Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cavity optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Multiplexed gas spectroscopy using tunable VCSELs

Detection and identification of gas species using tunable laser diode laser absorption spectroscopy has been performed using vertical cavity surface emitting lasers (VCSEL). Two detection methods are compared: direct absorbance and wavelength modulation spectroscopy (WMS). In the first, the output of a DC-based laser is directly monitored to detect for any quench at the targeted specie wavelength. In the latter, the emission wavelength of the laser is modulated by applying a sinusoidal component on the drive current of frequency {omega}, and measuring the harmonics component (2{omega}) of the photo-detected current. This method shows a better sensitivity measured as signal to noise ratio, and is less susceptible to interference effects such as scattering or fouling. Gas detection was initially performed at room temperature and atmospheric conditions using VCSELs of emission wavelength 763 nm for oxygen and 1392 nm for water, scanning over a range of approximately 10 nm, sufficient to cover 5-10 gas specific absorption lines that enable identification and quantization of gas composition. The amplitude and frequency modulation parameters were optimized for each detected gas species, by performing two dimensional sweeps for both tuning current and either amplitude or frequency, respectively. We found that the highest detected signal is observed for a wavelength modulation amplitude equal to the width of the gas absorbance lines, in good agreement with theoretical calculations, and for modulation frequencies below the time response of the lasers (<50KHz). In conclusion, we will discuss limit of detection studies and further implementation and packaging of VCSELs in diode arrays for continuous and simultaneous monitoring of multiple species in gaseous mixtures.

42 ENGINEERING↗

Optimal Patient Positioning (Prone Versus Supine) for VMAT in Gynecologic Cancer: A Dosimetric Study on the Effect of Different Margins

Purpose/Objective: It is unknown whether the historically found dosimetric advantages of treating gynecologic cancer with the patient in a prone position with use of a small-bowel displacement device (belly-board) remain when volumetric arc therapy (VMAT) is used and whether these advantages depend on the necessary margin between clinical target volume (CTV) and planning target volume (PTV). The aim of this study is to determine the best patient position (prone or supine) in terms of sparing organs at risk (OAR) for various CTV-to-PTV margins and VMAT dose delivery. Methods and Materials: In an institutional review board—approved study, 26 patients with gynecologic cancer scheduled for primary (9) or postoperative (17) radiation therapy were scanned in a prone position on a belly-board and in a supine position on the same day. The primary tumor CTV, nodal CTV, bladder, bowel, and rectum were delineated on both scans. The PTVs were created each with a different margin for the primary tumor and nodal CTV. The VMAT plans were generated with our in-house system for automated treatment planning. For all margin combinations, the supine and prone plans were compared with consideration of all OAR dose-volume parameters but with highest priority given to bowel cavity V{sub 45Gy} (cm{sup 3}). Results: For both groups, the prone position reduced the bowel cavity V{sub 45Gy}, in particular for nodal margins ≥10 mm (ΔV{sub 45Gy} = 23.9 ± 10.6 cm{sup 3}). However, for smaller margins, the advantage was much less pronounced (ΔV{sub 45Gy} = 6.5 ± 3.0 cm{sup 3}) and did not reach statistical significance. The rectum mean dose (D{sub mean}) was significantly lower (ΔD{sub mean} = 2.5 ± 0.3 Gy) in the prone position for both patient groups and for all margins, and the bladder D{sub mean} was significantly lower in the supine position (ΔD{sub mean} = 2.6 ± 0.4 Gy) only for the postoperative group. The advantage of the prone position was not present if it needed a larger margin than the supine position. Conclusion: For patients with gynecologic cancer, the historically found dosimetric advantages for the prone position remain for modern dose delivery techniques if large margins are needed. However, the advantage is lost for small margins and if the prone position needs a larger margin than the supine position.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Universal Solvation Model Based on Solute Electron Density and on a Continuum Model of the Solvent Defined by the Bulk Dielectric Constant and Atomic Surface Tensions

