Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Ultra-Low Noise Germanium Neutrino Detection system (ULGeN).

Monitoring nuclear power plant operation by measuring the antineutrino flux has become an active research field for safeguards and non-proliferation. We describe various efforts to demonstrate the feasibility of reactor monitoring based on the detection of the Coherent Neutrino Nucleus Scattering (CNNS) process with High Purity Germanium (HPGe) technology. CNNS detection for reactor antineutrino energies requires lowering the electronic noise in low-capacitance kg-scale HPGe detectors below 100 eV as well as stringent reduction in other particle backgrounds. Existing state- of-the-art detectors are limited to an electronic noise of 95 eV-FWHM. In this work, we employed an ultra-low capacitance point-contact detector with a commercial integrated circuit preamplifier- on-a-chip in an ultra-low vibration mechanically cooled cryostat to achieve an electronic noise of 39 eV-FWHM at 43 K. We also present the results of a background measurement campaign at the Spallation Neutron Source to select the area with sufficient low background to allow a successful first-time measurement of the CNNS process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial Temperature Testing of Advanced Manufactured Melt Wire Package

As a part of the In-Pile Instrumentation Program, The Idaho National Laboratory (INL) has recently established in-house capabilities to fabricate and test new advanced manufactured sensors for measuring the peak irradiation temperature inside a nuclear test reactor. Although nuclear test reactors can use standard methods of real-time temperature monitoring, such as thermocouples, the complexity of feedthroughs and attachment complications to collect real-time measurements greatly increases the cost of the experiment. Passive monitoring techniques may be utilized that exploit the melting point of well characterized material (standard melt wires), however, the limited space available for instrumentation during experiments is also a challenge. To accommodate the challenge, INL has expanded its temperature detection instrumentation capabilities paired with the advancement of in-house advanced manufacturing options to include printed melt wires for peak irradiation temperature measurement. The advanced manufactured melt wire package can determine peak temperatures in experiments that can fit the challenging space available during irradiation. Recent results and knowledge from this ongoing work have made it possible to develop unique temperature sensors that can accomplish user specific temperature ranges inside the harsh environments experienced during radiation testing. This report summarizes the initial temperature testing using fabricated melt wires with two different melting temperatures, silver (melting temperature of ~960 °C) and solder (melting temperature of ~160 °C), that were initially tested for their relative melting points using non-standard method of furnace and hot plate testing under normal air conditions. Future work will include more controlled way of testing printed melt wires under inert gas with multiple temperature measurements followed by comparison of standard melt wire package performance for baseline characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Further ROSAT measurements of the period of 4U 1820-30

We have made two new observations of 4U 1820-30 with the ROSAT position sensitive proportional counter (PSPC). The measurements do not provide further evidence for a secular period decrease of this source. Instead, after inclusion of our new arrival time measurements the significance of the orbital period derivative drops (from 5.5 to 4.6 sigma), its best-fit value decreases (to P-dot/P =(-5.3 +/- 1.1) x 10(exp -8)/yr) and the formal probability that statistical fluctuations have caused the observed P-dot increases to 0.5% (from 0.003%). We detect light curve changes that are large enough to be the cause of some (or all) of the period changes seen in 4U 1820-30, but not large enough to explain the discrepancy of the observed period derivative with that theoretically predicted. We explore the possibility that the secular period change observed during 1976-1991 could have been dominated by random or systematic changes in the position and shape of an occulting bulge on the disk rim and conclude that phase shifts caused by this mechanism could in principle explain the discrepancy entirely.

Klis, M. Van Der↗

A Robot for Nondestructive Assay of Holdup Deposits in Gaseous Diffusion Piping - 19504

Miles of contaminated pipe must be characterized as part of the decommissioning effort at deactivated gaseous diffusion enrichment facilities. The current method requires cutting away asbestos- lined thermal enclosures and performing repeated, elevated operations to manually perform nondestructive assay (NDA) on pipe from the outside. The RadPiper robot, part of the Pipe Crawling Activity Measurement System (PCAMS) developed by Carnegie Mellon University and commissioned for use at the DOE Portsmouth Gaseous Diffusion Enrichment Facility, automatically measures U-235 in pipes from the inside. This improves certainty, increases safety, and greatly reduces measurement time. The heart of the RadPiper robot is a sodium iodide scintillation detector in an innovative disc-collimated assembly. By measuring from inside pipes, the robot significantly increases its count rate relative to external through-pipe measurements. The robot also provides imagery, models interior pipe geometry, and precisely measures distance in order to localize radiation measurements. Data collected by this system provides insight into pipe interiors that is simply not possible from exterior measurements, all while keeping operators safer. This paper describes the technical details of the PCAMS RadPiper robot. Key features for this robot include precision distance measurement, in-pipe obstacle detection, ability to transform for two pipe sizes, and robustness in autonomous operation. Test results demonstrating the robot's functionality are presented, including deployment tolerance tests, safeguarding tests, and localization tests. Integrated robot tests are also shown. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measurement of time-dependent CP asymmetry in B{sup 0}{yields}ccK{sup (*)0} decays

