Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Signal processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Laboratory Instrument Software Controlled Spread Spectrum Time Domain Reflectometry for Electrical Cable Testing

This research discusses development of a software-controlled laboratory instrument based spread spectrum time domain reflectometry system (SSTDR). This constitutes one task within PNNL’s Light Water Sustainability Program (LWRS) whose mission includes advancing nondestructive examination (NDE) techniques for off-line and on-line in-situ cable condition monitoring. In 2022, PNNL evaluated SSTDR for detection and characterization of a number of cable anomalies (Glass et al. 2022). The review included comparison of SSTDR to Frequency Domain Reflectometry (FDR) techniques which have enjoyed encouraging feedback and are starting to be used in nuclear power plants for periodic cable condition monitoring of cable systems as part of the plant’s overall cable aging management program. The FDR test introduces a broad-band chirp onto the cable at the cable end then listens for any reflection from a change of impedance along the cable caused by a damaged conductor or insulation, splices, contact with moisture, or other cable anomalies. The signal is captured in the frequency domain then transformed back to the time domain using an inverse Fourier transform (IFT). Based on the velocity of propagation, the impedance response signal is plotted against distance along the cable. Peak locations along the X-axis indicate the distance along the cable where a portion of the signal has been reflected back to the instrument as a result of a cable anomaly. The FDR test is considered the gold standard of reflectometry however it does require the cable to be de-energized to perform the test. The LIVEWIRE commercial SSTDR produces a similar plot to the FDR however all processing is in the time domain. A pseudo-random noise code (PN code) is input onto the cable conductor and the instrument listens for any reflected response from cable anomalies. The SSTDR processes the signal as an autocorrelation comparing the input PN code to any reflected signal detected. The autocorrelation analysis for thermal aging, water and water ingress detection, ground fault and phase-to-phase fault detection at various locations along the cable and with the cable attached and detached from a motor load, and on both energized and un-energized conditions were performed. These results were contrasted to Frequency Domain Reflectometry (FDR) measurements of the un-energized cable. Results were encouraging but indicated more work was warranted – particularly with the SSTDR, it seemed that the insulation damage would likely be better evaluated with multiple bandwidth cable tests particularly including larger bandwidths than were possible with the current commercial instrument. The commercial instrument’s bandwidth was set at 6, 12, 24, and 48MHz but note that SSTDR and FDR definitions of bandwidth trend similarly but are not the same. The FDR response could be more broadly adjusted, and the bandwidth of 100 to 500 MHz produced the best responses. FDR responses to anomalies were clearer than SSTDR responses and indications were that a broader bandwidth SSTDR may lead to improved SSTDR detection capability. This project used a laboratory instrument based SSTDR (primarily using an Arbitrary Waveform Generator (AWG) and a digital oscilloscope plus Python in-house software) that allowed software adjustment of the SSTDR bandwidth, window functions applied to the exciting Pseudo-random Noise (PN) code plus and other aspects of the SSTDR signal processing. Hereafter, this will be referred to as the PNNL SSTDR. Evaluating specific performance of the PNNL SSTDR is left to a separate report. This report documents hardware and software development to produce the SSTDR cable test system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Model selection and signal extraction using Gaussian Process regression

We present a novel computational approach for extracting localized signals from smooth background distributions. We focus on datasets that can be naturally presented as binned integer counts, demonstrating our procedure on the CERN open dataset with the Higgs boson signature, from the ATLAS collaboration at the Large Hadron Collider. Our approach is based on Gaussian Process (GP) regression — a powerful and flexible machine learning technique which has allowed us to model the background without specifying its functional form explicitly and separately measure the background and signal contributions in a robust and reproducible manner. Unlike functional fits, our GP-regression-based approach does not need to be constantly updated as more data becomes available. We discuss how to select the GP kernel type, considering trade-offs between kernel complexity and its ability to capture the features of the background distribution. We show that our GP framework can be used to detect the Higgs boson resonance in the data with more statistical significance than a polynomial fit specifically tailored to the dataset. Finally, we use Markov Chain Monte Carlo (MCMC) sampling to confirm the statistical significance of the extracted Higgs signature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Systems and methods for detection of occupancy using radio waves

Systems and methods are disclosed for detecting a presence of a person in an area of coverage using radar. A transmitter can transmit radio signals in a first direction in an area of coverage defined by a wall and a floor. A receiver can receive the transmitted radio signals reflected back from the area of coverage. A signal conditioning circuit can process the received radio signals. One or more hardware processors can be programmed to analyze the processed radio signals and detect a presence of a person in the area of coverage based on the analysis. The analysis of the processed signals can be performed in both time and frequency domain. In addition to radar, an input from an infrared sensor can also be used in conjunction with radar based detection.

