Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Signal detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Discovering hydrothermalism from Afar: In Situ methane instrumentation and change-point detection for decision-making

Seafloor hydrothermalism plays a critical role in fundamental interactions between geochemical and biological processes in the deep ocean. A significant number of hydrothermal vents are hypothesized to exist, but many of these remain undiscovered due in part to the difficulty of detecting hydrothermalism using standard sensors on rosettes towed in the water column or robotic platforms performing surveys. Here, we use in situ methane sensors to complement standard sensing technology for hydrothermalism discovery and compare sensors on a towed rosette and an autonomous underwater vehicle (AUV) during a 17 km long transect in the Northern Guaymas Basin in the Gulf of California. This transect spatially intersected with a known hydrothermally active venting site. These data show that methane signalled possible hydrothermal-activity 1.5–3 km laterally (100–150 m vertically) from a known vent. Methane as a signal for hydrothermalism performed similarly to standard turbidity sensors (plume detection 2.2–3.3 km from reference source), and more sensitively and clearly than temperature, salinity, and oxygen instruments which readily respond to physical mixing in background seawater. We additionally introduce change-point detection algorithms—streaming cross-correlation and regime identification—as a means of real-time hydrothermalism discovery and discuss related data supervision technologies that could be used in planning, executing, and monitoring explorative surveys for hydrothermalism.

58 GEOSCIENCES↗

Characterizing the γ-Ray Emission from Low-luminosity AGN

A majority of the active galactic nuclei (AGN) in the local Universe are classified as low-luminosity AGN (LLAGN), having bolometric luminosities ≲10 42 erg s −1 . Although high-energy γ-ray emission is predicted from both the jets and disks of LLAGN, to date only four have been detected by the Fermi Large Area Telescope (Fermi-LAT). In this work, we therefore conduct a comprehensive study of all the LLAGN from the Palomar spectroscopic survey of bright, northern galaxies, including both subthreshold and detected γ-ray sources, using 14.4 yr of LAT data. Our analysis results in a new detection of one LLAGN, as well as a detection of the subthreshold population using a stacking technique. We find that the signal from the subthreshold sample is consistent with being dominated by star formation activity, although a contribution from compact jets or a mixed contribution from jetted and nonjetted systems is also feasible. On the other hand, the individually detected LLAGN are likely dominated by jet emission. We perform detailed spectral modeling for a subset of these sources and find that the γ-ray signal can be explained by synchrotron self-Compton radiation if the inner jet emission region is weakly magnetized, with its total energy density being strongly particle dominated and only slowly moving. With this work we also publicly release our Python-based stacking library for analyzing subthreshold source populations with the LAT based on a proven technique used in numerous studies.

79 ASTRONOMY AND ASTROPHYSICS↗

Baltimore Social-Environmental Collaborative (BSEC) Doppler Lidar & Derived Products

This repository contains all processed Doppler‐lidar outputs from the PSU lidar deployed for the Baltimore Social‐Environmental Collaborative (BSEC) project. Vertical Stare Scans (fixed‐beam, vertical profiling): 1 Hz backscatter intensity (m⁻¹ sr⁻¹), signal‐to‐noise ratio (unitless), and Doppler vertical‐velocity (m s⁻¹) on ~30 m range gates, stored as CF-compliant NetCDF. Wind Profiles (horizontal‐wind retrieval): daily NetCDF outputs of retrieved horizontal wind speed (m s⁻¹) and direction (degrees), computed from the angled‐scan returns. Profile Statistics (summary statistics on the vertical velocity): 15 min windows (default) of mean, variance, skewness, kurtosis, high-frequency variance, etc., as a function of height; saved as CF-compliant NetCDF files. Boundary Layer Height (BLH) (fuzzy-logic output): 15 min BLH estimates (m), with lower/upper fuzzy bounds (m) and a quality flag (0–4) indicating data status (e.g., no data, good, below range, ran out of signal, cloud-topped). Cloud Base Height (Haar-gradient detection): 15 min estimates of cloud-base height (m) with a cloud-detection quality flag (0–3: none, low, moderate, high). All five product streams are organized by year and date under their own top-level folders (01_Vertical_Stare_Scans/ through 05_Cloud_Height/). Each folder contains a data_ /YYYY/ subdirectory with daily CF-compliant NetCDF outputs (96 windows per day at 15 min intervals). Global attributes in each file include creation history, version (2.0.0), institution, and source. Instrument & MeasurementsThe PSU Doppler Lidar samples aerosol backscatter (m⁻¹ sr⁻¹), signal-to-noise ratio, and radial velocity at ~1 Hz. Vertical stare scans point the beam straight up; after collecting angled scans through multiple elevation angles, the "Wind Profiles" product contains the fully retrieved horizontal wind speed and direction. Data were collected continuously at ~30 m range resolution, with a typical height ceiling of ~12 km. How to Use Open any NetCDF with Python's xarray, MATLAB, or similar CF-compliant tools. Stare scans and angled-scan retrievals (Wind Profiles) are CF-compliant daily NetCDF files. Profile-Statistics, BLH, and Cloud Height files are daily 15 min summaries (96 time steps per file). Inspect the included variables (e.g., vertical_velocity_variance, wind_speed, BLH, cloud_base_height) for your analyses. Use the quality flags (BLH_flag, cloud_flag) to filter out poor-quality retrievals. For more information or questions about processing methods, please contact:Nicholas E. Prince ⟨nec5299@psu.edu⟩Penn State Department of Meteorology & Atmospheric Science

