Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Steady state”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

A redox model for NO oxidation, NH 3 oxidation and high temperature standard SCR over Cu-SSZ-13

A kinetic model is developed to predict the influence of temperature and hydrothermal aging on the redox of active Cu sites under standard SCR, NO oxidation and NH 3 oxidation conditions over a practically relevant fully-formulated Cu-SSZ-13 catalyst. NO 2 /N 2 production during NO/NH 3 titration of Cu II sites is utilized to identify rate parameters associated with NO-only RHC (reduction half cycle) and NH 3 -only RHC respectively. Integral N 2 formation during subsequent NO + NH 3 titration is consistent with the production of one NO 2 per two CuII sites reduced during NO-only RHC and one N 2 per six Cu II sites reduced during NH 3 -only RHC. Decreased reduction of Cu II sites by NO/NH 3 upon hydrothermal aging, along with the production of one NO 2 per two CuII sites during NO-only RHC, is accordant with the involvement of proximal ZCuOH and oxygen-bridged dimeric Cu II sites. Oxidation of partially solvated and framework coordinated ZCu (Cu I ) sites occurs in presence of O 2 , does not produce N 2 and can lead to the consumption of Brønsted acid sites. A global OHC kinetic model is developed to predict transient and integral N 2 formation during exposure of CuI sites to a mixture of NO and O 2 . The resulting redox kinetic model quantitatively predicts NO and NH 3 consumption during isothermal transient response Cu redox (TRCR) protocols, along with temperature and age dependent steady-state standard SCR and oxidation conditions. The redox model presented in this work synthesizes recent kinetic, spectroscopic and computational findings to provide a foundational description of active site redox during standard SCR, NO oxidation and NH3 oxidation over Cu-SSZ-13.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of SO 2 poisoning and regeneration on spinel containing CH 4 oxidation catalysts

Methane oxidation under periodic conditions and the oxygen storage capacity of a bilayer Pt/Pd/Al 2 O 3 over a Mn 0.5 Fe 2.5 O 4 spinel catalyst were studied before and after SO 2 exposure, and after simulated regeneration conditions. Prior to sulfur exposure, improvement in CH 4 oxidation conversion under periodic conditions compared to steady-state conditions was observed. After sulfur exposure at 100 °C, there was a loss in CH 4 oxidation performance and a loss of oxygen storage capacity of the spinel material. Here, the extent of regeneration from sulfur poisoning depends on the ability to induce the decomposition of sulfate species, and while all regeneration methods tested in this study did improve CH 4 conversion, regeneration methods under periodic conditions induced greater sulfur species desorption from the catalyst surface leading to improved CH 4 con version. Key regeneration parameters – temperature, feed composition, modulation amplitude and frequency – were optimized to induce S species decomposition and correlated to CH 4 oxidation activity recovery.

03 NATURAL GAS↗

Understanding the Origin of Negative Temperature Dependence and Activity of N-Coordinated Cobalt Sites During Ethylene Dimerization