We present updated measurements of time-dependent CP asymmetries in fully reconstructed neutral B decays containing a charmonium meson. The measurements reported here use a data sample of (465{+-}5)x10{sup 6} {upsilon}(4S){yields}BB decays collected with the BABAR detector at the PEP-II asymmetric energy e{sup +}e{sup -} storage rings operating at the SLAC National Accelerator Laboratory. The time-dependent CP asymmetry parameters measured from J{psi}K{sub S}{sup 0}, J{psi}K{sub L}{sup 0}, {psi}(2S)K{sub S}{sup 0}, {eta}{sub c}K{sub S}{sup 0}, {chi}{sub c1}K{sub S}{sup 0}, and J/{psi}K*(892){sup 0} decays are: C{sub f}=0.024{+-}0.020(stat){+-}0.016(syst) and -{eta}{sub f}S{sub f}=0.687{+-}0.028(stat){+-}0.012(syst)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The mass of the central black hole in the nearby Seyfert galaxy NGC 5273

We present the results of a reverberation-mapping program targeting NGC 5273, a nearby early-type galaxy with a broad-lined active galactic nucleus (AGN). Over the course of the monitoring program, NGC 5273 showed strong variability that allowed us to measure time delays in the responses of the broad optical recombination lines to changes in the continuum flux. A weighted average of these measurements results in a black hole mass determination of M {sub BH} = (4.7 ± 1.6) × 10{sup 6} M {sub ☉}. An estimate of the size of the black hole sphere of influence in NGC 5273 puts it just at the limit of the resolution achievable with current ground-based large aperture telescopes. NGC 5273 is therefore an important future target for a black hole mass determination from stellar dynamical modeling, especially because it is the only nearby early-type galaxy hosting an AGN with a reverberation-based mass, allowing the best comparison for the masses determined from these two techniques.

79 ASTRONOMY AND ASTROPHYSICS↗

NEET Enhanced Micro Pocket Fission Detector for High Temperature Reactors - FY15 Status Report

A new project, that is a collaboration between the Idaho National Laboratory (INL), the Kansas State University (KSU), and the French Atomic Energy Agency, Commissariat à l'Énergie Atomique et aux Energies Alternatives, (CEA), has been initiated by the Nuclear Energy Enabling Technologies (NEET) Advanced Sensors and Instrumentation (ASI) program for developing and testing High Temperature Micro-Pocket Fission Detectors (HT MPFD), which are compact fission chambers capable of simultaneously measuring thermal neutron flux, fast neutron flux and temperature within a single package for temperatures up to 800 °C. The MPFD technology utilizes a small, multi-purpose, robust, in-core parallel plate fission chamber and thermocouple. As discussed within this report, the small size, variable sensitivity, and increased accuracy of the MPFD technology represent a revolutionary improvement over current methods used to support irradiations in US Material Test Reactors (MTRs). Previous research conducted through NEET ASI1-3 has shown that the MPFD technology could be made robust and was successfully tested in a reactor core. This new project will further the MPFD technology for higher temperature regimes and other reactor applications by developing a HT MPFD suitable for temperatures up to 800 °C. This report summarizes the research progress for year one of this three year project. Highlights from research accomplishments include: A joint collaboration was initiated between INL, KSU, and CEA. Note that CEA is participating at their own expense because of interest in this unique new sensor. An updated HT MPFD design was developed. New high temperature-compatible materials for HT MPFD construction were procured. Construction methods to support the new design were evaluated at INL. Laboratory evaluations of HT MPFD were initiated. Electrical contact and fissile material plating has been performed at KSU. Updated detector electronics are undergoing evaluations at KSU. A project meeting was held at KSU to discuss the roles and responsibilities between INL and KSU for development of the HT MPFDs. Provide input to various irradiation programs for installation of the MPFD technology in irradiation tests. As documented in this report, FY15 funding has allowed the project to meet year one planned accomplishments to develop a HT MPFD that offers US MTR users enhanced capabilities for real-time measurement of flux and temperature with a single detector. In addition, the accomplishments of this project have attracted funding from other Department of Energy Office of Nuclear Energy (DOE-NE) programs for additional applications. The work in those programs will build on current activities completed in this NEETASI HT MPFD project, but the MPFD will be specifically tailored to meet their program needs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Portable x-ray fluorescence spectrometer for coating thickness measurement