We present a new continuum solvation model based on the quantum mechanical charge density of a solute molecule interacting with a continuum description of the solvent. The model is called SMD, where the “D” stands for “density” to denote that the full solute electron density is used without defining partial atomic charges. “Continuum” denotes that the solvent is not represented explicitly but rather as a dielectric medium with surface tension at the solute-solvent boundary. SMD is a universal solvation model, where “universal” denotes its applicability to any charged or uncharged solute in any solvent or liquid medium for which a few key descriptors are known (in particular, dielectric constant, refractive index, bulk surface tension, and acidity and basicity parameters). The model separates the observable solvation free energy into two main components. The first component is the bulk electrostatic contribution arising from a self-consistent reaction field treatment that involves the solution of the nonhomogeneous Poisson equation for electrostatics in terms of the integral-equation-formalism polarizable continuum model (IEF-PCM). The cavities for the bulk electrostatic calculation are defined by superpositions of nuclear-centered spheres. The second component is called the cavity-dispersion-solvent-structure term and is the contribution arising from short-range interactions between the solute and solvent molecules in the first solvation shell. This contribution is a sum of terms that are proportional (with geometry-dependent proportionality constants called atomic surface tensions) to the solvent-accessible surface areas of the individual atoms of the solute. The SMD model has been parametrized with a training set of 2821 solvation data including 112 aqueous ionic solvation free energies, 220 solvation free energies for 166 ions in acetonitrile, methanol, and dimethyl sulfoxide, 2346 solvation free energies for 318 neutral solutes in 91 solvents (90 nonaqueous organic solvents and water), and 143 transfer free energies for 93 neutral solutes between water and 15 organic solvents. The elements present in the solutes are H, C, N, O, F, Si, P, S, Cl, and Br. The SMD model employs a single set of parameters (intrinsic atomic Coulomb radii and atomic surface tension coefficients) optimized over six electronic structure methods: M05-2X/MIDI!6D, M05-2X/6-31G*, M05-2X/6-31+G**, M05-2X/cc-pVTZ, B3LYP/6-31G*, and HF/6-31G*. Although the SMD model has been parametrized using the IEF-PCM protocol for bulk electrostatics, it may also be employed with other algorithms for solving the nonhomogeneous Poisson equation for continuum solvation calculations in which the solute is represented by its electron density in real space. This includes, for example, the conductor-like screening algorithm. With the 6-31G* basis set, the SMD model achieves mean unsigned errors of 0.6-1.0 kcal/mol in the solvation free energies of tested neutrals and mean unsigned errors of 4 kcal/mol on average for ions with either Gaussian03 or GAMESS.

36 MATERIALS SCIENCE↗

AN INNOVATIVE Nb3Sn FILM APPROACH AND ITS POTENTIAL FOR SRF APPLICATIONS

A novel electro-chemical technique to produce Nb3Sn films on Nb substrates was developed and optimized at Fermilab. The Nb3Sn phase is obtained in a two-electrode cell, by electrodeposition from aqueous solutions of Sn lay-ers and Cu intermediate layers onto Nb substrates. Subse-quent thermal treatments in inert atmosphere are realized at a maximum temperature of 700°C to obtain the Nb3Sn superconducting phase. Several superconducting Nb3Sn films were obtained on Nb substrates by studying and op-timizing most parameters of the electro-plating process. Samples were characterized at Fermilab, NIMS, KEK and JLab, including SEM/EPMA analyses, DC and inductive tests of critical temperature Tc0, and lower critical field Hc1(4.2 K) by SQUID. In parallel to sample development and fabrication at FNAL, at JLab and KEK effort was put into etching and electro-polishing techniques adequate to remove the Cu and bronze phases from the samples’ outer surface. This is necessary prior to measurements at JLab of the surface impedance of flat samples in a setup that make use of an RF host cavity.

43 PARTICLE ACCELERATORS↗

Strain-concentration for fast, compact photonic modulation and non-volatile memory

