Progress Report on the Spacecraft Atmosphere Monitor’s Development Model

The Spacecraft Atmosphere Monitor (S.A.M.) is a miniature gas chromatograph (GC) mass spectrometer (MS) intended for assessing trace volatile organic compounds and the major constituents in the atmosphere of present (the International Space Station) and future crewed spacecraft. As such, S.A.M. will continuously sample concentrations of major air constituents (CH4, H2O, N2, O2, and CO2) and report results in two-second intervals. The S.A.M. is a technology demonstration planned to launch in 2018 and we report here on recent developments taking place in building a testbed and development model of the instrument. The S.A.M. is mechanically designed to operate under hi-G loads present during launch events and can operate at sub-atmospheric pressures relevant to extra-vehicular activities. Total instrument mass is projected at 9.5 kg with power consumption estimated at 35 W. The S.A.M. instrument will provide on-demand reporting on trace volatile organic compounds (VOC) at ppm to ppb levels of 40+ species relevant for astronaut health.

Darrach, M.↗

Least-Cost Storage Mix for Low-Carbon Operations

As communities plan for high- or ultrahigh-renewable power systems, they face diverse options for energy storage. Each energy storage technology has a unique power capacity and discharge duration, and each community has a unique load, generation mix, and weather pattern. Determining the optimal storage portfolio across these parameters could save planners significant costs when building out high-renewable power systems.

analysis↗

End-Use Savings Shapes Measure Documentation: Boiler Replacement with Air-Source Heat Pump Boiler and Natural Gas Boiler Backup

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock (™) and ComStock (™) models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure - boiler replacement with air-source heat pump boiler with natural gas boiler backup. This measure replaces natural gas boilers for HVAC application by air-source heat pump boilers when applicable and use natural gas boiler backup when the heat pump boiler could not operate due to outdoor air conditions which are below its cutoff temperature. This measure helps to quantify the decarbonization as well as the energy savings potential from the replacement. The measure resulted higher savings in natural gas consumption compared to the increase in electricity consumption, with a ratio of 3. The total natural gas energy consumption was reduced by 41%, whereas the total electricity consumption was increased by 5.3%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multizone Residential HVAC Modeling

This report will evaluate several building physics modeling tools to determine which are best suited for developing next-generation zoning technology. These modeling tools will be evaluated for their ability to predict room-level thermal loads, HVAC system operation, temperature and comfort predictions, and scalability. Any gaps in the existing tools will be identified and a path forward will be discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Boiler Replacement with Air-Source Heat Pump Boiler and Electric Boiler Backup

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock TM and ComStock TM models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure—boiler replacement by air-source heat pump boiler. This measure replaces space heating natural gas boilers by air-source heat pump boilers when applicable and helps quantify the decarbonization as well as the energy savings potential from the replacement. The measure resulted higher savings in natural gas consumption compared to the increase in electricity consumption, with a ratio of 2.9. The total natural gas energy consumption was reduced by 20%, whereas the total electricity consumption was increased by 2.5%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Calculation of the Vertical Strata Load of Utility Tunnel Crossing Ground Fissure Zone

A ground fissure is a geological disaster in which the vertical dislocation of strata causes surface rupture. Ground fissures can cause extreme harm to the surface and underground buildings. Ground fissure activity can result in different settlement on the two sides of the strata, which will generate additional stress (pressure) that differs from the stress of the general stratum on underground structures across the ground fissure zone. It is essential to assess the effective stress of strata in the design of underground engineering structures across a ground fissure zone. The Xi’an ground fissure through a utility tunnel was focus of the research, and a physical model and data for oblique crossing of the 45° ground fissure were analyzed. A model of the utility tunnel structure was established, including the surrounding soil load as an active ground fissure environment. This model was used to calculate the vertical formation pressure of the overlying soil on the utility tunnel. A method to calculate the overlying load on the utility tunnel caused by ground fissure activity was proposed and compared with the calculation based on the A. Marston principle. The results showed that the ground fissure load calculation method based on the strata-holding effect can effectively calculate the earth pressure of the surrounding soil layer of the utility tunnel in the cross-ground fissure section. The results of this work provide guidance and reference value for the design of a utility tunnel in an area with the potential for a ground fissure.