A handheld x-ray spectrometer has been realized and tested. The purpose of the device is to measure the thickness of coated samples in the range of 1-1500 nm in an industrial environment. Accuracy of {approx}3% has been achieved in this range with a measurement time of 1 min. Automated software has been implemented to allow utilization by a nonspecialist operator. An automated calibration procedure, based on measurements of reference samples, is used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Water-anion hydrogen bonding dynamics: Ultrafast IR experiments and simulations

Many of water’s remarkable properties arise from its tendency to form an intricate and robust hydrogen bond network. Understanding the dynamics that govern this network is fundamental to elucidating the behavior of pure water and water in biological and physical systems. In ultrafast nonlinear infrared experiments, the accessible time scales are limited by water’s rapid vibrational relaxation (1.8 ps for dilute HOD in H 2 O), precluding interrogation of slow hydrogen bond evolution in non-bulk systems. Here in this paper, hydrogen bonding dynamics in bulk D 2 O were studied from the perspective of the much longer lived (36.2 ps) CN stretch mode of selenocyanate (SeCN-) using polarization selective pump-probe (PSPP) experiments, two-dimensional infrared (2D IR) vibrational echo spectroscopy, and molecular dynamics simulations. The simulations make use of the empirical frequency mapping approach, applied to SeCN - for the first time. The PSPP experiments and simulations show that the orientational correlation function decays via fast (2.0 ps) restricted angular diffusion (wobbling-in-a-cone) and complete orientational diffusive randomization (4.5 ps). Spectral diffusion, quantified in terms of the frequency-frequency correlation function, occurs on two time scales. The initial 0.6 ps time scale is attributed to small length and angle fluctuations of the hydrogen bonds between water and SeCN - . The second 1.4 ps measured time scale, identical to that for HOD in bulk D 2 O, reports on the collective reorganization of the water hydrogen bond network around the anion. Lastly, the experiments and simulations provide details of the anion-water hydrogen bonding and demonstrate that SeCN- is a reliable vibrational probe of the ultrafast spectroscopy of water.

14 SOLAR ENERGY↗

Analytical Improvements in PV Degradation Rate Determination

As photovoltaic (PV) penetration of the power grid increases, it becomes vital to know how decreased power output may affect cost over time. In order to predict power delivery, the decline or degradation rates must be determined accurately. For non-spectrally corrected data several complete seasonal cycles (typically 3-5 years) are required to obtain reasonably accurate degradation rates. In a rapidly evolving industry such a time span is often unacceptable and the need exists to determine degradation rates accurately in a shorter period of time. Occurrence of outliers and data shifts are two examples of analytical problems leading to greater uncertainty and therefore to longer observation times. In this paper we compare three methodologies of data analysis for robustness in the presence of outliers, data shifts and shorter measurement time periods.

14 SOLAR ENERGY↗

Reliability Value of Fast State Estimation on Power Systems

Monitoring the state of a power system under stress is key to achieving reliable operation. State estimation and timely measurements become more important when applying and designing corrective control actions (manual and automatic) to arrest or mitigate cascading blackouts. The execution time of each process, including state estimation, should be as short as possible to allow for timely action. In this paper, we provide a methodology for estimating one of the components of value of faster and more frequent state estimation: the reliability value of state estimation to assist corrective control actions for arresting or mitigating cascading blackouts. We present a new algorithm for estimating the time between successive line trips in a cascading failure. The algorithm combines power flow calculations with characteristics of the protection system to estimate the time between successive equipment trips. Using this algorithm, we illustrate the value of fast state estimation by calculating the time remaining for automatic or manual corrective actions after state estimation is finalized.

Power system state estimation, cascading failures,↗

Acousto-optic Extensometer for Bolts

Bolt torque or tension deduced from non contacting measurements. Pulsed Laser induces shockwave in bolthead while continuous-wave acousto-optic detector monitors distortion produced by shock. Shock travel time measured to determine bolt length. Solid-state position detector relatively inexpensive and keeps down cost of extensometer.

Maram, J.↗

Modeling and optimum time performance for concurrent processing

The development of a new graph theoretic model for describing the relation between a decomposed algorithm and its execution in a data flow environment is presented. Called ATAMM, the model consists of a set of Petri net marked graphs useful for representing decision-free algorithms having large-grained, computationally complex primitive operations. Performance time measures which determine computing speed and throughput capacity are defined, and the ATAMM model is used to develop lower bounds for these times. A concurrent processing operating strategy for achieving optimum time performance is presented and illustrated by example.

