Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Verification Survey Report of the South Waste Tank Farm Training/Test Tower and hazardous Waste Storage Lockers at the West Valley Demonstration Project, West Valley, New York (Final Report)

A team from ORAU's Independent Environmental Assessment and Verification Program performed verification survey activities on the South Test Tower and four Hazardous Waste Storage Lockers. Scan data collected by ORAU determined that both the alpha and alpha-plus-beta activity was representative of radiological background conditions. The count rate distribution showed no outliers that would be indicative of alpha or alpha-plus-beta count rates in excess of background. It is the opinion of ORAU that independent verification data collected support the site's conclusions that the South Tower and Lockers sufficiently meet the site criteria for release to recycle and reuse.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

xxing9703/PAVE

Untargeted metabolomics can detect more than 10 000 peaks in a single LC–MS run. The correspondence between these peaks and metabolites, however, remains unclear. Here, we introduce a Peak Annotation and Verification Engine (PAVE) for annotating untargeted microbial metabolomics data. The workflow involves growing cells in 13C and 15N isotope-labeled media to identify peaks from biological compounds and their carbon and nitrogen atom counts. Improved deisotoping and deadducting are enabled by algorithms that integrate positive mode, negative mode, and labeling data. To distinguish metabolites and their fragments, PAVE experimentally measures the response of each peak to weak in-source collision induced dissociation, which increases the peak intensity for fragments while decreasing it for their parent ions. The molecular formulas of the putative metabolites are then assigned based on database searching using both m/z and C/N atom counts. Application of this procedure to Saccharomyces cerevisiae and Escherichia coli revealed that more than 80% of peaks do not label, i.e., are environmental contaminants. More than 70% of the biological peaks are isotopic variants, adducts, fragments, or mass spectrometry artifacts yielding ∼2000 apparent metabolites across the two organisms. About 650 match to a known metabolite formula based on m/z and C/N atom counts, with 220 assigned structures based on MS/MS and/or retention time to match to authenticated standards. Thus, PAVE enables systematic annotation of LC–MS metabolomics data with only ∼4% of peaks annotated as apparent metabolites.

Xing, Xi↗

THE ARCONS PIPELINE: DATA REDUCTION FOR MKID ARRAYS

The Array Camera for Optical to Near-IR Spectrophotometry, or ARCONS, is a camera based on Microwave Kinetic Inductance Detectors (MKIDs), a new technology that has the potential for broad application in astronomy. Using an array of MKIDs, the instrument is able to produce time-resolved imaging and low-resolution spectroscopy constructed from detections of individual photons. The arrival time and energy of each photon are recorded in a manner similar to X-ray calorimetry, but at higher photon fluxes. The technique works over a very large wavelength range, is free from fundamental read noise and dark-current limitations, and provides microsecond-level timing resolution. Since the instrument reads out all pixels continuously while exposing, there is no loss of active exposure time to readout. The technology requires a different approach to data reduction compared to conventional CCDs. Here we outline here the prototype data reduction pipeline developed for ARCONS, though many of the principles are also more broadly applicable to energy-resolved photon counting arrays (e.g., transition edge sensors, superconducting tunnel junctions). We describe the pipeline's current status, and the algorithms and techniques employed in taking data from the arrival of photons at the MKID array to the production of images, spectra, and time-resolved light curves.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A portable high-field pulsed-magnet system for single-crystal x-ray scattering studies

We present a portable pulsed-magnet system for x-ray studies of materials in high magnetic fields (up to 30 T). The apparatus consists of a split-pair of minicoils cooled on a closed-cycle cryostat, which is used for x-ray diffraction studies with applied field normal to the scattering plane. A second independent closed-cycle cryostat is used for cooling the sample to near liquid helium temperatures. Pulsed magnetic fields ({approx}1 ms in total duration) are generated by discharging a configurable capacitor bank into the magnet coils. Time-resolved scattering data are collected using a combination of a fast single-photon counting detector, a multichannel scaler, and a high-resolution digital storage oscilloscope. The capabilities of this instrument are used to study a geometrically frustrated system revealing strong magnetostrictive effects in the spin-liquid state.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A SWIFT SURVEY OF ACCRETION ONTO STELLAR-MASS BLACK HOLES