A critical figure of merit (FoM) for electro-optic (EO) modulators is the transmission change per voltage, d T / d V . Conventional approaches in wave-guided modulators maximize d T / d V via a high EO coefficient or longer light-material interaction lengths but are ultimately limited by material losses and nonlinearities. Optical and RF resonances improve d T / d V at the cost of spectral non-uniformity, especially for high- Q optical cavity resonances. Here, we introduce an EO modulator based on piezo-strain-concentration of a photonic crystal cavity to address both trade-offs: (i) it eliminates the trade-off between d T / d V and waveguide loss—i.e., enhancement of the resonance tuning efficiency d v c / d V for the fixed EO coefficient, waveguide length, and cavity Q —and (ii) at high DC strains it exhibits a non-volatile (NV) cavity tuning Δ v c ,NV for passive memory and programming of multiple devices into resonance despite fabrication variations. The device is fabricated on a scalable silicon nitride-on-aluminum nitride platform. We measure d v c / d V =177±1MHz/V, corresponding to Δ v c =40±0.32GHz for a voltage spanning ±120V with an energy consumption of δ U /Δ v c =0.17nW/GHz. The modulation bandwidth is flat up to ω BW,3dB /2 π =3.2±0.07MHz for broadband DC-AC and 142±17MHz for resonant operation near a 2.8 GHz mechanical resonance. Optical extinction up to 25 dB is obtained via Fano-type interference. Strain-induced beam-buckling modes are programmable under a “read-write” protocol with a continuous, repeatable tuning range of 5±0.25GHz, allowing for storage and retrieval, which we quantify with mutual information of 2.4 bits and a maximum non-volatile excursion of 8 GHz. Using a full piezo-optical finite-element-model (FEM) we identify key design principles for optimizing strain-based modulators and chart a path towards achieving performance comparable to lithium niobate-based modulators and the study of high strain physics on-chip.

Wen, Y. Henry (ORCID:0009000685423628)↗

A Forward Feedback Control Scheme for a Solar Thermochemical Moving Bed Counter-Current Flow Reactor

Abstract Pelletized thermochemical energy storage media has a potential for long-duration energy storage. Production of solid-state energy storage media can be done within a cavity chemical reactor that captures concentrated solar radiation from a solar thermal field. The temperature stability of a solar reactor is directly influenced by the solar flux intercepted. This paper presents a low-order physical model to simulate the dynamic response of temperature inside a tubular plug-flow reactor prototype. Solid granular particles are fed to the reactor from the top whereas a counter-current flowing gas enters the reactor from the bottom. An in-house code was developed to model transient heat transfer of the reactor wall, gas, and moving particles. The model was preliminarily validated with packed beds for different temperature ranges and two gas flowrates. Dynamic response of the reactor temperature is simulated for different input power and gas/particle flowrates. The results show that the system response can be controlled efficiently by utilizing input power (solar flux) as a control parameter. A conventional proportional integral (PI) controller is designed to control the temperature inside the reactor and to maintain it during the solar flux intermittency. The controller parameters are tuned using the Ziegler–Nichols method to ensure optimal system response. The results show that the feedback control model is successful in tracking different reference reactor temperatures within a reasonable settling time of 30 min and eliminated overshoot. This study can be extended to include a hybrid reactor with a multi-input, multi-output variable system.

Energy & Fuels↗

SU-E-T-615: Investigation of the Dosimetric Impact of Tandem Loading in the Treatment of Cervical Cancer for HDR Brachytherapy Procedures

Purpose: To quantify the dosimetric impact of the tandem loading in the treatment of cervical cancer for HDR brachytherapy procedures. Methods: Ten patients were evaluated, each of whom received 5 fractions of treatment. Tandem and ovoid sets were inserted into the uterine cavity based on institutional protocols and procedures. Following insertion and stabilization, CT image sets of 1.5mm slice thickness were acquired and sent to the Oncentra V4.3 Treatment Planning System. Critical structures such as the CTV, bladder, rectum, sigmoid, and bowel were contoured and a fractional dose of 5.5Gy was prescribed to Point A for each patient. Six different treatment plans were created for each fraction using varying tandem weightings; from 0.5 to 1.4 times that of the ovoids. Surface dose evaluation of various ovoid diameters, 2.0-3.5cm, at the vaginal fornices was also investigated. Results: Critical structures were evaluated based on varying dose and volume constraints, in particular the 2.0 cc volume recommendation cited by the gynecological GEC-ESTRO working group. Based on dose volume histogram evaluation, a reduction of dose to the critical structures was most often discovered when the tandem weighting was increased. CTV coverage showed little change as the tandem weighting was varied. Ovoid surface dose decreased by 50-65% as the tandem weighting increased. Conclusion: The advantage of 3D planning with HDR brachytherapy is the dose optimization for each individual treatment plan. This investigation shows that by utilizing large tandem weightings, 1.4 times greater than the ovoid, one can still achieve adequate coverage of the CTV and relatively low doses to the critical structures. In some cases, one would still have to optimize further per individual case. In addition, the ovoid surface dose was greatly decreased when large tandem weighting was utilized; especially for small ovoid diameters.

