Laboratory. The Pilatus100k was developed at the Paul Scherrer Institut (PSI). It has been commercialized by a PSI spinoff (Dectrics Ltd.) This is the first commercially available pixel array detector for x-ray synchrotron applications. The APS synchrotron provides tunable x-ray pulses with duration of {approx}80 ps and a repetition period of 153 ns (24-bunch mode). The Pilatus100k is a direct detection x-ray detector where each 172 micron pixel counts individual x-ray pulses above a lower threshold. It consists of {approx}100k pixels each of which is capable of single-photon counting (>3 keV) at count rates up to {approx}1 MHz. In addition, the Pilatus100k is an electronically gateable detector. We present data showing that the Pilatus100k is capable of isolating a single x-ray bunch at the APS in 24 bunch mode. We will also present a variety of different experiments exploiting the unique capabilities of the Pilatus100k.

43 PARTICLE ACCELERATORS↗

Graph Algorithms in PGAS: Chapel and UPC++

The Partitioned Global Address Space (PGAS) programming model can be implemented «««< HEAD either with programming language features or with runtime library APIs, each implementation favoring different aspects (e.g., productivity, abstraction, flexibility, or performance). Certain language and runtime features, such as collectives, explicit and asynchronous communication primitives, and constructs facilitating overlap of communication and computation (such as futures and conjoined futures) can enable better performance and scaling for irregular applications, in particular for distributed graph analytics. We compare graph algorithms in one of each of these environments: the Chapel PGAS programming language and the UPC++ PGAS runtime library. We implement algorithms for breadth-first search and triangle counting graph kernels in both environments. We discuss the code in each of the environments, and compile performance data on a Cray Aries and an Infiniband platform. Our results show that the library-based approach of UPC++ currently provides strong performance while Chapel provides a high-level abstraction that, harder to optimize, still provides comparable performance. We argue that various language primitives and runtime library features should be considered in conjunction with each other to design future graph analytics libraries so as to incorporate the best of both worlds.

Distributed Algorithms, Graph algorithms, HPC↗

Optimization of oncological {sup 18}F-FDG PET/CT imaging based on a multiparameter analysis

Purpose: This paper describes a method to achieve consistent clinical image quality in {sup 18}F-FDG scans accounting for patient habitus, dose regimen, image acquisition, and processing techniques. Methods: Oncological PET/CT scan data for 58 subjects were evaluated retrospectively to derive analytical curves that predict image quality. Patient noise equivalent count rate and coefficient of variation (CV) were used as metrics in their analysis. Optimized acquisition protocols were identified and prospectively applied to 179 subjects. Results: The adoption of different schemes for three body mass ranges (<60 kg, 60–90 kg, >90 kg) allows improved image quality with both point spread function and ordered-subsets expectation maximization-3D reconstruction methods. The application of this methodology showed that CV improved significantly (p < 0.0001) in clinical practice. Conclusions: Consistent oncological PET/CT image quality on a high-performance scanner was achieved from an analysis of the relations existing between dose regimen, patient habitus, acquisition, and processing techniques. The proposed methodology may be used by PET/CT centers to develop protocols to standardize PET/CT imaging procedures and achieve better patient management and cost-effective operations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Long term occupancy estimation in a commercial space: an empirical study: poster abstract

Understanding occupancy patterns in a building is very useful to control HVAC systems for improving energy efficiency of the building and occupant comfort. There has been a very little attempt to understand long term occupancy patterns in a commercial space. In this work, we leverage depth sensors (Kinect for XBOX One) to collect occupancy count from an 11,000 square foot commercial space (Bosch office) for nine months. We analyze the collected data and describe key findings that provide deep insights about how a commercial space is used and serve as a guideline to formulate novel and efficient control strategies.

Liu, Kin Sum↗