Air Quality↗

An improved synthetic signal injection routine for the Haloscope At Yale Sensitive To Axion Cold dark matter (HAYSTAC)

Microwave cavity haloscopes are among the most sensitive direct detection experiments searching for dark matter axions via their coupling to photons. When the power of the expected microwave signal due to axion–photon conversion is on the order of 10 −24 W, having the ability to validate the detector response and analysis procedure by injecting realistic synthetic axion signals becomes helpful. Here, we present a method based on frequency hopping spread spectrum for synthesizing axion signals in a microwave cavity haloscope experiment. It allows us to generate a narrow and asymmetric shape in frequency space that mimics an axion’s spectral distribution, which is derived from a Maxwell–Boltzmann distribution. In addition, we show that the synthetic axion’s power can be calibrated with reference to the system noise. Further, compared to the synthetic axion injection in the Haloscope At Yale Sensitive to Axion Cold dark matter (HAYSTAC) Phase I, we demonstrated synthetic signal injection with a more realistic line shape and calibrated power.

47 OTHER INSTRUMENTATION↗

Enhancing Automotive Intrusion Detection Through Multi-Modal Fusion: A CAN FD-LiDAR Approach

As vehicles become smarter and more autonomous, they increasingly depend on advanced sensors and communication technologies to operate securely. However, such growing dependence on technology—whether it’s CAN (Controller Area Network) for internal communication or LiDAR (Light Detection and Ranging) for sensing the world around them—also expands the attack surface for the types of cyber attacks. Traditional intrusion detection systems (IDS) typically monitor these systems in isolation, limiting their ability to detect sophisticated, crosssystem attacks. To address this, we propose a multi-modal fusion approach that combines real-world CAN FD signals (from the HCRL dataset) with LiDAR features (from the nuScenes dataset) to enhance attack detection. Our method employs a twostage ensemble approach. Calibrated XGBoost and LightGBM models initially process CAN FD (Fuzzing Data) and LiDAR data independently, detecting timing anomalies and space abnormalities. They are subsequently logarithmically combined with a logistic regression meta-model along with 17 engineered features capturing cross-modal behavior, prediction conflicts, and nonlinear interactions. This approach achieves an AUC of 0.87 and an F1-score of 0.82, surpassing single-modality baselines and early fusion methods, at merely 2 ms inference latency. Compared with deep learning competitors, it is 3 times more efficient, providing a lightweight, interpretable, and real time solution to automotive cybersecurity.

97 MATHEMATICS AND COMPUTING↗

FRET Based Biosensors for CBRN Threat Detection

Biosensors are devices used to detect the presence/concentration of a biological analyte. Biosensors consist of three parts: 1) a component that recognizes the analyte and produces a signal, 2) a signal transducer, and 3) a reader device. A multiplexed biosensor combines different biosensors for increased detection capabilities.

Demers, Steven M.↗

Signals of millicharged dark matter in light-shining-through-wall experiments

We discuss a novel detection technique for millicharged dark matter that makes use of existing light-shining-through-wall (LSW) experiments searching for massive dark photons. Since millicharged particles interact with both the visible and dark sectors, a small background of such particles enables the search for visible signals even in the limit of a massless dark photon. Furthermore, for sufficiently large couplings, a small dark matter subcomponent consisting of millicharged particles can have a terrestrial abundance that is significantly enhanced with respect to its galactic abundance. We leverage this fact to show that in certain parts of parameter space, future runs of the LSW Dark SRF experiment can be used to set the strongest limits on millicharged relics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Illumination of Damage in Intact Rocks by Ultrasonic Transmission-Reflection and Digital Image Correlation

