Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coherent radiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Snowmass 2021 Scintillating Bubble Chambers: Liquid-noble Bubble Chambers for Dark Matter and CE$\nu$NS Detection

The Scintillating Bubble Chamber (SBC) Collaboration is developing liquid-noble bubble chambers for the quasi-background-free detection of low-mass (GeV-scale) dark matter and coherent scattering (CE$\nu$NS) of low-energy (MeV-scale) neutrinos. The first physics-scale demonstrator of this technique, a 10-kg liquid argon bubble chamber dubbed SBC-LAr10, is now being commissioned at Fermilab. This device will calibrate the background discrimination power and sensitivity of superheated argon to nuclear recoils at energies down to 100 eV. A second functionally-identical detector with a focus on radiopure construction is being built for SBC's first dark matter search at SNOLAB. The projected spin-independent sensitivity of this search is approximately $10^{-43}$ cm$^2$ at 1 GeV$/c^2$ dark matter particle mass. The scalability and background discrimination power of the liquid-noble bubble chamber make this technique a compelling candidate for future dark matter searches to the solar neutrino fog at 1 GeV$/c^2$ particle mass (requiring a $\sim$ton-year exposure with non-neutrino backgrounds sub-dominant to the solar CE$\nu$NS signal) and for high-statistics CE$\nu$NS studies at nuclear reactors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic Misalignment of Interstellar Dust Filaments

We present evidence for scale-independent misalignment of interstellar dust filaments and magnetic fields. We estimate the misalignment by comparing millimeter-wave dust-polarization measurements from Planck with filamentary structures identified in neutral-hydrogen (H I ) measurements from H I 4PI. We find that the misalignment angle displays a scale independence (harmonic coherence) for features larger than the H I 4PI beamwidth (16$\acute{.}$2). We additionally find a spatial coherence on angular scales of ${ \mathcal O }(1^\circ )$. We present several misalignment estimators formed from the auto- and cross-spectra of dust-polarization and H I -based maps, and we also introduce a map-space estimator. Applied to large regions of the high-Galactic-latitude sky, we find a global misalignment angle of ~2°, which is robust to a variety of masking choices. By dividing the sky into small regions, we show that the misalignment angle correlates with the parity-violating TB cross-spectrum measured in the Planck dust maps. The misalignment paradigm also predicts a dust EB signal, which is of relevance in the search for cosmic birefringence but as yet undetected; the measurements of EB are noisier than those of TB, and our correlations of EB with misalignment angle are found to be weaker and less robust to masking choices. We also introduce an H I -based dust-polarization template constructed from the Hessian matrix of the H I intensity, which is found to correlate more strongly than previous templates with Planck dust B modes.

79 ASTRONOMY AND ASTROPHYSICS↗

All hard X-ray transient grating spectroscopy

Optical-domain transient grating (TG) spectroscopy is the ideal tool to investigate transport phenomena in gases, liquids and solids, but it is limited to typically micron-size grating periods. Extreme-Ultraviolet TG has represented a major leap forward to access the mesoscopic scales. Hard X-ray TGs open access in principle to the nanoscale. Hard X-ray TGs were recently generated using the Talbot effect and probed by optical pulses, but these hinder exploiting the advantages of the nanoscale gratings. Here, we present an all-X-ray TG study, in which few-femtosecond hard X-ray pulses are used both for excitation and probing. Our experiment was performed on an amorphous film of an FeGd alloy and on a thin silicon single crystal. The results show a manifestation of the TG induced by the X-ray pump and probe pulses in the form of Talbot carpets, as well as temporal evolution of the grating in crystalline silicon showing coherent optical phonons. Ultrafast all-X-ray TG spectroscopy has the potential to study fundamental excitations with femtosecond time resolution and nanometer spatial sensitivity.

