Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Operational Evolution of FTS3: A DevOps Driven Approach to Elastic Operations

The File Transfer Service (FTS3) is a distributed data movement service developed at CERN and widely used to transfer data across the Worldwide LHC Computing Grid (WLCG). At Fermilab, FTS3 supports data transfers for multiple experiments, including Intensity Frontier experiments such as DUNE, enabling reliable data movement between WebDAV endpoints in Europe and the Americas.​ At CHEP 2021, we reported on the initial containerized deployment of FTS3 on OKD, the community Kubernetes distribution of Red Hat OpenShift. In this work, we present the subsequent evolution of this deployment, focusing on new operational capabilities introduced to improve scalability, robustness, and long-term maintainability.​ We describe the adoption of more secure and reproducible container build workflows, the integration of DevOps-driven operational practices, and enhancements in monitoring and automation. A key new result is the introduction of horizontal scaling and elastic resource management, allowing FTS3 components to dynamically adapt to workload variations while maintaining service reliability. We also discuss improvements in fault tolerance and operational procedures derived from production experience.​ Finally, we summarize lessons learned from operating FTS3 as a Kubernetes-native service and outline how these developments have improved the resilience and efficiency of data movement operations at Fermilab.

Munoz Flores, Victor Leopoldo [Fermilab]↗

Completing the Circuit: Workforce Development for Advanced Building Construction and Grid-Interactive Efficient Buildings

This paper will present key findings from a future-oriented qualitative study investigating likely futures for the next 5-10 years in the architecture, engineering, construction, and operations industry. This research offers an original contribution to the buildings industry by articulating an actionable framework to more effectively build connections between built environment fields. Whereas the ideal of interdisciplinary, research driven practice underlies the approach to pedagogy at many schools of architecture, innovation in the profession, such as the integrated design process, has been limited. This project applies Legitimation Code Theory (LCT) to the analysis of data gathered from interviews and a review of industry reports.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bringing Automated Fault Detection and Diagnostics Tools for HVAC&R Into the Mainstream

Heating, ventilation, and air-conditioning (HVAC) systems consume over 5 quads of energy annually, representing 30% of energy consumption in the U.S. commercial buildings. Additionally, commercial refrigeration (R) systems add about 1 quad to commercial buildings energy consumption. Most HVAC systems operate with one or more faults that result in increased energy consumption. Fault detection and diagnostics (FDD) tools have been developed to address this national issue, and many tools are commercially available. FDD tools have the potential to save considerable energy for an existing commercial rooftop unit (RTU) and refrigeration systems. These devices can be used for both retro commissioning and, when faults are addressed, continuous commissioning. However, there appears to be multiple market barriers for this technology. Although there are efforts to develop FDD tool standards, currently there are no standards and methods to define functions, capabilities, accuracy, and reliability of FDD tools in the field. Moreover, most of the commercial FDD tools have not been verified in the field independently. This paper presents a comprehensive approach for bringing HVAC FDD tools into the mainstream. The approach involves demonstrating ten commercially available FDD tools installed at ten different sites, independent testing and evaluation of the FDD tools, communication with various stakeholders, identifying and assessing market barriers, creating a process evaluation methodology, and assisting utility companies in developing incentive programs. Furthermore, the preliminary baseline results from the case study demonstrate how the use of an independent monitoring system (IMS) can be used for ground-truth in evaluating FDD tools in the field.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

What are the Impacts on the HVAC System when it Provides Frequency Regulation? – A Comprehensive Case Study with a Multi-Zone Variable Air Volume (VAV) System

Heating, ventilation, and air-conditioning (HVAC) systems in commercial buildings have proven to be a great asset for providing secondary frequency regulation (FR) service to the power grid. However, how the provision of FR service affects the HVAC system Quality of Service (QOS) is still largely unknown. In particular, there exists a controversy regarding the energy efficiency impact. This paper investigates how a HVAC system performance and its associated controls are impacted during and after the FR service. For the assessment, we developed a dynamic Modelica-based medium office building model as a virtual testbed with the Air Handling Unit (AHU) fans providing the FR service. Different regulation capacities (demand levels) and standard test signals under various load profiles in the U.S. are considered. The results show that FR has little or no impact on the HVAC operation and occupant thermal comfort while the building is providing the service if an appropriate regulation capacity is pre-determined. However, if the regulation capacity is overestimated, the quality of the FR service provided by the HVAC system and the HVAC energy efficiency will be affected due to the equipment operating constraints. In addition, the AHU supply air temperature fluctuates, and the controller cannot maintain the desired setpoint as the FR magnitude is increased. After the FR service time, the system takes a certain period to return to normal operation. The recovery period extends with the increase in the FR magnitude. For this case study, there exists a control conflict between the FR control and the existing HVAC control (from ASHRAE Guideline 36-2018) during high load conditions, causing the fan speed to saturate. The fan power consumption could increase significantly; up to 77% increase compared to the baseline was observed. This case study demonstrates that the HVAC system controls need to be enhanced and adapted to minimize the interaction between the FR controller and the indoor environmental controls in order to preserve the HVAC system QOS while (during and after) providing satisfactory FR service.