42 ENGINEERING↗

Analysis of diagnostic calorimeter data by the transfer function technique

This paper describes the analysis procedure applied to the thermal measurements on the rear side of a carbon fibre composite calorimeter with the purpose of reconstructing the energy flux due to an ion beam colliding on the front side. The method is based on the transfer function technique and allows a fast analysis by means of the fast Fourier transform algorithm. Its efficacy has been tested both on simulated and measured temperature profiles: in all cases, the energy flux features are well reproduced and beamlets are well resolved. Limits and restrictions of the method are also discussed, providing strategies to handle issues related to signal noise and digital processing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a 1D-imaging high-energy x-ray backlighter driven by the National Ignition Facility Advanced Radiographic Capability laser

Plastic deformation of samples compressed to Mbar pressures at high strain rates at the National Ignition Facility (NIF) forms the basis of ongoing material strength experiments in conditions relevant to meteor impacts, geophysics, armor development, and inertial confinement fusion. Hard x-ray radiography is the primary means of measuring the evolution of these samples, typically employing a slit-collimated high-Z microdot driven by the NIF laser to generate >40 keV x rays [E. Gumbrell et al., Rev. Sci. Instrum. 89, 10G118 (2018) and C. M. Huntington et al., Rev. Sci. Instrum. 89, 10G121 (2018)]. Alternatively, a dysprosium “micro-flag” target driven by the Advanced Radiographic Capability laser (~2 kJ, 10 ps) can deliver significantly higher spatiotemporal resolution [M. P. Hill et al., Rev. Sci. Instrum. 92, 033535 (2021)], especially in high-opacity samples. Here, initial experiments revealed problematic brightness and spectral gradients from this source, but by radiographing a set of diamond-turned, 105 µm-thick Pb test objects and supported by simulations using the 3D Monte Carlo code GEANT4, these geometry-dependent gradients across the field of view are quantified and mitigation strategies are assessed. In addition to significantly enhancing the modulation transfer function compared to the existing system, image stacking from multiple layers of image plate is shown to almost double the signal to noise ratio that will reduce uncertainties in future dynamic strength experiments.

47 OTHER INSTRUMENTATION↗

High-sensitivity electronic Stark spectrometer featuring a laser-driven light source

We report developmental details of a high-sensitivity Stark absorption spectrometer featuring a laser-driven light source. The light source exhibits intensity fluctuations of ~0.3% over timescales ranging from 1 min to 12 h, minimal drift (≤0.1%/h), and very little 1/f noise at frequencies greater than 200 Hz, which are comparable to or better than an arc-driven light source. Additional features of the spectrometer include balanced detection with multiplex sampling, which yielded lower noise in A, and constant wavelength or wavenumber (energy) spectral bandpass modes. We achieve noise amplitudes of ~7 × 10 –4 and ~6 × 10 –6 in measurements of single A and ΔA spectra (with 92 data points) taking ~7 and ~19 min, respectively.

47 OTHER INSTRUMENTATION↗

Deep learning-driven super-resolution in Raman hyperspectral imaging: Efficient high-resolution reconstruction from low-resolution data

Deep learning (DL) has become an indispensable tool in hyperspectral data analysis, automatically extracting valuable features from complex, high-dimensional datasets. Super-resolution reconstruction, an essential aspect of hyperspectral data, involves enhancing spatial resolution, particularly relevant to low-resolution hyperspectral data. Yet, the pursuit of super-resolution in hyperspectral analysis is fraught with challenges, including acquiring ground truth high-resolution data for training, generalization, and scalability. The pressing issue of extended spectral acquisition times, notably for high-resolution scans, is a significant roadblock in hyperspectral imaging. Super-resolution methods offer a promising solution by providing higher spatial resolution data to expedite data collection and yield more efficient outcomes. This paper delves into a practical application of these concepts using Raman imaging, where spectral acquisition times can be prohibitively long. In this context, DL-based super-resolution models demonstrate their efficacy by predicting and reconstructing high-resolution Raman data from low-resolution input, eliminating the need for resource-intensive high-resolution scans. While previous work often relied on substantial high-resolution datasets, this study showcases the ability to achieve similar outcomes even with limited data, presenting a more practical and cost-effective approach. In conclusion, the results offer a glimpse into the transformative potential of this technology to streamline hyperspectral imaging applications by saving valuable time and resources through the successful generation of high-resolution data from low-resolution inputs.

