Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Faster ablative Kelvin–Helmholtz instability growth in a magnetic field

Shear flows along a plasma interface will quickly grow unstable due to the Kelvin–Helmholtz instability. If there is a concurrent temperature gradient across the interface, higher modes are stabilized by the thermal diffusion. These ablative effects must be considered in, for example, jet features in inertial confinement fusion hot-spots, or plasma plumes in young supernovae. We show that magnetization of the plasma can greatly affect the instability, even if magnetic pressure is small. This is because electrons are localized by their gyromotion, reducing the heat flux and material ablation. We use a two-dimensional numerical extended-magnetohydrodynamics approach to assess this effect for dense fusion conditions. In comparison with the unmagnetized case, self-generated Biermann fields make only a minor difference to growth rates. However, simulations with a large 50 kT external field found that the growth rate of the least stable mode increased by 40%. In conclusion, this has implications for mix processes in Z-pinches and magnetized inertial confinement fusion concepts.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single Crystal Diamond Beam Position Monitors with Radiofrequency Electronic Readout

Over the energy range 5{approx}30 keV a suitably contacted, thin ({approx}100 {mu}m) diamond plate can be operated in situ as a continuous monitor of X-ray beam intensity and position as the diamond absorbs only a small percentage of the incident beam. Single crystal diamond is a completely homogeneous material showing fast (ns), spatially uniform signal response and negligible (<pA) leakage currents. Due to its unsurpassed thermal conductivity, it is the only semiconductor material that can be used in intense synchrotron white beams. We report on tests made at ESRF and DESY using diamond beam position monitors of simple quadrant electrode designs with metal contacts, operated using wideband electronic readout corresponding to the RF accelerator frequency. The instrumentation for these monitors must cover a large range of operating conditions: different beam sizes, fluxes, energies and time structure corresponding to the synchrotron fill patterns. Sophisticated new RF sampling electronics can satisfy most requirements: using a modified Libera Brilliance readout system, we measured the center of gravity position of a 25 {mu}m beam at the DORIS III F4 beam line at a rate of 130 Msample/s with narrowband filtering of a few MHz bandwidth. Digitally averaging the signal further provided a spatial resolution {approx}20 nm.

43 PARTICLE ACCELERATORS↗

Enabling Long-Duration Lunar Equatorial Operations With Thermal Wadi Infrastructure

Long duration missions on the Moon s equator must survive lunar nights. With 350 hr of cryogenic temperatures, lunar nights present a challenge to robotic survival. Insulation is imperfect, so it is not possible to passively contain enough heat to stay warm through the night. Components that enable mobility, environmental sensing and solar power generation must be exposed, and they leak heat. Small, lightweight rovers cannot store enough energy to warm components throughout the night without some external source of heat or power. Thermal wadis, however, can act as external heat sources to keep robots warm through the lunar night. Electrical power can also be provided to rovers during the night from batteries stored in the ground beside wadis. Buried batteries can be warmed by the wadi s heat. Results from analysis of the interaction between a rover and a wadi are presented. A detailed three-dimensional (3D) thermal model and an easily configurable two-dimensional (2D) thermal model are used for analysis.

Jones, Heather L.↗

Method of Promoting Single Crystal Growth During Melt Growth of Semiconductors

The method of the invention promotes single crystal growth during fabrication of melt growth semiconductors. A growth ampoule and its tip have a semiconductor source material placed therein. The growth ampoule is placed in a first thermal environment that raises the temperature of the semiconductor source material to its liquidus temperature. The growth ampoule is then transitioned to a second thermal environment that causes the semiconductor source material in the growth ampoule's tip to attain a temperature that is below the semiconductor source material's solidus temperature. The growth ampoule so-transitioned is then mechanically perturbed to induce single crystal growth at the growth ampoule's tip.