60 APPLIED LIFE SCIENCES↗

Studies on x-ray and UV emissions in electron cyclotron resonance x-ray source

A novel electron cyclotron resonance x-ray source is constructed based on the ECR technique. In this paper, the possibility of using the ECR x-ray source for producing UV rays by optimizing the plasma parameters is explored. X-ray and UV emissions from the ECR x-ray source are carried out for argon, nitrogen, and CO{sub 2} plasma. The x-ray spectral and dose measurements are carried with NaI(Tl) based spectrometer and dosimeter, respectively. For UV measurement, a quartz window arrangement is made at the exit port and the UV intensity is measured at 5 cm from the quartz plate using UV meter. The x-ray and UV emissions are carried out for different microwave power levels and gas pressures. The x-ray emission is observed in the pressure range {<=}10{sup -5} Torr, whereas the UV emission is found to be negligible for the gas pressures <10{sup -5} Torr and it starts increasing in the pressure range between 10{sup -5} and 10{sup -3} Torr. At high-pressure range, collision frequency of electron-atom is large which leads to the higher UV flux. At low pressure, the electron-atom collision frequency is low and hence the electrons reach high energy and by hitting the cavity wall produces higher x-ray flux. By choosing proper experimental conditions and plasma gas species, the same source can be used as either an x-ray source or an UV source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermomechanical analysis and modeling of a high-temperature light trapping planar cavity solar receiver

The development of durable particle-based high-temperature solar receivers is critical for advancing concentrating solar-thermal (CST) technologies to enable high-efficiency power generation and industrial process heat. Here, this study presents a computational framework to evaluate the thermomechanical performance of a proposed enclosed light-trapping planar cavity receiver designed for particle-based thermal energy systems. The receiver incorporates absorptive cavities and fluidized particle-bed channels to enhance heat capture and reduce thermal losses. Finite element analysis (FEA) is employed to assess stress, strain, and creep-fatigue behavior under concentrated solar flux using realistic thermal boundary conditions derived from coupled system models and experimental assembly parameters. The analysis investigates the influence of particle-to-wall heat transfer coefficients (HTC) ranging from 800 to 1800 W/m 2 .K on the thermomechanical response of six candidate high-temperature alloys: Alloy 740H, Alloy 282, Alloy 617, 316H, Alloy 230, and 800H. Results show that increasing HTC reduces thermal gradients, leading to lower stresses and strains and extended minimum predicted creep life. While all materials satisfy fatigue life requirements under the investigated conditions, significant differences in creep resistance are observed. Alloy 740H consistently exhibits the longest minimum predicted creep life and the most favorable durability margins, followed by Alloy 282, with the remaining materials showing reduced creep resistance under identical loading. The reported creep lives are conservative lower-bound estimates intended for comparative material evaluation. This framework highlights the critical roles of material selection and geometry optimization in improving mechanical durability and reliability of solar-thermal receivers, forming a foundation for future experimental validation and design optimization.

14 SOLAR ENERGY↗

Computations of absolute solvation free energies of small molecules using explicit and implicit solvent model.