The on-demand production of short-chain linear alpha olefins (LAOs; C4-C8) via C2H4 dimerization and oligomerization is industrially attractive, prompting extensive research on designing active, selective, and stable catalysts for industrial use. Cobalt supported on ammoniated carbon (Co(NH3)x/C) catalysts have shown remarkable activity and selectivity in this process. However, critical aspects such as the active phase, active site structure, the role of the catalyst support, cobalt loading effects, and the inverse correlation of the reaction rate with temperature remain inadequately understood. This study systematically explores these factors using a combination of steady-state differential catalytic tests, in situ molecular characterization including diffuse reflectance UV-Vis (DR-UV-Vis), Infrared, and Raman spectroscopies, and ex situ X-ray diffraction (XRD) and high annular aberration-corrected dark field transmission electron microscopy (HAADF-STEM). Various supports (SiO2, Al2O3, NH4-ZSM-5, g-C3N4, and C) and cobalt loadings (1.0-3.0 Co nm-2) were studied to determine the optimal catalyst composition and identify the active phase and sites. Carbon-supported catalysts uniquely produce C4-8 LAOs during C2H4 dimerization, with site-time-yield remaining constant (~10-3 s-1) for 1.0-4.0 Co nm-2 at prolonged reaction times (24-48?h time-on-stream). At higher loadings of 6.0 Co nm-2, the formation of crystalline CoO and Co3O4 phases reduces catalytic activity and LAO selectivity. Our findings show that active catalysts lack crystalline cobalt oxides and instead feature dispersed Co2+ sites, tetra-coordinated to a mix of N/NH3 and O/H2O ligands, which catalyze C2H4 dimerization via the Cossee-Arlman mechanism, exhibiting 1st order dependence on C2H4 concentration. The observed inverse rate-temperature correlation is attributed to compensation effects (i.e., presence of Cremer-Constable relationship) linked to changes in adsorption enthalpic and entropic factors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental validation of an organic rankine-vapor compression cooling cycle using low GWP refrigerant R1234ze(E)

There is a significant global opportunity to capture and utilize low grade waste heat to reduce fossil fuel consumption, greenhouse gas emissions, and improve energy efficiency across a wide range of industries. In this work, an advanced type of thermally activated cooling system, an organic Rankine-vapor compression cycle (ORVC) with novel heat integration strategies, was designed and tested at a relevant scale for industrial waste heat recovery (300 kW th cooling capacity). The ORVC linked an organic Rankine power cycle and a vapor compression cooling cycle using a turbine and compressor that shared a single shaft. The ORVC test facility absorbed waste heat from a liquid stream at 91 °C to simulate engine coolant in diesel generator sets, rejected heat to a glycol stream at 30 °C, and generated chilled water at 7 °C. A cooling capacity of 264 kW ± 3.5 kW was experimentally validated with a COP of 0.56 ± 0.01 during steady-state operation at the design temperatures. The thermal efficiency, accounting for pump work, of the Rankine cycle was 7.7% ± 0.22% and the COP of the vapor compression cycle was 5.25 ± 0.09. The centrifugal turbo-compressor operated at 31.5 kRPM ± 0.3 kRPM, with a turbine and compressor isentropic efficiencies of 76.7% ± 0.90% and 84.8% ± 0.54%, respectively, with near-perfect power transmission between these components. The pressure drop in the piping and heat exchangers were significantly larger than expected which had a detrimental impact on the performance of the ORVC. In addition, the condenser on the cooling cycle could not deliver the subcooling as specified from the design point modeling. Furthermore, the results from the sensitivity analysis showed that the higher condenser glycol outlet temperature had the largest impact on performance, which is consistent with other analytical models in the literature. When the ORVC simulations were updated with experimental values for isentropic efficiencies of the turbomachinery, the thermal COP was 0.66 which represents an estimate of the predicted performance if test facility limitations are overcome.

30 DIRECT ENERGY CONVERSION↗

Thermo-economic analysis of a solid oxide fuel cell-gas turbine hybrid with commercial off-the-shelf gas turbine