Su, Ching-Hua↗

Geometrical quasi-ballistic effects on thermal transport in nanostructured devices

In this work, we employ thermoreflectance thermal imaging to directly measure the steady-state two-dimensional (2D) temperature field generated by nanostructured heat sources deposited on silicon substrate with different geometrical configurations and characteristic sizes down to 400nm. The analysis of the results using Fourier’s law not only breaks down as size scales down, but it also fails to capture the impact of the geometry of the heat source. The substrate effective Fourier thermal conductivities fitted to wire-shaped and circular-shaped structures with identical characteristic lengths are found to display up to 40% mismatch. Remarkably, a hydrodynamic heat transport model reproduces the observed temperature fields for all device sizes and shapes using just intrinsic Si parameters, i.e., a geometry and size-independent thermal conductivity and nonlocal length scale. The hydrodynamic model provides insight into the observed thermal response and of the contradictory Fourier predictions. We discuss the substantial Silicon hydrodynamic behavior at room temperature and contrast it to InGaAs, which shows less hydrodynamic effects due to dominant phonon-impurity scattering.

42 ENGINEERING↗

Development of an All-Aqueous Thermally Regenerative Redox Flow Battery to Support Fossil Fuel Assets

Low-temperature thermal energy, a largely untapped resource, holds significant promise for large-scale electrical power generation globally. Various stationary sources, including industrial entities and thermal power plants, emit considerable low-temperature heat that currently remains unutilized. This energy is often overlooked because its low temperature renders it unsuitable for efficient power generation using conventional methods. However, current research is exploring diverse technologies capable of converting low-temperature heat into grid-scale power, aiming to enhance grid efficiency, further decarbonization initiatives, and facilitate a shift toward more decentralized power systems. One such innovative technology is the thermally regenerative battery (TRB), noted for its high power and energy densities compared to similar technologies, positioning it as a potential game-changer in power generation. TRBs integrate two scalable and well-established unit operations: a redox flow battery and a distillation column. This integration suggests that once an effective TRB chemistry is established, the pathway to commercialization could be expedited. The copper-based thermally regenerative ammonia battery (Cu aq -TRAB) stands out as the first TRB that circumvents electrodeposition/dissolution reactions, stabilizing Cu(I) and Cu(II) within the electrolyte and maintaining stability of all electroactive species in an aqueous phase. This stabilization has led to improvements in coulombic efficiency, open circuit potential, and copper solubility, thereby enhancing power density, energy density, and overall energy efficiency. Preliminary tests were conducted to determine the effects of various electrolyte species on the performance metrics of the battery, both theoretically and experimentally. These tests revealed that the solubility of copper in the Cu aq -TRAB electrolyte was constrained by the Cu(I)-NH 3 complex. Adjusting the background electrolyte to 5 M NH4Br and the ligand concentration to 4 M NH 3 enabled the copper concentration to reach a maximum of 0.6 M. This modification led to an estimated theoretical maximum energy density of 9.5 Wh L -1 for the Cu aq -TRAB. Additionally, full cell testing indicated a tradeoff between peak power and energy density with varying copper and ammonia concentrations. Increasing the applied current density during discharge linearly raised the average power output, with a minimal reduction in energy density due to a balance between higher ohmic overpotential and reduced time for undesirable ammonia crossover. Furthermore, a comprehensive numerical sensitivity analysis of the complete Cu aq -TRAB system was performed. This analysis aimed to assess how the battery and the distillation column responded to changes in system input parameters, providing insights into optimal research directions for enhancing system performance. The analysis revealed that at room temperature, battery power was significantly more sensitive to ohmic losses than to mass transfer, with reaction rates having minimal impact. This trend continued even at higher temperatures. Also, the thermal energy required for ammonia separation was studied, showing that increased temperatures generally reduced energy requirements, except in low-pressure scenarios above 65 °C. An investigation into membrane performance in the Cu aq -TRAB was undertaken, given the significant impact of ammonia transport control and ohmic losses on system performance. Various membranes were evaluated to identify key performance metrics. Among the tested membranes, Selemion CMVN exhibited the highest performance, with a peak power density of 84 mW cm -2 and average values of 26 ± 6.8 mW cm -2 for power density and 2.9 Wh L -1 for energy density at an applied current density of 50 mA cm -2 . An economic assessment indicated a levelized cost of storage at $410 per MWh under optimal conditions, highlighting the commercial potential of the Cu aq -TRAB when utilizing cost-effective, readily available materials.