Ferrari, Eugenio [Deutsches Elektronen-Synchrotron↗

Toward fully coherent soft x-ray free-electron laser via echo-enabled harmonic generation in fourth generation synchrotron light sources

Having previously reported on bunching via echo-enabled harmonic generation (EEHG) as an effective way to improve the longitudinal coherence in the NSLS-II storage ring [X. Yang et al., Sci. Rep. 12, 9437 (2022)], we demonstrate that this EEHG scheme can be easily adopted to any fourth generation diffraction-limited synchrotron light source with significant benefits. The advantage of the scheme is that it requires no change of the lattice and is fully compatible with other beamlines. Since the EEHG performance is mainly determined by the momentum compaction, beam emittances, and beta functions of a SR lattice, we have identified these crucial parameters and successfully built a generalized model, which can predict the performance of nearly any SLS. Regarding the fourth generation SLSs, momentum compactions are often significantly smaller; thus, to cover the x rays with a photon energy of up to 1 keV, we utilize a specific design, including a 250 nm seed-laser wavelength. Our model predicts that for most of the current and future fourth generation SLSs, the EEHG scheme can produce significant prebunching up to harmonic 200 and, thus, generate a few MW scale peak power at 1.25 nm wavelength.

47 OTHER INSTRUMENTATION↗

Spectroscopic Study of Solar Transition Region Oscillations in the Quiet-Sun Observed By IRIS Using Si IV Spectral Line

In the present paper, we use Si IV 1393.755 Å spectral line observed by the Interface Region Imaging Spectrograph (IRIS) in the quiet-Sun to determine physical nature of the solar transition region (TR) oscillations. We analyze the properties of these oscillations using wavelet tools (e.g., power, cross-power, coherence, and phase difference) along with the stringent noise model (i.e., power-law + constant). We estimate the period of the intensity and Doppler velocity oscillations at each chosen location in the quiet-Sun (QS) and quantify the distribution of the statistically significant power and associated periods in one bright and two dark regions. In the bright TR region, the mean periods in intensity and velocity are 7 min, and 8 min respectively. In the dark region, the mean periods in intensity and velocity are 7 min, and 5.4 min respectively. We also estimate the phase difference between the intensity and Doppler velocity oscillations at each location. The statistical distribution of phase difference is estimated, which peaks at -119°± 13°, 33°± 10°, 102°± 10° in the bright region, while at -153°± 13°, 6°± 20°, 151°± 10° in the dark region. The statistical distribution reveals that the oscillations are caused by propagating slow magnetoacoustic waves encountered with the TR. Some of these locations may also be associated with the standing slow waves. Even, in the given time domain, several locations exhibit presence of both propagating and standing oscillations at different frequencies.

Sun: oscillations↗

Wisconsin In Situ Penning (WISP) gauge: A versatile neutral pressure gauge to measure partial pressures in strong magnetic fields

A new type of in-vessel Penning gauge, the Wisconsin In Situ Penning (WISP) gauge, has been developed and successfully operated in the Wendelstein 7-X (W7-X) island divertor baffle and vacuum vessel. The capacity of the quantitative measurements of the neutral reservoir for light impurities, in particular, helium, is important for tokamaks as well as stellarator divertors in order to avoid fuel dilution and radiative energy loss. Penning gauges assisted by spectroscopy are a powerful tool to obtain the total neutral pressure as well as fractional neutral pressures of specific impurities. The WISP gauge is a miniaturized Penning gauge arrangement, which exploits the ambient magnetic field of magnetic confinement fusion experiments to establish the Penning discharge. Then, in situ spectroscopy is conducted to separate the fractional neutral pressures of hydrogen, helium, and possibly also other impurities. The WISP probe head was qualified using the magnetic field of the Magnetized Dusty Plasma Experiment at Auburn University between 0.25 T and 3.5 T [E. Thomas et al ., J. Plasma Phys. 81, 345810206 (2015)]. The in-depth quantitative evaluation for hydrogen and helium will be shown as well as an exploration of nitrogen, argon, and neon. A power law scaling between current I and pressure p, I = f (Gas,V) p n⁽Gas, B⁾ , was shown. The factor f is gas and anode potential dependent, while n is gas and magnetic field strength dependent. Pressure measurements from 0.1 mbar and down to 1 × 10 -5 mbar were achieved, demonstrating a reliable operating range for relevant pressure levels in the divertor and main vessel regions in current and future fusion devices, with a time resolution of up to 1 kHz. The lowest achievable pressure measurement increases with an increase in B and can be shifted with the anode potential V . At W7-X, the WISP probe head was mounted on an immersion tube setup that passes through the cryostat and places the probe head close to the plasma. Two probe heads were positioned in different divertor pump gaps, top and bottom, and one close to the plasma on the midplane in one module. The gauges were in situ calibrated together with the ASDEX pressure gauges [G. Haas and H.-S. Bosch, Vacuum 51, 39 (1998)]. Data were taken during the entire operation phase 1.2b, and measurements were coherent with other neutral gas pressure gauges. For the spectroscopic partial pressure measurements, channels of a spectroscopic detection system based on photo-multipliers, a so-called filterscope [R. J. Colchin et al ., Rev. Sci. Instrum. 74, 2068 (2003)], provided by the Oak Ridge National Lab were used.