Zhang, Dan↗

Constraining the release of Sn to the ambient melting point following shock loading using time-resolved x-ray diffraction

The formation of liquid following release from a shocked state governs the transition from spall to cavitation and the formation of ejecta in metals. In order to build physics-based models of these processes, it is necessary to critically evaluate the relative importance of kinetics and entropy generation during the release along with the accuracy of multiphase equations of state. Tin (Sn) has served as a testbed for a variety of experiments examining strength and ejecta due to its accessible melt boundary and solid–solid phase transitions. This work presents experiments examining the phase evolution of high purity Sn following the shock and release to ambient stress near the melting point. Sn is found to release to states between its ambient solidus and liquidus from approximately 19 to 33 GPa under uniaxial loading, with the two-phase region being characterized by a reduction in the intensity of the (220), (211) β -Sn doublet. Jetting experiments performed at 27–28 GPa exhibit comparable diffraction patterns with what is observed following the uniaxial release. The solid fractions of β-Sn in the ambient mixed phase region are found to decrease linearly with increasing shock stress as increasing liquid Sn is formed. Here, the results provide much needed information for interpreting measurements of dynamic strength at a high strain rate and experiments examining cavitation and shallow bubble collapse in Sn.

, spall↗

Community-Scale Energy Efficiency Assessment for Zero Net Energy Using the URBANopt Simulation Platform: Preprint

This project explored an innovative modeling approach for assessing the energy efficiency potential of the existing low-income Oceano neighborhood, in unincorporated San Luis Obispo County, and its effects on renewable generation requirements for achieving zero net energy (ZNE). One particular challenge faced was ascertaining the technical energy savings potential across a large neighborhood in a timely manner. The project overcame this challenge through the use of the URBANopt simulation platform, developed at the National Renewable Energy Laboratory. URBANopt manages the automated model creation, simulation, and result aggregation for different design scenarios of existing or candidate buildings in a large neighborhood. Customized energy efficiency packages considered for the residential and commercial sector in the neighborhood included lighting, HVAC, plug load, water heating, envelope, and energy education measures. As a result of the analysis for the Oceano community, energy efficiency measures that are available through incentive programs may provide a 7.4% reduction in the required distributed energy resource (DER) size, corresponding to a 25,000 ft2 decrease in PV array area, to achieve ZNE. Through this work, a computational tool was developed and is being leveraged by the County of San Luis Obispo (CoSLO). The tool has enabled the CoSLO staff to perform similar analysis of the technical potential for energy efficiency, and an understanding of the DER asset requirements and potential savings in other communities within the county.

building energy modeling↗

Case Study: NREL Campus Chilled Water Storage Potential: Benchmark Datasets Development and Applications, Task 4 - Use Case Demonstration

The Benchmark Datasets Development and Applications project is a three-year collaboration between the National Renewable Energy Laboratory (NREL), Oak Ridge National Laboratory, Pacific Northwest National Laboratory, and Lawrence Berkeley National Laboratory. The project seeks to collect and curate high-resolution, well-calibrated time series of building operational and indoor/outdoor environmental data, which are crucial to understanding and optimizing building energy efficiency performance and demand flexibility capabilities as well as benchmarking energy algorithms. Project outcomes include approximately twelve high-fidelity building datasets, enhanced data representation tools, and four case studies to illustrate example applications. The goal of these case studies is to define and execute analyses that demonstrate how one or more datasets collected through this project can address a data gap or challenge historically faced by building stakeholders. This technical paper summarizes the findings of one of these case studies, in which we studied the operational efficiencies of the central cooling system at NREL. We looked at three years of data from the three chillers in the Field Test Laboratory Building (FTLB), from 2019 to 2021, to compare equipment operation and demand throughout the time period. Our analysis indicates that all three chillers are operating at or below the optimal loading conditions for most of the operation time, and thus there was no efficiency drop due to loading of the chillers at full capacity. Our recommendation is that no chiller capacity increase is needed; instead, the central plant could benefit from adopting advanced control logics for optimal sequencing of chillers during part load operations. Analysis of adding chilled water thermal storage to the central plant indicated 34% savings in demand cost and 24.5% savings in total cost (energy consumption and demand charge cost). The payback period is estimated to be 11-22 years with an assumed TES cost of $\$$100-$200 per ton. This case study shows how a selected dataset is used to solve a practical building problem - learning the operational status of its components, analyzing the effectiveness of a proposed new technique, and aiding decision-making for the building operations and maintenance team.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Studsvik R2 materials test reactor Ad Hoc depletion strategy for the derivation of the fuel isotopic composition of the MPCMIV benchmark