25 ENERGY STORAGE↗

Empirical Study of the Effect of Thermal Loading on the Heating Efficiency of Variable-Speed Air Source Heat Pumps

Heating buildings with air source heat pumps (ASHPs) has the potential to save energy compared to utilizing conventional heat sources. Accurate understanding of the efficiency of ASHPs is important to maximize the energy savings. While it is well understood that, in general, ASHP efficiency decreases with decreasing outdoor temperature, it is not well understood how the ASHP efficiency changes with different levels of thermal loading, even though it is an important consideration for sizing and controlling ASHPs. The goal of this study was to create an empirical model of the ASHP efficiency as a function of two independent variables–outside temperature and level of thermal loading. Four ductless mini-split ASHPs were evaluated in a cold chamber where the temperature (representing the outdoor temperature) was varied over a wide range. For each temperature, the ASHP performance data were collected at several levels of thermal loading. The data for all four ASHPs were combined and approximated with an analytical function that can be used as a general model for the ASHP steady-state efficiency as a function of the outside temperature and level of thermal loading. To the knowledge of the authors, no such empirical model that is solely based on third-party test data has been published before. While limitations exist, the model can be used to help guide future selection and operation of ASHPs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Overview of Liquid Fluoride Salt Heat Transport Systems

Heat transport is central to all thermal-based forms of electricity generation. The ever increasing demand for higher thermal efficiency necessitates power generation cycles transitioning to progressively higher temperatures. Similarly, the desire to provide direct thermal coupling between heat sources and higher temperature chemical processes provides the underlying incentive to move toward higher temperature heat transfer loops. As the system temperature rises, the available materials and technology choices become progressively more limited. Superficially, fluoride salts at {approx}700 C resemble water at room temperature being optically transparent and having similar heat capacity, roughly three times the viscosity, and about twice the density. Fluoride salts are a leading candidate heat-transport material at high temperatures. Fluoride salts have been extensively used in specialized industrial processes for decades, yet they have not entered widespread deployment for general heat transport purposes. This report does not provide an exhaustive screening of potential heat transfer media and other high temperature liquids such as alkali metal carbonate eutectics or chloride salts may have economic or technological advantages. A particular advantage of fluoride salts is that the technology for their use is relatively mature as they were extensively studied during the 1940s-1970s as part of the U.S. Atomic Energy Commission's program to develop molten salt reactors (MSRs). However, the instrumentation, components, and practices for use of fluoride salts are not yet developed sufficiently for commercial implementation. This report provides an overview of the current understanding of the technologies involved in liquid salt heat transport (LSHT) along with providing references to the more detailed primary information resources. Much of the information presented here derives from the earlier MSR program. However, technology has evolved over the intervening years, and this report also describes more recently developed technologies such as dry gas seals. This report also provides a high-level, parametric evaluation of LSHT loop performance to allow general intercomparisons between heat-transport fluid options as well as provide an overview of the properties and requirements for a representative loop. A compilation of relevant thermophysical properties of useful fluoride salts is also included for salt heat transport systems. Fluoride salts can be highly corrosive depending on the container materials selected, the salt chemistry, and the operating procedures used. The report includes an overview of the state-of-the-art in reduction-oxidation chemistry control methodologies employed to minimize corrosion issues. Salt chemistry control technology, however, remains at too low a level of understanding for widespread industrial usage. Loop operational issues such as start-up procedures and system freeze-up vulnerability are also discussed. Liquid fluoride salts are a leading candidate heat transport medium for high-temperature applications. This report provides an overview of the current status of liquid salt heat transport technology. The report includes a high-level, parametric evaluation of liquid fluoride salt heat transport loop performance to allow intercomparisons between heat-transport fluid options as well as providing an overview of the properties and requirements for a representative loop. Much of the information presented here derives from the earlier molten salt reactor program and a significant advantage of fluoride salts, as high temperature heat transport media is their consequent relative technological maturity. The report also includes a compilation of relevant thermophysical properties of useful heat transport fluoride salts. Fluoride salts are both thermally stable and with proper chemistry control can be relatively chemically inert. Fluoride salts can, however, be highly corrosive depending on the container materials selected, the salt chemistry, and the operating procedures used. The report also provides an overview of the state-of-the-art in reduction-oxidation chemistry control methodologies employed to minimize salt corrosion as well as providing a general discussion of heat transfer loop operational issues such as start-up procedures and freeze-up vulnerability.

