Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building energy simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Peak load reduction and load shaping in HVAC and refrigeration systems in commercial buildings by using a novel lightweight dynamic priority-based control strategy

Reducing peak power demand in a building can reduce electricity expenses for the building owner and contribute to the efficiency and reliability of the electrical power grid. For the building owner, reduced expenses come from the reduction or elimination of peak power charges on electricity bills. For the power system operator, reducing peak power demand leads to a more predictable load profile and reduces stress on the electric grid system. Herein we present a computationally inexpensive, dynamic, and retrofit-deployable control strategy to effect peak load reduction and load shaping. The effectiveness of the control strategy is examined in a simulation with 80 air-conditioning units and 40 refrigeration units. The results show that a peak demand reduction of 60 kW can be achieved relative to peak demand in a typical set point–based approach. The proposed strategy was deployed in a gymnasium building with four rooftop HVAC units, where it showed over 15% peak demand (kW) reduction savings while maintaining or lowering energy consumption (in kilowatt-hours) relative to the set point–based thermostat controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hotel Room Computational Fluid Dynamics to Investigate Airborne Pathogen Dispersal Patterns

A hotel room unit consisting of a bedroom and bathroom was modelled using computational fluid dynamics (CFD) to investigate airborne pathogen dispersal patterns. The full-scale model includes a ‘typical’ hotel room configuration, furniture, and vents. The air sources and sinks include a bathroom vent, a heating, ventilation, and cooling (HVAC) unit located in the bedroom, and a ½” gap at the bottom of the entry door. In addition, the entry door and window can be opened or closed, as desired. Three key configuration simulations were conducted: 1) both the bathroom vent and HVAC were on, 2) only the HVAC was on, and 3) only the bathroom vent was on. If the HVAC air is from a fresh, clean source, or passes through a high-efficiency filter/UV device, then the first configuration is the safest, as contaminated air is highly reduced. The second configuration is also safe, but does not benefit from the outsourcing of potentially-infected air, such as contaminated air flowing through an ineffective filter. The third configuration should be avoided, as the bathroom vent causes air to flow from the hallway, which can be of dubious origin. The CFD simulations also showed that recirculation and swirling regions tend to accumulate the largest concentrations of heavier airborne particles, pathogens, dust, etc. These regions are associated with the largest turbulence kinetic energy (TKE) , and tend to occur in areas with flow recirculation and corners. Therefore, TKE presents a reasonable metric to guide the strategic location of pathogen mitigation devices. The simulations show complex flow patterns with distinct upper and lower flow regions, swirling flow, and significant levels of turbulent mixing. These simulations provide intriguing insights that can be applied to help mitigate pathogen aerosol dispersal, generate building design guidelines, as well as provide insights for the strategic placement of mitigation devices, such as ultraviolet (UV) light, supplemental fans, and filters.

54 ENVIRONMENTAL SCIENCES↗

Analytical Modeling of Planetary Excavation for in Situ Resource Utilization

The space-faring capabilities of humans are dependent on the ability to interact with plan-etary surfaces safely and efficiently and utilize local re-sources. Since planetary regolith will be the primary feedstock for in situ resource utilization (ISRU) and infrastructure development activities [1,2], the site-specific geomechanical properties must be understood to optimize excavation operations [3]. Excavating planetary regolith is challenging due to its unique geomechanical properties, 1/6th G reduced gravity extreme conditions, and limited energy resources. Therefore, it is critical to develop technologies that reduce excavation force requirements and minimize tool path inefficiencies to save time and energy during planetary re-source acquisition and infrastructure development [3]. There have been several experimental investigations of methods to optimize planetary excavations [4,5], but none developed predictive capabilities. This abstract presents a simple analytical method that will be used to model laboratory and mission excavation data. Future work will build on the simple analytical method here to include high-fidelity numerical simulations of planetary excavation mechanics.