We present a systemic analysis of all of the stellar-mass black hole binaries (confirmed and candidate) observed by the Swift observatory up to 2010 June. The broad Swift bandpass enables a trace of disk evolution over an unprecedented range in flux and temperature. The final data sample consists of 476 X-ray spectra containing greater than 100 counts, in the 0.6-10 keV band. This is the largest sample of high-quality CCD spectra of accreting black holes published to date. In addition, strictly simultaneous data at optical/UV wavelengths are available for 255 (54%) of these observations. The data are modeled with a combination of an accretion disk and a hard spectral component. For the hard component we consider both a simple power-law model and a thermal Comptonization model. An accretion disk is detected at greater than the 5{sigma} confidence level in 61% of the observations. Light curves and color-color diagrams are constructed for each system. Hardness-luminosity and disk fraction-luminosity diagrams are constructed and are observed to be consistent with those typically observed by RXTE, noting the sensitivity below 2 keV provided by Swift. The observed spectra have an average luminosity of {approx}1% Eddington, though we are sensitive to accretion disks down to a luminosity of 10{sup -3} L{sub Edd}. Thus, this is also the largest sample of such cool accretion disks studied to date. The accretion disk temperature distribution displays two peaks consistent with the classical hard and soft spectral states, with a smaller number of disks distributed between these. The distribution of inner disk radii is observed to be continuous regardless of which model is used to fit the hard continua. There is no evidence for large-scale truncation of the accretion disk in the hard state (at least for L{sub x} {approx}> 10{sup -3} L{sub Edd}), with all of the accretion disks having radii {approx}< 40 R{sub g} . Plots of the accretion disk inner radius versus hardness ratio reveal the disk radius to be decreasing as the spectrum hardens, i.e., enters the hard state. This is in contrast to expectations from the standard disk truncation paradigm and points toward a contribution from spectral hardening. The availability of simultaneous X-ray and optical/UV data for a subset of observations facilitates a critical examination of the role of disk irradiation via a modified disk model with a variable emissivity profile (i.e., T(r){proportional_to}r {sup -p}). The broadband spectra (X-ray-optical/UV) reveal irradiation of the accretion disk to be an important effect at all luminosities sampled herein, i.e., p {approx}< 0.75 for luminosities {approx}> 10{sup -3} L{sub Edd}. The accretion disk is found to dominate the UV emission irrespective of the assumed hard spectral component. Overall, we find the broadband soft-state spectra to be consistent with an irradiated accretion disk plus a corona, but we are unable to make conclusive statements regarding the nature of the hard-state accretion flow (e.g., ADAF/corona versus jet). Finally, the Swift data reveal a relation between the flux emitted by the accretion disk and that emitted by the corona, for this sample of stellar-mass black holes, that is found to be in broad agreement with the observed disk-corona relationship in Seyfert galaxies, suggesting a scale invariant coupling between the accretion disk and the corona.

79 ASTRONOMY AND ASTROPHYSICS↗

The galaxy distribution and the large-scale structure of the universe

Data related to the large-scale galaxy distribution are discussed. The galaxy counts of Shane-Wirtanen (1967) are analyzed; the effects of residual systematic errors on the galaxy distribution measurements are considered. The analysis reveals that the Shane-Wirtanen data are not applicable to the study of large-scale structure. A model which is capable of measuring galaxy correlation functions on scales greater than about 10 Mpc is evaluated.