heat transfer↗

Formation and detection of high latitude ionospheric irregularities

Measurements of Total Electron Content (TEC) and airglow variations show that large scale plasma patches appearing in the high-latitude ionsophere have irregular structures evidenced by the satellite phase and amplitude scintillations. Whistler waves, intense quasi-DC electric field, and atmospheric gravity waves can become potential sources of various plamsa instabilities. The role of thermal effects in generating ionospheric irregularities by these sources is discussed. Meter-scale irregularities in the ionospheric E and F regions can be excited parametrically with lower hybrid waves by intense whistler waves. Ohmic dissipation of Pedersen current in the electron gas is able to create ionospheric F region irregularities in plasma blobs or plasma patches (i.e., high ambient plasma density environment) with broad scale lengths ranging from tens of meters to a few kilometers. Through the neutral-charged particle collisions, gravity waves can excite large-scale (less than tens of kilometers) ionospheric irregularities simultaneously with forced ion acoustic modes in the E region. The large-scale ionospheric density fluctuations produced in the E region can extend subsequently alogn the earth's magnetic field to the F region and the topside ionospheric regions. These mechanisms characterized by various thermal effects can contribute additively with other processes to the formation of ionospheric irregularities in the high latitude region.

Lee, M. C.↗

Multiwavelength Observations of the Blazar VER J0521+211 during an Elevated TeV Gamma-Ray State

We report on a long-lasting, elevated gamma-ray flux state from VER J0521+211 observed by VERITAS, MAGIC, and Fermi-LAT in 2013 and 2014. The peak integral flux above 200 GeV measured with the nightly binned light curve is (8.8 ± 0.4) × 10 –7 photons m –2 s –1 , or ~37% of the Crab Nebula flux. Multiwavelength observations from X-ray, UV, and optical instruments are also presented. A moderate correlation between the X-ray and TeV gamma-ray fluxes was observed, and the X-ray spectrum appeared harder when the flux was higher. Using the gamma-ray spectrum and four models of the extragalactic background light (EBL), a conservative 95% confidence upper limit on the redshift of the source was found to be z ≤ 0.31. Unlike the gamma-ray and X-ray bands, the optical flux did not increase significantly during the studied period compared to the archival low-state flux. The spectral variability from optical to X-ray bands suggests that the synchrotron peak of the spectral energy distribution (SED) may become broader during flaring states, which can be adequately described with a one-zone synchrotron self-Compton model varying the high-energy end of the underlying particle spectrum. The synchrotron peak frequency of the SED and the radio morphology of the jet from the MOJAVE program are consistent with the source being an intermediate-frequency-peaked BL Lac object.

79 ASTRONOMY AND ASTROPHYSICS↗

Is chemical heating a major cause of the mesosphere inversion layer?

A region of thermal enhancement of the mesosphere has been detected on numerous occasions by in situ measurements, remote sensing from space, and lidar techniques. The source of these 'temperature inversion layers' has been attributed in the literature to the dissipation relating to dynamical forcing by gravity wave or tidal activity. However, evidence that gravity wave breaking can produce the inversion layer with amplitude as large as that observed in lidar measurements has been limited to results of numerical modeling. An alternative source for the production of the thermal inversion layer in the mesosphere is the direct deposition of heat by exothermic chemical reactions. Two-dimensional modeling combining a comprehensive model of the mesosphere photochemistry with the dynamical transport of long-lived species shows that the region from 80 to 95 km may be heated as much as 3 to 10 K/d during the night and half this rate during the day. Given the uncertainties in our understanding of the dynamics and chemistry for the mesopause region, separating the two sources by passive observations of the mesosphere thermal structure looks to be difficult. Therefore we have considered an active means for producing a mesopause thermal layer, namely the release of ozone into the upper mesosphere from a rocket payload. The induced effects would include artificial enhancements of the OH and Na airglow intensities as well as the mesopause thermal structure. The advantages of the rocket release of ozone is that detection of these effects by ground-based imaging, radar, and lidar systems and comparison of these effects with model predictions would help quantify the partition of the artificial inversion layer production into sources of dynamical and chemical forcing.