Regolith↗

Integrated Spatial, Spectral, & Temporal Optical Reflectance System for Precision Occupancy & Location Sensing to Improve Building Energy Efficiency

Buildings consume approximately 35% of the electricity used in the U.S. and building owners can significantly reduce this energy use by providing services like heating, electrical power and lighting only when people are present. The ARPAe funded program titled “INTEGRATED SPATIAL, SPECTRAL, & TEMPORAL OPTICAL REFLECTANCE SYSTEM FOR PRECISION OCCUPANCY & LOCATION SENSING TO IMPROVE BUILDING ENERGY EFFICIENCY” demonstrates how a low cost sensor technology developed for measuring distances can be used to count and locate occupants with a high degree of precision with a very low error rates. This platform tells a building control system where occupants are located (but not who they are) so that energy consuming services can be provided only when the services are needed by building occupants. The original proof of concept involved using low cost, commercially available time-of-flight (TOF) sensors that measure distance, but the performance of these existing sensors was lacking, as they could not operate properly in the presence of sunlight, which blinded the simple TOF sensors and limited their utility in buildings. This project proposed a powerful new class of TOF sensors that used state-of-the-art integrated circuit (IC) fabrication processes that combined advanced photonics with conventional silicon chip circuitry for improved sensor performance. An equally important part of this project was to find ways to maximize occupant count and location accuracy while using the fewest number of sensors possible, in order to keep costs low. By using building blueprints to create digital twins of commercial building spaces, the team developed new algorithms to maximize occupant count and tracking accuracy by properly locating the minimum number of sensors at just the right spots in the building. This capability not only minimizes system costs but also simplified sensor installation and system commissioning. Our simulations of our sensor networks for a range of commercial floorplan designs demonstrated that our installed cost target of $0.08/sqft was attainable, though not fully demonstrated during the project. Finally, we noted that the TOF sensor concept could provide a valuable role in health and eldercare by tracking patients without the need for worn sensors and would be useful for fall detection and other patient safety metrics, including tracking healthcare/patient interactions. We feel that, when fully developed, this new class of sophisticated TOF sensors and support software will be a powerful new approach to improving building energy efficiency based on occupant centric control platforms and will also open new levels of patient safety in healthcare operations. To realize this potential, the team formed the Troy Sensor Company LLC to oversee licensing of the programs patents and continue to seek commercialization of this program’s activity sensing technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fast Grid Frequency Support from Distributed Energy Resources

This report describes research related to electric power system frequency support from inverter-coupled distributed energy resources (DERs). This research was initiated under the U.S. Department of Energy’s Grid Modernization Laboratory Consortium (GMLC) and also contains work funded through a Cooperative Research and Development Agreement with Hawaiian Electric. The purpose of this report is to summarize the findings of simulations, hardware testing, power hardware-in-the-loop (PHIL) simulation, and analysis examining the effects of DER frequency support on the Oahu power system. This report also includes recommendations for consideration in the use of DER grid frequency support functionality, and related topics. Note that a previous GMLC Technical Report from this project also provided specific recommendations for the activation of one specific grid frequency support function, frequency-watt control, for overfrequency events in Hawaii. Those recommendations included recommended frequency-watt control settings, which have since been approved by the Hawaii Public Utilities Commission on October 20, 2017, for system-wide activation. This report builds on the previous report by considering not only overfrequency events but also underfrequency events, and by considering distributed energy storage systems in addition to photovoltaic (PV) systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Volumetric energy density impact on mechanical properties of additively manufactured 718 Ni alloy

The 718 Ni-based superalloy has gained enormous attention in the additive manufacturing community for its great weldability, allowing for complex geometries to be formed, and its superb mechanical strength. Here we explore the influence of a wide range of major build parameters on microstructures and mechanical properties of 718 Ni alloys. Volumetric energy density appears to be one of the major parameters that captures the relationship between energy input and measured mechanical properties and microstructures of the alloys. A threshold energy density was identified below which the properties of the additively manufactured specimen degrade substantially. Finally, the influence of energy density on the quality of the built specimen simulated using Flow3D AM correlates well with the experimental results.