Geller, M. J.↗

Study of Pile-Up Effects in Decay Energy Spectroscopy

Pile-up is an unavoidable complication for cryogenic detectors with relatively large heat capacities and slow rise time, such as systems for decay energy spectroscopy employing large Au absorbers. We have simulated the spectral response of such slow cryogenic detectors using Monte-Carlo algorithms to investigate the effects of pile-up on absolute and relative activity measurements. We focus on the impact of non-distinguishable pile-up that occurs when the rising edges of two waveforms originating from different events overlap in time and are interpreted as a single event. This effect can not be readily identified and corrected in experimental data. We investigated two representative cases of absolute decay counting and plutonium isotopic analysis and find that pile-up can distort the reconstruction of both the absolute and relative activities. This Monte-Carlo methodology quantifies of pile-up effects and provides a systematic methodology for calculating corrective factors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Outcomes of Chemoradiotherapy With 5-Fluorouracil and Mitomycin C for Anal Cancer in Immunocompetent Versus Immunodeficient Patients

Purpose: Information is limited as to how we should treat invasive anal squamous cell carcinoma (SCC) in patients with chronic immunosuppression, since the majority of clinical studies to date have excluded such patients. The objective of this study is to compare treatment outcomes in immunocompetent (IC) versus immunodeficient (ID) patients with invasive anal SCC treated similarly with combined modality therapy. Methods and Materials: Between January 1999 and March 2007, a total of 36 consecutive IC and ID patients received concurrent chemoradiotherapy using three-dimensional conformal radiotherapy with infusional 5-fluorouracil and mitomycin C. The IC and ID groups consisted of 19 and 17 patients, respectively, with 14 human immunodeficiency virus-positive (HIV+) and 3 post-solid organ transplant ID patients. There were no significant differences in tumor size, T stage, N stage, chemotherapy doses, or radiation doses between the two groups. Results: With a median follow-up of 3.1 years, no differences were found in overall survival, disease-specific survival, and colostomy-free survival. Three-year overall survival was 83.6% (95% CI = 68.2-100) and 91.7% (95% CI = 77.3-100) in the IC and ID groups, respectively. In addition, there were no differences in acute and late toxicity profiles between the two groups. In the human immunodeficiency virus-positive patients, Cox modeling showed no difference in overall survival by pretreatment CD4 counts (hazard ratio = 0.994, 95% CI = 0.98-1.01). No correlation was found between CD4 counts and the degree of acute toxicities. Conclusion: Our data suggest that standard combined modality therapy with three-dimensional conformal radiotherapy and 5-fluorouracil plus mitomycin C is as safe and effective for ID patients as for IC patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Systematic measurement of fast neutron background fluctuations in an urban area using a mobile detection system

Neutron background measurements using a mobile trailer-based system were conducted in Knoxville, Tennessee. The 0.5 m 2 system consisting of 8 EJ-301 liquid scintillation detectors was used to collect neutron background measurements in order to better understand the systematic background variations that depend solely on the street-level measurement position in a local, downtown area. Data was collected along 5 different streets in the downtown Knoxville area, and the measurements were found to be repeatable. Using 10-min measurements, fractional uncertainty in each measured data point was <2%. Compared with fast neutron background count rates measured away from downtown Knoxville, a reduction in background count rates ranging from 10-50% was observed in the downtown area, sometimes varying substantially over distances of tens of meters. These reductions are attributed to the shielding of adjacent buildings, quantified in part here by the metric angle-of-open-sky. The adjacent buildings may serve to shield cosmic ray neutron flux.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative Fluorescence Microscopy To Determine Molecular Occupancy of Phospholipid Vesicles

Encapsulation of molecules in phospholipid vesicles provides unique opportunities to study chemical reactions in small volumes as well as the behavior of individual proteins, enzymes, and ribozymes in a confined region without requiring a tether to immobilize the molecule to a surface. These experiments generally depend on generating a predictable loading of vesicles with small numbers of target molecules and thus raise a significant measurement challenge, namely, to quantify molecular occupancy of vesicles at the single-molecule level. In this work, we describe an imaging experiment to measure the time-dependent fluorescence from individual dye molecules encapsulated in ~130 nm vesicles that are adhered to a glass surface. For determining a fit of the molecular occupancy data to a Poisson model, it is critical to count empty vesicles in the population since these dominate the sample when the mean occupancy is small, λ ≤ ~1. Counting empty vesicles was accomplished by subsequently labeling all the vesicles with a lipophilic dye and reimaging the sample. By counting both the empty vesicles and those containing fluors, and quantifying the number of fluors present, we demonstrate a self-consistent Poisson distribution of molecular occupancy for well-solvated molecules, as well as anomalies due to aggregation of dye, which can arise even at very low solution concentrations. Here, by observation of many vesicles in parallel in an image, this approach provides quantitative information about the distribution of molecular occupancy in a population of vesicles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