Meriwether, John W.↗

Study of thermal and acoustic noise interferences in low stiffness atomic force microscope cantilevers and characterization of their dynamic properties

The atomic force microscope (AFM) is a powerful tool for the measurement of forces at the micro/nano scale when calibrated cantilevers are used. Besides many existing calibration techniques, the thermal calibration is one of the simplest and fastest methods for the dynamic characterization of an AFM cantilever. This method is efficient provided that the Brownian motion (thermal noise) is the most important source of excitation during the calibration process. Otherwise, the value of spring constant is underestimated. This paper investigates noise interference ranges in low stiffness AFM cantilevers taking into account thermal fluctuations and acoustic pressures as two main sources of noise. As a result, a preliminary knowledge about the conditions in which thermal fluctuations and acoustic pressures have closely the same effect on the AFM cantilever (noise interference) is provided with both theoretical and experimental arguments. Consequently, beyond the noise interference range, commercial low stiffness AFM cantilevers are calibrated in two ways: using the thermal noise (in a wide temperature range) and acoustic pressures generated by a loudspeaker. We then demonstrate that acoustic noises can also be used for an efficient characterization and calibration of low stiffness AFM cantilevers. The accuracy of the acoustic characterization is evaluated by comparison with results from the thermal calibration.

36 MATERIALS SCIENCE↗

Dielectron production at midrapidity at low transverse momentum in peripheral and semi-peripheral Pb–Pb collisions at ${\sqrt{s}}_{\textrm{NN}}$ = 5.02 TeV

The first measurement of the e + e – pair production at low lepton pair transverse momentum (p T,ee ) and low invariant mass (m ee ) in non-central Pb–Pb collisions at ${\sqrt{s}}_{\textrm{NN}}$ = 5.02 TeV at the LHC is presented. The dielectron production is studied with the ALICE detector at midrapidity (|η e | < 0.8) as a function of invariant mass (0.4 ≤ m ee < 2.7 GeV/c 2 ) in the 50–70% and 70–90% centrality classes for p T,ee < 0.1 GeV/c, and as a function of p T,ee in three m ee intervals in the most peripheral Pb–Pb collisions. Below a p T,ee of 0.1 GeV/c, a clear excess of e + e – pairs is found compared to the expectations from known hadronic sources and predictions of thermal radiation from the medium. The m ee excess spectra are reproduced, within uncertainties, by different predictions of the photon–photon production of dielectrons, where the photons originate from the extremely strong electromagnetic fields generated by the highly Lorentz-contracted Pb nuclei. Lowest-order quantum electrodynamic (QED) calculations, as well as a model that takes into account the impact-parameter dependence of the average transverse momentum of the photons, also provide a good description of the p T,ee spectra. The measured $\sqrt{\left\langle {p}_{\textrm{T},\textrm{ee}}^2\right\rangle }$ of the excess p T,ee spectrum in peripheral Pb–Pb collisions is found to be comparable to the values observed previously at RHIC in a similar phase-space region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of satellite Leaf Area Index in California vineyards for improving water use estimation