Lu, Xing↗

Implementation and validation of optimal start control strategy for air conditioners and heat pumps

Commercial buildings are responsible for approximately 20 % of the total energy consumption and greenhouse gas emissions in the United States. Over 85 % of these buildings lack building automation systems, and many are small (<50,000 square feet), underserved, and use rooftop units (RTUs) for heating, ventilation, and air-conditioning needs. Because these buildings lack proper energy management systems, several operational deficiencies lead to excess energy consumption. Studies have shown that managing the RTUs’ heating and cooling set points, schedules, setbacks, and optimal start can result in a 20 % to 25 % reduction in electricity consumption in small commercial buildings. These buildings typically use fixed schedules to start the RTUs 60 to 120 min before occupancy begins, which results in excess energy consumption. This paper presents research that demonstrates and evaluates the performance of four optimal start methods, which utilize data-based modeling as a key element in facilitating adaptive control in response to time-varying inputs while requiring minimal sensor inputs. The evaluation found energy savings in two commercial buildings equipped with RTUs by periodically alternating four different optimal start models during the cooling and heating season. The resulting energy savings are positive for all models and range from 2 to 5 kWh/day/unit. The units on the east side of the building showed higher savings, while interior units showed greater variability in savings due to the differences in capacities and room sizes. Savings were considerably greater during the heating season compared to the cooling season. The performance of all four models on Mondays was poor; models suggested a shorter optimal start time, which resulted in relatively larger errors. Finally, the future work will look at using a different model for the days after weekends and holidays.

42 ENGINEERING↗

A data-driven network optimisation approach to coordinated control of distributed photovoltaic systems and smart buildings in distribution systems

The increasing integration of distributed energy resources, including demand-side resources and distributed photovoltaics (PVs), into distribution systems has resulted in more complicated power system operation. A data-driven network optimisation approach is proposed to coordinate the control of distributed PVs and smart buildings in distribution networks considering the uncertainties of solar power, outdoor temperature and heat gain associated with building thermal dynamics. These uncertain parameters have a significant impact on the operation and control of distributed PVs and smart buildings, bringing challenges to the distribution system operation. In the proposed data-driven distributionally robust optimisation (DRO) approach, the Wasserstein ball is used to construct an ambiguity set for the uncertain parameters, which does not require the probability distributions to be known. Furthermore, a conditional value-at-risk is incorporated into the Wasserstein-based DRO model and converted into a computationally tractable mixed-integer convex optimisation problem. Benchmarked with robust optimisation and chance-constrained programming, the proposed data-driven model can give a less conservative robust solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ATTRACTOR: Autonomy Teaming and TRAjectories for Complex Trusted Operational Reliability

Autonomous systems (AS) are crucial to realizing the vision of new, complex transportation modes, such as advanced air mobility (AAM) and urban air mobility (UAM). A chief barrier to induction of AS into aviation is insufficient understanding of AS reliability in time-critical and safety-critical environments—an obstacle to certification. ATTRACTOR is aimed at building a basis for certification of classes of autonomous cyber-physical-human systems (CPHS) via establishing metrics and models of trustworthiness and trust in multi-agent team interactions, analyzable trajectories, explainability of computational algorithms (explainable artificial intelligence, or XAI), and persistent modeling and simulation, in the context of missions planning and operation. By “building a basis for certification,” we mean acquiring an understanding of when a system is trustworthy and developing computable means to estimate trustworthiness and trust in order to eventually inform functional requirements that contribute to certification. The outcomes are applicable not just to aviation but to all domains that rely on autonomous systems.