Accurate determination of absolute solvation free energy plays a critical role in numerous areas of biomolecular modeling and drug discovery. A quantitative representation of ligand and receptor desolvation, in particular, is an essential component of current docking and scoring methods. Furthermore, the partitioning of a drug between aqueous and nonpolar solvents is one of the important factors considered in pharmacokinetics. In this study, the absolute hydration free energy for a set of 239 neutral ligands spanning diverse chemical functional groups commonly found in drugs and drug-like candidates is calculated using the molecular dynamics free energy perturbation method (FEP/MD) with explicit water molecules, and compared to experimental data as well as its counterparts obtained using implicit solvent models. The hydration free energies are calculated from explicit solvent simulations using a staged FEP procedure permitting a separation of the total free energy into polar and nonpolar contributions. The nonpolar component is further decomposed into attractive (dispersive) and repulsive (cavity) components using the Weeks-Chandler-Anderson (WCA) separation scheme. To increase the computational efficiency, all of the FEP/MD simulations are generated using a mixed explicit/implicit solvent scheme with a relatively small number of explicit TIP3P water molecules, in which the influence of the remaining bulk is incorporated via the spherical solvent boundary potential (SSBP). The performances of two fixed-charge force fields designed for small organic molecules, the General Amber force field (GAFF), and the all-atom CHARMm-MSI, are compared. Because of the crucial role of electrostatics in solvation free energy, the results from various commonly used charge generation models based on the semiempirical (AM1-BCC) and QM calculations [charge fitting using ChelpG and RESP] are compared. In addition, the solvation free energies of the test set are also calculated using Poisson-Boltzmann (PB) and Generalized Born model of solvation (GB), which are two widely used continuum electrostatic implicit solvent models. The protocol for running the absolute solvation free energy calculations used throughout is automated as much as possible, with minimum user intervention, so that it can be used in large-scale analysis and force field optimization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WE-AB-BRA-11: Improved Imaging of Permanent Prostate Brachytherapy Seed Implants by Combining an Endorectal X-Ray Sensor with a CT Scanner

Purpose: To test feasibility of the use of a digital endorectal x-ray sensor for improved image resolution of permanent brachytherapy seed implants compared to conventional CT. Methods: Two phantoms simulating the male pelvic region were used to test the capabilities of a digital endorectal x-ray sensor for imaging permanent brachytherapy seed implants. Phantom 1 was constructed from acrylic plastic with cavities milled in the locations of the prostate and the rectum. The prostate cavity was filled a Styrofoam plug implanted with 10 training seeds. Phantom 2 was constructed from tissue-equivalent gelatins and contained a prostate phantom implanted with 18 strands of training seeds. For both phantoms, an intraoral digital dental x-ray sensor was placed in the rectum within 2 cm of the seed implants. Scout scans were taken of the phantoms over a limited arc angle using a CT scanner (80 kV, 120–200 mA). The dental sensor was removed from the phantoms and normal helical CT and scout (0 degree) scans using typical parameters for pelvic CT (120 kV, auto-mA) were collected. A shift-and add tomosynthesis algorithm was developed to localize seed plane location normal to detector face. Results: The endorectal sensor produced images with improved resolution compared to CT scans. Seed clusters and individual seed geometry were more discernable using the endorectal sensor. Seed 3D locations, including seeds that were not located in every projection image, were discernable using the shift and add algorithm. Conclusion: This work shows that digital endorectal x-ray sensors are a feasible method for improving imaging of permanent brachytherapy seed implants. Future work will consist of optimizing the tomosynthesis technique to produce higher resolution, lower dose images of 1) permanent brachytherapy seed implants for post-implant dosimetry and 2) fine anatomic details for imaging and managing prostatic disease compared to CT images. Funding: LSU Faculty Start-up Funding. Disclosure: XDR Radiography has loaned our research group the digital x-ray detector used in this work. CoI: None.

60 APPLIED LIFE SCIENCES↗

Multi-physics Modeling of Radiative Heat Transfer and Fluid Flow for the Reactor Cavity Cooling System

High-temperature gas-cooled reactors (HTGRs) are notable for their high thermal efficiency and potential for combined heat and power applications. These reactors are particularly appealing due to their advanced passive safety features. HTGRs utilize passive safety systems that function without requiring active components like pumps or compressors during emergencies. These reactor designs depend on a Reactor Cavity Cooling System (RCCS) to manage decay heat removal from the reactor pressure vessel (RPV) during accident conditions. The RCCS consists of vertical rectangular channels known as "risers" or riser ducts positioned around the RPV. These risers receive heat from the RPV through both convective and radiative heat transfer mechanisms. Understanding the interplay of multiple physical phenomena, such as fluid dynamics, heat transfer, and neutron interactions, is essential for the effective design and operation of nuclear reactors, particularly for systems like the RCCS. Multi-physics simulations provide a comprehensive approach to studying these interactions, offering detailed insights and enhancing accuracy. They are especially important in RCCS designs, where the interaction between radiative and convective heat transfer can significantly impact system performance. By leveraging multi-physics simulations, complex reactor behaviors can be modeled without compromising the fidelity of the underlying physical processes. This work aims to establish a robust methodology for coupling multiple physical processes in an air-cooled RCCS. By focusing on validating this multi-physics approach, the study involves designing test cases that simulate various conditions to verify the numerical models employed. The outcomes of this research will provide critical insights for accurately modeling and optimizing complex nuclear systems like the RCCS.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Approaching attometer laser vibrometry