47 OTHER INSTRUMENTATION↗

A Massive, Position-Resolving, High-Energy-Resolution Detector for Non-Accelerator Cosmic and Intensity Frontier Particle Physics

We proposed to take the first steps in the development of a detector that promises energy resolution of tens of eV FWHM combined with robust nuclear-recoil discrimination and high fidelity, mm-precision position reconstruction for applications in non-accelerator particle physics at the Cosmic and Intensity Frontiers. The detector would obtain these excellent resolutions by sensing athermal phonons produced by particle interactions in crystalline, dielectric targets using a sensitive, highly multiplexable superconducting phonon sensor, the kinetic inductance detector (KID). This detector would be applicable to: the search for low-mass particle dark matter candidates with masses below 5~GeV via direct detection of scattering of dark matter particles with terrestrial nuclei; detection of coherent elastic neutrino-nucleus scattering to test for new physics such as a non-standard value of the weak nuclear charge, non-standard neutrino interactions (perhaps driven by a neutrino magnetic moment), or the existence of sterile neutrinos; and, searches for neutrinoless double-beta decay. During the funding period, we demonstrated scaling up of the detector concept from a 22-mm by 22-mm by 1-mm, 1-g prototype with 0.9~keV FWHM energy resolution to a 75-mm diameter by 1-mm, 9-g prototype while improving the inferred energy resolution to 0.7~keV~FWHM. In the process, we solved many problems associated with scaling device fabrication to large wafers and vastly reduced the fraction of the surface occupied by inactive but energy-absorbing metal. We also demonstrated a new technique that substantially simplifies the process of characterizing a new detector. These results provide a good foundation for future work scaling up the design to 4-mm thickness substrates and improving the resolution to reach 0.035~keV~FWHM, yielding a detector with compelling potential for the above applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectroscopic Study of Solar Transition Region Oscillations in the Quiet-Sun Observed By IRIS Using the Si IV Spectral Line

In this paper, we use the Si IV 1393.755 Å spectral line observed by the Interface Region Imaging Spectrograph (IRIS) in the quiet-Sun (QS) to determine the physical nature of the solar transition region (TR) oscillations. We analyse the properties of these oscillations using wavelet tools (e.g. power, cross-power, coherence, and phase difference) along with the stringent noise model (i.e. power law + constant). We estimate the period of the intensity and Doppler velocity oscillations at each chosen location in the QS and quantify the distribution of the statistically significant power and associated periods in one bright region and two dark regions. In the bright TR region, the mean periods in intensity and velocity are 7 min and 8 min, respectively. In the dark regions, the mean periods in intensity and velocity are 7 min and 5.4 min, respectively. We also estimate the phase difference between the intensity and Doppler velocity oscillations at each location. The statistical distribution of the phase difference is estimated, which peaks at −119° ± 13°, 33° ± 10°, 102° ± 10° in the bright region and at −153° ± 13°, 6° ± 20°, 151° ± 10° in the dark regions. The statistical distribution reveals that the oscillations are caused by propagating slow magneto-acoustic waves encountered with the TR. Some of these locations may also be associated with standing slow waves. Moreover, in the given time domain, several locations exhibit the presence of both propagating and standing oscillations at different frequencies.