Autonomy↗

Operational Assessment of Apollo Lunar Surface Extravehicular Activity

Quantifying the operational variability of extravehicular activity (EVA) execution is critical to help design and build future support systems to enable astronauts to monitor and manage operations in deep-space, where ground support operators will no longer be able to react instantly and manage execution deviations due to the significant communication latency. This study quantifies the operational variability exhibited during Apollo 14-17 lunar surface EVA operations to better understand the challenges and natural tendencies of timeline execution and life support system performance involved in surface operations. Each EVA (11 in total) is individually summarized as well as aggregated to provide descriptive trends exhibited throughout the Apollo missions. This work extends previous EVA task analyses by calculating deviations between planned and as-performed timelines as well as examining metabolic rate and consumables usage throughout the execution of each EVA. The intent of this work is to convey the natural variability of EVA operations and to provide operational context for coping with the variability inherent to EVA execution as a means to support future concepts of operations.

planning and scheduling↗

Real-Time Science Decisioning During High Tempo-High Intensity Mission Operations and the Role of Analogs

Introduction: NASA’s VIPER mission presents a unique operational paradigm within the history of robotic spaceflight. The proximity of the Moon to the Earth and the terrain elements (surface characteristics, light/shadow dynamics, communication links) of the lunar South Polar landing site create unprecedented operational conditions between these two planetary bodies. Apollo era lunar science and exploration included humans in situ to operate instruments and assimilate observational inputs in real-time. Previous lunar orbital missions have worked to operational timescales, e.g., decisional timelines and communication exchanges, that were weeks in length. Mars rover missions have worked to operational timescales, e.g., decisional timelines and communication exchanges between Mars and Earth, that were hours, days, and weeks in length. In the case of the VIPER mission, our operational decisioning for rover driving and instrument commanding will be compressed to minute-scale timeframes. These operational conditions directly impact the manner and speed with which the VIPER Science Team (VST) is required to synthesize and analyze data and produce timely science-driven decisions throughout surface mission operations. The VST shall provide mission enhancing scientific input to guide rover traverse planning and drill site confirmation and selection throughout surface operations. Further, the VST input will be of vital importance to the mission’s ability to maximize science return and to meet broader NASA objectives for future lunar in-situ resource utilization (ISRU)and exploration activities. The VST co-located in the Mission Science Center (MSC) will be responsive to the tactical operational cadence of the Mission Operations Center (MOC) and will provide further strategic and Long-Term Planning (LTP) guidance to the mission. The VIPER Science Operations & Integration(SO&I)team has developed an architecture that is focused on the infusion of science-decisioning into the operational framework and execution cadence of VIPER. NASA analog research has played a significant role in the construction of the VIPER science operations systems. As an example, the SO&I team has led analog missions that have focused on bringing together expertise in the sciences (natural, applied and social) and in operations in service of learning how to build and hold together interdisciplinary work environments and what tools are needed to support high tempo, high intensity integrated decisioning. These experiences have provided an essential foundation of knowledge to the VIPER team. Those analogs that specifically influenced the VIPER science operations construct were identified through a process of comparative analysis to prioritize those that offered relevance in whole or in part, and those that did not. The analog research output that provided extensibility to the VIPER science operations architecture included remote teams of humans and robots in cooperation (synchronous and asynchronous) with simulated earthbound systems, engineering and science teams, and the integrated assembly of tools that supported scientific analysis and data synthesis and provided infrastructure for the remote testing framework. Analogs which included real-time data monitoring, synthesis, visualization and access in a democratized and operationalized manner were of particular interest to the development of the VIPER MSC toolset both in terms of the technology and the processes used to develop the supporting infrastructure. We anticipate that each subsequent mission to the lunar south pole, whether with robots or humans, will be able to optimize science and exploration return by evolving strategies to infuse real-time collaborative science-decisioning. Furthermore, these efforts will result in a foundation for science operations development in support of human-robotic exploration of deep space and Mars. NASA analogs can continue to provide the opportunity to prepare, test and iterate on the operational concepts and tools that will support these ever-expanding space exploration efforts. Our presentation will include an overview of the VIPER Science Operations & Integration development process and specifics on what aspects of analog research have had a significant impact on our work systems.