RINGS AND RADIAL WAVES IN THE DISK OF THE MILKY WAY

Here, we show that in the anticenter region, between Galactic longitudes of 110° < l < 229°, there is an oscillating asymmetry in the main-sequence star counts on either side of the Galactic plane using data from the Sloan Digital Sky Survey. This asymmetry oscillates from more stars in the north at distances of about 2 kpc from the Sun to more stars in the south at 4–6 kpc from the Sun to more stars in the north at distances of 8–10 kpc from the Sun. We also see evidence that there are more stars in the south at distances of 12–16 kpc from the Sun. The three more distant asymmetries form roughly concentric rings around the Galactic center, opening in the direction of the Milky Way's spiral arms. The northern ring, 9 kpc from the Sun, is easily identified with the previously discovered Monoceros Ring. Parts of the southern ring at 14 kpc from the Sun (which we call the TriAnd Ring) have previously been identified as related to the Monoceros Ring, and others have been called the Triangulum Andromeda Overdensity. The two nearer oscillations are approximated by a toy model in which the disk plane is offset by the order of 100 pc up and then down at different radii. We also show that the disk is not azimuthally symmetric around the Galactic anticenter and that there could be a correspondence between our observed oscillations and the spiral structure of the Galaxy. Lastly, our observations suggest that the TriAnd and Monoceros Rings (which extend to at least 25 kpc from the Galactic center) are primarily the result of disk oscillations.

79 ASTRONOMY AND ASTROPHYSICS↗

Super-Resolution Ptychography with Small Segmented Detectors

To overcome the spatial resolution limit set by aperture-limited diffraction in traditional scanning transmission electron microscopy, microscopists have developed ptychography enabled by iterative phase retrieval algorithms and high-dynamic-range pixel array detectors. Current detector designs are limited by the data rate off chip, so a high-pixel-count detector has a proportionally lower frame rate than the few-segment detectors used for differential phase contrast (DPC) imaging. This slower acquisition speed leads to heightened vulnerability to scan noise, drift, and potential sample damage. This creates opportunities for repurposing fast segmented detectors for ptychography by trading a reduction in reciprocal space pixels for an increase in real space pixels. Here, we explore a strategy of oversampling in real space and instead apply detector pixel upsampling during the reconstruction process. Further, we demonstrate the viability of achieving super-resolution ptychography on thin objects using only 2 × 2 detector pixels, surpassing the resolution of integrated DPC (iDPC) imaging. With optimization using simulated datasets and experiments on MoTe 2 /WSe 2 bilayer moiré superlattices, we achieved super-resolution ptychography reconstructions under rapid acquisition conditions (37.5 pA, 1 μs dwell time), yielding over 50% improvements in contrast and information limit compared to annular dark field and iDPC imaging on the same detectors.

2D materials↗

Twenty-four Years of Follow-Up for a Hanford Plutonium Wound Case

A 1985 plutonium puncture wound resulted in the initial deposition of 48 kBq of transuranic alpha activity, primarily 239Pu and 241Am, in a worker’s right index finger. Surgical excisions in the week following reduced the long-term residual wound activity to 5.4 kBq, and 164 DTPA chelation therapy administrations over a 17-month period resulted in urinary excretion of about 7 kBq. The case was published in 1988, but now 20 additional years of follow-up data are available. Annual bioassay measurements have included wound counts, skeleton counts, liver counts, lung counts, axillary lymph node counts, and urinalyses for plutonium and 241Am. These measurements have shown relatively stable levels of 241Am at the wound site, with gradually increasing amounts of 241Am detected in the skeleton. Liver counts has shown erratic detection of 241Am, and lung counts indicate 241Am as shine from the axillary lymph nodes and skeleton. Urine excretion of 239Pu since termination of chelation therapy has typically ranged from 10 to 20 mBq d-1, with 241Am excretion being about 10% of that for 239Pu. In addition, the worker has undergone annual routine medical exams, which have not identified any adverse health effects associated with the intake.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Ab initio electroweak corrections to superallowed β decays and their impact on V ud