36 MATERIALS SCIENCE↗

Direct Observations of Solute Dispersion in Rocks With Distinct Degree of Sub‐Micron Porosity

Abstract The transport of chemical species in rocks is affected by their structural heterogeneity to yield a wide spectrum of local solute concentrations. To quantify such imperfect mixing, advanced methodologies are needed that augment the traditional breakthrough curve analysis by probing solute concentration within the fluids locally. Here, we demonstrate the application of asynchronous, multimodality imaging by X‐ray computed tomography (XCT) and positron emission tomography (PET) to the study of passive tracer experiments in laboratory rock cores. The four‐dimensional concentration maps measured by PET reveal specific signatures of the transport process, which we have quantified using fundamental measures of mixing and spreading. We observe that the extent of solute spreading correlate strongly with the strength of subcore‐scale porosity heterogeneity measured by XCT, while dilution is enhanced in rocks containing substantial sub‐micron porosity. We observe that the analysis of different metrics is necessary, as they can differ in their sensitivity to the strength and forms of heterogeneity. The multimodality imaging approach is uniquely suited to probe the fundamental difference between spreading and mixing in heterogeneous media. We propose that when multi‐dimensional data is available, mixing and spreading can be independently quantified using the same metric. We also demonstrate that one‐dimensional transport models have limited predictive ability toward the internal evolution of the solute concentration, when the model is solely calibrated against the effluent breakthrough curves. The data set generated in this study can be used to build realistic digital rock models and to benchmark transport simulations that account deterministically for rock property heterogeneity.

Kurotori, Takeshi [Department of Chemical Engineer↗

CLMM : a LSST-DESC cluster weak lensing mass modeling library for cosmology

ABSTRACT We present the v1.0 release of CLMM, an open source python library for the estimation of the weak lensing masses of clusters of galaxies. CLMM is designed as a stand-alone toolkit of building blocks to enable end-to-end analysis pipeline validation for upcoming cluster cosmology analyses such as the ones that will be performed by the Vera C. Rubin Legacy Survey of Space and Time-Dark Energy Science Collaboration (LSST-DESC). Its purpose is to serve as a flexible, easy-to-install, and easy-to-use interface for both weak lensing simulators and observers and can be applied to real and mock data to study the systematics affecting weak lensing mass reconstruction. At the core of CLMM are routines to model the weak lensing shear signal given the underlying mass distribution of galaxy clusters and a set of data operations to prepare the corresponding data vectors. The theoretical predictions rely on existing software, used as backends in the code, that have been thoroughly tested and cross-checked. Combined theoretical predictions and data can be used to constrain the mass distribution of galaxy clusters as demonstrated in a suite of example Jupyter Notebooks shipped with the software and also available in the extensive online documentation.

79 ASTRONOMY AND ASTROPHYSICS↗

pvlib python: 2023 project update

pvlib python is a community-developed, open-source software toolbox for simulating the performance of solar photovoltaic (PV) energy components and systems. It provides reference implementations of over 100 empirical and physics-based models from the peer-reviewed scientific literature, including solar position algorithms, irradiance models, thermal models, and PV electrical models. In addition to individual low-level model implementations, pvlib python provides high-level workflows that chain these models together like building blocks to form complete “weather-to-power” photovoltaic system models. It also provides functions to fetch and import a wide variety of weather datasets useful for PV modeling. pvlib python has been developed since 2013 and follows modern best practices for open-source python software, with comprehensive automated testing, standards-based packaging, and semantic versioning. Its source code is developed openly on GitHub and releases are distributed via the Python Package Index (PyPI) and the conda-forge repository. pvlib python’s source code is made freely available under the permissive BSD-3 license. Here we (the project’s core developers) present an update on pvlib python, describing capability and community development since our 2018 publication (Holmgren, Hansen, & Mikofski, 2018).