D S S Lim↗

A software architecture for automating operations processes

The Operations Engineering Lab (OEL) at JPL has developed a software architecture based on an integrated toolkit approach for simplifying and automating mission operations tasks. The toolkit approach is based on building adaptable, reusable graphical tools that are integrated through a combination of libraries, scripts, and system-level user interface shells. The graphical interface shells are designed to integrate and visually guide a user through the complex steps in an operations process. They provide a user with an integrated system-level picture of an overall process, defining the required inputs and possible output through interactive on-screen graphics. The OEL has developed the software for building these process-oriented graphical user interface (GUI) shells. The OEL Shell development system (OEL Shell) is an extension of JPL's Widget Creation Library (WCL). The OEL Shell system can be used to easily build user interfaces for running complex processes, applications with extensive command-line interfaces, and tool-integration tasks. The interface shells display a logical process flow using arrows and box graphics. They also allow a user to select which output products are desired and which input sources are needed, eliminating the need to know which program and its associated command-line parameters must be executed in each case. The shells have also proved valuable for use as operations training tools because of the OEL Shell hypertext help environment. The OEL toolkit approach is guided by several principles, including the use of ASCII text file interfaces with a multimission format, Perl scripts for mission-specific adaptation code, and programs that include a simple command-line interface for batch mode processing. Projects can adapt the interface shells by simple changes to the resources configuration file. This approach has allowed the development of sophisticated, automated software systems that are easy, cheap, and fast to build. This paper will discuss our toolkit approach and the OEL Shell interface builder in the context of a real operations process example. The paper will discuss the design and implementation of a Ulysses toolkit for generating the mission sequence of events. The Sequence of Events Generation (SEG) system provides an adaptable multimission toolkit for producing a time-ordered listing and timeline display of spacecraft commands, state changes, and required ground activities.

Miller, Kevin J.↗

Passive cooling designs to improve heat resilience of homes in underserved and vulnerable communities

Disadvantaged communities face a growing threat to staying safe during heat waves, especially during coincident power outages. This study develops a methodology to evaluate the effectiveness of passive cooling measures (those that operate without power) to improve residential building heat resilience. Building performance is simulated for representative homes and on district scales in two disadvantaged communities in Fresno, California. Eleven passive measures are evaluated using four heat resilience metrics with and without grid power. Results show performance of the mitigation measures varies by building characteristics, surrounding environment, and power scenario. The two most effective measures were installing solar-control window films and adding roof insulation. For pre-1978 single-family homes, these two measures can reduce unmet degree-hours (UDH) indoors by 12% and 11% respectively without grid power, or 28% and 37% with grid power. Their respective UDH reductions at district scale typically range 8% — 20% and 4% — 12% without grid power, or 14% — 44% and 8% — 51% with grid power. Top floors have higher overheating risk than lower floors during extreme heat events with coincident power outages. Natural ventilation can help, reducing UDH by 21% — 26%. The methodology and findings from this study can help cities, communities, and utilities develop effective and targeted strategies to promote greater residential heat resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Climatology of the Vertical Profiles of Polarimetric Radar Variables and Retrieved Microphysical Parameters in Continental/Tropical MCSs and Landfalling Hurricanes

Most existing cloud models tend to overestimate the size of cloud ice particles and underestimate their concentration. This emphasizes the need to provide a reliable observational reference to optimize cloud model performance, particularly in areas of high concentration of ice at high altitudes. The dual-polarization radars give the community a unique opportunity to quantify cloud ice with a good accuracy using polarimetric radar retrievals. Here, in this study, we utilize the network of operational WSR-88D radars to build a climatology of the vertical profiles of radar variables, such as radar reflectivity Z, differential reflectivity Z DR , and specific differential phase K DP as well as the radar-retrieved vertical profiles of ice water content (IWC) above the melting layer and liquid water content below it, mean volume diameter D m , and total number concentration N t of ice and liquid particles. Such climatology was created for continental/marine mesoscale convective systems (MCSs) and tropical cyclones including hurricanes. The dataset includes 13 continental MCSs, 10 marine MCSs, and 11 tropical cyclones. Separate statistics of the “background” vertical profiles and the ones associated with high IWC aloft have been obtained in the course of this study. It is shown that continental MCSs exhibit larger size of ice in lower concentration aloft compared to the marine MCSs and especially tropical cyclones/hurricanes. A combination of high KDP and low Z aloft signifies lower D m , higher N t , and often substantial IWC.