Mielke, Roland R.↗

Three-body effects in the PSR 1257+12 planetary system

A detailed theoretical analysis of the three-body effects in the putative planetary system of PSR 1257+12 is presented. Ways in which these effects are manifested in the pattern of pulse arrival times are discussed; the dominant perturbation is described as a modulation of the phases of the near-sinusoidal signals of the two planetary companions. Explicit formulas for the time dependence of the oscillating orbital elements that are needed for an improved timing model for this system are provided. If a timing model with fixed, independent Keplerian orbits continues to be used for the timing analysis, and if two planets are indeed orbiting this pulsar, then the three-body effects should become detectable by means of a growth in the postfit residuals as more observations are accumulated. If the typical error in the pulse arrival time measurements is about 10 microsec, the amplitude of the postfit residuals will increase beyond this level with three to five years of timing observations.

Malhotra, Renu↗

Measuring Massive Black Hole Binaries with LISA

The coalescence of two massive black holes produces gravitational waves (GWs) which can be detected by the space-based detector LISA. By measuring these waves, LISA can determine the various parameters which characterize the source. Measurements of the black hole masses and spins will provide information about the growth of black holes and their host galaxies over time. Measurements of a source's sky position and distance may help astronomers identify an electromagnetic counterpart to the GW event. The counterpart's redshift, combined with the GW-measured luminosity distance, can then be used to measure the Hubble constant and the dark energy parameter $w$. Because the potential science output is so high, it is useful to know in advance how well LISA can measure source parameters for a wide range of binaries. We calculate expected parameter estimation errors using the well-known Fisher matrix method. Our waveform model includes the physics of spin precession, as well as subleading harmonics. When these higher-order effects are not included, strong degeneracies between some parameters cause them to be poorly determined by a GW measurement. When precession and subleading harmonics are properly included, the degeneracies are broken, reducing parameter errors by one to several orders of magnitude.

Lang, Ryan N.↗

A Method for Correlating Forward-Looking Remote Sensor Measurements with In-Situ Measurements on Flying Platforms

A method is described for correlating measurements from a forward looking remote sensor with measurements made by in-situ instruments installed on the same flying platform. This method assumes that remote measurements are made within a volume of space in advance of the aircraft and that in-situ measurements provide representative values for discrete segments along the flight path. This correlation method can be applied to multiple sensors and makes no assumptions about the type of remote sensor or in-situ instrument, nor what either measures. It may be applied to recorded data during post-flight analysis based on known 4-D location (geospacial position and time) measurements.

Justin K. Strickland↗

High resolution selective multilayer laser processing by nanosecond laser ablation of metal nanoparticle films

Ablation of gold nanoparticle films on polymer was explored using a nanosecond pulsed laser, with the goal to achieve feature size reduction and functionality not amenable with inkjet printing. The ablation threshold fluence for the unsintered nanoparticle deposit was at least ten times lower than the reported threshold for the bulk film. This could be explained by the combined effects of melting temperature depression, lower conductive heat transfer loss, strong absorption of the incident laser beam, and the relatively weak bonding between nanoparticles. The ablation physics were verified by the nanoparticle sintering characterization, ablation threshold measurement, time resolved ablation plume shadowgraphs, analysis of ablation ejecta, and the measurement and calculation of optical properties. High resolution and clean feature fabrication with small energy and selective multilayer processing are demonstrated.

36 MATERIALS SCIENCE↗

Explosion bomb measurements of ethanol-air laminar gaseous flame characteristics at pressures up to 1.4 MPa

The principal burning characteristics of a laminar flame comprise the fuel vapour pressure, the laminar burning velocity, ignition delay times, Markstein numbers for strain rate and curvature, the stretch rates for the onset of flame instabilities and of flame extinction for different mixtures. With the exception of ignition delay times, measurements of these are reported and discussed for ethanol-air mixtures. The measurements were in a spherical explosion bomb, with central ignition, in the regime of a developed stable, flame between that of an under or over-driven ignition and that of an unstable flame. Pressures ranged from 0.1 to 1.4 MPa, temperatures from 300 to 393 K, and equivalence ratios were between 0.7 and 1.5. It was important to ensure the relatively large volume of ethanol in rich mixtures at high pressures was fully evaporated. The maximum pressure for the measurements was the highest compatible with the maximum safe working pressure of the bomb. Many of the flames soon became unstable, due to Darrieus-Landau and thermo-diffusive instabilities. This effect increased with pressure and the flame wrinkling arising from the instabilities enhanced the flame speed. Both the critical Peclet number and the, more rational, associated critical Karlovitz stretch factor were evaluated at the onset of the instability. With increasing pressure, the onset of flame instability occurred earlier. The measured values of burning velocity are expressed in terms of their variations with temperature and pressure, and these are compared with those obtained by other researchers. Some comparisons are made with the corresponding properties for iso-octane-air mixtures. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