The Ad Hoc Depletion Strategy elaborated by the NINE company, developed in support of the organization of the MPCMIV (Multi-physics Pellet Cladding Mechanical Interaction Validation) benchmark input and output specifications, is presented. This work aims at illustrating the strategy itself and then showing the results obtained with its application over the Studsvik R2 Testing Reactor, which is analyzed in the benchmark. The objective of the application of the strategy is to compute the fuel elements isotopic compositions at the beginning of some core loadings of interest for the benchmark. To this objective, it is necessary to implement first the simulation model of the three single assembly types and perform the infinite lattice depletions, then, to build the full core model and to perform the simulation of the core cycle. All the models and simulations were carried out with the use of the Monte Carlo particle transport code Serpent 2. Finally, the simulations results are assessed against Studsvik isotopic compositions of the fuel elements discharged from the R2 Reactor at the end of the core loading. Several assumptions were necessary during all the steps of the strategy, to overcome the lack of information regarding the core management. For this reason, the solution found at the end of the current analysis may not be completely optimized and further improvements regarding the model assumptions will be tested in a future work. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Residential Home Decarbonization Using Advanced Micro-CHP

An efficient micro-combined heat and power (CHP) prototype was developed to provide heat and electricity for single-family homes and light commercial buildings. The unit can be installed independently at the point of energy consumption. Consequently, it enables cost-effectively and flexibly matching heat and electrical loads, simplifying distribution and installation processes, and recovering and storing waste heat as hot water. The analyzed results show that the micro-CHP using natural gas as fuel achieves 10.68%–32.80% CO2 reduction in the selected five home applications. The potential effect of H2 on decarbonization of these home was also evaluated, finding that the micro-CHP using a blended fuel with H2 and natural gas can further reduce CO2 emissions. However, the 50% CO2 reduction in the micro-CHP requires at least 70%–90% of H2 in the blend with natural gas. Overall, the micro-CHP technology demonstrates a solid potential to accelerate micro-CHP adoption in residential and light commercial markets, thereby promoting broader micro-CHP acceptance and use in the future for building decarbonization.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

An economic and technical feasibility analysis of a dual-source heat pump using both the air and the ground

The study investigates the economic and technical performance of a novel dual-source heat pump (DSHP) compared with that of air-source heat pumps (ASHPs) and ground-source heat pumps (GSHPs). The DSHP can use both ambient air and the ground as a heat source or heat sink. It uses ambient air when its temperature is favorable for efficient heat pump operation. When the ambient temperature is too hot or cold, the ground source is used to retain high-efficiency heat pump operation. Since the DSHP can alternately use either the ground heat exchanger (GHE) or ambient air to meet the thermal load, the required size of GHE can be smaller than those of GSHPs. This study models the DSHP using a whole building energy simulation tool (EnergyPlus) coupled with a Python plug-in and Heat Pump Design Model (HPDM) to simulate its heating and cooling performance for a typical single-family home in 15 US climate zones. The required GHE size of the DSHP system is determined through simulations and compared with that of GSHPs. DSHP deployment can reduce electricity use compared to ASHPs, especially in cold climates where it shows a reduction of around 50%. When compared to GSHPs, DSHPs use 20%–40% more electricity in warm climates but consume around the same amount in moderate and colder climates. Since the DSHP can use air source when the ambient temperature is mild, the GHE size needed for the DSHP is about 40% less than that needed for GSHPs in hot climates and about 25% less in cold climates. In conclusion, the life cycle cost analysis shows that the DSHP is economically more feasible than ASHPs in colder regions and economically more feasible than GSHPs in hot and cold regions.