Remote sensing estimation of evapotranspiration (ET) directly quantifies plant water consumption and provides essential information for irrigation scheduling, which is a pressing need for California vineyards as extreme droughts become more frequent. Many ET models take satellite-derived Leaf Area Index (LAI) as a major input, but how uncertainties of LAI estimations propagate to ET and the partitioning between evaporation and transpiration is poorly understood. Here we assessed six satellite-based LAI estimation approaches using Landsat and Sentinel-2 images against ground measurements from four vineyards in California and evaluated ET sensitivity to LAI in the thermal-based two-source energy balance (TSEB) model. We found that radiative transfer modeling-based approaches predicted low to medium LAI well, but they significantly underestimated high LAI in highly clumped vine canopies (RMSE ~ 0.97 to 1.27). Cubist regression models trained with ground LAI measurements from all vineyards achieved high accuracy (RMSE ~ 0.3 to 0.48), but these empirical models did not generalize well between sites. Red edge bands and the related vegetation index (VI) from the Sentinel-2 satellite contain complementary information of LAI to VIs based on near-infrared and red bands. TSEB ET was more sensitive to positive LAI biases than negative ones. Positive LAI errors of 50% resulted in up to 50% changes in ET, while negative biases of 50% in LAI caused less than 10% deviations in ET. However, even when ET changes were minimal, negative LAI errors of 50% led to up to a 40% reduction in modeled transpiration, as soil evaporation and plant transpiration responded to LAI change divergently. These findings call for careful consideration of satellite LAI uncertainties for ET modeling, especially for the partitioning of water loss between vine and soil or cover crop for effective vineyard irrigation management.

54 ENVIRONMENTAL SCIENCES↗

Two-Dimensional Problem of Thermoelasticity for a Half Space in the Presence of Heat Release in a Ribbon-Shaped Domain Parallel to its Boundary

Using a logarithmic single-layer potential, thermoelastic displacement potential, Airy stress function, and Boussinesq function, we solve two-dimensional problems of stationary heat conduction and thermoelasticity under the conditions of plane deformation of a semiinfinite body in the presence of heat release in a ribbon-shaped domain parallel to its boundary (in this domain, either a temperature or a heat flux is given). The boundary of the body is kept at temperature equal to zero. We study the distribution of stresses in the domain of heat release with given heat sources of constant intensity at constant temperature.

42 ENGINEERING↗

Modeling Energy Recovery Using Thermoelectric Conversion Integrated with an Organic Rankine Bottoming Cycle

Hot engine exhaust represents a resource that is often rejected to the environment without further utilization. This resource is most prevalent in the transportation sector, but stationary engine-generator systems also typically do not utilize this resource. Engine exhaust is a source of high grade thermal energy that can potentially be utilized by various approaches to produce electricity or to drive heating and cooling systems. This paper describes a model system that employs thermoelectric conversion as a topping cycle integrated with an organic Rankine bottoming cycle for waste heat utilization. This approach is being developed to fully utilize the thermal energy contained in hot exhaust streams. The model is composed of a high temperature heat exchanger which extracts thermal energy for driving the thermoelectric conversion elements. However, substantial sensible heat remains in the exhaust stream after emerging from the heat exchanger. The model incorporates a closely integrated bottoming cycle to utilize this remaining thermal energy in the exhaust stream. The model has many interacting parameters that define combined system quantities such as overall output power, efficiency, and total energy utilization factors. In addition, the model identifies a maximum power operating point for the system. That is, the model can identify the optimal amount of heat to remove from the exhaust flow to run through the thermoelectric elements. Removing too much or too little heat from the exhaust stream in this stage will reduce overall cycle performance. The model has been developed such that heat exchanger UAh values, thermal resistances, ZT values, and multiple thermoelectric elements can be investigated in the context of system operation. The model also has the ability to simultaneously determine the effect of each cycle design parameter on the performance of the overall system, thus giving the ability to utilize as much waste heat as possible. Key analysis results are presented showing the impact of critical design parameters on power output, system performance and inter-relationships between design parameters in governing performance.

30 DIRECT ENERGY CONVERSION↗

Energy impact of heating electrification in mid-rise multifamily buildings in mixed-humid climates

Decarbonizing the electric grid in conjunction with electrifying residential heating is a critical step to combat climate change. Heating in multifamily buildings with the existing natural gas-fired central boiler is a complex process that not only leads to overheating in some apartment units but also results in energy waste and high gas bills. In this study, we consider a multifamily building in New York City, USA, to evaluate the performance of five different heating systems, which represent a step-by-step transition from the conventional to a fully electrified heating system, and determine their impact on the site energy consumption and source CO 2 emissions. Results indicate that overheating in a multifamily building can raise the indoor temperature by as much as 8°C above comfortable limits. Transitioning from conventional steam radiators to cold climate heat pumps can reduce annual site heating energy by up to 70% and source CO 2 emissions by up to 21%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