The heterodyne two-beam interferometer has been proven to be the optimal solution for laser-Doppler vibrometry regarding accuracy and signal robustness. The theoretical resolution limit for a two-beam interferometer of laser class 3R (up to 5 mW visible measurement-light) is in the regime of a few femtometer per square-root Hertz and well suited to study vibrations in microstructures. However, some new applications of RF-MEM resonators, nanostructures, and surface-nano-defect detection require resolutions beyond that limit. The resolution depends only on the noise and the sensor sensitivity to specimen displacements. The noise is already defined in nowadays systems by the quantum nature of light for a properly designed optical sensor and more light would lead to an inacceptable influence like heating of a very tiny structure. Thus, noise can only be improved by squeezed-light techniques which require a negligible loss of measurement light which is impossible for almost all technical measurement tasks. Thus, improving the sensitivity is the only possible path which could make attometer laser vibrometry possible. Decreasing the measurement wavelength would increase the sensitivity but would also increase the photon shot noise. In this paper, we discuss an approach to increase the sensitivity by assembling an additional mirror between interferometer and specimen to form an optical cavity. A detailed theoretical analysis of this setup is presented and we derive the resolution limit, discuss the main contributions to the uncertainty budget, and show a first experiment proving the sensitivity amplification of our approach.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-169: Evaluation of Oncentra TPS for Nasopharynx Brachy Using Patient Specific Voxel Phantom and EGSnrc

Purpose: Nasopharnx carcinoma (NPC) treatment is being carried out using Ir-192 HDR seeds in Mehdieh Hospital in Hamadan, Iran. The Oncentra™ TPS is based on optimized TG-43 formalism which disregards heterogeneity in the treatment area. Due to abundant heterogeneity in head and neck, comparison of the Oncentra™ TPS dose evaluation and an accurate dose calculation method in NPC brachytherapy is the objective of this study. Methods: CT DICOMs of a patient with NPC obtained from Mehdieh Hospital used to create 3D voxel phantom with CTCREATE utility of EGSnrc code package. The voxel phantom together with Ir-192 HDR brachytherapy source were the input to DOSXYZnrc to calculate the 3D dose distribution. The sources were incorporate with type 6 source in DOSXYZnrc and their dwell times were taken into account in final dose calculations. Results: The direct comparison between isodoses as well as DVHs for the GTV, PTV and CTV obtained by Oncentra™ and EGSnrc Monte Carlo code are made. EGSnrc results are obtained using 5×10{sup 9} histories to reduce the statistical error below 1% in GTV and 5% in 5% dose areas. The standard ICRP700 cross section library is employed in DOSXYZnrc dose calculation. Conclusion: A direct relationship between increased dose differences and increased material density (hence heterogeneity) is observed when isodoses contours of the TPS and DOSXYZnrc are compared. Regarding the point dose calculations, the differences range from 1.2% in PTV to 5.6% for cavity region and 7.8% for bone regions. While Oncentra™ TPS overestimates the dose in cavities, it tends to underestimate dose depositions within bones.