The thermodynamic and economic performance of a natural gas-fueled solid oxide fuel cell (SOFC)-gas turbine (GT) hybrid system with a commercial off-the-shelf GT is investigated. Until today, commercial GTs are primarily engineered for the direct use of energy dense fuels, such as natural gas, and the integration of commercial GTs into a SOFC-GT hybrid remains challenging. In this work technically feasible and economically viable GT operating modes are identified to gauge the technology’s competitiveness on the free market. Steady state, full load operating conditions were established for various GT operating modes: I) constant spool speed operation, II) variable spool speed operation and III) partially closed compressor inlet guide vanes. For each GT operating mode, the performance was investigated over a range of SOFC fuel utilization factors, while considering physical constraints inside the SOFC, such as local temperature gradients in flow direction as well as overall cell temperature differences. The results of the thermodynamic evaluation served as inputs for the economic analysis of the SOFC-GT hybrid power plant. The results show that the integration of an off-the-shelf GT not only results in a significant derating of the GT, but also substantially impacts the SOFC operation, the main power producer in this SOFC-GT hybrid. To maximize the SOFC power output it is desirable operate the GT in a region of high air mass flow rates and low pressure ratios, which increases the number of stacks that can be accommodated and reduces the SOFC cooling requirement. The lowest costs of electricity are obtained at constant spool speed operation, while the highest efficiencies are reached at variable spool speed operation. Critical for the integration of off-the-shelf GTs, which historically have been designed for natural gas, is the surge margin. The largest surge margins are obtained by closing the compressor inlet guide vanes. Furthermore, higher SOFC fuel utilization factors are shown to increase the surge margin as the turbine firing temperature is decreased.

25 ENERGY STORAGE↗

Plant-wide modeling and techno-economic analysis of a direct non-oxidative methane dehydroaromatization process via conventional and microwave-assisted catalysis

Direct non-oxidative methane dehydroaromatization (DHA) process via conventional and microwave (MW)-assisted thermo-catalytic catalysis is studied. Rate models for methane DHA reactions, including the effect of catalyst deactivation, are developed by using the in-house experimental data. Model results for gas concentration profile and catalyst deactivation are in good agreement with the experimental data. This rate model is then used for the development of dynamic multi-scale, multi-physics commercial-scale reactor models. Total number of fixed bed reactors desired for a cyclic steady state process is estimated. Plant-wide models are then developed for conventional and MW-assisted processes for producing products of desired specifications. Techno-economic analysis of the methane DHA process is undertaken. Economics of these methane DHA processes are compared with the typical multi-step natural gas to aromatics production process via methanol synthesis. Sensitivity of internal rate of return (IRR) and net present value (NPV) to various economic and process parameters such as plant scale, desired rate of return, reactor cost, feedstock and utility cost, catalyst variable cost, and MW reactor cost is studied. Here, electric equivalent efficiency of the conventional methane DHA process is found to be 69.2 % and 67.3 % at 750 °C and 800 °C, respectively, while the MW-assisted methane DHA process has the electric equivalent efficiency of 48.9 % at 800 °C. IRRs of the conventional methane DHA process at 750 °C and 800 °C, and MW-assisted process are 15.2 %, 17.5 %, and 18.8 %, respectively for a methane feed flowrate of 19,782 kg/h, while the IRR of the multi-step natural gas to aromatics production process is estimated to be 0 % for the same plant scale. Impact of change in the methane price, electricity price, and catalyst cost is found to be considerable on the process economics, while the cost of the MW reactor is found to have negligible impact.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental demonstration of high-temperature (>1000 °C) heat extraction from a moving-bed oxidation reactor for thermochemical energy storage

Previously developed reduction-oxidation (redox) thermochemical energy storage technologies must store their products at high temperatures, complicating handling and transportation. This work describes a countercurrent, tubular, moving bed oxidation reactor at laboratory scale that produces high grade heat and allows solids to enter and exit the system at ambient temperatures. The particles implemented in the system consist of a novel magnesium manganese-oxide material well-suited for thermochemical energy storage. Output heat is obtained via a separate extraction gas flow, which exits from the middle portion of the main reactor tube. With this design, reactor temperatures in excess of 1000°C and extraction temperatures above 950°C were achieved. Deviation between the two measurements is a result of extraction thermocouple placement and losses in the reactor extraction arm; improvements to these parameters would bring the extraction temperature closer to the bed temperature. The reactor produces enough energy via oxidation to sustain both heat extraction and continued chemical reaction. During one representative steady state experiment at a particle flow rate of 1.5 g/s, an average of 447 W was extracted from the reactor out of an estimated 1083 W of released chemical energy for a duration of 70 minutes. Among the four experiments, the maximum bench-scale oxidation reactor energy efficiency of 36.2% and corresponding round-trip efficiency of 13.7% considering both redox reactors were demonstrated. Characteristics of an ideal system are considered and future improvements are proposed.