MHD – Sun: oscillations↗

Ka-band linearizer for the Ultra-Compact X-ray free-electron laser at UCLA

There is a strong demand for accelerating structures able to achieve higher gradients and more compact dimensions for the next generation of linear accelerators for research, industrial and medical applications. Notably innovative technologies will permit compact and affordable advanced accelerators as the linear collider and X-ray free-electron lasers (XFELs) with accelerating gradients over twice the value achieved with current technologies. In particular XFELs are able to produce coherent X-ray pulses with peak brightness 10 orders of magnitude greater than preceding approaches, which has revolutionized numerous research fields through imaging of the nanoscopic world at the time and length scale of atom-based systems, that is of femtosecond and Angstrom. There is a strong interest for combining these two fields, to form a proper tool with the goal of producing a very compact XFEL in order to investigate multi-disciplinary topics in chemistry, biology, materials science, medicine and physics. In the framework of the Ultra-Compact XFEL project under study at the University of California, Los Angeles, a high gradient radio-frequency accelerating structure for the longitudinal phase-space linearization with an integrated voltage of at least 15 MV working on 6th harmonic of the main Linac frequency is required. We here present the electromagnetic design of a cryogenic normal-conducting 8 cm long Ka-band standing-wave linearizer working on π mode with a target accelerating gradient beyond 100 MV/m. The studies have been performed analytically and numerically to investigate the beam dynamics and electromagnetic issues.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A hydrodynamic approach to cosmology: The mixed dark matter cosmological scenario

We compute the evolution of spatially flat, mixed cold and hot dark matter models containing both baryonic matter and two kinds of dark matter. Hydrodynamics is treated with a highly developed Eulerian hydrodynamic code (see Cen 1992). A standard particle-mesh (PM) code is also used in parallel to calculate the motion of the dark matter components. We adopt the following parameters: h equivalent to (sub 0)/100 km/s Mpc(exp -1) = 0.5, OMEGA(sub C) = 0.3, and OMEGA(sub B) = 0.06, with amplitude of the perturbation spectrum fixed by the Cosmic Background Explorer Satellite (COBE) Dark Matter Radiation (DMR) measurements (Smoot et al. 1992) being sigma (sub 8) = 0.67. Four different boxes are simulated with box sizes of L = (64, 16, 4, 1) h(exp -1) Mpc, respectively, the two small boxes providing good resolution but little valid information due to absence of large-scale power. We use 128(exp 3) approximate 10(exp 6.3) baryonic cells, 128(exp .3) cold dark matter particles, and 2 x 128(exp 3) hot dark matter particles. In addition to the dark matter we follow separately six baryonic species (H, H(+), He, He(+), He(++), e(-)) with allowance for both (nonequilibrium) collisional and radiative ionization in every cell. The background radiation field is also followed in detail with allowance made for both continuum and line processes, to allow nonequilibrium heating and cooling processes to be followed in detail. The mean final Zeldovich-Sunyaev y parameter is estimated to be y Bar = (5.4 + or - 2.7) x 10(exp -7) below currently attainable observations, with a rms fluctuation of approximately delta bar y = (0.6 + or - 3.0) x 10(exp -7) on arcminute scales. The rate of galaxy formation peaks at an even later epoch (z approximate 0.3) than in the standard (OMEGA = 1, sigma sub 8 = 0.67) cold dark matter (CDM) model (z approximate 0.5) and, at a redshift of z = 4, is nearly a factor of 100 lower than for the CDM model with the same value of sigma sub 8. With regard to mass function, the smallest objects are stabilized against collapse by thermal energy: the mass-weighted mass spectrum has a broad peak in the vicinity of M(sub B) = 10(exp 9.5) solar mass with a reasonable fit to the Schechter luminosity function if the ratio of baryon mass to blue light is approximately 4. In addition, one very large PM simulation was made in a box with size (320 h(exp - 1) Mpc) containing 3 x 200(exp 3) = 10(exp 7.4) particles. Utilizing this simulation we find that the model yields a cluster mass function which is about a factor of 4 higher than observed, but a cluster-cluster correlation length marginally lower than observed, but that both are closer to observations than in the (COBE) normalized CDM model. The one-dimensional pairwise velocity dispersion is 605 + or - 8 km/s at 1/h separation, lower than that of the DCM model normalized to COBE, but still significant higher than observations (Davis & Peebles 1983). A plausible velocity bias b(sub v) = 0.8 + or - 0.1 on this scale will reduce but not remove the discrepancy. The velocity auto-correlat ion function has a coherence length of 40/h Mpc, which is somewhat lower than the observed counterpart. In all these respects the model would be improved by decreasing the cold fraction of the dark OMEGA(sub CDM)/ (OMEGA(sub CDM) + OMEGA(sub HDB). But formation of galaxies and clusters of galaxies is much later in this model than in COBE-normalized CDM, perhaps too late. To improve on these constraints a larger ratio of OMEGA(sub CDM)/ (OMEGA(sub CDM) + OMEGA(sub HDM)) is required than the value of 0.67 adopted here. It does not seem possible to find a value for this ratio which would satisfy all tests. Overall, the model is similar both on large and intermediate scales to the standard CDM model normalized to the same value of sigma(sub B), but the problem with regard to late formation of galaxies is more severe in this model than in that CDM model. Adding hot dark matter, significantly improves the ability of the COBE-normalized CDM scenario to fit existing observations, but the model is in fact not as good as the CDM model with the same sigma(sub 8) and is still probably unsatisfactory with regard to several critical tests.