aboratory-scale experiments on intact rocks are critical to the development of physics-based fundamental understanding of various geophysical phenomena. In this work, the capability of ultrasonic wave transmission (T-mode) and reflection (R-mode) to monitor damage progression in uniaxially loaded prismatic intact rock specimens has been analyzed, as it is imperative to study the observations and document the capabilities of these techniques in a controlled environment. This study is novel in the sense that the R-mode linear ultrasonic testing (LUT) has been rarely employed in studying intact rock damage processes in a laboratory setting, with most of the studies utilizing a direct transmission (T-mode) approach or focusing on macroscopically fractured material. The two-dimensional digital image correlation (2-D DIC) full-field strain measurement approach was also used in-sync with the LUT monitoring to explicitly correlate the stress-induced damage in the specimens with the changes observed in the ultrasonic (T-mode and R-mode) signals. The results show that both the T-mode and R-mode LUT approaches are sensitive to detect the evolution of tensile and shear damage in the specimens, with the R-mode ultrasonic signals showing higher degree of sensitivity to the damage in the rocks, immediately following the initiation of damage in the rock volume.

58 GEOSCIENCES↗

PARP1-HPF1 structure and dynamics on nicked DNA suggest a mechanism for acute and localized ADP-ribosylation

PARP1 detection of DNA strand breaks allosterically leads to PARP1 synthesis of poly(ADP-ribose) modifications that signal DNA damage. HPF1 engages activated PARP1 to control modification site selection. Understanding of the mechanism of DNA break detection and catalytic activation is incomplete, due largely to limited structural information for full-length PARP1. Here, single-particle cryo-EM provides views of the full complement of PARP1 domains engaging a DNA single-strand break in the presence of HPF1 and a fragment of binding partner Timeless. Cryo-EM, single-molecule DNA dynamics, and small-angle X-ray scattering analysis indicate that PARP1 remains dynamic even when the multi-domain structure is organized on a DNA break, with the minimal catalytic region displaying high mobility relative to domains engaging damage. We propose that the organization of PARP1 domains on a DNA break releases a tethered, constitutively active catalytic region to modify molecules in a radius surrounding the DNA break site.

59 BASIC BIOLOGICAL SCIENCES↗

Detection of Isotopes in Urban Source Search Gamma Spectra Using Hopfield Neural Network

Source search campaigns involve the measurement of consecutive background gamma-ray spectra obtained with a mobile detector-spectrometer, such as tellurium-doped sodium iodide NaI(Tl) scintillator detector-spectrometer. Counts are measured with NaI(Tl) detector in short acquisition intervals, such as one second. Detection of isotopes in search data is challenging because of the low signal-to-noise ratio (S/N) of the spectral lines and highly varying background due to naturally occurring radioactive material (NORM). In this work, we investigate the performance of the detection of orphan Cs-137, Am-241, and I-131 isotopes in a gamma ray data set obtained in a search survey. Isotopic detection is performed with a Hopfield Neural Network (HNN), which implements an auto-associative memory by matching incoming measurements to the closest one of its memory-stored signature patterns. HNN is trained on examples of spectra of calibrated isotopic sources with well-resolved spectral lines. During testing, HNN processes spectra with partially complete or distorted isotopic lines. The performance of the HNN detection algorithm is benchmarked with Precision, Recall, and F1 scores. Test results demonstrate the potential of HNN to detect the isotope of interest with high accuracy (F1 > 90%) for all isotopes in this study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Testing claims of the GW170817 binary neutron star inspiral affecting β-decay rates

On August 17, 2017, the first gravitational wave signal from a binary neutron star inspiral (GW170817) was detected by Advanced LIGO and Advanced VIRGO. Here we present radioactive β-decay rates of three independent sources 44 Ti, 60 Co and 137 Cs, monitored during the same period by a precision experiment designed to investigate the decay of long-lived radioactive sources. We do not find any significant correlations between decay rates in a 5 h time interval following the GW170817 observation. This contradicts a previous claim published in this journal of an observed 2.5σ Pearson Correlation between fluctuations in the number of observed decays from two β-decaying isotopes ( 32 Si and 36 Cl) in the same time interval. By correcting for the choice of an arbitrary time interval, we find no evidence of a correlation above 1.5σ confidence. In addition, we argue that such analyses on correlations in arbitrary time intervals should always correct for the so-called Look-Elsewhere effect by quoting the global significance.