54 ENVIRONMENTAL SCIENCES↗

Performance study of charcoal-based radon reduction systems for ultraclean rare event detectors

The continuous emanation of radon due to trace amounts of uranium and thorium in detector materials introduces radon to the active detection volume of low-background rare event search detectors. 222 Rn produces a particularly problematic background in the physics region of interest by the "naked" beta decay of its 214 Pb daughter nucleus. While charcoal-based adsorption traps are expected to be effective for radon reduction in auxiliary circulation loops that service the warm components of current ton-scale detectors at slow flow rates (0.5-2 SLPM), radon reduction in the entire circulation loop at high flow rates $\mathcal{O}$(100s SLPM) is necessary to reach high sensitivity in future generation experiments. In this article we explore radon dynamics with a charcoal-based radon reduction system in the main circulation loop of time projection chamber detectors. Here, we find that even for perfect radon traps, circulation speeds of 2,000 SLPM are needed to reduce radon concentration in a 10 ton detector by 90%. This is faster by a factor of four than the highest circulation speeds currently achieved in dark matter detectors. We further find that the effectiveness of vacuum swing adsorption systems, which have been employed very successfully at reducing atmospheric radon levels in clean-rooms, is limited by the intrinsic radon activity of the charcoal adsorbent in ultra-low radon environments. Adsorbents with significantly lower intrinsic radon activity than in currently available activated charcoals would be necessary to build effective vacuum swing adsorption systems operated at room temperature for rare event search experiments. If such VSA systems are cooled to about 190 K, this requirement relaxes drastically.

47 OTHER INSTRUMENTATION↗

Accelerating the Adoption of Energy Efficiency and Renewables in Warehouses and Distribution Centers

Commercial warehouses and storage facilities represent a large part of the commercial buildings in the United States, and their share increases every year. NREL is working with the U.S. Department of Energy to understand barriers, sector needs, and opportunities to enhance sustainability in the warehouse sector, driving ultra-high efficient, zero-energy design, while considering electrification in buildings and vehicles, grid-friendly operation, and decarbonization. After investigating literature about warehouse sustainability practices and high-performance warehouse case studies, several one-on-one interviews were carried out with warehouse managers and stakeholders. Data collected through literature and the interviews were captured to provide the current status of warehousing in the context of energy efficiency, renewables, carbon emissions, and overall sustainability. The results are intended to inform areas for new research and deployment activities to achieving zero energy and zero carbon goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Operational Energy Life Cycle Data Development for the National Institute of Standards And Technology (NIST) Building Industry Reporting and Design for Sustainability (BIRDS) Neutral Environmental Software Tool (NEST)

For this analysis, regionalized life cycle assessment (LCA) results for environmental impacts (using the Tool for Reduction and Assessment of Chemicals and Other Environmental Impacts [TRACI] 2.1) and cumulative energy demand (using the Federal Life Cycle Analysis Commons Elementary Flow List [FEDEFL] Inventory Methods v1.0.0) were evaluated for the production and utilization of electricity, natural gas, fuel oil, and propane as commodities within residential and commercial buildings. These results can used as a framework for future research into net zero, high-performance buildings, such as done here for the Building Industry Reporting and Design for Sustainability (BIRDS) database by the National Institute of Standards and Technology (NIST) Engineering Laboratory. The geographical results were assigned to each United States (U.S.) Zone Improvement Plan (ZIP) code based on the ZIP code location and corresponding Balancing Authority Area, natural gas basin, and Petroleum Administration for Defense Districts (PADDs). Additionally, previously developed models were utilized to develop future life cycle profiles. Projections were based on data available from the U.S. Energy Information Administration Annual Energy Outlook 2022 through 2050 (AEO 2022). Electricity LCA models were updated based on AEO 2022 projected annual generation mixes, while the natural gas baseline model was updated based on projected shares of natural gas types (conventional, shale, tight, and coalbed methane). Projections of crude oil production rates and export rates were applied to the petroleum baseline model in five-year increments to investigate their effects on the life cycle profile of fuel oil and propane. While only 100-year Global Warming Potential (GWP-100) with climate carbon feedback (CC-FB) and Cumulative Energy Demand are shown in Section 4: Results, the complete results, including Acidification Potential, Eutrophication Potential, Freshwater Ecotoxicity Potential, GWP-100 without inclusion of CC-FB, Human Health Impacts Potentials (Cancer, Non-Cancer), Ozone Depletion Potential, Particulate Matter Formation Potential, and Photochemical Smog Formation Potential, are tabulated for each ZIP code in the Excel worksheets that accompany this analysis. For the Excel spreadsheet tools associated with this report, please go to https://www.netl.doe.gov/energy-analysis/details?id=f8890fac-be55-44ac-aaa9-e2888bfabe93