Cen, Renyue↗

The time-resolved atomic, molecular and optical science instrument at the Linac Coherent Light Source

The newly constructed time-resolved atomic, molecular and optical science instrument (TMO) is configured to take full advantage of both linear accelerators at SLAC National Accelerator Laboratory, the copper accelerator operating at a repetition rate of 120 Hz providing high per-pulse energy as well as the superconducting accelerator operating at a repetition rate of about 1 MHz providing high average intensity. Both accelerators power a soft X-ray free-electron laser with the new variable-gap undulator section. With this flexible light source, TMO supports many experimental techniques not previously available at LCLS and will have two X-ray beam focus spots in line. Thereby, TMO supports atomic, molecular and optical, strong-field and nonlinear science and will also host a designated new dynamic reaction microscope with a sub-micrometer X-ray focus spot. The flexible instrument design is optimized for studying ultrafast electronic and molecular phenomena and can take full advantage of the sub-femtosecond soft X-ray pulse generation program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Towards a wavefront-preservation X-ray crystal monochromator for high-repetition-rate FELs

The wavefront preservation of coherent X-ray free-electron laser beams is pushing the requirement on the quality and performance of X-ray optics to an unprecedented level. The Strehl ratio can be used to quantify this requirement. In this paper, the criteria for thermal deformation of the X-ray optics are formulated, especially for crystal monochromators. To preserve the X-ray wavefront, the standard deviation of the height error should be sub-nm for mirrors and less than 25 pm for crystal monochromators. Cryocooled silicon crystals combined with two techniques can be used to achieve this level of performance for monochromator crystals: (1) using a focusing element to compensate the second-order component of the thermal deformation; (2) introducing a cooling pad between the cooling block and silicon crystal and optimizing the effective cooling temperature. Each of these techniques allows the thermal deformation in standard deviation of the height error to be reduced by an order of magnitude. As an example, for the LCLS-II-HE Dynamic X-ray Scattering instrument, the criteria on thermal deformation of a high-heat-load monochromator crystal can be achieved for a 100 W SASE FEL beam. Wavefront propagation simulations confirm that the reflected beam intensity profile is satisfactory on both the peak power density and focused beam size.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electron beam characterization via quantum coherent optical magnetometry