79 ASTRONOMY AND ASTROPHYSICS↗

Single molecule insights into interfacial molecular recognition for model electrochemical DNA biosensors

Electrochemical sensors that use surface-immobilized DNA to bind analytes and transduce the binding into electrochemical signals, have the potential for rapid, specific, and sensitive detection of bioanalytes via a compact and portable platform. However, accessing the structure of these surfaces/interfaces at the relevant spatial scale (< 10 nm), which determines the interfacial interactions and ultimately sensing performance, remains an unsolved challenge. Here, we review studies that have used high resolution atomic force microscope imaging and spatial statistical analysis tools to understand crowding interactions between thiolated DNA probes immobilized on gold electrodes and how such interactions impact target binding. We also review related studies that attempt to control the nanoscale spatial arrangement of the immobilized recognition elements to optimize sensing performance. Furthermore, these efforts have led to new advances in understanding of the structure-function relationships of DNA-based electrochemical biosensors to move the field toward rational engineering of these biosensing interfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A general-purpose method for Pareto optimal placement of flow rate and concentration sensors in networked systems – With application to wastewater treatment plants

The advent of affordable computing, low-cost sensor hardware, and high-speed and reliable communications have spurred installation of ubiquitous sensors in complex engineered systems. However, ensuring reliable data quality remains a challenge. Exploitation of redundancy among sensor signals can help improving the precision of measured variables, detecting the presence of gross errors, and identifying faulty sensors. The cost of sensor ownership, maintenance efforts in particular, can still be cost-prohibitive however. Maximizing the ability to assess and control data quality while minimizing the cost of ownership thus requires a careful sensor placement. To solve this challenge, in this work we develop a generally applicable method to solve the multi-objective sensor placement problem in systems governed by linear and bilinear balance equations. Importantly, the method computes all Pareto-optimal sensor layouts with conventional computational resources and requires no information about the expected sensor quality.

42 ENGINEERING↗

Heat pulse testing at monitoring wells to estimate subsurface fluid velocities in geological CO 2 storage

Monitoring the injected CO 2 during geological CO 2 storage (GCS) is essential to assure containment and identify CO 2 leakage. Here in this work, a new approach is introduced to estimate the evolution of the downhole fluid velocity at a monitoring well and identify CO 2 arrival time using in-well heat pulse/tracer test. The proposed technique involves using a downhole heater to generate a series of heat pulses and measuring their corresponding temperature response. The surface temperature of the downhole heater is controlled by the supplied electrical power and the heat loss by convection to the surroundings. Convective heat transfer is well described using Newton's law of cooling in which the temperature difference between the heater and the surrounding fluids drives the heat transfer, for which the convection heat transfer coefficient (h) controls the magnitude of heat loss. Among various factors that control h, it depends on the type of the flowing fluid and its velocity. Through analyzing the measured temperature at different heat pulses, the changes in h - due to mobilization of the in-situ brine or CO 2 arrival - can be estimated. Consequently, the velocity of the flowing fluid across the heater can be obtained. Since heat transfer by convection is sensitive to the type of the surrounding fluid, intrusion of CO 2 can be detected from the relatively higher surface temperature obtained at CO 2 arrival. Churchill and Bernstein (1977)'s correlation is adopted to estimate the change of fluid velocity in terms of the change in h. To demonstrate the validity of the proposed technique, the results are applied and validated against those of COMSOL Multiphysics simulation tool for single-phase brine (before CO 2 arrival) and single-phase CO 2 (after CO 2 arrival). The observed temperature heating is sensitive to the flowing fluid velocity and fluid type. The temperature signal observed at CO 2 arrival is large and easily detectable using temperature monitoring tool which provides reliable indication for tracking CO 2 arrival at monitoring wells compared with passive temperature monitoring. The results obtained using the proposed technique agree very well with the numerical results obtained from the simulation tool with a maximum estimation error of 7 percent.

02 PETROLEUM↗

First-Principles insights into group-V impurities and their impact on germanium detector performance

The outstanding properties of high-purity germanium (HPGe) detectors, such as excellent energy resolution, high energy sensitivity, and a low background-to-signal ratio, make them essential and ideal candidates for detecting particle signatures in nuclear processes such as neutrino-less double beta decay (0νββ). However, the presence of defects and impurities in HPGe crystals can lead to charge trapping, which affects carrier mobility and results in significant energy resolution degradation. In this work, we employ density functional theory with a hybrid functional to study the energetics of possible point defects in Ge. Our findings indicate that group-V impurities form more readily in Ge compared to vacancy and interstitial of Ge. Unlike N dopants, which yield deep trap states, P, As, and Sb create shallow traps close to the conduction band edge of Ge. Furthermore, we predict that group-V defects can condense into defect complexes with Ge vacancies. These vacancy-impurity complexes form deep traps in Ge, similar to Ge vacancies, suggesting that both vacancies and vacancy-impurity complexes contribute to charge trapping in these detectors, thereby diminishing their performance.