14 SOLAR ENERGY↗

Double-differential Measurements of Mesonless Charged-current Muon Neutrino Interactions on Argon with Final-State Protons using the MicroBooNE Detector

This note reports the first double-differential measurements of charged-current $ν_µ$ scattering on argon leading to final states containing zero mesons and one or more protons. This event topology (hereafter abbreviated as CC0$πNp$) is the most common at the neutrino energies typically produced by the Fermilab Booster Neutrino Beam. A detailed understanding of neutrino-argon scattering in the CC0$πNp$ channel is therefore crucial for the success of the precision neutrino oscillation analyses planned for the Short-Baseline Neutrino (SBN) program. This remains true for the upcoming Deep Underground Neutrino Experiment (DUNE), but the higher mean neutrino energy used there will ensure that more inelastic reaction modes, such as single pion production, will also play a major role. The analysis described in this note builds on a previous MicroBooNE study of the CC0$πNp$ channel which obtained the first single-differential cross-section measurements on an argon target. Since that foundational work, significant improvements have been made to MicroBooNE’s simulation software, event reconstruction algorithms, and procedure for calculating systematic uncertainties. When combined with a larger dataset (corresponding to a beam exposure of 6.79 × 10 20 protons-on-target versus 1.60 × 10 20 in Ref. [3]), these enhancements allow the important CC0$πNp$ channel to be studied in more detail. This note begins with a description of the data and simulation samples used as input to the analysis. Section 3 then defines the CC0$πNp$ signal event topology, and Section 4 describes a set of selection criteria designed to identify these events in MicroBooNE data. Binning schemes are then defined in Section 5 for two double-differential measurements of event rates. The first of these considers the momentum and scattering cosine of the outgoing muon, while the second reports the same observables for the leading proton, i.e., the final-state proton with the largest momentum. After a discussion of systematic uncertainties in Section 6, the note concludes by comparing the predictions of MicroBooNE Monte Carlo (MC) simulations to the measured double-differential distributions. These results will form the basis for a future extraction of flux-averaged double-differential CC0$πNp$ cross sections that will be immediately comparable to the theoretical predictions of multiple neutrino event generators. The selection described herein may also be used to study various other observables in CC0$πNp$ events, including those which are sensitive to correlations between leptonic and hadronic kinematics in the final state.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Energy transfer in compressible turbulence

This letter investigates the compressible energy transfer process. We extend a methodology developed originally for incompressible turbulence and use databases from numerical simulations of a weak compressible turbulence based on Eddy-Damped-Quasi-Normal-Markovian (EDQNM) closure. In order to analyze the compressible mode directly, the well known Helmholtz decomposition is used. While the compressible component has very little influence on the solenoidal part, we found that almost all of the compressible turbulence energy is received from its solenoidal counterpart. We focus on the most fundamental building block of the energy transfer process, the triadic interactions. This analysis leads us to conclude that, at low turbulent Mach number, the compressible energy transfer process is dominated by a local radiative transfer (absorption) in both inertial and energy containing ranges.

Bataille, Francoise↗

Facesheet Delamination of Composite Sandwich Materials at Cryogenic Temperatures

The next generation of space transportation vehicles will require advances in lightweight structural materials and related design concepts to meet the increased demands on performance. One potential source for significant structural weight reduction is the replacement of traditional metallic cryogenic fuel tanks with new designs for polymeric matrix composite tanks. These new tank designs may take the form of thin-walled sandwich constructed with lightweight core and composite facesheets. Life-time durability requirements imply the materials must safely carry pressure loads, external structural loads, resist leakage and operate over an extremely wide temperature range. Aside from catastrophic events like tank wall penetration, one of the most likely scenarios for failure of a tank wall of sandwich construction is the permeation of cryogenic fluid into the sandwich core and the subsequent delamination of the sandwich facesheet due to the build-up of excessive internal pressure. The research presented in this paper was undertaken to help understand this specific problem of core to facesheet delamination in cryogenic environments and relate this data to basic mechanical properties. The experimental results presented herein provide data on the strain energy release rate (toughness) of the interface between the facesheet and the core of a composite sandwich subjected to simulated internal pressure. A unique test apparatus and associated test methods are described and the results are presented to highlight the effects of cryogenic temperature on the measured material properties.