We present a quantum optics-based detection method for determining the position and current of an electron beam. As electrons pass through a dilute vapor of rubidium atoms, their magnetic field perturbs the atomic spin's quantum state and causes polarization rotation of a laser resonant with an optical transition of the atoms. By measuring the polarization rotation angle across the laser beam, we recreate a 2D projection of the magnetic field and use it to determine the e-beam position, size, and total current. We tested this method for an e-beam with currents ranging from 30 to 110 μA. Our approach is insensitive to electron kinetic energy, and we confirmed that experimentally between 10 and 20 keV. In conclusion, this technique offers a unique platform for noninvasive characterization of charged particle beams used in accelerators for particle and nuclear physics research.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Weak-charge form-factor determination at the electron-ion collider

Determining the weak charge form factor, 𝐹 𝑊 ⁡(𝑄 2 ), of nuclei over a continuous range of momentum transfers, 0 ≲ 𝑄 2 ≲ 0.1 GeV 2 , is essential for mapping out the distribution of neutrons in nuclei. The neutron density distribution has significant implications for a broad range of areas, including studies of nuclear structure, neutron stars, and physics beyond the Standard Model. Currently, our knowledge of 𝐹 𝑊 ⁡(𝑄 2 ) comes primarily from fixed target experiments that measure the parity-violating asymmetry in coherent elastic electron-ion scattering. Fixed target experiments, such as CREX and PREX-1,2, have provided high-precision weak charge form factor extractions for the 48 Ca and 208 Pb nuclei, respectively. However, a major limitation of fixed target experiments is that they each provide data only at a single value of 𝑄 2 . With the proposed electron-ion collider (EIC) on the horizon, we explore its potential to impact the determination of the weak charge form factor. While it cannot compete with the precision of fixed target experiments, it can provide data over a wide and continuous range of 𝑄 2 values, and for a wide variety of nuclei. We show that with data corresponding to an integrated luminosity of ℒ ∼ 500/𝐴 fb −1 , where 𝐴 is the nucleus atomic weight, the EIC can significantly impact constraints by lifting degeneracies in theoretical models of the neutron density distribution. Ensuring EIC detector coverage at low 𝑄 2 and large negative pseudorapidities will be essential for such 𝐹 𝑊 ⁡(𝑄 2 ) measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evidence for Oscillating Two-Stream Instability and Spatial Collapse of Langmuir Waves in a Solar Type II Radio Burst

We present the high time resolution in situ observations of Langmuir waves, likely excited by an electron beam accelerated by a coronal-mass ejection-driven super-critical quasi-perpendicular interplanetary shock into its upstream solar wind, which happens to be the source region of a solar type II radio burst. We show that (1) these waves occur as coherent localized magnetic-field-aligned, one-dimensional wave packets with durations of a few milliseconds and with peak intensities well in excess of the threshold for strong turbulence processes, (2) they provide what is believed to be the first evidence for: (a) the oscillating two-stream instability (OTSI) L(sub 1) + L(sub 2) S/⟶ U + D, where L(sub 1) and L(sub 2), U and D, and S are the pump Langmuir waves, up- and down-shifted side bands, and ion sound waves, respectively, (b) a three-wave interaction U + D ⟶ T(sub 2f(sub pe)), where T(sub 2f(sub pe)) is the second harmonic electromagnetic wave, (3) they satisfy the threshold condition for formation of collapsing solitons, and (4) they are accompanied by their ponderomotive force induced density cavities with δn(sub p)/n(sub e) > δn(sub b)/n(sub e), where δn(sub p)/n(sub e) is the level of ponderomotive force induced density fluctuations and δn(sub b)/n(sub e) is that of the ambient fluctuations. These findings strongly suggest that the observed wave packets provide evidence for the collapsing solitons formed as a result of OTSI. The implication is that the strong turbulence processes probably play very important roles in excitation of type II radio emissions as well as in stabilization of shock-accelerated electron beams.