60 APPLIED LIFE SCIENCES↗

High Quantum Efficiency Uni-Traveling-Carrier Photodiode for Optical to Microwave Transduction

Modern Quantum Information Systems (QIS) employ optical photons for long distance communication, operating at ambient temperature, between microwave cavities, which house microwave photons used in quantum computing and microwave detection. These optical photons, carried by fiber-optic or free-space links, offer a low-cost, uncooled alternative to bulky, expensive microwave coaxial cables, which are lossy, susceptible to EMI, and a significant thermal conductor to the outside ambient environment. To convert between these two types of photons and implement these optical interconnects, it is necessary to develop a high-performance photodetector for optical to microwave transduction. Freedom Photonics and the University of Virginia have a well-established partnership in developing high-performance photodiodes. In this Phase I effort, we collaborated in designing, fabricating, and testing an advanced, high-speed, high quantum efficiency prototype photodiode for transduction from optical to microwave frequencies. These devices have applications not only in quantum computing and axion detection, but also in other optical-cryogenic interconnect applications, in fields such as radio astronomy and quantum cryptography, as well as in quantum metrology and plasmonics. During this Phase I DOE program, we designed, fabricated, and tested prototype PIN GaAs photodiodes which targeted the performance parameters defined by the program. This process involved identifying a new target wavelength, different from that proposed initially, based on conversations with the Oak Ridge National Lab customer. We designed an epitaxial stack, optimized in theory for ≥95% quantum efficiency at 795 nm, ≥5 GHz, per the target objectives of the program. Additionally, we designed a fabrication process and associated mask plates for top-illuminated, AR-coated devices with device diameters ranging from 50 µm to 800 µm. Using these, we fabricated two 3” wafer quarters of devices, and characterized the devices’ dark current, quantum efficiency, and bandwidth for various device diameters. The prototype devices achieved a quantum efficiency of 89% at the target 795 nm detection wavelength. The bandwidth of the devices proved tricky to characterize, but a 50 µm diameter device shows a 3-dB bandwidth of at least 1.6 GHz, possibly a full 5 GHz, depending on the measurement setup. In the future, we plan to characterize the bandwidth of these devices using an impulse response measurement. All tasks for the Phase I were successfully completed, and sample prototype devices were provided to Oak Ridge National Lab Quantum Information Science researchers. The work performed in Phase I has established a strong foundation for future design and fabrication cycles in Phase II, if granted. The early tests at Oak Ridge National Labs will provide guidance for the required photodiode performance in devices to be supplied in Phase II.

42 ENGINEERING↗

Prototype Modeling for a Light-Trapping Planar-Cavity Enclosed Particle Solar Receiver

Concentrating solar thermal (CST) systems present a promising avenue for affordable and reliable energy production. Solar receivers are key components that determine the efficiency and longevity of these systems. Particle-based solar receivers have emerged as a compelling alternative to traditional technologies, offering several advantages that address limitations in current CST systems. This is especially true as next-generation CST technologies target applications including electricity generation, thermochemical processes, and industrial process heat, many of which necessitate higher operating temperatures than current commercial molten salt systems. Molten-salt thermal energy storage (TES) systems, commonly used in CSP, face challenges related to freezing and corrosion. Particle-based TES systems, in contrast, do not experience these issues, as particles are stable at high temperatures, exceeding 1000 degrees Celsius. This capability allows for a wider range of applications, including those requiring higher temperatures for industrial processes and efficient electricity generation. A novel innovation in particle-based solar receiver technology is the light-trapping planar cavity receiver (LTPCR) configuration developed by NREL. The LTPCR design consists of small cavity-like structures using opaque planar surfaces, enabling efficient capture and absorption of solar energy. A high incident flux concentration at the cavity aperture is absorbed on the receiver walls, and subsequently transferred to particles on the inside of cavities. The particles flow through the system, forming a fluidized bed inside of the receiver panels, effectively capturing the absorbed solar heat. Air is used as a fluidizing medium in this process to enhance particle heat transfer and mixing. The effectiveness of this design lies in its ability to manage solar flux conditions and ensure high solar-to-thermal receiver efficiency. A 100-kW prototype is currently being tested at the King Saud University in Saudi Arabia to assess the receiver performance. A range of modeling analyses for the optical, thermal, and mechanical effects were conducted to assess the performance of the receiver under on-sun conditions. The solar flux resulting from the KSU heliostat field was modeled using NREL SolTrace software and produced up to 600 kW/m2 at the receiver aperture. The solar flux absorbed on the receiver walls was then used within a computational fluid dynamics (CFD) model to predict wall temperature distributions along with radiation and convection loss. A two-phase CFD model was developed for the fluidized bed of silica sand inside the receiver panels to predict local wall-to-particle heat transfer coefficients, particle temperature distributions, and outlet temperature of the particles. We have also conducted analyses to understand the thermomechanical behavior of these innovative enclosed light-trapping solar receivers optimized for particle heating. We used finite element analysis (FEA) to predict the receiver's performance using temperature distributions obtained from CFD and based on the resulting stress profiles, evaluated creep-fatigue damage with a goal of achieving a 30-year service life. Analysis showed a significant impact of the particle-to-wall heat transfer coefficients (HTCs) on receiver performance, with higher HTCs resulting in reduced stress and increased lifespan. For instance, when using Inconel 740H, increasing the HTC from 800 W/m2 K to 1400 W/m2 K increased the creep life from 4,000 hours to over 100,000 hours. This highlights the importance of understanding and optimizing heat transfer in the design of high-efficiency receivers.