Dual-source heat pumps↗

Power Grid Simulation Testbed for Transactive Energy Management Systems

To effectively engage demand-side and distributed energy resources (DERs) for dynamically maintaining the electric power balance, the challenges of controlling and coordinating building equipment and DERs on a large scale must be overcome. Although several control techniques have been proposed in the literature, a significant obstacle to applying these techniques in practice is having access to an effective testing platform. Performing tests at scale using real equipment is impractical, so simulation offers the only viable route to developmental testing at scales of practical interest. Existing power-grid testbeds are unable to model individual residential end-use devices for developing detailed control formulations for responsive loads and DERs. Furthermore, they cannot simulate the control and communications at subminute timescales. To address these issues, this paper presents a novel power-grid simulation testbed for transactive energy management systems. Detailed models of primary home appliances (e.g., heating and cooling systems, water heaters, photovoltaic panels, energy storage systems) are provided to simulate realistic load behaviors in response to environmental parameters and control commands. The proposed testbed incorporates software as it will be deployed, and enables deployable software to interact with various building equipment models for end-to-end performance evaluation at scale.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Structural analysis for a 40-story building

NASTRAN was chosen as the principal analytical tool for structural analysis of the Illinois Center Plaza Hotel Building in Chicago, Illinois. The building is a 40-story, reinforced concrete structure utilizing a monolithic slab-column system. The displacements, member stresses, and foundation loads due to wind load, live load, and dead load were obtained through a series of NASTRAN runs. These analyses and the input technique are described.

Hua, L.↗

A widely adaptable habitat construction system utilizing space resources

This study suggests that the cost of providing accommodations for various manned activities in space may be reduced by the extensive use of resources that are commonly found throughout the solar system. Several concepts are proposed for converting these resources into simple products with many uses. Concrete is already being considered as a possible moonbase material. Manufacturing equipment should be as small and simple as possible, which leads to the idea of molding it into miniature modules that can be produced and assembled in large numbers to create any conceivable shape. Automated equipment could build up complex structures by laying down layer after layer in a process resembling stereolithography. These tiny concrete blocks handle compression loads and provide a barrier to harmful radiation. They are joined by a web of tension members that could be made of wire or fiber-reinforced plastic. The finished structure becomes air-tight with the addition of a flexible liner. Wire can be made from the iron modules found in lunar soil. In addition to its structural role, a relatively simple apparatus can bend and weld it into countless products like chairs and shelving that would otherwise need to be supplied from Earth. Wire woven into a loose blanket could be an effective micrometeoroid shield, tiny wire compression beams could be assembled into larger beams which in turn form larger beams to create very large space-frame structures. A technology developed with lunar materials could be applied to the moons of Mars or the asteroids. To illustrate its usefulness several designs for free-flying habitats are presented. They begin with a minimal self-contained living unit called the Cubicle. It may be multiplied into clusters called Condos. These are shown in a rotating tether configuration that provides a substitute for gravity. The miniature block proposal is compared with an alternate design based on larger triangular components and a tetrahedral geometry. The overall concept may be expanded to envision city-sized self-sufficient environments where humans could confortably live their entire lives. One such proposal is the Hive. It is configured around a unique sunlight collection system that could provide all its energy needs and that could be scaled up to compensate for the reduced solar intensity at greater distances from the sun. Its outer perimeter consists of a cylindrical section mated to two conical end walls that taper inwards toward a small aperture at the center of rotation. Light collected by two huge mirrors of unusual design enters the aperture and is redirected to the inside of the cylinder. The conical end walls are shielded from direct sunlight and are designed to radiate heat into space. They are lined with air ducts that passively recirculate the atmosphere while extracting moisture by condensation. Although there is no immediate demand for spacecraft on this scale, their consideration can influence even the earliest stages of the development process.