36 MATERIALS SCIENCE↗

Transcriptomic and proteomic signatures of stemness and differentiation in the colon crypt

The intestinal epithelium is replaced weekly by non-quiescent stem cells with kinetics that rely on a rapid loss of stemness and choice for secretory or absorptive lineage differentiation. To determine how the cellular transcriptome and proteome changes during these transitions, we developed a new cell sorting method to purify stem cells, secretory and absorptive progenitor cells, and mature, differentiated cells. Transcriptome analyses revealed that as stem cells transition to the progenitor stage, alternative mRNA splicing and polyadenylation dominate changes in the transcriptome. In contrast, as progenitors differentiate into mature cell types, alterations in gene expression and mRNA levels drive the changes. RNA processing targets mRNAs encoding regulators of cell cycle, RNA regulators, cell adhesion, SUMOylation, and Wnt and Notch signaling. Additionally, global proteome profiling of sorted cell populations detected >2,800 proteins and revealed RNA:protein patterns of abundance and correlation. Paired together, these data highlight new potentials for autocrine and feedback regulation and provide new insights into cell state transitions in the crypt.

59 BASIC BIOLOGICAL SCIENCES↗

Dark matter density profiles in dwarf galaxies: linking Jeans modelling systematics and observation

ABSTRACT The distribution of dark matter in dwarf galaxies can have important implications on our understanding of galaxy formation as well as the particle physics properties of dark matter. However, accurately characterizing the dark matter content of dwarf galaxies is challenging due to limited data and complex dynamics that are difficult to accurately model. In this paper, we apply spherical Jeans modelling to simulated stellar kinematic data of spherical, isotropic dwarf galaxies with the goal of identifying the future observational directions that can improve the accuracy of the inferred dark matter distributions in the Milky Way dwarf galaxies. We explore how the dark matter inference is affected by the location and number of observed stars as well as the line-of-sight velocity measurement errors. We use mock observation to demonstrate the difficulty in constraining the inner core/cusp of the dark matter distribution with data sets of fewer than 10 000 stars. We also demonstrate the need for additional measurements to make robust estimates of the expected dark matter annihilation signal strength. For the purpose of deriving robust indirect detection constraints, we identify Ursa Major II, Ursa Minor, and Draco as the systems that would most benefit from additional stars being observed.

79 ASTRONOMY AND ASTROPHYSICS↗

Numerical relativity simulations of the neutron star merger GW190425: microphysics and mass ratio effects

ABSTRACT GW190425 was the second gravitational wave (GW) signal compatible with a binary neutron star (BNS) merger detected by the Advanced LIGO and Advanced Virgo detectors. Since no electromagnetic counterpart was identified, whether the associated kilonova was too dim or the localization area too broad is still an open question. We simulate 28 BNS mergers with the chirp mass of GW190425 and mass ratio 1 ≤ q ≤ 1.67, using numerical-relativity simulations with finite-temperature, composition dependent equations of state (EOS) and neutrino radiation. The energy emitted in GWs is $\lesssim 0.083\mathrm{\, M_\odot }c^2$ with peak luminosity of 1.1–$2.4\times ~10^{58}/(1+q)^2\, {\rm {erg \, s^{-1}}}$. Dynamical ejecta and disc mass range between 5 × 10−6–10−3 and 10−5–$0.1 \mathrm{\, M_\odot }$, respectively. Asymmetric mergers, especially with stiff EOSs, unbind more matter and form heavier discs compared to equal mass binaries. The angular momentum of the disc is 8–$10\mathrm{\, M_\odot }~GM_{\rm {disc}}/c$ over three orders of magnitude in Mdisc. While the nucleosynthesis shows no peculiarity, the simulated kilonovae are relatively dim compared with GW170817. For distances compatible with GW190425, AB magnitudes are always dimmer than ∼20 mag for the B, r, and K bands, with brighter kilonovae associated to more asymmetric binaries and stiffer EOSs. We suggest that, even assuming a good coverage of GW190425’s sky location, the kilonova could hardly have been detected by present wide-field surveys and no firm constraints on the binary parameters or EOS can be argued from the lack of the detection.

79 ASTRONOMY AND ASTROPHYSICS↗