Gates, Thomas S.↗

Quantification of Energy Savings and Demand Reduction for a Heat Pump Integrated with Thermal Energy Storage (Final Report)

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. The study in this report is conducted by ORNL with collaboration with Emerson the Helix Innovation Center. In the first part of this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. The study suggests that the traditional value analysis that focuses on ROI for the building owner significantly undervalues TES technology making economic viability difficult. A more comprehensive value analysis that includes peak demand management and deferred capital for peaking power plants shows that TES should be economically viable but here the value is greater for the utility and requires large market penetration and aggregation to fully realize the benefits. Therefore, to facilitate commercialization, new business models are needed that include a broader range of stakeholders and distribute the value of TES proportionally. In the 2 nd part of this project, the benefits of a novel phase change material (PCM) integrated heat pump configuration were evaluated via detailed component based simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation. To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation of District Energy Microgrids Planning Tool for Non-Technical Users

Community Microgrids are increasingly gaining popularity worldwide for their efficiency, cost-effectiveness, and local resilience improvement. Microgrid planning tools play a crucial role in their deployment. In the process, tentative designs of the microgrid are simulated, analyzed, and optimized. Due to the complexity of the problem, planning tools must carefully balance computational efficiency while seeking the most optimal solutions. This paper investigates the impact of algorithm selection on CPU and memory utilization of a Community Microgrid planning tool that is specifically designed for non-technical users. We compare two version of the code with two alternatives for Community Microgrid planning tools: a Greedy Algorithm, and a Linear Programming Approach. This comparison examines scenarios spanning from 2 to 50 buildings. Our findings revealed a significant difference in performance between the two algorithms, underscoring the critical role of algorithm selection in optimizing the efficiency of Community Microgrid Planning Tools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GCAM-USA: IM3 Phase 2 Official Simulations

Overview GCAM-USA simulates 21st century energy-water-land interactions in global regions with sub-national detail in the United States (US). The IM3 project is focused on US multisector dynamics and has created eight GCAM-USA simulations by combining two Shared Socioeconomic Pathways (SSP3 and SSP5) with four high-resolution climate projections specific to the United States (see https://tgw-data.msdlive.org/). These climate projections include "hotter" and "cooler" variants for two Representative Concentration Pathways (RCP4.5 and RCP8.5). The resulting eight GCAM-USA simulations are named: rcp45cooler_ssp3 rcp45cooler_ssp5 rcp45hotter_ssp3 rcp45hotter_ssp5 rcp85cooler_ssp3 rcp85cooler_ssp5 rcp85hotter_ssp3 rcp85hotter_ssp5 Detailed Assumptions The SSPs describe alternative socioeconomic futures and their implications for both the US and global environmental challenges. As implemented in GCAM-USA, the primary difference between SSP3 and SSP5 in the US is their population growth projections, with SSP3 foreseeing lower growth and SSP5 projecting higher growth. The four climate projections explore moderate (RCP4.5) and high (RCP8.5) greenhouse gas emission (GHG) trajectories, each with a hotter and cooler climate variation based on the range of global climate model simulations in CMIP6s. These four climate projections are used in precursor models to develop climate impacts on building heating and cooling degree-hours, water availability, and agricultural yields that are provided as inputs to GCAM-USA. GCAM-USA reproduces the RCP4.5 and RCP8.5 GHG emissions trajectories consistent with each climate projection, using dynamic carbon prices to achieve RCP4.5. When the four climate projections are combined with the two SSP projections, the resulting eight scenarios allow GCAM-USA to explore how a wide, yet plausible, range of climate and socioeconomic impacts affects the interconnected energy, water, and land systems across the contiguous United States. Technical Details IM3 uses a version of GCAM-USA v5.3 that has an enhanced electricity sector and an updated data system needed to represent regional to local scale dynamics.

IM3↗

What is the Right Size for a Residential Building Parcel Locker?