25 ENERGY STORAGE↗

Dual-module humidity pump for efficient air dehumidification: Demonstration and performance limitations

Condensation dehumidification in conventional air conditioning technologies is energy-intensive, accounting for up to 50% of building cooling energy used in some climates. Selective vacuum membrane dehumidification (VMD) is one of the leading alternative dehumidification technologies due to its potential for significant energy savings, and the “dual-module humidity pump” is one of the most promising VMD concepts. Here, this work is the first to provide experimental proof-of-concept for the dual-module humidity pump system and provides the first thermodynamic modeling framework that accounts for realistic steady-state operating limitations, both of which are lacking in the current literature. Additionally, this work is the first to provide a system design solution that overcomes practical challenges associated with air accumulation in the vacuum channels. The experimental results in this work show that the current prototype can remove up to 45% of the water vapor in the air stream, and the vapor pressure difference in the vapor rejection module needs to be approximately 2–4 times greater than that of the dehumidification module in order to maintain balanced mass transfer. The thermodynamic model applied to typical air conditioning conditions shows that the ideal dehumidification (latent) COPs can reach up to 40, but practical COPs are limited to approximately 10. Furthermore, the model shows that the overall energy efficiency increases as the membrane air selectivity increases, though this improvement gradually starts to diminish when the membrane selectivity is increased above 10,000.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Vehicle-to-Grid planning framework incorporating electric vehicle user equilibrium and distribution network flexibility enhancement

The rapid surge in electric vehicle (EV) adoption, coupled with advancements in charging technologies, emphasizes the critical necessity for expanding EV recharging infrastructure. Simultaneously, the Distribution Network (DN) encounters escalating challenges in meeting charging demand during peak traffic periods. Consequently, there is a mounting demand for the deployment of innovative Vehicle-to-Grid (V2G) technologies to augment the DN’s flexibility in power dispatch and alleviate travel costs for EV users. Hence, this paper proposes an EV-user-equilibrium-(UE)-constrained V2G planning framework that enhances flexibility in the DN. The framework aims to ascertain the optimal placement and capacity of EV charging stations (EVCSs) and V2G charging piles within the Transportation Network (TN). It takes into account the equilibrium condition stemming from competitive EV charging and routing behaviors alongside the optimal expansion of DN energy resources to accommodate the electricity supplied by the V2G piles. This study commences by analyzing EV drivers’ travel decisions, considering the influence of charging and V2G pile locations and sizes. Subsequently, we tackle the Traffic Assignment Problem with User Equilibrium (TAP-UE) model to characterize the steady-state traffic flow distribution of EVs. Following this, we formulate the optimization model for the Coordinated Power and Transportation Network (CPTN), which encompasses the optimal expansion of DN facilities and traffic flow regulation under UE conditions. To mitigate the computational complexity associated with the V2G planning model, we introduce a series of linearization methods to obtain a manageable Mixed-Integer Linear Programming (MILP) solution. Finally, to validate the efficacy of our proposed planning framework, we apply it to two test systems, including a real-world case study. Through these case studies, we explore the necessity and potential benefits of V2G technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigation of fouling mechanisms for diesel engine exhaust heat recovery

The effect of diesel engine exhaust fouling on heat and mass exchangers for waste heat recovery is investigated. Experiments are conducted for a range of operating conditions relevant to the use of the waste heat from a diesel engine for powering a 2.71 kW capacity absorption heat pump. Thermal resistances of fouling layers as well as their effects on pressure drop are determined, and the underlying mechanisms for deposition and removal are investigated. Fouling layer effects are most severe for the lowest coolant temperatures and 100% generator load. At these conditions, the fouling thermal resistance is approximately 70% of the total resistance, and the ratio of the steady-state pressure drop to the baseline pressure drop is 3.25. Flow induced shear is found to be the primary growth inhibiting mechanism at high exhaust velocities. Findings from this study can guide heat exchanger design for a variety of waste heat recovery systems.

