Summary of investigation

Summary of design, construction, test results, and weight comparison of jettisonable and nonjettisonable insulation systems for liquid hydrogen propellant tanks

LIQUID HYDROGEN↗

Insulation concept

Constrictive wrap sealed foam insulation system for liquid hydrogen tanks of rocket boost vehicles

FOAMED MATERIAL↗

Non-flammable polyimide materials for aircraft and spacecraft applications

Recent developments in polyimide chemistry show promise for producing materials with very low flammability and a wide range of mechanical properties. Polyimide foams can be synthesized to provide fire safety without detectable formation of smoke or toxic byproducts below 204 C (400 F), thus avoiding an environment which is lethal to human habitation. This work has been and is currently being performed under development programs, the objective of which is to provide cost effective processes for producing thermally stable, polyimide flexible resilient foams, thermal-acoustical insulating materials, rigid low density foam panels, and high strength foam structures. The chemical and physical properties demonstrated by these materials represent a technological advancement in the art of thermally stable polyimide polymers which are expected to insure fire protection of structures and components used in air transportation and space exploration. Data compiled to date on thermal, physical and functional properties of these materials are presented.

Gagliani, J.↗

An analytical study of reusable flight-weight cryogenic propellant tank designs

Thermostructural analyses of reusable flight-weight cryogenic tanks for a vertically launched space vehicle have been conducted. An analytical procedure was developed for sizing the tank structure, cryogenic insulation, and thermal protection system. Unstiffened, integrally-stiffened, and honeycomb core sandwich tank skins using aluminum or stainless steel materials were compared for their ability to meet design criteria at least weight. Cryogenic insulation systems were also evaluated, including closed-cell cryogenic foams and evacuated honeycomb core. The results indicate that a 400 F foam-insulated unstiffened-skin aluminum tank structure is the lightest structure for either LOX or LH2 tanks that meet the selected design criteria, but only two to four percent lighter than a stiffened aluminum tank.

Taylor, A. H.↗

Thermal response of advanced high temperature ceramic-composite insulation to a convectively heated environment

The Space Shuttle uses currently fibrous high temperature, reusable surface insulation (HRSI) as a Thermal Protection System (TPS) at 1260 C for normal-design mission operation. Higher density material of a similar type extended the maximum temperature to 1480 C. However, a surface temperature capability exceeding 1540 C is desired for future space vehicles, such as the Orbital Transfer Vehicle (OTV). A TPS providing such a capability would permit future entry vehicles to enter the atmosphere at a much higher velocity than the Space Shuttle. The present investigation is concerned with arc-jet test data obtained from a family of fibrous refractory-composite insulation (FRCI) materials developed to meet the future TPS requirements. FRCI materials containing between 20 and 80 percent aluminoborosilicate fibers with the balance composed of silica fibers were studied.

Stewart, D. A.↗

Significance of Landsat-7 Spacecraft Level Thermal Balance and Thermal Test for ETM+Instrument

The thermal design and the instrument thermal vacuum (T/V) test of the Landsat-7 Enhanced Thematic Mapper Plus (ETM+) instrument were based on the Landsat-4, 5 and 6 heritage. The ETM+ scanner thermal model was also inherited from Landsat-4, 5 and 6. The temperature predictions of many scanner components in the original thermal model had poor agreement with the spacecraft and instrument integrated sun-pointing safehold (SPSH) thermal balance (T/B) test results. The spacecraft and instrument integrated T/B test led to a change of the Full Aperture Calibrator (FAC) motor stack "solar shield" coating from MIL-C-5541 to multi-layer insulation (MLI) thermal blanket. The temperature predictions of the Auxiliary Electronics Module (AEM) in the thermal model also had poor agreement with the T/B test results. Modifications to the scanner and AEM thermal models were performed to give good agreement between the temperature predictions and the test results. The correlated ETM+ thermal model was used to obtain flight temperature predictions. The flight temperature predictions in the nominal 15-orbit mission profile, plus margins, were used as the yellow limits for most of the ETM+ components. The spacecraft and instrument integrated T/B and TN test also revealed that the standby heater capacity on the Scan Mirror Assembly (SMA) was insufficient when the Earth Background Simulator (EBS) was 1 50C or colder, and the baffle heater possibly caused the coherent noise in the narrow band data when it was on. Also, the cooler cool-down was significantly faster than that in the instrument T/V test, and the coldest Cold Focal Plane Array (CFPA) temperature achieved was colder.

Choi, Michael K.↗

Prediction of pressure during evacuation of multilayer insulation.

Description of an improved analytical procedure for predicting the pressure time history during evacuation of multilayer-insulation thermal-protection systems. To evaluate the performance of the proposed analysis and to demonstrate its usefulness as a design tool, a comparison is presented of the experimentally measured and predicted evacuation pressure histories for a laboratory-scale model multilayer insulation blanket.

Glassford, A. P. M.↗