42 ENGINEERING↗

A platform to measure isentropes from proton-heated warm dense matter on short pulse laser facilities

We describe the development of an experimental platform that measures the release isentrope of materials heated isochorically to temperatures of a few electron volts, using short-pulse laser-produced protons to heat the sample and long-pulse laser-produced x rays to perform streaked x-ray radiography. The density profiles derived from the radiography data are integrated to generate pressure–density isentropes, independent of prior knowledge of the equation of state of the sample material. In order to understand the sensitivities of isentrope extraction from radiography data, we analyze synthetic radiographs generated by a radiation hydrodynamics code. Noise reduction and high spatial resolution are critical for isentrope reconstruction, as demonstrated by the analysis of a proof-of-principle shot day on the OMEGA-EP facility. In conclusion, the data demonstrate the feasibility of the platform for characterizing isentropes, and we discuss the necessary improvements to enhance precision in differentiating between equation-of-state models.

Equations of state↗

Infrasound direction of arrival determination using a balloon-borne aeroseismometer

Free-floating balloons are an emerging platform for infrasound recording, but they cannot host arrays sufficiently wide for multi-sensor acoustic direction finding techniques. Because infrasound waves are longitudinal, the balloon motion in response to acoustic loading can be used to determine the signal azimuth. This technique, called “aeroseismometry,” permits sparse balloon-borne networks to geolocate acoustic sources. This is demonstrated by using an aeroseismometer on a stratospheric balloon to measure the direction of arrival of acoustic waves from successive ground chemical explosions. A geolocation algorithm adapted from hydroacoustics is then used to calculate the location of the explosions.

47 OTHER INSTRUMENTATION↗

Assessment methods for determining small changes in hearing performance over time

Although the behavioral pure-tone threshold audiogram is considered the gold standard for quantifying hearing loss, assessment of speech understanding, especially in noise, is more relevant to quality of life but is only partly related to the audiogram. Metrics of speech understanding in noise are therefore an attractive target for assessing hearing over time. However, speech-in-noise assessments have more potential sources of variability than pure-tone threshold measures, making it a challenge to obtain results reliable enough to detect small changes in performance. Here, this review examines the benefits and limitations of speech-understanding metrics and their application to longitudinal hearing assessment, and identifies potential sources of variability, including learning effects, differences in item difficulty, and between- and within-individual variations in effort and motivation. We conclude by recommending the integration of non-speech auditory tests, which provide information about aspects of auditory health that have reduced variability and fewer central influences than speech tests, in parallel with the traditional audiogram and speech-based assessments.

60 APPLIED LIFE SCIENCES↗

Evaluating factors influencing infrasonic signal detection and automatic processing performance utilizing a regional network

Physical and deployment factors that influence infrasound signal detection and assess automatic detection performance for a regional infrasound network of arrays in the Western U.S. are explored using signatures of ground truth (GT) explosions (yields). Despite these repeated known sources, published infrasound event bulletins contain few GT events. Arrays are primarily distributed toward the south-southeast and south-southwest at distances between 84 and 458 km of the source with one array offering azimuthal resolution toward the northeast. Events occurred throughout the spring, summer, and fall of 2012 with the majority occurring during the summer months. Depending upon the array, automatic detection, which utilizes the adaptive F-detector successfully, identifies between 14% and 80% of the GT events, whereas a subsequent analyst review increases successful detection to 24%–90%. Combined background noise quantification, atmospheric propagation analyses, and comparison of spectral amplitudes determine the mechanisms that contribute to missed detections across the network. This analysis provides an estimate of detector performance across the network, as well as a qualitative assessment of conditions that impact infrasound monitoring capabilities. Finally, the mechanisms that lead to missed detections at individual arrays contribute to network-level estimates of detection capabilities and provide a basis for deployment decisions for regional infrasound arrays in areas of interest.