04 OIL SHALES AND TAR SANDS↗

Performance evaluation of a Terry GS-2 steam impulse turbine with air-water mixtures

Terry steam turbines are widely used in various industries because of their robust design. Within the nuclear power generation industry, they are used in the Reactor Core Isolation Cooling System to remove decay heat during reactor isolation events. During the Fukushima Daiichi nuclear power station disaster in Japan in 2011, the Reactor Core Isolation Cooling System and associated Terry turbine operated for over 70 hours in Unit 2; this runtime is well beyond the expected operating duration. Theories suggest the turbine was subjected to a two-phase inlet flow, which could degrade the turbine performance. In this work, an experimental test rig was constructed to test a full-scale Terry model GS-2 steam turbine under two-phase air/water flows. Steady-state efficiency and torque performance maps of the turbine were developed over a range of turbine inlet pressures (1.38–4.83 bar or 20–70 psia), air mass fractions (0.05–1.0) and rotational speeds up to 4000 RPM. Furthermore, turbine performance followed expected trends with torque varying linearly and efficiency varying quadratically with rotational speed. In addition, high-speed images of the two-phase flow entering the turbine were also analyzed to understand how changes in inlet pressure and air mass fraction affect the flow regime and homogenization. The present tests with air–water two-phase mixtures are an important step towards providing an understanding of the full-scale Terry turbine’s behavior and performance curves under two-phase conditions. The results of this work will be combined with air/water and steam/water data gathered using a small-scale Terry ZS-1 steam turbine in order to understand the scaling relationship between large and small size Terry turbines and fluid pairs. The combined data set will enable further development of analytical models over a wide range of conditions and may be used to provide technical justification for expanded use of the Terry turbines in nuclear power plant safety systems and other systems.

42 ENGINEERING↗

Performance evaluation of a wrapped around condenser for heat pump water heater applications

In this report, accurate performance evaluation of a wrapped-around condenser for heat pump water heaters (WHPWH) is critical since the COP of the system depends heavily on thermal stratification and condenser design. An analytical, quasi-steady state heat balance method has been developed to determine the optimal spacing between adjacent channels, tube diameter, tube shape, and total refrigerant charge amount for the condenser. The heat transfer rate is compared among three approaches: the refrigerant thermodynamic model, the condenser-wrap fin model, and the analytical natural convection model on the inside of the tank for the three regions based on the refrigerant phase (e.g., super-heated, saturated, or subcooled). The heat transfer rate was predicted by a combination of slug-plug and annular flow for a D-shaped helical tube. Experimental data were used as boundary conditions for validating the model. The rate of heat transfer based on tube shape and tank wall temperatures was compared by CFD analysis. Parametric analysis indicates a tradeoff between refrigerant mass, pressure drop, tube diameter, and tube length to maximize the heat transfer rate. The model suggests the saturated region length can be extended by 400%, and the condenser pressure drop can be reduced by 23% with an optimal spacing pattern.

42 ENGINEERING↗

Advances in supervisory control strategies for a heat pump centric HVAC system − a comprehensive review on applications