Wykes, Harry B.↗

Design and Analysis of the International X-Ray Observatory Mirror Modules

The Soft X-Ray Telescope (SXT) modules are the fundamental focusing assemblies on NASA's next major X-ray telescope mission, the International X-Ray Observatory (IXO). The preliminary design and analysis of these assemblies has been completed, addressing the major engineering challenges and leading to an understanding of the factors effecting module performance. Each of the 60 modules in the Flight Mirror Assembly (FMA) supports 200-300 densely packed 0.4 mm thick glass mirror segments in order to meet the unprecedented effective area required to achieve the scientific objectives of the mission. Detailed Finite Element Analysis (FEA), materials testing, and environmental testing have been completed to ensure the modules can be successfully launched. Resulting stress margins are positive based on detailed FEA, a large factor of safety, and a design strength determined by robust characterization of the glass properties. FEA correlates well with the results of the successful modal, vibration, and acoustic environmental tests. Deformation of the module due to on-orbit thermal conditions is also a major design driver. A preliminary thermal control system has been designed and the sensitivity of module optical performance to various thermal loads has been determined using optomechanical analysis methods developed for this unique assembly. This design and analysis furthers the goal of building a module that demonstrates the ability to meet IXO requirements, which is the current focus of the IXO FMA technology development team.

McClelland, Ryan S.↗

TPSAS-NF1676L-28151-DND

The proposed suborbital mission is to collect and analyze observations to help improve our ability to model and forecast these crucial monsoonal transports and their downstream effects. The objectives are 1) to observe and relate convective-scale to meso-scale changes in the three-dimensional circulation with the efficiency of the resulting convective transports (of air mass and heat) and the build-up of the large-scale anomalies, as they are modulated by the three-dimensional structure of the aerosol loading; and 2) to observe how fluctuations in the monsoon large-scale upper-level outflow affect downstream convection, especially within AEWs. The observations will be tailor-made to help understand the controls of the northward march of the monsoon isochrones, the initiation and magnitude of heat towers over the subcontinent during the monsoon, and how the mostly zonal land-sea differential heating interacts with the meridional progress of the Intertropical Convergence Zone (ITCZ) to constrain the intensities of the northern and western outflows. Unique contributions will be made by two airborne instruments, operated in concert: NASA-LARC's Doppler Aerosol Wind Lidar (DAWN) coherent-detection wind lidar which uses a pulsed laser with a wavelength of about two microns to measure vertical profiles of the three dimensional components of the wind field, and JPL's Airborne Second Generation Precipitation Radar (APR-2) precipitation radar which measures the three-dimensional structure of rain within a swath that is about10km wide (depending on the altitude of the plane) and extends from flight level down to the surface.

Upendra N Singh↗

Smarter building start – A distributed solution

A significant focus of research and new technologies for reducing energy use in buildings is on operating the systems more efficiently during the times when the systems are active. However, there is a large potential for energy savings in determining the periods when the systems should or should not be active. This scheduling aspect of operation is often overlooked even though relatively simple solutions can unlock substantial energy savings. In this paper we describe a smart building start (SBS) algorithm that considers multiple zones in a building to determine individual schedules for room controllers as well as the central systems based on solving a simple optimization problem. Application of the SBS algorithm to multiple interconnected systems enables a staggered start-up that minimizes peak loads and also ensures comfort is within a target range with minimal system run time. The SBS algorithm extends the capability of traditional optimal start and is designed to be simple to deploy and robust. Simulation results as well as results from tests in a real building with a VAV system are presented. The presented algorithm is applicable to any type of building with a zonal or multi-zone HVAC system. To function, it needs to be able to change setpoints in rooms and monitor room temperatures, as well as, if desired, turn the central system on or off.