Radiative corrections are essential for an accurate determination of V ud from superallowed β decays. In view of recent progress in the single-nucleon sector, the uncertainty is dominated by the theoretical description of nucleus-dependent effects, limiting the precision that can currently be achieved for V ud . In this work, we provide a detailed account of the electroweak corrections to superallowed β decays in effective field theory (EFT), including the power counting, potential and ultrasoft contributions, and factorization in the decay rate. Here, we present a first numerical evaluation of the dominant corrections in light nuclei based on quantum Monte Carlo methods, confirming the expectations from the EFT power counting. Finally, we discuss strategies how to extract from data the low-energy constants that parametrize short-distance contributions and whose values are not predicted by the EFT. Combined with advances in ab initio nuclear-structure calculations, this EFT framework allows one to systematically address the dominant uncertainty in V ud , as illustrated in detail for the 14 O → 14 N transition.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Limits on the Existence of sub-MeV Sterile Neutrinos from the Decay of 7 Be in Superconducting Quantum Sensors

Sterile neutrinos are natural extensions to the standard model of particle physics and provide a possible portal to the dark sector. We report a new search for the existence of sub-MeV sterile neutrinos using the decay-momentum reconstruction technique in the decay of 7 Be. The experiment measures the total energy of the 7 Li daughter atom from the electron capture decay of 7 Be implanted into sensitive superconducting tunnel junction (STJ) quantum sensors. Here, this first experiment presents data from a single STJ operated at a low count rate for a net total of 28 days, and provides exclusion limits on sterile neutrinos in the mass range from 100 to 850 keV that improve upon previous work by up to an order of magnitude.

42 ENGINEERING↗

Improved Zika virus plaque assay using Vero/TMPRSS2 cell line

Plaque assay is the gold standard for the quantification of viable cytopathic viruses like Zika virus (ZIKV). Some strains of ZIKV produce plaques that are very difficult to accurately visualize and count on the commonly used Vero cell line. From data generated in our lab, we became curious if Vero/TMPRSS2 cells may be a better alternative; therefore, we compared the plaque forming units of two strains of ZIKV on Vero/TMPRSS2 cells to those produced by Vero cells. We also compared the virus stock titer generated on Vero/TMPRSS2 cells to that generated by the Vero cell line. Although the Vero cells generated higher quantity of ZIKV stocks, the Vero/TMPRSS2 cells produced plaques with significantly improved morphology and visibility and may, therefore, be a better alternative to use for performing plaque assays for strains of ZIKV that are more difficult to titer on regular Vero cells.