58 GEOSCIENCES↗

Wind-To-Hydrogen Energy Pilot Project

WIND-TO-HYDROGEN ENERGY PILOT PROJECT: BASIN ELECTRIC POWER COOPERATIVE In an effort to address the hurdles of wind-generated electricity (specifically wind's intermittency and transmission capacity limitations) and support development of electrolysis technology, Basin Electric Power Cooperative (BEPC) conducted a research project involving a wind-to-hydrogen system. Through this effort, BEPC, with the support of the Energy & Environmental Research Center at the University of North Dakota, evaluated the feasibility of dynamically scheduling wind energy to power an electrolysis-based hydrogen production system. The goal of this project was to research the application of hydrogen production from wind energy, allowing for continued wind energy development in remote wind-rich areas and mitigating the necessity for electrical transmission expansion. Prior to expending significant funding on equipment and site development, a feasibility study was performed. The primary objective of the feasibility study was to provide BEPC and The U.S. Department of Energy (DOE) with sufficient information to make a determination whether or not to proceed with Phase II of the project, which was equipment procurement, installation, and operation. Four modes of operation were considered in the feasibility report to evaluate technical and economic merits. Mode 1 - scaled wind, Mode 2 - scaled wind with off-peak, Mode 3 - full wind, and Mode 4 - full wind with off-peak In summary, the feasibility report, completed on August 11, 2005, found that the proposed hydrogen production system would produce between 8000 and 20,000 kg of hydrogen annually depending on the mode of operation. This estimate was based on actual wind energy production from one of the North Dakota (ND) wind farms of which BEPC is the electrical off-taker. The cost of the hydrogen produced ranged from $20 to $10 per kg (depending on the mode of operation). The economic sensitivity analysis performed as part of the feasibility study showed that several factors can greatly affect, both positively and negatively, the "per kg" cost of hydrogen. After a September 15, 2005, meeting to evaluate the advisability of funding Phase II of the project DOE concurred with BEPC that Phase I results did warrant a "go" recommendation to proceed with Phase II activities. The hydrogen production system was built by Hydrogenics and consisted of several main components: hydrogen production system, gas control panel, hydrogen storage assembly and hydrogen-fueling dispenser The hydrogen production system utilizes a bipolar alkaline electrolyzer nominally capable of producing 30 Nm3/h (2.7 kg/h). The hydrogen is compressed to 6000 psi and delivered to an on-site three-bank cascading storage assembly with 80 kg of storage capacity. Vehicle fueling is made possible through a Hydrogenics-provided gas control panel and dispenser able to fuel vehicles to 5000 psi. A key component of this project was the development of a dynamic scheduling system to control the wind energy's variable output to the electrolyzer cell stacks. The dynamic scheduling system received an output signal from the wind farm, processed this signal based on the operational mode, and dispatched the appropriate signal to the electrolyzer cell stacks. For the study BEPC chose to utilize output from the Wilton wind farm located in central ND. Site design was performed from May 2006 through August 2006. Site construction activities were from August to November 2006 which involved earthwork, infrastructure installation, and concrete slab construction. From April - October 2007, the system components were installed and connected. Beginning in November 2007, the system was operated in a start-up/shakedown mode. Because of numerous issues, the start-up/shakedown period essentially lasted until the end of January 2008, at which time a site acceptance test was performed. Official system operation began on February 14, 2008, and continued through the end of December 2008. Several issues continued to prevent consistent operation, resulting in operation of the system in fits and starts. During the operational period, three ramp tests were performed on the electrolyzer cell stacks to evaluate cell stack degradation, if present. In addition, from December 23 - 30 2008, the hydrogen system was operated using Mode 1 protocol. From February 14, 2008 - December 31, 2008, the system produced a total of just less than 26,000,000 liters (2320 kg), including approximately 3,300,000 liters (295 kg) of hydrogen during Mode 1 operation. Unfortunately, the chronic shutdown issues prevented consistent operation and, therefore, did not allow for any accurate economic analysis as originally intended. With that said, much valuable experience was gained in the form of "lessons learned," and the project served as an extremely valuable platform for educating the public.

17 WIND ENERGY↗

Health monitoring device

Example aspects of a volatile organic compound detection device, a wearable health monitoring device, and a method of monitoring a user's health are disclosed. The volatile organic compound detection device can comprise a collector comprising a collector material configured to collect volatile organic compounds given off from a user's skin; a separator comprising a gas chromatography column configured to separate mixtures of the volatile organic compounds into their constituent chemicals; and an identifier comprising a detector and a processor, the detector configured to transduce the constituent chemicals into a signal, the processor configured to process the signal to identify specific volatile organic compounds indicative of a health condition.

42 ENGINEERING↗

Integrated circuit for processing a low-frequency signal from a seismic detector

Specific features for the detection and processing of a low-frequency signal from a seismic detector are considered in terms of an integrated circuit based on a large matrix crystal of the 5507 series. This integrated circuit is designed for the detection of human movements. The specific features of the information signal, obtained at the output of the seismic detector, and the main characteristics of the integrated circuit and its structure are reported.

36 MATERIALS SCIENCE↗