14 SOLAR ENERGY↗

The microstructure effects on irradiation response of ferritic – martensitic steels

Microstructural optimization to achieve greater mechanical strength has been one of the focuses in ferritic–martensitic steels development. However, these optimized microstructures’ effects on the radiation response are not well known. In this work, two ferritic–martensitic steels (9Cr-NbMo and 9Cr-Ta) underwent neutron irradiation in the High Flux Isotope Reactor, and their room-temperature post-irradiation tensile properties and microstructure evolutions were investigated and compared. These two steels exhibit similar pre-irradiation tensile behavior, and their yield strengths are higher than that of other ferritic–martensitic steels by about 200–250 MPa. Microstructural characterization on pre-irradiated materials reveals a smaller grain size in 9Cr-Ta (2.8 ± 0.3 μm in 9Cr-Ta versus 4.3 ± 0.5 μm in 9Cr-NbMo) but higher dislocation density and precipitate density in 9Cr-NbMo. As is common for ferritic–martensitic steels at low irradiation temperatures (less than about 0.45T m ), irradiation-induced hardening at 400 °C was observed for both alloys. Irradiation at 490 °C causes the two alloys to exhibit different tensile behavior: 9Cr-Ta softens by 208 MPa in yield stress, whereas 9Cr-NbMo maintains strength. Additionally, microstructural characterizations were performed, including precipitate growth, dislocation, and defect formation. Using the barrier hardening model for microstructure–property correlation, the softening in irradiated 9Cr-Ta is primarily attributed to the significant dislocation recovery, while the strength lost from the slight dislocation recovery in 9Cr-NbMo was compensated by the additional strength from the irradiation-induced cavities. The microstructure effect (primarily precipitate, dislocation and boundary) on the radiation response is discussed herein.

36 MATERIALS SCIENCE↗

Extraordinary creep resistance in a non-equiatomic high-entropy alloy from the optimum solid-solution strengthening and stress-assisted precipitation process

Improving creep resistance has commonly been achieved by the optimization of alloy design that results into strong solid-solution strengthening and/or coherent precipitates for dislocation blockage. High-entropy alloys (HEAs), despite their single-phase solid-solution nature, only exhibit creep properties that are comparable to precipitate-strengthened ferritic alloys. Moreover, many HEAs are found to be plagued with many incoherent second phases after long-term annealing, which reduces the lifetime and thus prohibits their usage at elevated temperatures. The present work demonstrates the extraordinary creep resistance of a non-equiatomic Al 0.3 CoCrFeNi HEA, in which the creep strain rate is found to be several orders of magnitude lower than the Cantor alloy and its subsets. Using a suite of characterization tools such as atom probe tomography (APT) and transmission electron microscopy (TEM), it was shown that a B2 precipitate phase that has been widely seen during annealing is suppressed during the early stage of the creep deformation. Currently, metastable and coherent L1 2 precipitates emerge and provide significant creep strengthening. This observation is rationalized by the coupling between the applied stress and the lattice mismatch. In the range of 973 ~ 1033 K, the stress exponent and activation energy were determined to be 3–6.53 and 390–548.2 kJ·mol –1 , respectively. The creep lifetime, on the other hand, is comparable to Cantor subset alloys because the precipitate free zone near the grain boundaries does not provide sufficient constraint for the grain boundary cavity growth. Furthermore, the present work provides a pathway to design novel HEAs with improved creep resistance.

36 MATERIALS SCIENCE↗