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FINAL TECHINICAL REPORT THUNDERING BUFFALO HEALTH AND WELLNESS CENTER

This U.S. Department of Energy, Office of Indian Energy supported project consists of energy conservation measures (ECMs) and a solar photovoltaic (PV) system to reduce cost of utility bills in a newly constructed Fort Peck Wellness Center, for use by tribal members in improving their physical and mental wellness. Construction of the building was outside the scope of the DOE supported project. A new 2-story wellness center was designed and constructed in Poplar, Montana. The wellness center is comprised of fitness areas, gymnasium, pool and spa, offices, and BOH support areas. The building was completed and has been operational for more than a year. A final measurement and verification of energy savings was completed after one year of operation and the results are presented herein, showing an energy savings 20% higher than the originally models indicated.

14 SOLAR ENERGY↗

Atlantic Offshore Wind Transmission Study

The Atlantic Offshore Wind Transmission Study (AOSWTS) is part of the U.S. Department of Energy's (DOE) efforts to understand and facilitate the transmission of electricity from wind in the Atlantic Ocean. It was informed by the Atlantic Offshore Wind Transmission Literature Review and Gaps Analysis (Bothwell et al. 2021) and the convening workshops hosted in 2022-2023 by DOE and the U.S. Department of the Interior's Bureau of Ocean Energy Management. The study results help to inform An Action Plan for Offshore Wind Transmission Development in the U.S. Atlantic Region (Baker et al. 2023). DOE's Wind Energy Technologies Office funded AOSWTS. The AOSWTS identifies and evaluates pathways to enable offshore wind energy deployment in the Atlantic Ocean through coordinated offshore transmission solutions in the near term (by 2030) and long term (by 2050). The study fills gaps in prior analyses by providing a multiregional planning perspective that evaluates offshore wind generation development with transmission planning. It incorporates environmental, ocean co-use, and other siting considerations into defining potential offshore transmission routes. The study also compares different multiregional offshore transmission topologies and their associated costs (using potential cable routes) and benefits (in terms of production cost savings and enhanced resource adequacy). In addition, the AOSWTS analyzes reliability impacts from a multiregional perspective. The study provides guidance for policymakers and transmission stakeholders on possible outcomes resulting from a proactive, coordinated, and interregional approach to transmission planning for offshore wind energy development in the Atlantic. While this study presents possibilities, additional work following system operator methods and procedures can help build on this analysis.

17 WIND ENERGY↗

Atlantic Offshore Wind Transmission Study: Executive Summary

The Atlantic Offshore Wind Transmission Study (AOSWTS) is part of the U.S. Department of Energy's (DOE) efforts to understand and facilitate the transmission of electricity from wind in the Atlantic Ocean. It was informed by the Atlantic Offshore Wind Transmission Literature Review and Gaps Analysis (Bothwell et al. 2021) and the convening workshops hosted in 2022-2023 by DOE and the U.S. Department of the Interior's Bureau of Ocean Energy Management. The study results help to inform An Action Plan for Offshore Wind Transmission Development in the U.S. Atlantic Region (Baker et al. 2023). DOE's Wind Energy Technologies Office funded AOSWTS. The AOSWTS identifies and evaluates pathways to enable offshore wind energy deployment in the Atlantic Ocean through coordinated offshore transmission solutions in the near term (by 2030) and long term (by 2050). The study fills gaps in prior analyses by providing a multiregional planning perspective that evaluates offshore wind generation development with transmission planning. It incorporates environmental, ocean co-use, and other siting considerations into defining potential offshore transmission routes. The study also compares different multiregional offshore transmission topologies and their associated costs (using potential cable routes) and benefits (in terms of production cost savings and enhanced resource adequacy). In addition, the AOSWTS analyzes reliability impacts from a multiregional perspective. The study provides guidance for policymakers and transmission stakeholders on possible outcomes resulting from a proactive, coordinated, and interregional approach to transmission planning for offshore wind energy development in the Atlantic. While this study presents possibilities, additional work following system operator methods and procedures can help build on this analysis.

17 WIND ENERGY↗