There is an increase in research investigating the development and deployment of supervisory controllers that enable high efficiency electrically driven vapor compression heat pumps operating within grid interactive efficient buildings to provide demand side management. This paper reviews over sixty relevant case studies within this domain that focus on commercial off-the-shelf heat pumps whose primary task is providing space conditioning. The concept of a heat pump-centric heating, ventilation, and air-conditioning system is introduced, accompanied by a detailed overview of various kinds of electric heat pumps and building-level thermal energy storage configurations. Additionally, the different types of supervisory controller designs, including rule-based control and model predictive control, are discussed, along with the various methods for communication between a supervisory controller and a downstream heat pump’s local controller. A comparative analysis is conducted in order to categorize the reviewed case studies based on their system design, supervisory control algorithm, and validation methodology. This detailed analysis allows the review to establish current research trends, identify potential gaps, and suggest future directions for the development of this technology. Overall, the authors recommend that more future research be devoted to low-cost practical retrofits that allow for easy integration of active thermal energy storage within heat pump-centric heating, ventilation, and air-conditioning system systems that utilize direct expansion heat pumps. We also suggest more research into the development and deployment of supervisory controllers that can properly communicate with commercial off-the-shelf heat pump local controller available control inputs, e.g., zone temperature setpoint. Lastly, more rigorous experimental demonstrations of advanced supervisory control within real and or closed-loop, transient/ quasi-steady state environments are necessary to reduce industry wide skepticism of this technology.

Demand side management↗

CFD modeling of natural circulation in LiCl-KCl molten salt closed loop

Characterizing flow within a molten salt closed-loop system is crucial for assessing system requirements, evaluating performance, and identifying potential flaws. Direct flow measurement using instrumentation is challenging due to extreme environmental conditions and the limitations associated with measuring molten salt flow under natural convection. Here, this study aims to provide comprehensive insights into the thermal-hydraulic behavior of a closed loop, with a particular focus on temperature distribution and velocity prediction. The Computational Fluid Dynamics (CFD) model demonstrated the capability to effectively simulate and predict both temperature distributions and flow velocities within the molten salt loop. The CFD model's predictive capability was validated by its ability to replicate temperature measurements under varying boundary conditions. The analysis revealed that the CFD model tends to underpredict temperatures in the cold leg and overpredict them in the hot leg, highlighting the need for continuous model refinement and acknowledging the limitations of using a steady-state approach. Furthermore, the potential of using external temperature measurements to estimate internal molten salt temperatures and predict flow velocity was explored, revealing that this approach could introduce up to a 5.5% error in flow velocity calculations. Line probes mapping temperature distributions across the tube's cross-section and molten salt provided valuable insights into temperature gradients, emphasizing the need for a thermal conductivity equation for molten salt with lower uncertainty to achieve more accurate temperature predictions of the system.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Non-dimensional performance and safety parameters for heat pipes

The use of heat pipes in safety-critical systems such as nuclear microreactors dictates the development of generalized, practical, scalable performance and safety parameters. Traditional dimensional metrics, while informative, lack the universality required for comparative analysis across varying designs and operating regimes. Here, this work introduces a comprehensive set of non-dimensional parameters to characterize heat pipe performance and safety, including capillary performance, effective thermal conductivity, response time, exergetic efficiency, allowable temperature gradients, allowable rate of temperature change, priming coefficients, and factor of safety. A reference heat pipe design representative of microreactor applications was analyzed via the developed parameters using both traditional analytical models and Sockeye simulations under transient and steady-state conditions. Sodium, potassium, and water were evaluated as working fluids to demonstrate the applicability of the framework across a broad temperature range. The proposed non-dimensional parameters effectively captured key thermal-hydraulic behaviors and safety concerns, as was demonstrated via Sockeye simulations. This framework supports the development of design optimization strategies, operational protocols, and safety assurance practices for advanced reactor systems and other high-reliability applications.