Sun radio radiation↗

Data-driven modeling and control of an X-ray bimorph adaptive mirror

Adaptive X-ray mirrors are being adopted on high-coherent-flux synchrotron and X-ray free-electron laser beamlines where dynamic phase control and aberration compensation are necessary to preserve wavefront quality from source to sample, yet challenging to achieve. Additional difficulties arise from the inability to continuously probe the wavefront in this context, which demands methods of control that require little to no feedback. In this work, a data-driven approach to the control of adaptive X-ray optics with piezo-bimorph actuators is demonstrated. This approach approximates the non-linear system dynamics with a discrete-time model using random mirror shapes and interferometric measurements as training data. For mirrors of this type, prior states and voltage inputs affect the shape-change trajectory, and therefore must be included in the model. Without the need for assumed physical models of the mirror's behavior, the generality of the neural network structure accommodates drift, creep and hysteresis, and enables a control algorithm that achieves shape control and stability below 2 nm RMS. Using a prototype mirror and ex situ metrology, it is shown that the accuracy of our trained model enables open-loop shape control across a diverse set of states and that the control algorithm achieves shape error magnitudes that fall within diffraction-limited performance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron capture-induced nuclear recoils as background for CE$v$⁢NS measurements at reactors

Nuclear reactors represent a promising neutrino source for CE⁢v⁢NS (coherent-elastic neutrino-nucleus scattering) searches. However, reactor sites also come with high ambient neutron flux. Neutron capture-induced nuclear recoils can create a spectrum that strongly overlaps the CEv⁢NS signal for recoils ≲100 eV for nuclear reactor measurements in silicon or germanium detectors. This background can be particularly critical for low-power research reactors providing a moderate neutrino flux. Here, in this work we quantify the impact of this background and show that, for a measurement 10 m from a 1 MW reactor, the effective thermal neutron flux should be kept below ~7 × 10 –4 ⁢n/cm 2 s so that the CE⁢v⁢NS events can be measured at least at a 5⁢σ level with germanium detectors in 100 kg yr exposure time. This flux corresponds to 60% of the sea-level flux but needs to be achieved in a nominally high-flux (reactor) environment. Improved detector resolution can help the measurements, but the thermal flux is the key parameter for the sensitivity of the experiment. For silicon detectors, the constraint is even stronger and thermal neutron fluxes must be near an order of magnitude lower. This constraint highlights the need of an effective thermal neutron mitigation strategy for future low threshold CEv⁢NS searches. In particular, the neutron capture-induced background can be efficiently reduced by active veto systems tagging the deexcitation gamma following the capture.

79 ASTRONOMY AND ASTROPHYSICS↗

Nuclear Data to Reduce Uncertainties in Reactor Antineutrino Measurements

The large quantities of antineutrinos produced through the decay of fission fragments in nuclear reactors provide an opportunity to study the properties of these particles and investigate their use in reactor monitoring. The reactor antineutrino spectra are measured using specialized, large area detectors that detect antineutrinos through inverse beta decay, electron elastic scattering, or coherent elastic neutrino nucleus scattering; although, inverse beta decay is the only demonstrated method so far. Reactor monitoring takes advantage of the differences in the antineutrino yield and spectra resulting from uranium and plutonium fission providing an opportunity to estimate the fissile material composition in the reactor. Recent experiments reveal a deviation between the measured and calculated antineutrino flux and spectra (the reactor anomaly) indicating either the existence of yet undiscovered neutrino physics, uncertainties in the reactor source term calculation, incorrect nuclear data, or a combination of all three. To address the nuclear data that impact the antineutrino spectrum calculations and measurements, an international group of over 180 experts in antineutrino physics, reactor analysis, detector development, and nuclear data came together during the Workshop on Nuclear Data for Reactor Antineutrino Measurements (WoNDRAM) to discuss nuclear data needs and achieve concordance on a set of recommended priorities for nuclear data improvements. Three topical sessions focused on the reactor source term, the antineutrino spectrum, and the detector response, provided a forum to gain consensus amongst the participants on the most important data improvements to address two goals: 1) understand the reactor anomaly and 2) improve the ability to monitor reactors using antineutrinos. This report summarizes the outcomes of the workshop discussions and the recommendations for nuclear data efforts that reduce reactor antineutrino measurement uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