Common-carrier parcel lockers present a solution for decreasing delivery times, traffic congestion, and emissions in dense urban areas through consolidation of deliveries. Multi-story residential buildings with large number of residents, and thus a high volume of online package orders, are one of the best venues for installing parcel lockers. But what is the right size for a residential building locker that would suit the residents’ and building managers’ needs? Because of the novelty of parcel lockers, there is no clear guideline for determining the right locker size and configuration for a residential building given the resident population. A small locker would result in packages exceeding capacity and being left in the lobby, increasing the building manager’s workload and confusing and inconveniencing users. On the other hand, a large locker is more expensive, more difficult to install, and unappealing to residents. To answer this question, we installed a common-carrier parcel locker in a residential building in downtown Seattle, WA, U.S.A. Through collecting detailed data on locker usage from the locker provider company, we studied and quantified carriers’ delivery patterns and residents’ online shopping and package pickup behaviors. We then used this information to model the locker delivery and pickup process, and simulated several locker configurations to find the one that best suits the delivery needs of the building. These findings could aid urban planners and building managers in choosing the right size for residential building lockers that meet delivery demand while minimizing costs and contributing to environmental benefits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A systematic feature extraction and selection framework for data-driven whole-building automated fault detection and diagnostics in commercial buildings

In data-driven automated fault detection and diagnostics (AFDD) modeling for building energy systems, feature engineering is a critical process of extracting information from high-dimensional and noisy sensor measurement and turning it into informative and representative inputs or features for data-driven modeling. However, few studies specifically discuss the feature engineering, especially the interactions between feature extraction and feature selection in whole-building AFDD. We developed a systematic feature extraction and selection framework for whole-building AFDD. In this framework, features are aggressively extracted from raw sensor data using statistical feature extraction techniques with various window sizes and statistics. With many features extracted, a hybrid feature selection algorithm that combines the filter and wrapper method then selects the best feature set. The framework considers diversity in the duration of fault behavior among fault types in whole-building AFDD, thus achieving high model generalization. We implemented our developed framework in a virtual testbed calibrated with measured data from Oak Ridge National Laboratory's Flexible Research Platform designed to mimic the operation of a typical small commercial building. The AFDD model is trained by the simulation data generated from the virtual testbed. The results show that (1) the developed framework improves the generalization of the AFDD model by 10.7% compared with literature-reported feature extraction and selection methods and (2) features with diverse window sizes and statistics are selected, providing insight into physical systems beyond the current understanding of buildings and faults and improving the detection and diagnostics of multiple fault types.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Interactive Gas Chemistry for Enhanced Science Capabilities of the Energy Exascale Earth System Model Version 3

Atmospheric chemistry plays a crucial role in Earth system models (ESMs), controlling atmospheric composition and radiative balance; it is highly interactive with the physical climate, biogeochemical cycles, and human systems. However, it often imposes computational challenges in an ESM. Here we develop a full troposphere‐stratosphere interactive chemistry module for the US Department of Energy's Energy Exascale Earth System Model (E3SM). We intentionally build a streamlined module based on E3SM version 2 that interacts with other components and maintains all of major chemical and chemistry‐climate feedbacks. The module incorporates a new, highly efficient tracer advection scheme; linearization of stratospheric chemistry; and abridged tropospheric chemical mechanism with 28 reactive tracers. This new model, E3SM‐chem, can readily perform century‐long climate simulations of ozone, methane, and nitrous oxide based on emission scenarios as well as provide hourly budgets for the gas‐phase radicals that drive aerosol chemistry. We evaluate E3SM‐chem with an atmosphere‐only simulation as in the recent climate model intercomparison project (CMIP6) finding results similar to the other CMIP6 models. For the present‐day, E3SM‐chem matches the standard measurement metrics for stratospheric and tropospheric ozone, surface air quality, other key reactive gases like carbon monoxide, and the methane lifetime. Overall, E3SM‐chem maintains the climate fidelity of the baseline model while adding at most 20% to the computational cost of the atmosphere model. Hence, interactive chemistry can be a default configuration for long climate simulations at resolutions of 1° or finer, which is crucial for producing self‐consistent chemistry‐climate feedbacks that alter the climate system.

54 ENVIRONMENTAL SCIENCES↗