42 - ENGINEERING↗

Theoretical analysis of a refrigerant injection-enhanced air source heat pump with thermal energy storage for extended cold-climate and defrosting operations

This study investigates a conceptual refrigerant injection-enhanced air source heat pump with integrated thermal energy storage (ITES-ASHP) that combines two-phase flash tank injection with phase change material (PCM) thermal energy storage (TES) to extend cold-climate operation and maintain indoor heating during defrost. A steady-state, mode-based thermodynamic cycle model is developed to evaluate heating and defrosting modes with and without refrigerant injection and TES integration over an outdoor temperature range of 8 to −25 °C. The framework is applied to refrigerants R-290, R-454B, R-410 A, and R-32. A parametric study is conducted for an 18-kW system rated for an outdoor temperature of 8 °C, with the compressor frequency scheduled to 150 Hz. The optimal PCM phase-change temperature is identified as 20 °C for R-290, R-454B, and R-410 A, and 15 °C for R-32. At the design condition of −25 °C outdoor temperature, the proposed concept achieves a combined COP of 2.22 for R-290, corresponding to a 60% increase relative to the theoretical single-stage baseline for combined heating and defrosting operation. Safety screening based on compressor discharge temperature (≤ 120 °C) and injection quality (≥ 0.65), together with performance evaluation, indicates that R-290 is the most suitable candidate, followed by R-410 A and R-454B. Under the assumptions and constraints used here, R-32 is found to be less suitable due to excessive discharge temperatures and a higher risk of wet compression.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evidence of redox cycling as a sub-mechanism in hydrogen production during ethanol steam reforming over La 0.7 Sr 0.3 MnO 3-x perovskite oxide catalysts

Ethanol steam reforming (ESR) is of societal interest. Here, in this work, experiments were conducted to ascertain if some of the H 2 is produced by a redox cycle involving H 2 O filling oxygen vacancies over reducible oxide catalysts. Redox cycling experiments were performed over La 0.7 Sr 0.3 MnO 3-x (100) in ultra-high vacuum. It was found that H 2 was produced from redox cycling with alternating ethanol and water exposures over La 0.7 Sr 0.3 MnO 3-x (100), with both half-cycles occurring at temperatures ≤800 K. In the first half-cycle, ethanol ‘directly’ reduced the surface to create oxygen vacancies (not by a CO intermediate), and in the second half-cycle water filled oxygen vacancies to make H 2 . The H 2 production during the water exposure has a half-cycle turnover frequency of >3.2 × 10 -2 molecules site -1 s -1 in the temperature range of 700–800 K, which is fast enough to be part of the ESR full catalytic cycle. Flowing both reactant gases together, ethanol and water, over La 0.7 Sr 0.3 MnO 3-x (100) and La 0.7 Sr 0.3 MnO 3-x powders significantly increases hydrogen production compared to pure ethanol. The results suggest that steady state ESR includes a sub-mechanism of ethanol ‘directly’ reducing the surface to create oxygen vacancy, and water filling oxygen vacancy to make some of the H 2 by a Mars van Krevelen type mechanism.

08 HYDROGEN↗

Time-resolved electrical potential pump – X-ray photoelectron spectroscopy probe developments for investigating dynamic processes occurring at electrochemical interfaces

Electrode–electrolyte interfaces are of critical importance in several fields, including renewable energy, corrosion, and environmental chemistry. However, investigating these interfaces under operational conditions poses considerable challenges due to the limitations of the instrumentation employed. While recent advancements in in situ and operando techniques have enhanced our comprehension of the steady-state properties of solid-liquid interfaces, the dynamic behaviors of these systems remain inadequately explored. This study introduces a time-resolved X-ray photoelectron spectroscopy (XPS) technique designed to capture transient reaction intermediates and charging dynamics at electrified interfaces. The presented proof-of-principle study demonstrates that electrochemical processes, represented by an equivalent electrical circuit (EEC) model, can be probed and understood using square wave voltage pulses of a potentiostat synchronized to the modified data acquisition of an XPS setup. This method offers a valuable alternative to traditional pump–probe techniques, facilitating the investigation of a broader range of electrochemical systems. A dedicated software package for analyzing time- and energy-resolved XPS with a focus on extracting parameters of the EEC is geared towards benchmarking different EECs in future real-world electrochemical experiments.

Electrochemistry↗