60 APPLIED LIFE SCIENCES↗

AGR-3/4 Final Data Qualification Report for ATR Cycles 151A through 155B-1

This report provides the qualification status of experimental data for the entire Advanced Gas Reactor 3/4 (AGR 3/4) fuel irradiation. AGR-3/4 is the third in a series of planned irradiation experiments conducted in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) for the AGR Fuel Development and Qualification Program, which supports development of the advanced reactor technology under the INL ART Technology Development Office (TDO). The main objective of AGR-3/4 irradiation is to provide a known source of fission products for subsequent transport through compact matrix and structural graphite materials due to the presence of designed-to-fail fuel particles. Full power irradiation of the AGR 3/4 test began on December 14, 2011 (ATR Cycle 151A), and was completed on April 12, 2014 (end of ATR Cycle 155B) after 369.1 effective full power days of irradiation. The AGR-3/4 test was in the reactor core for eight of the ten ATR cycles between 151A and 155B. During the unplanned outage cycle, 153A, the experiment was removed from the ATR northeast flux trap (NEFT) location and stored in the ATR canal. This was to prevent overheating of fuel compacts due to higher than normal ATR power during the subsequent Powered Axial Locator Mechanism cycle, 153B. The AGR 3/4 test was inserted back into the ATR NEFT location during the outage of ATR Cycle 154A on April 26, 2013. Therefore, the AGR-3/4 irradiation data received during these 2 cycles (153A and 153B) are irrelevant and their qualification status isnot included in this report. Additionally, during ATR Cycle 152A the ATR core ran at low power for a short enough duration that the irradiation data are not used for physics and thermal calculations. However, the qualification status of irradiation data for this cycle is still covered in this report. As a result, this report includes data from 8 ATR Cycles: 151A, 151B, 152A, 152B, 154A, 154B, 155A, and 155B, as recorded in the Nuclear Data Management and Analysis System (NDMAS). The AGR 3/4 data streams addressed in this report include thermocouple (TC) temperatures, sweep gas data (flow rates, pressure, and moisture content), and Fission Product Monitoring System (FPMS) data (release rates, release to birth rate ratios [R/Bs], and particle failure counts) for each of the twelve capsules in the AGR 3/4 experiment. During Outage Cycle 155A, fourteen flow meters were installed downstream from fourteen FPMS monitors to measure flows from the monitors; qualification status of these data are also included in the report. The final data qualification status for these data streams is determined by a Data Review Committee (DRC) composed of AGR technical leads, Sitewide Quality Assurance (QA), and NDMAS analysts. For ATR Cycles 151A through 154B, the DRC convened on February 12, 2014, reviewed the data acquisition process, and considered whether the data met the requirements for data collection as specified in QA approved INL ART TDO data collection plans. The DRC also examined the results of NDMAS data testing and statistical analyses, and confirmed the qualification status of the data as given in this report. The qualification status of AGR-3/4 irradiation data during the first six cycles were previously reported in INL/EXT-14-31186 document. This report presents data qualification status for the entire AGR-3/4 irradiation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Utilization of the Differential Die-Away Self-Interrogation Technique for Characterization and Verification of Spent Nuclear Fuel

New nondestructive assay techniques are sought to better characterize spent nuclear fuel. One of the NDA instruments selected for possible deployment is differential die-away self-interrogation (DDSI). The proposed DDSI approach for spent fuel assembly assay utilizes primarily the spontaneous fission and (α, n) neutrons in the assemblies as an internal interrogating radiation source. The neutrons released in spontaneous fission or (α,n) reactions are thermalized in the surrounding water and induce fission in fissile isotopes, thereby creating a measurable signal from isotopes of interest that would be otherwise difficult to measure. The DDSI instrument employs neutron coincidence counting with 3He tubes and list-mode-based data acquisition to allow for production of Rossi-alpha distributions (RADs) in post-processing. The list-mode approach to data collection and subsequent construction of RADs has expanded the analytical possibilities, as will be demonstrated throughout this thesis. One of the primary advantages is that the measured signal in the form of a RAD can be analyzed in its entirety including determination of die-away times in different time domains. This capability led to the development of the early die-away method, a novel leakage multiplication determination method which is tested throughout the thesis on different sources in simulation space and fresh fuel experiments. The early die-away method is a robust, accurate, improved method of determining multiplication without the need for knowledge of the (α,n) source term. The DDSI technique and instrument are presented along with the many novel capabilities enabled by and discovered through RAD analysis. Among the new capabilities presented are the early die-away method, total plutonium content determination, and highly sensitive missing pin detection. Simulation of hundreds of different spent and fresh fuel assemblies were used to develop the analysis algorithms and the techniques were tested on a variety of spontaneous fission-driven fresh fuel assemblies at Los Alamos National Laboratory and the BeRP ball at the Nevada National Security Site. The development of the new, improved analysis and characterization methods with the DDSI instrument makes it a viable technique for implementation in a facility to meet material control and safeguards needs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